IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

Similar documents
W-VACi MV circuit breakers

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

Powering business worldwide

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

XIRIA Green, Smart, Compact solution

the safe, reliable, and efficient choice for MV switchgear

E-VAC Series Medium Voltage Vacuum Circuit Breaker

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

E-VAC EP Series Medium Voltage Vacuum Circuit Breaker

Unitole UP kv Primary substations Motor control centres

12kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

SL Series IEC Vacuum Contactors. Medium Voltage Contactors Technical Focus

40.5kV W-VACi Series Medium Voltage Vacuum Circuit Breaker

Unitole UP kv Primary substations Motor control centres

Eaton Safe, Reliable, Efficient IEC MV Switchgear. xgear Safe, Reliable, Efficient IEC MV Switchgear

Xiria the smart solution

Innovac SVS/08 - SVS/ kv modular switchgear

24kV ET1 Removable AC Metal-enclosed Switchgear With VE24 Encapsulated Pole Vacuum Circuit Breaker

Vacuum Circuit Breaker VS1

40.5kV ET2 Removable AC Metal-enclosed Switchgear

Safe, reliable MV switchgear

Xiria the smart solution

Magnefix kv Insulation enclosed switchgear. Magnefix. Compact switchgear for medium voltage distribution

Xiria 24 kv Ring Main Unit

Medium voltage vacuum circuit breaker. E-VAC series

Eaton vacuum interruption (EVI) technology. Proven vacuum interruption technology Environmentally focused circuit protection for global innovation

Safe, reliable MV switchgear

12kV xdl Removable AC Metal-enclosed Switchgear

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Xiria 12 kv Ring Main Unit in IEC and ENATS design

Unitole UX. Safe, reliable MV switchgear. Unitole UX IEC Medium Voltage switchgear

Metal Clad Air Insulated Switchgear

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

HVX Series. 36 kv Medium Voltage Vacuum circuit breaker. Make the most of your energy SM. Medium Voltage Distribution Catalogue 2015

Removable AC Metal-enclosed Switchgear

VCP-T/T-VAC medium voltage vacuum circuit breakers. Control and protect with Eaton s compact medium voltage circuit breakers

E6X MCB series. More complete More value

This small footprint makes a BIG impact

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

NXPLUS C Single busbar. Maintenance-free for lifetime

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

PIX-H Metal-clad switchgear up to 17.5kV

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

MEDIUM VOLTAGE SWITCHGEAR

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Gas-insulated medium-voltage switchgear. For the mining industry. Answers for energy.

CPG.0 Single busbar gas-insulated cubicles

3TM Vacuum Contactors

Gas Insulated Ring Main Unit RVAC. Professional solutions, Reliable power

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Power Xpert TM UX. Safe, reliable MV switchgear. Medium Voltage switchgear. Power XpertTM. Tested to GB kv up to 50 ka - 4 s

Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

THP145 HYBRID GAS INSULATED SWITCHGEAR (HGIS) Energy, Fast! tgood.com

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

MP-4000 Motor Protection

B kv T&D GAS INSULATED SWITCHGEAR

Air-insulated switchgear UniGear type ZS1

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Gas Insulated Ring Main Unit RVAC. Professional solutions, Reliable power

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

Medium Voltage Products Table Of Contents

Medium Voltage Products Table Of Contents

Circuit Breakers BZM. Product Information. Circuit Breaker BZM1 16 to 125 A. Circuit Breaker BZM2 125 to 250A. BZM1 & BZM2 Accessories

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Selection Guide Motor Control Device Solutions

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Independent Testing Laboratory for High Voltage Equipment

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Flexible. Intelligent. Trendsetting.

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Medium and low voltage systems for panel builders. Expertise. to solve your every application

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ASN3-12. Safe, reliable MV switchgear. ASN3-12 Metal enclosed medium voltage switchgear. Tested to GB kV 50kA-4s

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

8DJ. Maintenance-free for lifetime

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

Gas Insulated Metal-clad Switchgear, HMGS!

EMPAC Metal enclosed capacitor bank for wind applications

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Solid Dielectric, Three Phase Reclosers CATALOG VS11

3AH37 and 3AH38 vacuum generator circuit-breakers for power stations and industry

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage Metal-Enclosed Switches

Power Systems PU. HYOSUNG MV Gas Insulated Switchgear. ProGIS[MV GIS]

Transcription:

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide W-VACi for safety, reliability and performance

Automotive Powering business worldwide Aerospace Eaton delivers the power inside hundreds of products that are answering the demands of today s fast changing world. We help our customers worldwide manage the power they need for buildings, aircraft, trucks, cars, machinery and entire businesses. And we do it in a way that consumes fewer resources. Truck Hydraulics Next generation transportation Eaton is driving the development of new technologies from hybrid drivetrains and emission control systems to advanced engine components that reduce fuel consumption and emissions in trucks and cars. Higher expectations We continue to expand our aerospace solutions and services to meet the needs of new aviation platforms, including the high-flying light jet and very light jet markets. Building on our strengths Our hydraulics business combines localized service and support with an innovative portfolio of fluid power solutions to answer the needs of global infrastructure projects, including locks, canals and dams. Powering Greener Buildings and Businesses Eaton s Electrical Group is a leading provider of power quality, distribution and control solutions that increase energy efficiency and improve power quality, safety and reliability. Our solutions offer a growing portfolio of green products and services, such as energy audits and real-time energy consumption monitoring. Eaton s Uninterruptible Power Supplies (UPS), variable-speed drives and lighting controls help conserve energy and increase efficiency. Electrical Hydraulics 2

MV Switchgear Technology is in our DNA Eaton Corporation is a worldwide leader in the design, manufacture, and sale of safe, reliable and high-performance medium voltage power distribution equipment in accordance with IEC, GB and ANSI standards. Complete Global Medium Voltage Switchgear Solutions Eaton, a premier leader in designing and manufacturing power distribution and protection equipment in the electrical industry, offers a comprehensive range of medium voltage (MV) solutions to meet the needs of virtually every application. From products that feature cutting-edge design that allow for easy access, maintenance and space savings, to arc-resistant products that enhance safety, Eaton s medium voltage solutions provide a variety of products for every need. Additionally, Eaton s global service network provides maximum customer support in all regions of the world. As one of the few completely vertically integrated and diversified industrial manufacturers in the world, Eaton designs not only MV assemblies, but also the key components that comprise the MV solutions from steel housing and circuit breaker compartments to vacuum interrupters, circuit breakers, bus systems and fuses. Eaton s MV heritage, strengthened by acquisitions such as Westinghouse DCBU, Cutler Haer, MEM and Holec, has resulted in breakthrough MV technologies and numerous international patents over the years. Integral to Eaton s complete electrical PowerChain Solutions which help businesses increase reliability, efficiency and safety Eaton s medium voltage equipment meets all applicable standards and certifications such as IEC, NEMA / ANSI, GB, UL, IEEE, KEMA and CSA. When it comes to medium voltage solutions, you can trust the one name with a long history of proven performance: Eaton. 3

W-VACi IEC 12 kv, 17.5 kv and 24 kv Reliability, safety and performance in a compact package The new and extensive line of W-VACi compact MV vacuum circuit breakers with IEC ratings of 12 kv, 17.5 kv and 24 kv are part of Eaton s comprehensive global product portfolio. It serves both 50 Hz and 60 Hz end-user segments of the electrical industry such as industrial, coercial, utility, mining, marine and off-shore. The W-VACi circuit breakers are complemented by a full line of accessories and compartment kits for panel builders. In addition, they fit in Eaton s new IEC panel design, Power Xpert UX. UX is available in 600, 800 and 1000 configurations. W-VACi vacuum circuit breakers provide you with: Industry leading vacuum and solid insulation technology Through more than eighty years of innovation and experience, Eaton has developed environmentally friendly vacuum interrupters capable of reliably switching both normal load currents and high stress fault currents. In an effort to increase the dielectric strength of the vacuum interrupter, Eaton has also designed vacuum interrupters that are encapsulated in epoxy resin material. The W-VACi IEC circuit breaker family utilizes this solid insulation technology that has been catering to a wide range of applications for years. Environmentally friendly design Eaton s vacuum and solid insulation technology is free of SF 6 -gas that contributes significantly to the greenhouse effect and associated climate change. Conformance to the latest IEC standards W-VACi IEC circuit breakers are designed and third party tested to the latest IEC 62271-100 and IEC 62271-1 standards. All W-VACi circuit breakers meet or exceed the electrical and mechanical endurance requirements of E2 and M2 in accordance with IEC 62271-100. Reliability, safety, and performance The W-VACi IEC circuit breakers offer numerous safety features for maximum protection. Eaton s extensive innovation and experience in the electrical industry deliver world-class product reliability and quality. Each W-VACi circuit breaker is tested mechanically and electrically before it leaves the ISO 9001 certified factory. W-VACi circuit breakers are compact, userfriendly and cost effective. Versatility and flexibility W-VACi circuit breakers can be used in an extensive scope of applications such as the protection of transformers, capacitor banks, motors, busbar sections and cables. The circuit breakers can be used in special environment conditions such as high altitude, light shock, vibration and high ambient temperature. 4 Power Xpert UX with W-VACi

W-VACi IEC 12 kv, 17.5 kv and 24 kv Building Blocks The W-VACi IEC circuit breakers are comprised of three key building blocks: vacuum interrupter (VI), epoxy resin encapsulated pole unit (EPU), and universal mechanism assembly (UMA). Each building block offers a set of specific benefits to construct a circuit breaker assembly of extreme safety, reliability and performance. + + Vacuum interrupter (VI) Encapsulated pole unit (EPU) Universal mechanism assembly (UMA) Vacuum interrupter (VI) 1 At the heart of the W-VACi IEC circuit breaker portfolio is Eaton s proven vacuum interruption technology and eighty-year expertise in this field. 2 4 5 The vacuum interrupter is where current making and breaking occurs. It houses Eaton-designed high-performance copperchrome contacts, which provide superior performance characteristics. The vacuum in the arc chamber protects the copper contacts from adverse effects such as contamination and corrosion. 3 Negligible contact erosion A principal feature of Eaton vacuum interrupters is the large number of parallel arcs that are created between the contacts during breaking. This diffuse discharge is characterized by very low arc voltage and short arc times, resulting in very low arc energy. Therefore, contact wear in an Eaton vacuum interrupter is negligible. Sealed for life Coitted to delivering proven reliability, safety and performance, Eaton s vacuum interrupting technology is the result of years of research and development. Eaton vacuum interrupters are hermetically sealed and offer extensive vacuum integrity. They are maintenance free. 1 Bellows 2 Bellows shield 3 Ceramic insulators 4 Movable contact 5 Magnetic laminations 5

Encapsulated pole unit (EPU) The W-VACi IEC vacuum circuit breakers use Eaton vacuum interrupters that are embedded in epoxy resin. This assembly is referred to as an encapsulated pole unit (EPU). Durable Encapsulating the vacuum interrupter in epoxy resin results in circuit breaker pole units that are extremely durable. Further, it protects the vacuum interrupter from mechanical impact and climatic conditions such as moisture, humidity and dust. The material is vibration and shock proof and its durability is long lasting. High performance Originally developed for outdoor use, the robust epoxy resin insulating material offers; Optimum thermal conductivity High electrical resistivity Low moisture absorption High creepage current resistance High mechanical strength Complete homogeneity Eaton encapsulated pole units are designed in such a way that no partial discharging occurs on the surface. Compact Due to its mechanical strength, epoxy resin lends itself to a very compact design, when combined with Eaton s world leading vacuum interrupter technology. High current and interruption ratings are achieved in a small package, generating cost savings for users. Encapsulated pole unit (EPU) Universal mechanism assembly (UMA) Designed with reliability and long product life, the W-VACi circuit breaker utilizes a simple spring charged, stored energy mechanism. It is compact and has a limited number of moving parts. Integrated modular design Eaton s universal mechanism assembly (UMA) is a modular design that is coon across all W-VACi circuit breaker frames, making the W-VACi circuit breaker family easy to work with. Customers see no variation between different W-VACi frames, simplifying training, operation and inspection of the circuit breakers. UMA is a self contained functional unit and allows for fast and easy installation. It is manufactured in large quantities and is not sensitive to process variations. Eaton s UMA design requires low energy to operate motor close and trip through the use of special electronic components. All universal mechanism assembly plating is Restriction of Hazardous Substances (RoHS) compliant, offering an environmentally friendly solution. Minimal inspection Due to its modular design, material selection and limited number of moving parts, Eaton s mechanism assembly requires minimal inspection. The simplicity of the design reduces the energy required to operate it, minimizing system wear and the need for inspection. Long life and reliability With its simple and proven design, the universal mechanism assembly has a life of up to 20,000 mechanical operations and does not require inspection up to 10,000 operating cycles. It includes special plating on metal components to increase mechanical life and prevent corrosion. Easy to use To achieve smooth operation, Eaton s mechanism assembly comes with an anti-pump relay as standard. It utilizes simple and clear circuit breaker status indication and requires low manual operation force. UMA has an integrated manual charging handle. It is light and quiet for maximum ease of use. Universal mechanism assembly (UMA) 6

W-VACi IEC 12 kv, 17.5 kv and 24 kv Vacuum circuit breaker The W-VACi IEC vacuum circuit breakers are available globally in both withdrawable and fixed configurations for maximum flexibility. The W-VACi portfolio of products is complemented by a full line of breaker accessories for maximum safety and ease of use. Additionally, Eaton s global service network provides extensive customer support in all regions of the world. W-VACi IEC withdrawable W-VACi IEC fixed L-Frame The L-frame is the interface between the circuit breaker and the switchgear in withdrawable configurations. All W-VACi circuit breakers can be packaged with the Eaton L-Frame by panel builders and OEMs. The L-Frame can be used in all end user segments for installation into new or existing switchgear. Its optimized design and robust construction provide a solution that is safe, reliable and easy to use. Integrating the W-VACi circuit breaker into a switchgear design is simple and cost effective. The W-VACi L-Frame is designed for fast installation by panel builders and OEMs. It ensures full alignment of the circuit breaker contacts with the L-Frame primary contacts that allow for busbar or cable connections. The independently operated shutters are automatically aligned within the L-Frame, facilitating the smooth operation of the shutter mechanism. The shutters can be locked in the closed position for additional safety when the circuit breaker is withdrawn from the switchgear. Integral position contacts and interlocking mechanisms within the circuit breaker racking in assembly ensure smooth and easy insertion. The L-Frame and W-VACi designs allow for the L-Frame to be free of low voltage secondary cables and wires. Circuit breaker position contacts within the racking in assembly provide remote indication of Service or Test / Withdrawn positions. Interlocks prevent the circuit breaker from being inserted or withdrawn unless it is in the Open position. An optional interlock on the breaker racking in assembly is available to provide a door interlock such that the panel door can only be opened with the circuit breaker in the Test / Withdrawn position. L-Frame for withdrawable configurations W-VACi IEC product portfolio overview Circuit breaker designation 12 kv 17.5 kv 24 kv Rated voltage Ur kv 12 17.5 24 Rated frequency fr Hz 50 / 60 Rated normal current Ir A 630 / 800 / 1250 / 1600 / 0 / 2500 / 3150 / 4000 [1] [2] [3] 800 / 1250 / 1600 / 0 / 2500 [2] [3] Rated short-time withstand current Ik ka rms 25 / 26.3 [4] / 31.5 / 40 / 50 [2] [3] 25 / 31.5 / 40 / 50 [2] [3] 20 / 25 [2] [3] Rated duration of short circuit tk s 3 Rated supply voltage V 24-48 - 60-110 - 125-220 - 250 VDC / 120-220 - 230 VAC [3] Pole-center distance 150 210 275 150 210 275 210 275 Upper-to-lower terminal spacing 205 / 275 310 310 205 / 275 275 310 310 310 [1] 4000 A rating with forced cooling [2] See page 10, 11 and 12 for exact technical information and configurations [3] Please contact Eaton for availability [4] Tested at 50 Hz 7

Years of innovation and experience deliver industry leading vacuum circuit breaker technology Eaton has combined global innovation and substantial design investments to deliver a complete IEC vacuum circuit breaker portfolio for all applications. W-VACi vacuum circuit breakers provide you with; Environmentally friendly offering The W-VACi IEC circuit breaker interrupting chamber and pole unit insulation are free of SF6 gas. The mechanism plating is RoHS compliant. The encapsulated pole unit materials are recyclable. User friendly operation The W-VACi circuit breaker controls and position indicators are clearly and functionally grouped on the front of the control panel. They include manual close and trip pushbuttons, closing spring charged/discharged indicator, circuit breaker open/closed indicator and operations counter. All controls are ergonomic for maximum ease of use. The W-VACi circuit breakers are very easy to handle due to low weight and small size. Automatic alignment with easy circuit breaker insertion The W-VACi circuit breaker can conveniently be rolled into the switchgear compartment via guide rails which allow automatic alignment of the primary disconnects. Easy access and minimal inspection The stored energy mechanism and control components are easily accessible and can be inspected by removing the front panel. The location of the mechanism and control components on the circuit breaker also ensures easy inspection. Only minimal inspection is required. Safety, reliability and performance The W-VACi IEC circuit breakers offer several different safety features. The steel shield behind the UMA and the circuit breaker front cover are earthed and offer double layer isolation from the high voltage components when the circuit breaker is energized in switchgear. The circuit breaker can be connected or disconnected with the compartment door closed by utilizing an integral racking device. The manual racking device requires minimal operator force. The optional integral motor operated racking device allows for the breaker to be racked in remotely, offering an added layer of operator safety. The mechanically and electrically trip-free stored energy mechanism design ensures that while holding a mechanical trip coand, the circuit breaker contacts will not close even when an electrical or mechanical close coand is received. Safety interlocks provide the highest level of protection to operators. If the circuit breaker is closed, it cannot be racked in or out. An optional door interlock mechanism on the circuit breaker can be supplied to ensure that the racking of the breaker can only happen when the compartment door is closed. Eaton s world class quality and routine circuit breaker life testing process provide lasting product reliability. The reliability of the vacuum interrupter, encapsulated pole unit and mechanism assemblies ensures that the circuit breaker assembly is of the highest performance standards. Flexible The W-VACi circuit breaker offers field customization with a full range of accessories that allow easy and fast installation. It comes with an integral spring charging handle. In addition, it offers a wide selection of optional accessories for additional features and flexibility. Cost effective The compact size of W-VACi circuit breakers helps reduce Wiring Harness Universal Mechanism Assembly (UMA) Closing Spring Integral Charging Handle Shock Absorber Operation Counter Auxiliary Switch switchgear footprint to achieve reduced building costs. The reliable and simple design minimizes inspection and life cycle costs. In addition, the W-VACi portfolio offers optimized circuit breaker rating combinations and dimensions. This helps reduce users inventory levels and makes circuit breaker selection and ordering easy. Versatile in applications The W-VACi IEC vacuum circuit breaker serves all end-user segments such as industrial, coercial, utility, mining, marine and offshore. W-VACi circuit breakers can be used in a wide range of applications such as the protection of transformers, capacitor banks, motors, busbar sections and cables. The circuit breakers can be applied in special environment conditions such as high altitude, light shock, vibration and high ambient temperature. W-VACi breaker with front cover removed Secondary Disconnect Charging Motor Shunt Opening Release Shunt Closing Release Under Voltage Release Opening Spring Pole Shaft Racking in Assembly W-VACi circuit breaker accessories The W-VACi circuit breaker portfolio is complemented by a full line of accessories that fit all breaker sizes. This reduces inventory parts for customers and simplifies the purchasing process. The W-VACi accessories are easy to mount and wire, minimizing installation time and cost. This feature facilitates accessory changes by the installer or user personnel, eliminating the need for manufacturer modification or outside service companies. 8

Standard accessories Shunt opening release (SO1) Standard This device allows for local or remote opening of the circuit breaker and can operate with both direct and alternating current. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits 70 110% Ua (DC) 85 110% Ua (AC) Opening time 40 ~ 60 ms Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Shunt closing release Standard This device allows for local or remote closing of the circuit breaker and can operate with both direct and alternating current. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits 85 110% Ua (AC) Closing time 25 ~ 60 ms Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Spring charging motor Standard This device charges the mechanism s closing spring electrically. In the event of a loss of power, the mechanism s closing spring can be charged manually. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits Circuit breaker opening: 85 110% Ua Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Breaker auxiliary contacts Standard Standard circuit breakers contain a 10NO / 10NC auxiliary switch. 6NO / 6NC contacts are used by the circuit breaker, therefore 4NO / 4NC contacts are available for the end user. Selection Standard Two switches - 10NO / 10NC IEC Contact Class 1, Rated Continuous Current 10 A, Breaking Capacity 440 W. Power Consumption: DC: 10 A @ 24 V, 6 A @ 48 V, 5 A @ 60 V, 3 A @ 110 V, 2.8 A @ 125 V, 1.8 A @ 220 V, 1.6 A @ 250 V AC: 15 A @ 110 V, 14 A @ 120 V, 10 A @ 220 V, 9 A @ 230 V Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Closing spring signaling contacts Standard This device is used to signal whether the operating mechanism s closing spring is charged or discharged. It uses a micro-switch that allows remote signaling of the state of the closing spring. State of the contacts Open Closing spring charged Closed Closing spring discharged Power Consumption: DC: 4 A @ 24 V, 2.5 A @ 48 V, 2 A @ 60 V, 1 A @ 110 V, 0.8 A @ 125 V, 0.5 A @ 220 V, 0.4 A @ 250 V AC: 10 A @ 110 V, 9 A @ 120 V, 5 A @ 220 V, 5 A @ 230 V Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Position contacts Standard for withdrawable Fitted in the racking assembly, these contacts are used to identify if the circuit breaker is in the service, test, or disconnected position. This device also acts as an electrical interlock to prevent unsafe operations. IEC Contact Class 1, Rated Continuous Current 10 A, Breaking Capacity 440 W. Power Consumption: DC: 10 A @ 24 V, 7 A @ 48 V, 6 A @ 60 V, 4 A @ 110 V, 3.5 A @ 125 V, 1 A @ 220 V, 0.8 A @ 250 V AC: 5 A @ 110 V, 5 A @ 120 V, 2.5 A @ 220 V, 2.5 A @ 230 V Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Racking handle This device is used to manually rack the circuit breaker into the switchgear. One unit of this device can be used for all of the circuit breakers on a particular site. Standard for withdrawable Optional accessories Second shunt opening release (SO2) Optional Like the shunt opening release (SO1), this device allows for local or remote opening of the circuit breaker. It can be supplied by a circuit completely independent from the shunt opening release # 1 (SO1). This device can operate with direct and alternating current. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits 70 110% Ua (DC) 85 110% Ua (AC) Opening time 40 ~ 60 ms Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Undervoltage release Optional This device opens the circuit breaker when there is notable lowering or loss of its power supply. It can operate with both direct and alternating current. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits 35-0% Ua: UVR operates, circuit breaker opens 70-110% Ua: UVR does not operate Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Mechanism electromagnetic interlock Optional This device protects the operating mechanism from being unsafely activated in the event that the control circuit is not energized. Ua (DC) 24-48-60-110-125-220-250 V Ua (AC) 110-120-220-230 V Operating limits 85 110% Ua Continuous Power (Pc) DC = 5 W AC = 5 VA Insulation voltage 0 V, 50 / 60 Hz (for 1 min.) Fixed circuit breaker interlock This mechanical device is used to prevent mis-closing of the circuit breaker by discharging the closing spring when racking the breaker in or out. It is used on fixed circuit breakers that are converted to draw-out circuit breakers by the customer. Optional 9

W-VACi IEC 12 kv, 17.5 kv and 24 kv Technical Data 12 kv Circuit breaker designation 12 kv W-VACi Rated voltage (U r ) kv 12 Rated insulation level Power frequency withstand (U d ) Lightning impulse withstand (U p ) kv 1min 28 kv pk 75 Rated frequency (f r ) Hz 50 / 60 Rated normal current (I r ) A 630 630 800 1250 1250 1600 0 2500 [1] 3150 [1] [2] 25 ka 25-25 25-25 25 - - 26.3 ka 26.3 [3] - 26.3 [3] 26.3 [3] - 26.3 [3] 26.3 [3] - - Rated short-circuit breaking current (I sc ) ka 31.5 ka - 31.5 31.5 31.5-31.5 31.5 31.5 31.5 40 ka - - - - 40 40 40 40 40 50 ka - - - - 50 [1] 50 [1] 50 [1] 50 50 25 ka 63-63 63-63 63 - - 26.3 ka 66 [3] - 66 [3] 66 [3] - 66 [3] 66 [3] - - ka pk - 31.5 ka 50 Hz - 79 79 79-79 79 79 79 40 ka - - - - 100 100 100 100 100 Rated short-circuit 50 ka - - - - 125 [1] 125 [1] 125 [1] 125 125 making current (I ma ) 25 ka 65-65 65-65 65 - - 26.3 ka - - - - - - - - - ka pk - 31.5 ka 60 Hz - 82 82 82-82 82 82 82 40 ka - - - - 104 104 104 104 104 50 ka - - - - 130 [1] 130 [1] 130 [1] 130 130 Rated short-time withstand current (I k ) ka rms Same as rated short circuit breaking current Rated peak withstand current (I pk ) ka pk - 50 Hz / 60 Hz Same as rated short-circuit making current Rated duration of short circuit (t k ) s 3 Rated supply voltage (U s ) V 24-48 - 60-110 - 125-220 - 250 DC / 120-220 - 230 AC DC component (I dc ) % 29 35 Transient recovery voltage related to kv 20.6 short-circuit breaker current (U c t 3 ) ms 61 Rated operating sequence O-0.3s-CO-15s-CO [4] O-0.3s-CO-180s-CO [5] Opening time range ms 50 ± 10 Breaking time range ms 80 Closing time range ms 50 ± 20 Spring charging time seconds 12 Rated cable charging A, class 25 A, C2 25 ka - - - - - - 6.25 - - Rated out of phase breaking 26.3 ka - - - - - - 6.6 - - current (I d ) Assigned for circuit breakers ka rms 31.5 ka - - - - - - 7.9 7.9 7.9 rated > 0 A 40 ka - - - - - - 10 10 10 50 ka - - - - - - 12.5 12.5 12.5 Mechanical endurance class M2 operations 10,000 / 20,000 [1] Electrical endurance class E2 For use in cable-connected systems class S1 Operating temperature range C - 5 + 40 Pole-center distance 150 150 150 150 210 210 210 275 275 Upper-to-lower terminal spacing 205 275 275 275 310 310 310 310 310 25 ka 83-90 91-129 129 - - 26.3 ka 83-90 91-129 129 - - Fixed 31.5 ka - 92 93 94-130 130 216 217 40 ka - - - - 131 131 131 217 218 Weight [6] kg 50 ka - - - - 183 184 185 218 219 25 ka 110-122 122-172 172 - - 26.3 ka 110-122 122-172 172 - - Withdrawable 31.5 ka - 123 123 124-173 173 283 284 40 ka - - - - 173 173 173 284 285 50 ka - - - - 229 230 231 285 286 [1] Please contact Eaton for availablility [2] 4000 A rating with forced cooling [3] Tested at 50 Hz [4] Operating sequence O-0.3s-CO-15s-CO is available on circuit breakers rated 12 kv up to 40 ka and up to 0 A [5] Operating sequence O-0.3s-CO-180s-CO is availabe on ALL circuit breakers rated 12 kv and 50 ka, and all 12 kv circuit breakers rated 2500 A [6] Weights are ± 3 kg depending on breaker configuration 10

Technical Data 17.5 kv Circuit breaker designation 17.5 kv W-VACi Rated voltage (U r ) kv 17.5 Rated insulation level Power frequency withstand (U d ) Lightning impulse withstand (U p ) kv 1min 38 kv pk 95 Rated frequency (f r ) Hz 50 / 60 Rated normal current (I r ) A 630 630 800 1250 1250 1600 0 2500 [1] 3150 [1] [2] 25 ka 25-25 25-25 25 - - Rated short-circuit breaking 31.5 ka - 31.5 31.5 31.5-31.5 31.5 31.5 31.5 ka current (I sc ) 40 ka - - - - 40 40 40 40 40 50 ka - - - - 50 [1] 50 [1] 50 [1] 50 50 25 ka 63-63 63-63 63 - - ka pk - 31.5 ka - 79 [1] 79 [1] 79 [1] - 79 79 79 79 50 Hz 40 ka - - - - 100 100 100 100 100 Rated short-circuit making 50 ka - - - - 125 [1] 125 [1] 125 [1] 125 125 current (I ma ) 25 ka 65-65 65-65 65 - - ka pk - 31.5 ka - 82 82 82-82 82 82 82 60 Hz 40 ka - - - - 104 104 104 104 104 50 ka - - - - 130 [1] 130 [1] 130 [1] 130 130 Rated short-time withstand current (I k ) ka rms Same as rated short circuit breaking current Rated peak withstand current (I pk ) ka pk - 50 Hz / 60 Hz Same as rated short-circuit making current Rated duration of short circuit s 3 Rated supply voltage (U s ) V 24-48 - 60-110 - 125-220 - 250 DC / 120-220 - 230 AC DC component (I dc ) % 29 35 Transient recovery voltage related to kv 30 short-circuit breaker current (U c t 3 ) ms 71 Rated operating sequence O-0.3s-CO-15s-CO [3] O-0.3s-CO-180s-CO [4] Opening time range ms 50 ± 10 Breaking time range ms 80 Closing time range ms 50 ± 20 Spring charging time seconds 12 Rated cable charging A, class 31.5 A, C2 ka rms 25 ka - - - - - - 6.25 - - Rated out of phase breaking current (Id) 31.5 ka - - - - - - 7.9 7.9 7.9 Assigned for circuit breakers 40 ka - - - - - - 10 10 10 rated > 0 A 50 ka - - - - - - 12.5 12.5 12.5 Mechanical endurance class M2 operations 10,000 / 20,000 [1] Electrical endurance class E2 For use in cable-connected systems class S1 Operating temperature range C - 5 + 40 Pole-center distance 150 150 150 150 210 210 210 275 275 Upper-to-lower terminal spacing 205 275 275 275 310 310 310 310 310 kg 25 ka 84-91 92-130 130 - - Fixed 31.5 ka - 93 93 93-131 131 218 219 40 ka - - - - 132 132 132 219 220 50 ka - - - - 185 186 187 220 221 Weight [5] 25 ka 111-123 124-173 173 - - Withdrawable 31.5 ka - 124 124 125-174 174 285 286 40 ka - - - - 174 174 174 286 287 50 ka - - - - 231 232 233 287 288 [1] Please contact Eaton for availablility [2] 4000 A rating with forced cooling [3] Operating sequence O-0.3s-CO-15s-CO is available on circuit breakers rated 17.5 kv up to 40 ka and up to 0 A [4] Operating sequence O-0.3s-CO-180s-CO is availabe on ALL circuit breakers rated 17.5 kv and 50 ka, and all 17.5 kv circuit breakers rated 2500 A [5] Weights are ± 3 kg depending on breaker configuration 11

Technical Data 24 kv Circuit breaker designation 24 kv W-VACi Rated voltage (U r ) kv 24 Rated insulation level Power frequency withstand (U d ) Lightning impulse withstand (U p ) kv 1min 50 kv pk 125 Rated frequency (f r ) Hz 50 / 60 Rated normal current (I r ) A 800 800 [1] 1250 [1] 1600 0 2500 [1] Rated short-circuit breaking current 20 ka 20 - - - - - ka (I sc ) 25 ka - 25 25 25 25 25 20 ka 50 - - - - - ka pk - 50 Hz Rated short-circuit making current 25 ka - 63 63 63 63 63 (I ma ) 20 ka 52 - - - - - ka pk - 60 Hz 25 ka - 65 65 65 65 65 Rated short-time withstand current (I k ) ka rms Same as rated short circuit breaking current Rated peak withstand current (I pk ) ka pk - 50 Hz / 60 Hz Same as rated short-circuit making current Rated duration of short circuit s 3 Rated supply voltage V 24-48 - 60-110 - 125-220 - 250 DC / 120-220 - 230 AC DC component (I dc ) % 29 31 Transient Recovery voltage related to kv 41.2 short-circuit breaker current (U c t 3 ) ms 87 Rated operating sequence O-0.3s-CO-15s-CO O-0.3s-CO-180s-CO Opening time range ms 50 ± 10 Breaking time range ms 80 Closing time range ms 50 ± 20 Spring charging time seconds 12 Rated Cable charging A, class 31.5 A, C2 Rated out of phase breaking current (I d ) 20 ka - - - - - - ka rms Assigned for circuit breakers rated > 0 A 25 ka - - - - 6.3 6.3 Mechanical endurance class M2 operations 10,000 / 20,000 [1] Electrical endurance class E2 For use in cable-connected systems class S1 Operating temperature range C - 5 + 40 Pole-center distance 210 210 210 275 275 275 Upper-to-lower terminal spacing 310 310 310 310 310 310 Weight [2] 20 ka 104 - - - - - Fixed 25 ka - 156 157 157 158 159 kg 20 ka 142 - - - - - Withdrawable 25 ka - 232 233 234 234 235 [1] Please contact Eaton for availablility [2] Weights are ± 3 kg depending on breaker configuration 12

W-VACi Dimensions Withdrawable 12 kv and 17.5 kv 53 638 Pole space 210 743 743 743 743 295 743310 743 295 310 295 310 310 295 295 295 310 310 165 77 165 165 77 77 591 591 165 77 165 165 77 77 591 591 591 591 198 72 50 50 300 850 850 840 840 275 275 275 275 13 835 835 835 14.5 835 835 14.5 459 300 459 300 459 300 459 300 198 198 72 198 72 72 310 198 345 310 72 345 310 345 310 198 72 852 14.5 850 459 459300 840 850 840 275 275 850 275 275 840 850 275 275 840 275 275 740 740 740 747 747 53 310 345 345 740 300 310 747 747 459 300 459 300 459 300 459 300 740 198 72 852 14.5 14.5 14.5 852 747 747 14.5 14.5 852 852 650 650 640 640 210 210210 210 747 747 838 852 14.5 14.5 459 459 300 650 650 640 640 210 650210 210 210 640 210 210 650 640 210 210 747 165 16577 77 165 77 838 747 652 198 198 72 198 72 72 198 72 310 325 310 325 198 310 325 72 310 310 325 50 838 835 14.5 747 310 652 325 838 838 14.5 652 652 325 50 638 652 53 50 50 50 50 652 53 852 14 Pole space 275 Note: Not all breaker configurations shown. For detailed drawings of all available breaker sizes, please contact your Eaton representative. 852 852 14.5 14 85214.5 838 638 50 638 638 345 24 kv 85214.5 852 14.5 366 366 366 366 366 366 366 366 366 850 850 850 850 850 838 850838 838 838 275 838 275 838 275 275 275 275 275 275275 275 850275 850 275 838 850 838 275 275 838 275 275 275 27 50 50 53 638 591 591 591 591 591 591 53 53 53 53 53 295 310 295 310 295 310 708 708 708 708 295 310 708 295 310 708 310 295 167 79 167 167 79 79 310 53 53 838 740 53 591 591 591 602 602 53 53 852 852 14.5 747 53 838 852 359 359 359 359 359 359 650 650 650 650 640 650 650640 640 640 210 640 210 640 210 650 210 210210 210 210210 210 210 210 650 640 650 640 210 210 640 210 210 210 210 167 79 167 167 79 79 602 602 602 53 53 359 359 359 838 838 838 838 838 14.5 14.5 652 14.5 295 647 647 652 652 14.5 14.5 14.5 652 838 838 638 14.5 652 652 14.5 652 602 76 647 647 647 647 647 205 280 647 647 205 280 205 280 154 76 154 154 76 76 205 280 205 205 154 280 280 76 154 154 76 76 437.5 437.5 437.5 437.5 437.5 437.5 437.5 437.5 500 437.5 500 500 500 500 492 500492 492 492 492 492 150 150 500 150 150 150 150 150 150 150 150 500 150 150 492 500 492 150 150 492 150 150 150 150 652 652 14.5 295 295 310 310 14.5 502 14.5 14.5 591 502 502 14.5 14.5 295 310 295 310 295 310 14.5 502 638 708 490 14.5502 502 14.5 502 Pole space 275 638 638 638 638 638 591 591 490 502 502 638 638 490 490 490 490 490 167 16779 79 167 79 490 490 Pole space 210 708 708 Pole space 150

Fixed 12 kv and 17.5 kv 155 155 150 150 150 150 155 44 44 210 210 220 220 155 24 kv 516 516 34 34 34 34 520 588 520 34 588 520 34 588 426 44 44 626 626 281626 310 281 310 281 310 626 626 281 626 310 281 310 281 310 44 426 275 44 436275 436 44 275 436 44 210 210 210 220 210 220 210 210 220 220 516 Pole space 275 607 607 607 520 588 520 588 520 588 25 25 25 25 720 770 720 25 770 720 25 770 432 432 426 432 426 275 436 275 436 275 436 210 210 210 220 210 220 210 210 220 44 44 44 275 436 516 426 426 14 Pole space 210 516 Note: Not all breaker configurations shown. For detailed drawings of all available breaker sizes, please contact your Eaton representative. 220 210 210 445 720 770 720 770 720 770 445 275 27 44 436 44 4 275 275 2 44 44 44 436 436 4 275 275 275 m 275 275 44 275 436 44 275 436 275 44 436 245 245 275 275 275 275 275 245 245 275 275 275 275 275 27 245 245 44 220 210 210 220 516 445 275 436 275 436 275 210436 210 44 275 44 436 275 210 210 436 44 220 210 210 210 210220 720 445 25 770 72025 770445 676 251 310 676 676 251 310 251 310 44 275 436 419 25 607 720 770 25 676 676 251 310 310 676 251 251 310 44 275 436 275 210 210 436 220 210 210 44 419 275 436 44 520 419 588 520 588 419 444.5 444.5 444.5 155 150 150 436 150 150 419 520 419 34 588 520 34 588419 25 720 445 25 770 720 25 770 445 25 6 607 736 736 301736 310 301 310 301 310 155 150 150 275 436 275 436 275 34 412 412 34 720 770 25 676 676 676 251 310 251 310 251 310 275 436 44 275 44 436 275 436 44 150 150 520 419 588 520 588419 34 34 520 588 6 607 607 516 520 588 34 607 607 444.5 444.5 444.5 412 34 607 736 736 301 310 736 301 310 301 310 412 520 588 34 516 516 629 629 251 310 310629 251 251 310 390 440 390 412 440 390 440 629 629 629 251 310 251 310 251 310 25 476 476 236 205 476 236205 205 236 236 205 390 440 390 25 440 390 412 25 440 516 516 516 395 Pole space 275 516 516 395 395 m 395 395 m 516 395 5 Pole space 210 629 251 310 629 629 251 310 251 310 Pole space 150 275 436 44 275 436 44 275 436 44 275 275 275 607 607 607 720 770 720 770 720 770 432 432 432 275 436 275 436 275 436 275 275 275 245 275245 275 275 245 245 275 275 275 245 245

The power of fusion. 1874 1886 1893 1899 1906 1908 1911 1962 1963 1983 1990 1998 1999 There s a certain energy at Eaton. It s the power of uniting some of the world s most respected names to build a brand you can trust to meet every power management need. The energy created supports our coitment to powering business worldwide. From power distribution to power quality and control, Eaton allows you to proactively manage your complete power system by providing electrical solutions that make your applications safer, more reliable, and highly efficient. Visit www.eaton.com/electrical. All of the above are trademarks of Eaton Corporation or its affiliates. Eaton has a license to use the Westinghouse brand name in Asia Pacific. 9 Eaton Corporation.

Eaton s Electrical Sector is a global leader in power distribution, power quality, control and automation, and monitoring products. When combined with Eaton s full-scale engineering services, these products provide customer-driven PowerChain TM solutions to serve the power system needs of the data center, industrial, institutional, public sector, utility, coercial, residential, IT, mission critical, alternative energy and OEM markets worldwide. PowerChain TM solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic, integrated asset throughout its life cycle, resulting in enhanced safety, greater reliability and energy efficiency. For more information, visit www.eaton.com/electrical. Europe, Middle East and Africa Eaton Industries (Netherlands) B.V. P.O. Box 23 7550 AA Hengelo The Netherlands Tel.: +31 74 246 4012 Fax: +31 74 246 4601 SecretariaatCSsystems@eaton.com www.eatonelectrical.com Asia Pacific Eaton Electrical Sector Asia Pacific Headquarters No.3 Lane 280 Linhong Road Changning District Shanghai 335, P.R.China Tel.: +86 21 5 0099 Fax: +86 21 5 0 www.eatonelectrical.com.cn South America Eaton Ltda. Av. Pierre Simon de Laplace, 751 Cond. Techno Park Via Anhanguera, Km 104,5 Campinas - SP - 13069-320 - Brasil Tel.: +55 19 2117 0000 eatonelectricalbrasil@eaton.com www.eaton.com.br North America Eaton Corporation Electrical Sector 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) www.eaton.com 2011 Eaton Corporation All rights reserved PG022060001U / January 2011 The information provided in this document reflects the general characteristics of the referenced products at the time of issue and may not reflect their future characteristics. Eaton Corporation reserves the right to modify the contents of this document and the characteristics of the referenced products without prior notification. Eaton Corporation does not assume liability for potential errors or omission of information in this document.