2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly suitable for fitting on hinged doors, aluminium profiles and fencing Actuating head can be turned in 4 steps of 9 Sealing mechanism to prevent the ingress of dirt 2 cable entries Wiring compartment Holding force 1, N 24 VDC 24 VAC 48 VAC 11 VAC 23 VAC Always state required supply voltage when ordering H D 11 4, 72 M2 22 29, 22, 17, 23, Manual release Emergency release For manual release using triangular key For maintenance, setting-up, etc. In case of danger Fitting only within the protected area 8 Schmersal
2.19 AZM 19 range Actuation on de-energisation 11 E1 E2 21 22 33 34 1 NC 2 NC Contacts/ Switch travel 1, 2,3 3, 11-2 2,3 3 31-32 3 2,3 3, With manual release With emergency release AZM 19-11/1rk AZM 19-11/1rkn AZM 19-2/1rk AZM 19-2/1rkn AZM 19-11/1rk AZM 19-11/1rkn Actuation on energisation 11 E1 E2 21 22 33 34 1 NC 2 NC Contacts/ Switch travel With manual release 1, 2,3 3, AZM 19-11/1rka 11-2,3 2 3 AZM 19-2/1rka 31-32 2,3 3, 3 AZM 19-11/1rka Notes Info Circuit diagrams show de-energised condition with actuator inserted ( in switch travel diagram). Actuators must be ordered separately. A selection of suitable actuators can be found in 2.2. Interlocks with actuation on energisation may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. LED version on enquiry Schmersal 9
2.2 Actuators Straight actuator AZM 19-B1 Particularly suitable for sliding doors Compensation for tolerances by means of rubber buffers Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 17 mm, minimum actuating radius in line with the plane of the actuator mm The axis of the hinge should be 7. mm above the top Actuator with front fixing AZM 19-B Particularly suitable for front mounting e.g. on hinged guards Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 2 mm, minimum actuating radius in line with the plane of the actuator mm The axis of the hinge should be 1. mm above the top Adjustable actuator AZM 19-B3/2x1 For very small actuating radii at 9 to or in line with the plane of the actuator Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 27 mm, minimum actuating radius in line with the plane of the actuator 3 mm The axis of the hinge should be 2 mm above the top 13 Schmersal
2.2 Actuators Adjustable actuator AZM 19-B3/1 With actuator preset at 1 for small actuating radii Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 1 mm The axis of the hinge should be 2 mm above the top Adjustable actuator AZM 19-B3/7. With actuator preset at 7. Play of key in interlocked condition approx. mm at 9 to the plane of the actuator 17 mm The axis of the hinge should be 2 mm above the top Schmersal 131
2.21 Accessories Mounting plate MP 19 For simple mounting of an AZM 19 on profile systems M 7 3 14, 178 193 2 24, 1 28 24 4 Additional entry ZPG 19 Cover with Pg cable entry, Triangular key M3 For manual release Part number: Straight: Triangular key M3 (included in delivery) With lever: Triangular key M3-a 132 Schmersal
2.27 Technical data AZM 17-F AZM 17-Z AZM 19 AZM 17i-F AZM 17i-Z Standards: IEC/EN 947--1/DIN VDE-2; EN 188; BG-GS-ET-19 Enclosure material: Glass-fibre reinforced thermoplastic, self-extinguishing Glass-fibre reinforced thermoplastic Actuator and latching bolt: Stainless steel 1.431 Zinc-plated metal / aluminium Protection class: IP IP 7 to IEC/EN 29/DIN VDE 47-1 Contact material: Silver Contact type: Changeover with double break Zb, Changeover with with galvanically separated contact bridges double break Zb with galvanically isolated moving contacts Switching system: A IEC 947--1; B BG-GS-ET-19; slow action, NC contacts with positive break Termination: Removable terminal block with cage clamps Screw terminals for max. 2. mm 2 max. 1. mm 2 cables (including conductor ferrules) Rated impulse withstand voltage U imp : 4 kv 2. kv Rated insulation voltage U i : 2 V 4 V Thermal test current I th : 1 A Utilisation category: AC-1 AC-1; DC-13 Rated operating current/voltage I e /U e : 4 A/23 V 8 A/23 V, A/24 VDC Max. fuse rating: A gl/gg D-fuse 1 A gl/gg D-fuse Positive break travel: 11 mm 2 x 3. mm Positive break force: N for each NC 2 N contact fitted Solenoid duty rating: Continuous operation Rated control voltage U S : 24 VAC/DC 24 VDC; 48 VAC; or 11 VAC/DC, / Hz 11 VAC; 23 VAC or 23 VAC/DC, / Hz Consumption: Max. 1 W Max. 8. W Ambient temperature: C + C C + C Mechanical life: > 1 million operations 2 million operations Holding force F max. : 1, N 1, N Holding force of integral ball latch: Latching force: 3 N Schmersal 13