SERIES. Dirty Environment Oil Coolers ACD

Similar documents
THERMAL SYSTEMS, INC.

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

DCS- series. Classic

GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) HC- series. Classic

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) GLOBAL STANDARD COOLER

AKG 2009 (changes and errors expected) AKG 2010 (changes and errors expected) Water Cooled

Fluid Cooling Mobile AOHM / AOVHM Series

OFFLINE SERIES GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

BYPASS SERIES GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

A global leader in manufacturing highly engineered heat transfer technologies

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

Cooling Systems for Rolling Stock

Compressor Aftercoolers GLOBAL STANDARD COOLER

P-BarSeries BOL AOL. We COOL what you POWER. Plate & Bar Aluminum. Standard. Air-Oil Coolers. Standard. Models. Now featuring Brushless DC Fans

CC3060 TYPE 12 COMPACT CABINET COOLER AIR-TO-WATER FLUSH-MOUNT MODEL

HYDRAULIC MOTOR FAN DRIVEN PRODUCTS

LKI LKI-HYD COOLING. Series. advanced quality customized designs made in europe. Oil/Air heat exchangers. Low noise level. High performance.

FLUID COOLING Shell & Tube EK Series

Cooling systems for rolling stock

C/SSC. FLUID COOLING Shell & Tube C & SSC Series. Features. Materials SSC Series. Ratings Standard. Materials C Series.

Fluid Cooling Industrial COLW Series

Fluid Cooling Industrial & Mobile OCA Series

Viking In-Line Helical Gear Reducers

Oil/air cooler BLK ATEX-3GD

Oil/air cooler BLK. Fluidcontrol

Specification. Oil/Air- Cooling Systems AKG-Range T1 - T11. AKG A World Class Supplier

Fluid Cooling Brazed Plate BPSW Series

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

AOHM. Fluid Cooling Mobile AOHM & AOVHM Series. How to Order. Features. Materials. Ratings

Cooling systems for rolling stock

AKG A World Class Supplier. Your innovative partner to design and supply engineered cooling packages

Oil/air cooler BLK. Fluidcontrol

FLUID COOLING Shell & Tube B Series

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

Off-line filter / cooler unit FGSL

OR STAINLESS STEEL CONSTRUCTION

Low Pressure Filters

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap

AH / AV. Advanced Series Unit Heaters AH / AV. Ruffneck

STREAMLINE SL-V Plus Series. 150 hp and 200 hp Pumps

6/2 WAY DIRECTIONAL VALVE KV (NG 6)

Compact hydraulic power unit Type BKA

Regenerative Turbine Pumps

BASCO PIPELINE AFTERCOOLERS. ...world leaders in heat transfer technology

Vertical Floor Fan Coil Unit (Model FW)

5 to 100 Ton Capacity Custom Capacities Available

Catalog PowrFlowTM PVX Vane Pumps

LK-FCTB August 2010 (Replaces LK-FCTB,April 2007) FPO. Direct Drive Fluid Coolers Technical Guide. Models PFG & RF6

VIKING SPUR GEAR SINGLE PUMPS SERIES SG-04, SG-05, SG-07 AND SGN-05, SGN-07 STANDARD CONSTRUCTION FEATURES

STOCK PRODUCTS CATALOGUE

Vertical Hi-Rise Fan Coil Unit (Model FS)

SPUR GEAR PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1451 Page 1451.

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data

an ISO 9001 Company Bulletin BCPF 100 NEW Design 70 PLUG FANS CHICAGO BLOWER CORPORATION GLENDALE HEIGHTS, ILLINOIS USA

HALLMARK INDUSTRIES INC.

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

LOW PRESSURE FILTERS MF, MFD, MFDS Series Spin-On Filters 250 PSI up to 120 GPM

3:1 MOBILE LUBE PACKAGES (55 gal)

AC Motor Brakes. General Information. Features. Add-On Brakes. Spring Applied Power-Off Operation. Motor Brake Coil Current. Mounting.

Regenerative Turbine Pumps

NH 3. Evaporator. Ammonia Applications Tons MANP

Cooling Experts Around The Globe. Coolers and cooling modules for the automotive industry

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP

Air Cooler Mobile OK-ELD 0-6 with DC motor

Air Cooled Exchangers With Aluminium Cooling Elements DC ELECTRIC HEAT EXCHANGERS

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Safety & Shut-off Blocks

VIKING SG SERIES SINGLE PUMPS (WITH SHAFT SEAL)

PowrFlow PVX Vane Pumps

SPIN-ON FILTERS & ELEMENTS

MJ SERIES LOW SPEED HIGH TORQUE MOTORS

Regenerative Turbine Pumps

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Non Cycling Refrigerated Dryer

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

Oil Temperature Regulator

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

BIROTATIONAL POWER PACK

EVALUATION REPORT 347

FCX TECHNICAL BOOKLET

Transcription:

ACD Dirty Environment Oil Coolers SERIES Low Fouling Series with Non-Louvered Fin Design Standard s with Higher Speed Fans for Compact, Most Economical Selection Low Noise s with Slower Fan Speeds for Reduced Noise Levels and Lower Fan HP Requirements Competitive Pricing Deliveries From Stock THERMAL SYSTEMS, INC. BULLETIN ACDB-2

AKG ACDB-2 6/24/03 1:01 PM Page 2 Standard s HEAT REJECTION Horsepower Removed @ F ETD 300 200 100 80 40 20 10 8 6 4 2 PERFORMANCE DATA STANDARD MODELS ACD SERIES OIL P = 5 PSI = 10 PSI = 25 PSI = PSI SUS OIL ACD 16 ACD 8 ACD 40 ACD 30 ACD 1 ACD 130 ACD 100 ACD 70 ACD 2 NOISE LEVELS db A SCALE AT 1 METER db(a) ACD 8 80 ACD 16 85 ACD 30 85 ACD 40 88 ACD 70 93 ACD 100 94 ACD 130 96 ACD 1 98 Size ACD 8 ACD 16 ACD 30 ACD 40 ACD 70 ACD 100 ACD 130 ACD 1 ACD 2 HP RPM 1/3 32 1/2 32 1/2 1 2 5 7.5 7.5 10 2 4 6 8 10 20 40 80 100 200 300 Motor Frame IEC 63 IEC 71 56C 56C 56C 184TC 213TC 213TC 215TC OIL FLOW - GPM 115/230 ELECTRIC MOTOR DATA SINGLE PHASE Amps 230 V. 2.6 3.4 115-208/230 4.4 115-208/230 6.4 115/230 10.0 230 23.0 Consult Factory THREE PHASE ACD 2 101 200/220 380/440 200/220 380/440 /220 /440 /220 /440 208-230/480 Amps 230V 1.2 2.0 3.4 6.2 13.4 19.2 19.2 25.0

Low Noise s HEAT REJECTION 200 100 80 40 20 10 8 6 4 Horsepower Removed @ F ETD300 PERFORMANCE DATA STANDARD MODELS ACDL SERIES OIL P = 5 PSI = 10 PSI = 25 PSI = PSI SUS OIL ACDL 16 ACDL 8 ACDL 40 ACL 30 ACDL 2 ACDL 130 ACDL 100 ACDL 70 ACDL 1 NOISE LEVELS db A SCALE AT 1 METER ACDL 8 ACDL 16 ACDL 30 ACDL 40 db(a) 62 65 72 74 ACDL 70 79 ACDL 100 80 ACDL 130 85 2 ACDL 1 88 Size HP RPM 2 4 6 8 10 20 40 80 100 200 300 Motor Frame OIL FLOW - GPM ELECTRIC MOTOR DATA SINGLE PHASE Amps 230 V. THREE PHASE ACDL 2 90 Amps 230V ACDL 8 1/4 1700 IEC 63 Consult 230/4 220-380/440 1.0 ACDL 16 1/3 IEC Factory 230/4 1700 71 220-380/440 1.4 ACDL 30 1/2 115-208/230 4.9 /220 /440 2.4 ACDL 40 1/2 115-208/230 4.9 /220 /440 2.4 ACDL 70 208-230/480 3/4 115/208/230 5.3 3.0 ACDL 100 1.5 5.2 ACDL 130 2.0 1140 184TC Consult Factory 7.6 ACDL 1 5.0 230/4 1140 215TC 16.0 ACDL 2 7.5 230/4 1140 215TC 23.0

Selection Procedures The performance curves above are based on the following: SUS Oil. F Entering Temperature Difference (ETD) If your application conditions are different, use the following selection procedure: STEP 1. Determine the Heat Load In most cases you can use 1/3 of the input horsepower. Example: 30 HP Power Unit = 10 HP Heat Load STEP 2. Determine the Actual ETD Desired Entering OIL Temperature Entering AIR Temperature = ETD The entering oil temperature is the highest desired oil temperature. The entering air temperature is the highest anticipated ambient air temperature, plus any pre-heating of the air prior to its entering the cooler. STEP 3. Calculate the Adjusted BTU/hr for Selection Horsepower Horsepower For x = Heat Load Desired ETD Use With Selection Chart CORRECT ON FACTOR 5.0 4.0 3.0 2.0 OIL PRESSURE DROP CORRECTION 1.0 80 100 200 300 400 0 OIL VISCOSITY SUS STEP 4. Select The From The Curves Read up from the GPM to the required heat rejection. Select any model on, or above this point. STEP 5. Calculate Oil Pressure Drop Find the oil pressure drop correction factor and multiply it by the oil pressure drop found on the performance curve. Specifications RATINGS: Maximum Working Pressure...2 PSI Maximum Working Temperature...2 F MATERIALS: Cooler...Alumium Shroud...Powder Painted Steel Fan Guard...Zinc Plated Steel Fan Blade...Polypropylene Blades Aluminum Hub Mounting Brackets...Powder Painted Steel

AKG ACDB-2 6/24/03 1:01 PM Page 1 Dimensions G SAE Fitting Typ. 2 B C (Approx.) D A E F H K L J M MODEL A B C D E F G H J K L M (Approx.) ACD 8 12.44 15.75 14.72 11.30 3.27 0.55 #16 SAE 1 15 16-12 ACD 16 16.26 19.88 15.59 15.08 3.35 0.59 UN-2B 14.53 18.66 3.07 3. 7.36 M8x10 Bolt (4 PL) Approx. Weights Net Shipping 35 45 45 55 ACD 30 20.59 26.38 17.76 19.29 #20 SAE 25.20 6.02 0.59 1 5 8-12 ACD 40 22.44 30.32 18.74 21.18 UN-2B 29.09 4.17 3.74 9.02 M10x20 Bolt (8 PL) 90 125 125 163 ACD 70 28.27 37.01 22. 20.47 9.92 2.09 37.48 195 ACD 100 37.40 40.95 24.76 29.69 9.02 0.59 2 SAE 4-Bolt 41.42 M12x20 3 FLANGE 5.39 7.87 15.47 Bolt ACD 130 37.52 42.91 29.84 35.52 9.13 0.59 43.49 (8 PL) 365 240 405 420 ACD 1 44.09 48.82 30.28 34.72 11.02 0.65 3 SAE 49.29 480 545 4-Bolt ACD 2 57.64 52.76 33.82 43.62 17.56 2.04 FLANGE.55 7.80 10.00 20.00 3 4 x1 1 2 Bolt (8 PL) 0 688 Dimensions are in inches. We reserve the right to make reasonable design changes without notice. Weights are in pounds. Electric motors are totally enclosed, and are not thermally protected. Actual ratings vay with motor brand. Check motor nameplate for actual ratings. Motor RPM is reduced by 1/6 for service. Ordering Information ACD SERIES MODEL SIZE MOTOR DATA CUSTOM FEATURE CODE Standard SELECTED 0=NO MOTOR R=REVERSED AIR FLOW C=CORE ONLY AD=SAE TO NPT ADAPTORS INSTALLED ACDL SERIES 1= SINGLE PHASE H=HERESITE COATING/CORE ASSEMBLY Low Noise 3=THREE PHASE CRN=CANADIAN REGISTRY, 2 PSI 575=575 VOLT CRS=CANADIAN REGISTRY, 1 PSI

Worldwide AKG has been manufacturing high quality coolers and cooling systems since 1919. We have grown to include 10 facilities with over 1400 employees to serve you. Your Business Partner AKG Worldwide Partnership Customer AKG is a complete single source supply for all of your cooling requirements. Choose from both standard and custom engineered products depending on your specific needs. AKG believes in solid long-term business relationships built on partnerships with its customers. AKG places heavy emphasis on development of leading edge technologies, products and finding creative solutions to our customers individual requirements. AKG Thermal Systems, Inc. Mebane Industrial Park 809 Mattress Factory Road P.O. box 189 Mebane, North Carolina 27302-0189 Tel.: (919) 563-4871 Fax: (919) 563-4917 Autokühler GmbH & Co. KG Postfach 1346 D-34363 Hofgeismar Tel.: 05671 / 8 83-0 Fax: 05671 / 35 82 Internet: http://www.akg-gruppe.de E-mail: Info@akg-gruppe.de