Task summary from previous week/proposed Changes:

Similar documents
Task Summary from Previous Week / Proposed Changes:

Task Summary from Previous Week / Proposed Changes:

Abstract. Acceptance Test Plan Draft - TSV 1

PRELIMINARY DESIGN REVIEW. LFEV-ESCM-2014 February 13, 2014

Abstract. GLV Systems Test Plan 1

Maintainability Report

Acceptance Test Report

Lithium Ion Medium Power Battery Design

COMET: Colorado Mini Engine Team Manufacturing Status Review February 3, 2014

Title: Electric Trike

Implementation of a Grid Connected Solar Inverter with Maximum Power Point Tracking

HV/LV Memo. ECE 492 Spring Abstract. Latest Revision: 16 May Prepared by: Brendan Flood

Project Narrative Description

Energy Harvesting Platform

Test Plans & Test Results

Formula Hybrid ESF -- Part 1

Test Plans & Test Results

USER MANUAL W ONBOARD GENERATOR SYSTEM

Abstract. GLV Systems PDR 1

Automotive Diagnostics Using The Controller Area Network (CAN) Denise R. James

Sequential LED Tail Lights For Ford Mustang

G600 PFD/MFD System Instructions for Continued Airworthiness as installed in

Model-Based Design and Hardware-in-the-Loop Simulation for Clean Vehicles Bo Chen, Ph.D.

Portable Li-Ion Battery Charging System Using Wind Power. Shawn Ocorr Trevor Smith Danielle Allen John VanDeLinde

Series 1580 dynamometer and thrust stand datasheet

(Text with EEA relevance)

Solar Powered Golf Cart

STATOIL US OPERATIONS INVOICING POLICY

Mini Mars Rover. Authors: Jay Clark Matt Johnson Jason Boline. Cost: $315. Time Period: 6 months. University of Idaho

RS485 board. EB062

500W Series Instructions for Continued Airworthiness

Contents. Glossary Common terms and definitions

AcuBMS Battery Management System for Rechargeable Lithium-Based Batteries ELECOMP Capstone Design Project

8-bit. Application Note. Microcontrollers. AVR601: Atmel Modular Evaluation Kits for Motor Control Applications. 1.

Group #26 Andrea Solano-EE Juan Valera-EE Manuel Keesee-EE Randall Lay-EE

P1110-EVAL-01. Contents. Lifetime Power Energy Harvesting Development Kit for Battery Recharging User Manual

Artificial Heart Valve Turbulence Measurement Device. Team 12: Drew Seils Shane Tornifoglio

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

White Paper: Pervasive Power: Integrated Energy Storage for POL Delivery

J2VK Valvetronic Exhaust Control System

Electronic Shifter. Lee Redstone V Lewis Weston V Jason Deglint V Group #5. Supervisor Ashoka K. S. Bhat. Due Oct.

Sponsored By: The Boeing Company Evenflo Company Mark Calabrese Matt Civitello Amy Hesse Kimberly Renk

Robust Flight Controller for a Hexcopter

Activant Prelude. Using the Shop Repair Module

EMERGENCY ALERT SERVICE BULLETIN

A Battery Smart Sensor and Its SOC Estimation Function for Assembled Lithium-Ion Batteries

Green Energy Bus Stop Heating System

500W Series Instructions for Continued Airworthiness

Senior Design 1 First Draft. Station. The Smart Solar Powered Cell Phone Charging Station

Innovation Takes Off

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

Ryan Dufrene, Matthew Kreider, Jason Smith, Bao Doan

Centerwide System Level Procedure

Design and Hardware Implementation of a Supervisory Controller for a Wind Power Turbine

Sponsored By: The Boeing Company Mark Calabrese Matt Civitello Amy Hesse Kimberly Renk

Wireless Test Instrumentation for Rotating Parts

Power Conversion. Battery Chargers. Model

TECHNICAL SPECIFICATION

HCSIS, Independent Monitoring for Quality (IM4Q) - Considerations. Date: 07/20/2011

ams.t.andard REVIEW PLAN.

ELM327 OBD to RS232 Interpreter

76th UNECE GRPE session

WHAT S NEW FEATURE LIST

Using Asta Powerproject in a P6 World. Don McNatty, PSP July 22, 2015

1291BL Series Technical Specification Single Axis Position and Rate Table System

Ram Racing CSU Formula SAE

Curriculum Guide Course: Robotic Systems A Course Number: 1770

Syllabus: Automated, Connected, and Intelligent Vehicles

Technical Review Agenda

WHAT S NEW v2.3

5. Effective Date: On the first day of the first quarter, after applicable regulatory approval.

Rescue Zone #1 Rescue Zone #2 Rescue Zone #3. Victim #2. (placement varies) Obstacle. Obstacle Zone #1 1'-0" 1'-8" 1'-8" 1'-8" 1'-0" 8'-0"

Exhibit R-2, RDT&E Budget Item Justification

GC108: EU Code: Emergency & Restoration: Black start testing requirement

SUBJECT: FUEL FITTING P/N AND , VERIFICATION OF.

Allegro Sigrity SI / PI Overview

CRC Project No. CM-136

INTRODUCTION... 3 REQUIREMENTS... 3 SPECIFICATIONS... 4 DESIGN APPROACH... 5 PRODUCT COST ANALYSIS... 7 STATEMENT OF WORK... 8 SCHEDULES...

8000 Series Liquid Flow Meters

ELM327 OBD to RS232 Interpreter

Powerchip Australia Pty. Ltd. Phone : (03) Fax : (03) Digital Adrenaline For Your BMW 116i 2.

TECHNICAL SPECIFICATION

DOWNLOAD OR READ : TIME OUT SHANGHAI PDF EBOOK EPUB MOBI

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

EE 400D. Professor: Gary Hill. SpiderBot Final Documentation. Robot Company

Testing Electrified Drivetrains for Vehicles without the Battery or Engine. Application Reprint of Readout No. 38

ECHO Enhanced Controller Hook Count Application *** Infrared Photo Sensors *** GCA 110 ECHO Controller. Version 3.5

Parametrization of Steering Models and. Analysis of Driving Maneuvers with. MXsteeringdesigner and MXevaluation

High Level Design ElecTrek

TECHNICAL SPECIFICATION

Dr. D. Feszty RUAS Project Manager (CB 3207) Jen Gatenby RUAS Project Integrator ( )

What is entire PressureNET? What are the features of entire PressureNet? What are the benefits of TPMS? Increased Safety.

Interconnection Process for Generation Systems

Explosion-Proof Painting Robots

YOGEV. Hydro-Power Unit. Installation and Operation Guide

Ongo01c Project OSCAR Power

Electromechanical Arithmetic Logic Unit. David Bober E90 Project Proposal 12/2/2008

Michigan Tech. HEV and Mobile Lab Program Update Advanced Power Systems Research Center

Applied Load Testing for WorkoverRigs. Chance Borger Holly Bramer Jacob Wedel

Manufacturing Implications within. new DODI (Dec 8, 2008) Summary for Industry. National Center For Advanced Technologies.

Transcription:

Project Status Letter PSL Number: PSL_04 Covering period: 02/25-03/03 Prepared by: J. Mahati Hari and Rachel Szteinberg Task summary from previous week/proposed Changes: TEAM CURRENT WBS TASKS COMPLETED FURTHER INVESTIGATION PROPOSED CHANGES VSCADA - VSC.4.2. [Maintainability plan delivered ] - VSC.3.5 [CANBus Link Demonstrated ] [+] Drive mode demo added Cell App - CELL.7.2. [Maintainability plan delivered ]? Implemented Data Handler? raw data view [+] management met with team, made sufficient changes DYNO? connection from power supply? Motor characterization test conducted? over- heating temperature changes to software TSV - TSV.1.1 [Calibrated All AMS boards documents delivered ] - TSV.2.1 [Populated and debugged first PacMAN Board] - TSV.4.2 [Tested packs] - TSV.6.1 [Integrate accumulator with dyno] - TSV.6.2. [Dummy load test data plan approved] - TSV.6.3. [Integrated packs in series without AMS or PACKMan boards] - TSV.5.1[Powered dynamometer with accumulator ] - TSV.5.2 [Collected relevant data ] - TSV.7.1 [ PDR delivered] TSI Cooling? COOL.1.3. Electrical Schematic approved [+] reservoir block diagram inclusion

Systems Engineering - M.1.3 [Maintainability plan delivered and accepted ] - VSC.3.5 [CANBus Link Demonstrated ] GLV [+] GLV box interior layout approved [+] GLV box panel approved Interconnect Communications Not referenced with WBS - Website maintained/updated -Photos taken/edited - Footage taken - SCADA Layout Mock-ups edited - Initial research for proposal completed Car Physics Investigation MGMT n/a - M.7.1. [Organized/Maintained the website] - M.11. [Purchasing report created] Not referenced with WBS [+] PSL

Plan for next week: TEAM TASKS TO BE COMPLETED VSCADA - VSC.3.1. [Interfaced with subsystems] - VSC.2.6 [ Drive mode demo delivered] Cell App - CELL.7.3. [CDR delivered] DYNO? RPM CANBus data fixed? run specific tests TSV - GLV.5.2. [ATP delivered] - GLV.6.2. [CDR delivered] TSI - TSI.1.1 [schematic design approved] - TSI.6.2. [ CDR Delivered] - TSI.3.1 [IMD integrated with microcontroller] - TSI.4.1 [Mounting plate design approved by machine shop] - TSI.5.5 [Mounted current sensor bars] Cooling - COOL.4.1 [CANBus Interface Demonstrated] - COOL.3.1 [LCD display delivered] Systems Engineering? CANBus cooling/tsi/huff box Integrated? Reworked CANBus protocol? Work with SCADA for update rates/packet info GLV - GLV.4.2 [GLV_BoB delivered] - GLV.6.2 [CDR delivered] Interconnect - IC.2.1 [Built all GLV safety loop cables ] Communications Car Physics Investigation Not referenced MGMT - M.2. [CDR delivered] - M.5.1.1 [ATP plan delivered] - Deliver PSL

Progress of WBS Items: Subsystem Total Number of WBS Items PSL 1* PSL 2 PSL 3 PSL 4 TSI 30 1 0 1 2 VSCADA 21 2 0 1 2 TSV 28 1 4 2 9 Cooling 20 2 3 3 0 GLV 29 1 2 1 0 Cell App 24 1 2 1 1 DYNO 21 1 0 2 0 Interconnect 12 0 1 1 0 Physics Investigation 14 0 0 0 0 Management 38 0 3 4 2 Overall 237 9 15 16 16 Please see attached PDF of PPT to see graphical representation. This is based off of the current WBS, which is under iterative revision.

Cost Summary: Subsystem Spent this period Spent to date Budget Allocated Budget Remaining TSI $0.00 $144.61 $1,000 $855.39 GLV $0.00 $79.55 $1,000 $920.45 VSCADA $0.00 $0 $50 $50.00 Cell App $0.00 $0 $125 $125.00 Controller Cooling System $0.00 $410.47 $600 $189.53 Interconnect / Cabling / ICD $345.33 $345.33 $1,000 $654.67 Dyno $0.00 $0 $50 $50.00 TSV $0.00 $384.31 $500 $115.69 Physics & Cruise Control $0.00 $0 $0 $0.00 Shipping / Tax / Misc $19.49 $133.18 $1,175 $1,041.82 Total $364.82 $1,497.45 $5,500 $4,002.55 Note: Of the shipping/tax/misc budget, $50 has been used towards printing posters of the system diagram and work breakdown structure, $10 this period for the printing of the rev 0.5 system diagram.

Ideally Spent per Subsystem: 40% Percentage Spent per Subsystem: TSI 14.46% GLV 7.96% VSCADA 0% Cell App 0% Interconnect 34.53% Controller Cooling 68.41% Dyno 0% TSV 76.86% Physics & Cruise Control 0% Shipping / Tax / Misc 11.33%

Ideally Spent Overall: 40% Percentage Spent Overall: 27.23%

Receiving Report: Request #7 GLV Digikey Panel LEDs (Appendix I) Request #8 TSI Digikey Microchip (Appendix I) Request #9 Cabling Mouser Connectors (Appendix III) **Note: Requests 7 and 8 were both sent in the same order but were approved separately The following items were received this period and can be found in the appendices listed above: Req Ordered Received Team Vendor Vendor PN Qty Item Description # Date Date 7 GLV Digikey 350-4050-ND 5 Red LED Panel Indicator 24V 21-Feb-17 27-Feb-17 7 GLV Digikey 350-4053-ND 5 Green LED Panel Indicator 24V 21-Feb-17 27-Feb-17 8 TSI Digikey AT90CAN128-15AZCT-ND 1 IC MCU 8BIT 128KB FLASH 64TQFP 21-Feb-17 27-Feb-17 8 TSI Digikey PA0096-ND 1 Breakout board to convert TQFP to DIP 21-Feb-17 27-Feb-17 8 TSI Digikey MCP2551-I/P-ND 1 IC TRANSCEIVER CAN HI-SPD 8-DIP 21-Feb-17 27-Feb-17 9 Cabling Mouser 571-DT06-3S 15 Connectors 3WAY PLUG GRAY 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-1011-235-0405 17 Connectors 180 DEG STRAIGHT BACKSHELL 4 connect 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-1011-231-0305 11 Connectors 180 DEG STRAIGHT BACKSHELL 3 connect 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-1011-239-0605 15 Connectors 180 DEG STRAIGHT BACKSHELL 6 connect 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-1011-245-0805 10 Connectors 180 DEG STRAIGHT BACKSHELL 8 connect 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-1011-247-1205 6 Connectors 180 DEG STRAIGHT BACKSHELL 12 connect 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT06-8SA 10 Connectors see p/n DT06-08SA 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT06-12SA 5 Connectors SZ 16 DT 12 WAY PLUG 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-W8-S 10 Connectors WEDGE LOCK FOR 8WAY PLUG 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-W12S 10 Connectors WEDGELOCK, DT, 12 WAY PLUG 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT06-2S 10 Connectors DT Plug 2 Way 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT04-2P 10 Connectors DT 2 WAY RECP 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT06-4S 10 Connectors PLUG DT 4 WAY 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-DT04-4P 10 Connectors DT 4 WAY RECP 1-Mar -17 3-Mar-17 9 Cabling Mouser 571-W2-P 10 Connectors WEDGE LOCK FOR 2P REC HOUSING 1-Mar -17 3-Mar-17

Purchase Requests: Request #9 Cabling Mouser Connectors (Appendix II) The following items were ordered this period and can be found in the appendices listed above: Req # Vendor Vendor PN Qty Item Description Ordered Date 9 Mouser 571-DT06-3S 15 Connectors 3WAY PLUG GRAY 1-Mar -17 9 Mouser 571-1011-235-0405 17 Connectors 180 DEG STRAIGHT BACKSHELL 4 connect 1-Mar -17 9 Mouser 571-1011-231-0305 11 Connectors 180 DEG STRAIGHT BACKSHELL 3 connect 1-Mar -17 9 Mouser 571-1011-239-0605 15 Connectors 180 DEG STRAIGHT BACKSHELL 6 connect 1-Mar -17 9 Mouser 571-1011-245-0805 10 Connectors 180 DEG STRAIGHT BACKSHELL 8 connect 1-Mar -17 9 Mouser 571-1011-247-1205 6 Connectors 180 DEG STRAIGHT BACKSHELL 12 connect 1-Mar -17 9 Mouser 571-DT06-8SA 10 Connectors see DT06-08SA 1-Mar -17 9 Mouser 571-DT06-12SA 5 Connectors SZ 16 DT 12 WAY PLUG 1-Mar -17 9 Mouser 571-W8-S 10 Connectors WEDGE LOCK FOR 8WAY PLUG 1-Mar -17 9 Mouser 571-W12S 10 Connectors WEDGELOCK, DT, 12 WAY PLUG 1-Mar -17 9 Mouser 571-DT06-2S 10 Connectors DT Plug 2 Way 1-Mar -17 9 Mouser 571-DT04-2P 10 Connectors DT 2 WAY RECP 1-Mar -17 9 Mouser 571-DT06-4S 10 Connectors PLUG DT 4 WAY 1-Mar -17 9 Mouser 571-DT04-4P 10 Connectors DT 4 WAY RECP 1-Mar -17 9 Mouser 571-W2-P 10 Connectors WEDGE LOCK FOR 2P REC HOUSING 1-Mar -17 Outstanding Orders: None at this time. All orders that have been sent out have been received.

APPENDIX I ECE Department Material Request Course: ECE 492 Req Number: 7 / 8 Professor: Nadovich/Schmult Requested By: GLV (Kyle) & TSI (Jack) Vendor: Digikey Requested Date: 21-Feb-17 Web Site: www.digikey.com Ship By: Ground Phone: 218-681-6674 # Vendor PN Manufacturer PN Description Qty 1 350-4050-ND 6823135141F LED PANEL INDCATOR RED 24V 5 $6.970 $34.85 27-Feb-17 2 350-4053-ND 6823235142F LED PANEL INDCATOR GREEN 24V 5 $8.940 $44.70 27-Feb-17 3 AT90CAN128-15AZCT-ND AT90CAN128-15AZ IC MCU 8BIT 128KB FLASH 64TQFP 1 $12.89 $12.89 27-Feb-17 4 PA0096-ND PA0096 Breakout board to convert TQFP to DIP 1 $15.79 $15.79 27-Feb-17 5 MCP2551-I/P-ND MCP2551-I/P IC TRANSCEIVER CAN HI-SPD 8-DIP 1 $1.05 $1.05 27-Feb-17 Unit Price Total Price Rcvd Subtotal : $109.28 Shipping Fees : $8.99 Grand Total : $118.27

APPENDIX II ECE Department Material Request Course: ECE 492 Req Number: 9 Professor: Nadovich/Schmult Requested By: Cabling (Jeremy) Vendor: Mouser Requested Date: 21-Feb-17 Web Site: http://www.mouser.com/ Ship By: Ground Phone: 800-346-6873 # Vendor PN Manufacturer PN Description Qty Unit Price 1 571-DT06-3S DT06-3S Connectors 3WAY PLUG GRAY 15 $1.220 $18.30 3-Mar-17 2 571-1011-235-0405 1011-235-0405 Connectors 180 DEG STRAIGHT BACKSHELL 4 connect 17 $2.240 $38.08 3-Mar-17 3 571-1011-231-0305 1011-231-0305 Connectors 180 DEG STRAIGHT BACKSHELL 3 connect 11 $3.500 $38.50 3-Mar-17 4 571-1011-239-0605 1011-239-0605 Connectors 180 DEG STRAIGHT BACKSHELL 6 connect 15 $2.480 $37.20 3-Mar-17 5 571-1011-245-0805 1011-245-0805 Connectors 180 DEG STRAIGHT BACKSHELL 8 connect 10 $3.880 $38.80 3-Mar-17 6 571-1011-247-1205 1011-247-1205 Connectors 180 DEG STRAIGHT BACKSHELL 12 connect 6 $3.360 $20.16 3-Mar-17 7 571-DT06-8SA DT06-8SA Connectors see p/n DT06-08SA 10 $7.440 $74.40 3-Mar-17 8 571-DT06-12SA DT06-12SA Connectors SZ 16 DT 12 WAY PLUG 5 $5.080 $25.40 3-Mar-17 9 571-W8-S W8-S Connectors WEDGE LOCK FOR 8WAY PLUG 10 $0.229 $2.29 3-Mar-17 10 571-W12S W12S Connectors WEDGELOCK, DT, 12 WAY PLUG 10 $0.306 $3.06 3-Mar-17 11 571-DT06-2S DT06-2S Connectors DT Plug 2 Way 10 $1.030 $10.30 3-Mar-17 12 571-DT04-2P DT04-2P Connectors DT 2 WAY RECP 10 $0.849 $8.49 3-Mar-17 13 571-DT06-4S DT06-4S Connectors PLUG DT 4 WAY 10 $1.490 $14.90 3-Mar-17 14 571-DT04-4P DT04-4P Connectors DT 4 WAY RECP 10 $1.440 $14.40 3-Mar-17 15 571-W2-P W2-P Connectors WEDGE LOCK FOR 2P REC HOUSING 10 $0.105 $1.05 3-Mar-17 Subtotal : $345.33 Shipping Fees : $9.49 Grand Total : $354.82 Total Price Rcvd