Roof Fans. web-version

Similar documents
The IRE 125 insulated duct fan is fitted

TKC, TKS, TKV/TKH Roof fans

Directions for use CK 125 C EC, CK 150 B EC, CK 160 B EC, CK 160 C EC CK 200 B EC, CK 250 B EC, CK 315 B EC, CK 315 C EC ENGLISH VERSION

Wall mounted fan

CK, LPK, LPKB. Duct fans with circular connection.

GV In Line Circular Duct Fan Circular Ducting High/Low Speed Performance

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

IN-LINE CENTRIFUGAL DUCT FANS VT Series

IN-LINE RECTANGULAR FANS IRB / IRBS IRB

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Single-inlet centrifugal fans

NEW Slimpak EC Box Fan (SLPT EC)

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

ROOF FAN ROOFMASTER STEC

In-line rectangular fans. Technical Catalogue

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

VORTICENT C E RANGE Centrifugal fans

Device can be connected to pull air directly from ventilated room or air duct system. Not suitable for polluted air or volatile and explosive gases.

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Device can only be used indoors. Not suitable for polluted air or volatile and explosive gases. Single phase speed controller.

KV sileo 100 M. Circular duct fans. Circular duct fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Sabre Plate Mounted Sickle Fans (VSP)

Performance. Sound Levels. Impellers. Motors. Accessories

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

CRH RANGE - TECHNICAL DATA CENTRIFUGAL ROOF FANS

IN-LINE MIXED FLOW DUCT FANS MIXVENT-TD Fan Systems

Sentinel D-Box Twin Fan

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

SILENT MV Ultra Quiet In-line Fans

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

GigaBox centrifugal fans Product specific information

supplied in Form (B) configuration. Airflow over Impeller- Motor.

NEW Acoustic In-Line Fans (ACQ)

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

Vent-Axia Sabre Sickle Roof Fans (VSR)

valymui. - - Rectangular Flexible connection duct silencer Filter cassette Electrical duct heater LJ/E

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

Square Mixed Flow Fans (MFQ)

AC Commercial Fans Edition. ErP ready

Sentinel D-Box Single Fan

ROOFMASTER STEF-HT ROOF FAN

Terminal Box Are to IP54, as standard, protected against dust and water from any angle allowing outside applications.

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

Grey Water and Condensate Pump. Rotex. Type Series Booklet

CENTRIFUGAL IN-LINE FANS VENT Series

ACOUSTIC CABINET FANS CVB / CVT Series

MegaBox Product-specific information

BESB and BESF Box fans for extraction and air supply jobs BESB - backward curved vanes BESF - forward curved vanes

Centrifugal fan with highly efficient EC drive motor

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Axial fans. What s more, non-stock models are normally available within two weeks.

CYCLONE F 400 smoke extraction casing

series RVV Variable flow rate controllers

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

TWINFLOW STDR Product Brochure

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

SV-UNOBOX FAN. Mutassim Al-Daour factory for Metal Industries SV-7

Sabre Sickle Fan Assisted Roof Cowls (VSR)

BOX BLB Centrifugal Box Fan

High efficiency low noise Speed-controllable Integral thermal contacts Can be installed in any position Maintenance-free and reliable

BACKWARD CURVE CENTRIFUGAL FANS KABB / KABT Series

GmbH Lufttechnik Dresden USER INFORMATION ROOF FANS SERIES VRV. vertical outlet. Issue 07/02

Acoustic Twin Fans (ATQ)

TCDH F400-TCDV F400. Smoke extract - Fire protection SMOKE EXTRACT FANS CENTRIFUGAL BACKWARD ROOF FANS F Application. Range.

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence

Powerful centrifugal fans for universal use: The product ranges TEM and REM

QUBE SQU-HT(S) Product Brochure

Rectangular inlet air diffuser

ROOF MOUNTED FANS MIXVENT-TH Series Mixed Flow Fans MIXVENT-TH. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

Thermo fans. Systemair range Systemair thermo fans are available in three different executions. The Multibox MUB-K ASF/KB. Flexible connection

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

MIXVENT-TH Series Mixed Flow Fans

VKA/VKAS. Circular duct fans CIRCULAR DUCT FANS

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

ROOFMASTER STEF-HT ROOF FAN

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

Fan - Powered Terminal Unit Series Flow

VENTS KSB K2. Series. Inline centrifugal fans in heat- and sound-insulated casing with air flow up to 7000 m 3 /h SOUND-INSULATED FANS

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Exhaust Fans CATALOGUE 2013 / 14

Plate mounted axial flow fans HXBR / HXTR Series

ROOF MOUNTED FANS TH-MIXVENT Series Mixed Flow Fans TH-MIXVENT. Roof mounted fans. Flame retardant terminal box. Circular spigot coupling

FANS WITH ENERGY EFFICIENT EC TECHNOLOGY

ACOUSTIC CABINET FANS Centribox CVB-CVT Series, Forward Curved Centrifugal Fans

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

ACOUSTIC CABINET FANS CVAB / CVAT Series

Mixed Flow Roof Fans (RMH)

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

Mixed Flow Roof Fans (RMH)

Transcription:

Roof Fans web-version

Contents TKS and TKC 4 TKS 300 5 TKC 300 6 TKS 400 7 TKC 400 8 TKK 9 TKK 300 9 TKK 400 10 page TKK 560 A1 12-13 TKK 560 B1 12-13 TKK 560 B3 12-13 TKK 660 B1 14-15 TKK 660 B3 14-15 TKK 760 A1 16-17 TKK 760 A3 16-17 TKK 760 B1 16-17 TKK 760 B3 16-17 3 TKK 960 A1 18-20 TKK 960 A3 18-20 TKK 960 B1 18-20 TKK 960 B3 18-20 TKK 960 C1 18-20 TKK 960 C3 18-20 TKK 960 D3 18-20 TKK 1060 A3 21-22 TKK 1060 B3 21-22 Accessories TF, roof curbs and silencers, TKLD 23 TG, pre-wired roof plates for TKC fans 24 Installation, operation and maintenance instructions 25 Sound data explanations and wiring-diagrams 26

TKS and TKC TKS and TKC are similar, except for their installation connections, the TKS is curb mounting, the TKC has a circular connenction and a flat weathering skirt. 4 The Östberg company was founded in 1981 and has now 160 employees. Reliability All TKS- and TKC-fans are easy to install. They are constructed in galvanised sheet metal, polyester coated for corrosion resistance. An european external rotormotor (speed controllable) of high quality, with backward curved impeller ensures high performance and safe operation. The motors have sealed for lifetime ball bearings. Service TKS and TKC have all swing-out design, for ease of cleaning and maintenance. 2 1 The sketch shows how the ballbearing external rotor induction motor(1) is mounted inside the casing. (2) Electrical connections in an IP 44 terminal box. Östberg is one of the worlds leading fan manufacturers, with distribution in more than 60 countries. Thousands of fans are manufactured every week, and are despatched only once they have been passed by Östberg s rigorous inspection system. Östberg is an ISO 9001 and ISO 14001 accredited company.

TKS 300 TKS 300 is a side discharge roof extract unit, with swing-out motor and impeller for ease of installation and maintenance. It is suitable for curb mounting and can be supplied with a square roof curb (TF) and silencer. TKS 300 5 Inlet ø: D1= 168 mm, D2= 124 mm. See page 26. Ideas grow in the design office. Auto-CAD is used to transmit ideas into drawings. Advanced computer programs do, already at this stage, calculate the fan-datas. swing More than 80% of all the fans we produce are exported. Östberg is qualified according to ISO 9001 and ISO 14001. out Swing-out is standard on all TK-fans. A simple hand grip and they are ready for inspection and cleaning.

TKC 300 TKC 300 is a side discharge roof extract unit, with swing-out motor and impeller for ease of installation and maintenance. It is suitable for curb mounting and can be supplied with a circular roof curb (TG) and silencer. In the Emirates it is hot. There they since many years use efficient fans from CA Östberg. TKC 300 TKC 300 A/B/C, TKS 300 A/B/C 6 Inlet ø: D1= 168 mm, D2= 124 mm. See page 26. Technical data Roof extract unit TKC, TKS 300 A 300 B 300 C Voltage V 230 230 230 Current A 0.19 0.20 0.31 Input watts W 44 45 71 Speed Rpm 1700 2250 2460 Weight kg 4.1 4.1 4.1 Wiring, page 26 No. 4040002 4040002 4040001 Sound data Flow/ Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 48 55 37 47 50 49 47 44 34 19 32 l/s Inlet with TFU 39 46 34 41 42 38 37 30 16 9 TKS/TKC 300 A 155 Pa To environment 49 56 48 33 44 48 52 48 39 33 Inlet 54 61 42 50 57 55 54 52 44 31 53 l/s Inlet with TFU 45 52 40 43 49 44 43 37 25 12 TKS/TKC 300 B 150 Pa To environment 55 62 48 38 50 54 59 56 48 39 Inlet 58 65 46 53 60 59 58 57 49 38 70 l/s Inlet with TFU 49 56 43 47 52 49 47 42 31 20 TKS/TKC 300 C 217 Pa To environment 60 67 48 40 54 58 64 62 54 45 Explanations to Sound data, see page 26. L pa L WA

TKS 400 TKS 400 is a side discharge roof extract unit, with swing-out motor and impeller for ease of installation and maintenance. It is suitable for curb mounting and can be supplied with a square roof curb (TF) and silencer. TKS 400 You find our fans in all EUcountries. 7 Inlet ø: D1=206 mm, D2=160 mm. See page 26. In a special plant prototypes are built and tested, all to make sure we can supply our customers with high quality products. Some of them will not fulfill our demands, while others will be standard products. A good example of this is our CK-fan, of which we now have supplied more than one million to customers all over the world.

TKC 400 TKC 400 is a side discharge roof extract unit, with swingout motor and impeller for ease of installation and maintenance. It is suitable for curb mounting and can be supplied with a circular roof curb (TG) and silencer. You find fans from CA Östberg in almost every country in Asia. TKC 400 TKC 400 A/B/C, TKS 400 A/B/C, 8 Inlet ø: D1=206 mm, D2=160 mm. See page 26. Technical data Roof extract unit TKC, TKS 400 A 400 B 400 C Voltage V 230 230 230 Current A 0.42 0.50 0.76 Input watts W 91 113 172 Speed Rpm 1850 2580 2420 Weight kg 5.5 5.5 5.5 Wiring, page 26 No. 4040002 4040001 4040001 Sound data Flow/ L pa L WA Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 58 65 46 58 60 59 57 52 44 30 110 l/s Inlet with TFU 48 55 41 52 50 48 42 31 25 17 TKS/TKC 400 A 135 Pa To environment 58 65 42 44 56 60 60 57 51 38 Inlet 65 72 50 61 68 67 64 59 53 40 150 l/s Inlet with TFU 54 61 44 54 57 55 48 38 35 27 TKS/TKC 400 B 230 Pa To environment 65 72 44 47 63 66 67 65 60 48 Inlet 64 71 54 62 64 67 63 58 57 48 180 l/s Inlet with TFU 54 61 49 55 53 58 49 42 40 35 TKS/TKC 400 C 300 Pa To environment 69 76 48 48 61 69 72 70 63 57 Explanations to Sound data, see page 26.

TKK TKK is a roof extract unit with vertical discharge and swingout of motor and impellar for ease of installation and maintenance. It is suitable for curb mounting and can be supplied with a roof curb (TF) and a silencer. Reliability All TKK 300- and 400-fans are easy to install. They are constructed in galvanised sheet metal, polyester plastic coated for corrosion resistance. A european external rotor-motor (speed controllable) of high quality, with backward curved impellar, ensures high performance and safe operation. The motor has sealed for lifetime bearings. 2 1 The sketch shows how the ballbearing external rotor induction motor(1) is mounted inside the casing. (2) Electrical connections in an IP 44 terminal box. An exciting example of where you can find Östberg fans is Chek Lap Kok, the new international airport in Hong Kong. TKK 300 TKK 300 can be supplied in two versions. TKK 300 A with a max. flow of 320 m 3 /h and TKK 300 C with max. 520 m 3 /h. 9 Sound data Flow/ L pa L WA Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 50 57 44 50 53 50 46 42 34 19 Inlet with TFU 42 49 40 45 45 41 38 32 18 3 TKK 300 A 30 l/s, 120 Pa To environment 50 57 43 38 47 52 51 49 41 35 Inlet 59 66 51 57 61 61 59 57 50 38 Inlet with TFU 51 58 47 51 53 52 49 45 34 22 TKK 300 C 100 l/s, 190 Pa To environment 62 69 42 45 57 63 64 65 59 47 Inlet 55 62 44 54 57 57 55 49 41 26 Inlet with TFU 44 51 39 46 47 44 37 29 23 13 TKK 400 A 110 l/s, 108 Pa To environment 58 65 41 41 57 59 58 60 52 37 Inlet 65 72 51 60 66 68 64 58 54 42 Inlet with TFU 53 60 47 53 55 56 47 39 36 27 TKK 400 B 148 l/s, 232 Pa To environment 68 75 43 48 64 69 68 71 65 52 Inlet 64 71 52 59 62 68 63 59 56 49 Inlet with TFU 54 61 49 54 53 58 50 42 39 35 TKK 400 C 167 l/s, 338 Pa To environment 69 76 49 50 63 71 71 70 66 59 Inlet 65 72 54 61 64 68 64 60 59 50 Inlet with TFU 56 63 50 55 54 61 52 44 40 34 TKK 400 D 250 l/s, 280 Pa To environment 72 79 44 49 63 74 73 73 68 61 Explanations to Sound data, see page 26.

TKK 400 TKK 400 is one of our best selling roof extract units, with a maximum flow of 1240 m 3 /h. Roof curb with silencer are accessories. 10 TKK 300 TKK 400 Technical data Roof extract unit TKK 300 A 300 C 400 A 400 B 400 C 400 D Voltage V 230 230 230 230 230 230 Current A 0.20 0.32 0.27 0.45 0.67 0.82 Input watts W 46 73 62 102 153 186 Speed Rpm 1715 2410 1705 2480 2490 2460 Weight kg 5.5 5.5 8.2 8.2 8.2 8.3 Wiring, page 26 No. 4040010 4040011 4040010 4040011 4040011 4040011 TKK 300 A/C Inlet ø: D1=168 mm, D2=124 mm. See page 26. TKK 400 A/B/C/D Inlet ø: D1=206 mm, D2=160 mm. See page 26. Explanations to Sound data, see page 26.

TKK TKK 560-1060 are our new bigger sizes of roof extract units with vertical discharge and swing-out design. 1 Reliability They are all constructed in galvanised sheet metal and equipped with a european external rotormotor, with backward curved impellers of highest quality. All can be speed controlled. 11 2 A silencer can easily be fitted (or retrofitted) on the top of all sizes from TKK 560 B1 and upwards. Like with all previous types, they are easy to clean, due to the swing-out design.

TKK 560 A1 Max. 1580 m 3 /h. TKK 560 A1 TKK 560 B1 Max. 2450 m 3 /h. Inlet ø: D1= 260 mm, D2=202 mm. TKK 560 B3 Max. 2340 m 3 /h. Accessories Roof curb TFU and silencer TKLD. TKK 560 12 Technical data Roof extract unit TKK 560 560 A1 560 B1 560 B3 Voltage V 230 230 400 Current A 0.56 1.19 0.50 Input watts W 125 265 258 Speed Rpm 1300 1300 1400 Weight kg 16 27 27 Wiring, page 26 No. 4040001 4040005 / 4040030 4040006 Sound data Flow/ L pa L WA Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 57 64 53 61 58 57 50 48 48 34 Inlet with TFU 55 62 47 59 56 55 45 37 43 30 560 A1 264 l/s, 166 Pa To environment 61 68 44 52 62 64 61 58 57 45 Inlet 63 70 57 65 63 64 56 54 47 38 Inlet with TFU 60 67 56 63 61 62 51 55 46 34 To environment 66 73 50 59 68 67 67 66 58 52 560 B1 389 l/s, 253 Pa To env. with TKLD 62 69 49 59 66 63 60 59 53 45 Inlet 65 72 58 67 66 66 58 59 53 45 Inlet with TFU 63 70 57 65 65 65 53 50 45 38 To environment 68 75 51 59 70 68 68 68 61 53 560 B3 430 l/s, 245 Pa To env. with TKLD 64 71 51 59 68 64 60 62 56 49 Explanations to Sound data, see page 26. Inlet ø: D1= 294 mm, D2=228 mm. See page 26.

TKK 560 A1 TKK 560 B1 TKK 560 B3 Pos. on transformer/curve 5 4 3 2 1 1-phase V 230 165 135 110 80 3-phase V 400 240 185 145 95 13 www.ostberg.com

TKK 660 B1 TKK 660 is delivered in single phase (B1) and 3-phase (B3) version. Max. 3000 m 3 /h. 14 TKK 660 B3 Max. 3000 m 3 /h. Accessories Roof curb TFU and silencer TKLD. Sound data Flow/ L pa L WA Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 67 74 63 69 68 69 61 61 55 43 Inlet with TFU 64 71 60 66 66 67 56 51 47 33 To environment 70 77 55 63 72 71 72 70 62 53 660 B1 640 l/s, 296 Pa To env. with TKLD 65 72 53 62 69 66 62 62 57 48 Inlet 67 74 63 70 68 68 61 60 53 44 Inlet with TFU 64 71 60 66 66 67 67 53 47 37 To environment 69 76 52 62 71 70 71 67 60 53 660 B3 653 l/s, 298 Pa To env. with TKLD 66 73 52 62 69 67 64 64 59 50 Explanations to Sound data, see page 26.

TKK 660 B1 TKK 660 B3 Pos. on transformer/curve 5 4 3 2 1 1-phase V 230 165 135 110 80 3-phase V 400 240 185 145 95 15 Technical data TKK 660 serien 660 B1 660 B3 Voltage V 230 400 Current A 2.41 0.90 Input watts W 490 450 Speed Rpm 1250 1400 Weight kg 34 34 Wiring, page 26 No. 4040005 / 4040030 4040006 TKK 660 Swing-out =easy service! Inlet ø: D1=341 mm, D2=257 mm. See page 26.

TKK 760 Is delivered in four versions. TKK 760 A1 Max. 3000m 3 /h. TKK 760 A3 Max. 3400m 3 /h. TKK 760 B1 Max. 4450m 3 /h. TKK 760 B3 Max. 4750m 3 /h. Accessories Roof curb TFU and silencer TKLD. TKK 760 16 Technical data Roof extract unit TKK 760 760 A1 760 A3 760 B1 760 B3 Voltage V 230 400 230 400 Current A 1.10 0.58 3.50 1.45 Input watts W 240 258 725 700 Speed Rpm 890 904 1370 1240 Weight kg 39 39 43 40 Wiring, page 26 No. 4040005 / 4040030 4040005 / 4040030 4040006 4040006 Sound data Flow/ L pa L WA Inlet ø: D1=373 mm, D2=289 mm. See page 26. Type of fan Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 55 62 54 58 55 56 49 46 44 27 Inlet with TFU 50 57 52 52 50 48 38 38 30 16 To environment 57 64 50 50 57 60 60 53 47 38 TKK 760 A1 612 l/s, 134 Pa To env. with TKLD 53 60 50 50 55 55 51 47 43 36 Inlet 57 64 56 60 57 58 50 47 43 30 Inlet with TFU 52 59 53 54 53 51 40 40 32 20 To environment 57 64 48 50 58 58 59 55 50 41 TKK 760 A3 576 l/s, 163 Pa To env. with TKLD 54 61 47 50 57 55 51 49 46 38 Inlet 68 75 64 69 70 70 63 60 55 46 Inlet with TFU 63 70 60 65 65 65 50 52 44 34 To environment 73 80 58 67 74 75 74 68 61 54 TKK 760 B1 920 l/s, 360 Pa To env. with TKLD 68 75 58 68 70 70 66 61 57 49 Inlet 68 75 65 69 70 71 65 61 55 45 Inlet with TFU 63 70 61 64 65 65 50 52 43 33 To environment 72 79 57 65 73 75 75 69 62 54 TKK 760 B3 967 l/s, 300 Pa To env. with TKLD 67 74 57 65 70 70 66 61 57 49 Explanations to Sound data, see page 26.

TKK 760 A1 TKK 760 A3 Pos. on transformer/curve 5 4 3 2 1 1-phase V 230 165 135 110 80 3-phase V 400 240 185 145 95 17 TKK 760 B1 TKK 760 B3

TKK 960 TKK 960 is delivered in seven versions, with a flow from 4425m 3 /h to 9400 m 3 /h. Accessories Silencer TKLD. TKK 960 A1 Max. 4900 m 3 /h. TKK 960 A3 Max. 4425 m 3 /h. TKK 960 B1 Max. 5760 m 3 /h. TKK 960 B3 Max. 5940 m 3 /h. TKK 960 C1 Max. 7200 m 3 /h. TKK 960 C3 Max. 8250 m 3 /h. TKK 960 D3 Max. 9400 m 3 /h. 18 TKK 960 A1 TKK 960 A3

TKK 960 B1 TKK 960 B3 Pos. on transformer/curve 5 4 3 2 1 1-phase V 230 165 135 110 80 3-phase V 400 240 185 145 95 19 TKK 960 C1 TKK 960 C3

TKK 960 TKK 960 TKK 960 D3 20 Inlet ø: TKK 960 A/C: D1=420 mm, D2=325 mm. TKK 960 B/D: D1=472 mm, D2=365 mm. See page 26. Pos. on transformer/curve 5 4 3 2 1 1-phase V 230 165 135 110 80 3-phase V 400 240 185 145 95

TKK 1060 TKK 1060 is our most powerful roof extract unit. You can choose between TKK 1060 A3 and TKK 1060 B3. Accessories Silencer TKLD. TKK 1060 TKK 1060 A3 TKK 1060 A3 Max. 5700m 3 /h. TKK 1060 B3 Max. 9150m 3 /h. TKK 1060 B3 Inlet ø: D1=511 mm, D2=410 mm. See page 26. 21

TKK 960 & TKK 1060 Technical data TKK 960 and 1060 960 A1 960 A3 960 B1 960 B3 960 CI 960 C3 960 D3 1060 A3 1060 B3 Voltage V 230 400 230 400 230 400 400 400 400 Current A 2.05 1.44 3.15 1.27 6.85 2.80 4.40 1.41 2.10 Input watts W 435 373 670 616 1300 1300 2000 410 980 Speed Rpm 900 910 890 870 1380 1360 1370 670 880 Weight kg 61 60 62 65 71 67 75 90 95 Wiring, page 26 No. 4040005 / 4040030 4040005 / 4040030 4040005 / 4040030 4040030 4040030 4040030 4040006 4040006 4040006 22 Sound data L pa L WA Type of fan Flow/Total pressure db(a) tot 63 125 250 500 1k 2k 4k 8k Inlet 61 68 59 63 60 59 58 58 50 36 To environment 65 72 52 57 64 67 66 64 57 47 TKK 960 A1 820 l/s, 179 P, To env. with TKLD 60 67 52 57 60 60 57 57 52 42 Inlet 61 68 60 61 62 61 60 59 52 39 To environment 66 73 53 56 64 69 68 65 58 48 TKK 960 A3 740 l/s, 200 Pa To env. with TKLD 60 67 53 56 61 62 58 58 53 44 Inlet 63 70 62 63 64 62 61 61 54 41 To environment 67 74 54 59 67 68 68 66 60 50 TKK 960 B1 1026 l/s, 213 Pa To env. with TKLD 61 68 54 59 63 61 59 59 54 45 Inlet 64 71 62 64 65 63 62 63 56 43 To environment 68 75 55 59 68 70 70 67 61 52 TKK 960 B3 1000 l/s, 235 Pa To env. with TKLD 62 69 55 59 64 64 61 61 56 47 Inlet 72 79 68 74 74 73 71 67 59 48 To environment 76 83 61 69 75 78 79 73 65 59 TKK 960 C1 1174 l/s, 465 Pa To env. with TKLD 70 77 61 69 72 71 70 66 60 54 Inlet 72 79 68 72 74 71 71 70 64 52 To environment 75 82 61 68 75 76 77 74 70 62 TKK 960 C3 1195 l/s, 472 Pa To env. with TKLD 69 76 61 68 72 69 68 68 65 57 Inlet 75 82 71 75 77 75 72 72 67 56 To environment 78 85 63 72 79 79 80 76 73 66 TKK 960 D3 1600 l/s, 590 Pa To env. with TKLD 73 80 63 71 76 73 71 70 68 61 Inlet 58 65 57 56 61 61 52 50 39 26 To environment 60 67 50 54 61 62 61 56 48 40 TKK 1060 A3 1046 l/s, 118 Pa To env. with TKLD 55 62 50 53 58 56 52 49 43 36 Inlet 68 75 65 68 71 69 63 62 53 41 To environment 71 78 59 66 71 74 72 67 60 53 TKK 1060 B3 1455 l/s, 310 Pa To env. with TKLD 65 72 59 65 68 66 63 60 55 49 Explanations to Sound data, see page 26.

Roof curb TF Silencer TFU is produced in two different lengths, see measurements. It is constructed in galvanised sheet metal and includes a 50 mm pad of rockwool, with a glassfibre coated surface. Plastic conduit for electrical wiring is provided as standard. TFU Measurements for TFU Type A B C TFU 300/600 600 190 295 TFU 300/900 900 190 295 TFU 400/600 600 290 395 TFU 400/900 900 290 395 TFU 560/900 900 402 506 TFU 660/900 900 502 606 TFU 760/900 900 602 706 TFU 960/900 900 805 910 23 Silencer TKLD Silencer TKLD is constructed in galvanised sheet metal and includes a 50 mm pad of rockwool, with a glassfibre coated surface.

Roof curb and silencer TG TGÖ is constructed in galvanised sheet metal, polyester plastic coated for corrosion resistance. Can be supplied plane or profiled. Two meters of el. cable is provided as standard as well as 30 mm of rockwool insulation. 24 TGÖ plain TGÖ profile TGU

Instructions for maintenance Roof extract units TKC, TKS and TKK from C.A. Östberg are all equipped with an asynchronus motor of external rotor type with sealed for lifetime ball bearings. Single phase motors are equipped with an approved thermo-contact protector with automatic reset. 3-phase motors are ready wired with thermo-contact leads. These must be connected over a motorprotector, or if speed control is used, over a thermo-contact relay, fitted as standard in our 3-phase transformers.the thermo-contact breaks the current if the temperature in the motor windings becomes excessive. In single-phase motors the thermo-contact is reset as follows: Turn off the mains power. Wait until the motor has cooled. Reconnect the mains power. The fans are intended for continuous operation and can be speed-controlled by voltage variation using external regulators. They are NOT designed for transporting explosive gases, grinding dust, soot or similar. Electrical installation The fan may only be installed by a qualified electrician. All fans are supplied fully-wired and ready to fit in a sealed installation unit. 1. Check that the voltage, frequency, cycles etc of the mains correspond with the specifications on the fan s ID plate. 2. All electrical wiring and connections must be carried out in compliance with your national safety regulations. 3. The fan must be earthed! Installation and fitting Maximum temperature of transported air, see diagrams. 25 Care and maintenance The only maintenance required is cleaning. We recommend inspection of the impeller every six months if the fan is operated continuously. Before cleaning: Disconnect the mains and block the mains switch. Wait until the motor and impeller has stopped rotating. Care must be taken during dismantling and cleaning so as not to disturb the fan s balance. Strong detergents or cleaning agents must not be used for cleaning the fan. Internal insulation may be wiped clean with a damp cloth. Sharp or rotating tools must not be used as these may damage outer surfaces. In case of breakdown 1. Check that mains power is reaching the fan. 2. Disconnect from the mains and make sure the impeller is not blocked. 3. Check the thermo-contact according to the description above. If the thermo-contact has activated, the cause of overheating should be determined to prevent the same fault recurring. 4. If the fault persists, change the capacitor. 5. If these steps do not help, contact your supplier.

Explanations to sound data The sound data have been compiled by means of sound measurement methods as follows: Pressure and flow: ISO 5801 Determination of acoustic sound level in duct: ISO 5136 Determination of acoustic sound level in reverberation room: ISO 3741 Designations L W A tot: Total A-weighted sound power level db(a) (ref 10-12 W)=the sum of the sound power level in the octave ranges. L W A : A-weighted sound power level in octave range db(a) (ref 10-12 W). L pa : A-weighted sound pressure level in db(a) according to normed A-weightening correction and relating to an effective absorption area of 20 m 2 with half spherical translation at a distance of 3 meters. Inlet Measurements according to sketch. 26 SFP Lately there has been an increased demand for good SFP (Specific Fan Power) on fans. SFP is a measurement for the size of the total power at a specific flow / pressure and is calculated in kw/m 3 /second. Wiring diagrams WIRING DIAGRAM 4040001 Single phase FAN Yellow-Green Black Blue Brown Single phase WIRING DIAGRAM 4040003 3-phase 230V FAN Yellow-Green 3-phase Y 400V WIRING DIAGRAM 4040005 Single phase with outdrawn thermo-contact lead Yellow-Green Black WIRING DIAGRAM 4040006 Single phase for external thermo-contact relay Yellow-Green Black FAN White (TW) Brown Blue FAN Blue Brown White (TW) White (TW) White (TW) WIRING DIAGRAM 4040010 Wiring diagram with switch FAN Yellow-Green Brown Black Blue Switch WIRING DIAGRAM 4040011 Wiring diagram with switch FAN Yellow-Green Brown Black Blue Switch 3-phase 400V

Other products: Insulated kitchen fan, IFK Circular duct fan, CK Square wall fan, KV Insulated duct fan, IRE Rectangular duct fan, RK www.ostberg.com Exhaust fan, RS Filterbox, FLK, FLF Heat-exchanger, HERU

AB C.A. ÖSTBERG INDUSTRIGATAN 2 S-774 35 AVESTA SWEDEN TEL +46 226-86 000 FAX +46 226-86 005 e-mail: info@ca-ostberg.se www.ostberg.com OLA HÖGLUND GRAFISK FORM. PHOTOGRAPHY: PATRIK LINDSTRÖM. COPY: ORDFÖRRÅDET. PRINTED BY DALA PRINT MEDIA. 0312

Roof fans