Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Similar documents
Technical data. Standards: IEC/EN BG-GS-ET-15

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Safety door-handle system STS

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Ordering details. BDF 100-➀-➁-➂-ST No. Option Description. ➀ 20 2 NO contacts 11 1 NO contact / 1 NC contact ➁ Selection of the actuator ➂

Solenoid interlock AZM 200 The non-contact interlock.

Safety Switches with Separate Actuator SKC

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Safety switches / Position switches / Command devices

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Safety switches with solenoid and separate actuator

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Operating instructions Solenoid interlock AZM 170

Guard locking systems for the protection of man and machine

Safety switches with solenoid and separate actuator

Safety switches with separate actuator

Safety switches with separate actuator

Installation and Operating Instructions

Position switches FR series

Safety switches for hinged doors

Position switches FR series

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Position switches FD series

LR-LX-LK-LW Safety Switches with separate actuator

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Prewired position switches FF series

Microswitches M series

Position switches FC series

Installation and Operating Instructions

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Floor and fine adjustment switches

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

Safety switches for hinges

1.1. Safety Products. Contents. LS-Titan Safety Interlock Switches. LS-Titan Safety Interlock Switches

Switches with manual reset

Prewired position switches FF series

Pendant control stations 6

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

FL series position switches

Door locking devices. 4 Schmersal Industrial Switchgear

Safety switches for hinged doors

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

SFS-UFS Single Foot Switches

Position Switches Series 8074/2

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Control stations and enclosures Pendant control stations, for control circuits Double insulated, type XAC-A

Safety switches with solenoid and separate actuator

Single foot switches PX and PA series

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Technical Information

Door Interlock Switches

Safety rope switches with reset for emergency stop

SG-B1 SERIES / SG-A1 SERIES

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Single foot switches PX and PA series

HS5E Miniature Interlock Switches with Solenoid

Microswitches MK series

LK Position Switches TECHNICAL DATASHEET.

HS1C Interlock Switches with Solenoid

FOOT SWITCHES

Safety rope switch without reset for simple stop

Miniaturized limit switches

Operating instructions Solenoid interlock AZM About this document. Content

Hinged Safety Door Switch

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

AZM300 More than just a solenoid interlock

HS1L Interlock Switches with Solenoid

IDEM Solenoid Interlock Safety Switches

Safety rope switch with reset for emergency stop

Limit Switches - Limit Type Plastic Body IP65

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Switches Unlimited Phone: * Fax:

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Rope safety switches with reset for emergency stop

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Technical data. Standards: IEC/EN thermoplastic tightening force on nut 22 mm A/F max. 300 Ncm Protection class: IP 67 to EN 60529

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Single foot switches - PX and PA series

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Limit Switch - Prewired Type Metal Body

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Locking Style mm AUTOCAD, STEP, IGES & PDF. Kits Actuator Type Interlock Kit Model * Contact(s) SI-LS42DMSG SI-LS42WMSG

Pendant control stations

Operating instructions Solenoid interlock AZM About this document. Content

Transcription:

1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double insulated X High holding force,000 N Large wiring compartment Power to unlock/power to lock principle Screw terminals or cage clamps or connector 4 cable entries M EX version available AS-Interface Safety at Work available Approvals H 1 ➀-➁➂K➃-➄-➅ No. Option Description Standards: IEC/EN 0947--1; EN ISO 1349-1; EN 10; BG-GS-E-19 Enclosure: glass fiber reinforced thermoplastic, self-extinguishing Actuator and locking bolt: stainless steel 1.41 Protection class: IP7 to EN 09 Contact material: silver Contact type: change-over contact with double break, type Zb, with galvanically separated contact bridges Switching principle: A IEC 0947--1 slow action, NC contacts with positive break Connection: screw terminals or cage clamps or connector Cable type: flexible Cable section: min. 0. mm² max. 1. mm² (incl. conductor ferrules) Cable entry: 4 x M U imp : - screw terminals or cage clamps: 4 kv - connector, 4-pole:. kv - connector, -pole: 0. kv U i : - screw terminals or cage clamps, connector, 4-pole: 0 V - connector, -pole: 0 V I the : - screw terminals or cage clamps: A - connector, 4-pole: 4 A - connector, -pole: A Utilization category: AC-1, DC-13 I e /U e : - connector, 4-pole: 4 A / VAC. A / 4 VDC - connector, -pole: A / 0 VDC Max. fuse rating: A gg D-fuse Positive break travel: 10 mm Positive break force: 10 N for each NC contact fitted U s : 4 VAC/DC, 1 ➀-➁➂K➃-➄-➅ No. Option Description 0/ VAC, 0/0Hz Magnet: 100% ED Power consumption: max. 10 W Ambient temperature: C +0 C Mechanical life: > 1 million operations F max :,000 N Latching force: N for ordering suffix R Classification: Standards: EN ISO 1349-1 B 10d (NC):,000,000 Mission time: 0 years MF d B10d dop x hop n x 0 s/h op 0,1 x n op t cycle Actuators ordered separately (refer to page 1-39) ➀ CC Cage clamp SK Screw terminals S M1 ➁ /03 * 1NO/4NC with connector /1 * NO/3NC with connector 1/03 * 1NO/NC 1/ * NO/3NC with connector 1/1 NO/4NC ➂ Latching force N R Latching force N ➃ Power to unlock A Power to lock ➄ Manual release lateral ED on cover-side EU at the rear Emergency exit lateral D on cover-side U at the rear N Emergency release ➅ 04 U s 4 VAC/DC 0/ U s 0/ VAC * only available in 4V AC/DC models : 4V AC/DC models available with integrated LED. Add suffix G 1-3 For more information, see our online product catalog: www.usa.schmersal.net

Contact variants Contact variants Contact variants with LED Power to unlock Q 13 1 41 4 Power to lock Q A1 1 71 3 A A 13 1 41 4 74 A1 1 71 3 74 NO / 4 NC (1/1) Q P 13 1 41 4 1 3 4 71 7 A1 A Power to unlock 1 1 41 4 Power to lock A1 1 71 3 A A 1 1 41 4 74 A1 1 71 3 74 1 NO / NC (1/03) 1 1 41 4 1 3 4 71 7 A1 A NO / 4 NC (1/1) 1 41 13 4 YE +4 VDC YE + 1 41 4 1 4 71 7 A1 A 3 1 71 4 7 Legend safety guard open / LED on + +4 VDC 0 VDC 4 unlocked / LED on GN NO / 3 NC (1/) 13 1 41 4 1 3 4 71 7 A1 A 1 NO / 4 NC (/03) 1 1 41 4 1 3 4 71 7 A1 A 1 NO / NC (1/03) +4 VDC 1 41 YE YE 3 1 71 4 1 4 7 GN NO / 3 NC (/1) 134 13 1 41 4 1 3 4 71 7 A1 A 134 + 1 1 41 4 1 4 71 7 A1 A Legend 1 safety guard closed / LED on + +4 VDC 0 VDC 4 unlocked / LED on 134 At least one magnetic contact with positive break A must be integrated in the safety circuit. Contact variants show de-energized condition with actuator inserted. Interlocks with power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. he contacts with LED are shown in closed and locked condition. For more information, see our online product catalog: www.usa.schmersal.net 1-37

1..-1/1 1..-1/1 1..-1/1 N Manual release For manual release using M triangular key, available as accessory For maintenance, setting-up, etc. Emergency exit For cases of danger Actuation from within the hazardous area Emergency release For cases of danger Mounting only outside the guarded area 1..-1/1 E. 1..-1/1. 19, 1 19 19 19, 7, 19 19 Manual release For manual release using M triangular key, available as accessory For maintenance, setting-up, etc. Cover-side fitting (ordering suffix ED) or rear fitting (ordering suffix EU) enabled Emergency exit he emergency exit is used if an already locked dangerous area needs to be evacuated Emergency exit by pressing the red push-button Reset by pulling on the red push-button Cover-side fitting (ordering suffix D) or rear fitting (ordering suffix U) enabled Combining the manual release and the emergency exit in different mounting directions is only possible with the following combination: ED/U and D/EU 1-3 For more information, see our online product catalog: www.usa.schmersal.net

,3 Solenoid interlocks ø, Rmin. 10 Rmin. 10 17,, 0, Ø, 3,7 R min. 10 3,7 10, 7 R min. 10 Ø, R min. 10 ø, 3,7 3,7 7 Straight actuator B1E, Rmin. 10 Rmin. 10, 0, Ø, 3,7 R min. 10 41, 7 Rmin. 9 39, Ø, Rmin. 9 3,7 Ø, 4 R min. 9 R min. 9 Straight actuator B1 Actuator with magnetic latch B1-1747 Actuator with centering guide B-177 ø, R min. 10 Actuator with slot lip-seal B1-04 9 7 Shortened straight actuator B1S ø, R min. 10 9 7 Straight actuator B1F Actuator with ball latch B1-03 Shortened straight actuator B1ES R min. 10 R min. 9 3 R min. 9 ø, ø, Flexible actuator B Actuator with centering guide B1-177 Shortened angled actuator BS Straight actuator 1-B1 Straight actuator 1-B1E Straight actuator 1-B1F Flexible actuator 1-B Straight actuator with magnetic latch with slot lip-seal with ball latch with centering guide 1-B1-1747 1-B1-04 1-B1-03 1-B1-177 Flexible actuator with centering guide Shortened straight actuator Shortened straight actuator Shortened angled actuator 1-B-177 1-B1S 1-B1ES 1-BS For more information, see our online product catalog: www.usa.schmersal.net 1-39

1 97 1, 10 10 4, Lockout tag SZ 41-1/- Mounting set MS 1 1 97 1, Lockout tag SZ 41-1/- -477 Slot sealing plug 1 Centering device F. riangular key KEY 7, 0 0, 0 4, 1 1 M 34 Mounting plate MP G-01 plug Lockout tag for SS-01/-03/-0/-0 SZ 41-1 for SS-0/-04/-0/-07 SZ 41- Lockout tag with circular holes for SS-01/-03/-0/-0 SZ 41-1-477 for SS-0/-04/-0/-07 SZ 41--477 Centering device only for AZ -SS and 1-SS : Mounting outside FA-00 Mounting inside FI-00 (Product information see page 1-) Mounting plate MP G-01 Mounting sets MS 1 P MS 1 R/P Slot sealing plug 1 104379 riangular key M KEY plugs on request ( with -pole connector only 4 VAC/DC variant possible!) amperproof screws with unidirectional slots (without drawing) M x 1 10333 M x 103339 M x 0 1033 (Quantity pcs) 1- For more information, see our online product catalog: www.usa.schmersal.net

Solenoid interlocks 1-SS- max. 100 77 max. 100 1 Mounting right-angled 3 1 1 0 max., 10 1 SS-0/-07-R,, 0 0 17, 1 99, 17 10 1, 3 System variants 1-SS-01 1-SS-0 1-SS-03 17 1, 1-SS-04 17 1 Mounting inside Mounting outside 9,,, 17 1 SS-01/-0-R 1-SS-0*, 17 1 3 10 0, 1 17 1-SS-0* 0 1-3 100 17 1 SS-0/-04/-0/-07 9, 1-SS-07 99, 17, 1-3 0 100, 1-SS-0 17 1 0 0 10 1 SS-01/-03/-0/-0 3 1 he drawings are always shown with a view to the switch. Included in delivery Mounting plate for safety switch Actuator incl. mounting plate Emergency handle (for variant -0 and -0 incl. mounting plate) Ordering example o order, first choose the desired safety switch and then the door handle system: for example SK-1/1RK--04 and 1-SS-01 Mounting right-angled to safety guard Ordering suffix -R (only SS-01, -0, -07, 0) Mounting inside with emergency handle door hinge right 1-SS-01 1-SS-0 without emergency handle door hinge right 1-SS-03 1-SS-04 Mounting outside with emergency handle door hinge right 1-SS-0* 1-SS-0* (* only for power to lock) without emergency handle door hinge right 1-SS-07 1-SS-0 For more information, see our online product catalog: www.usa.schmersal.net 1-41