HRDING PERKINS CORSON ZIEBCH DEWEY CMPBELL WLWORTH McPHERSON EDMUNDS BROWN MRSHLL DY ROBERTS GRNT DEPRTMENT OF TRNSPORTTION PLNS FOR PROPOSED Plotting Date: 03/09/2015 S 000i-452 1 9 trrc11610 1:200 Ploted From - Plot Scale - BUTTE LWRENCE PENNINGTON CUSTER FLLRIVER OTTER VE. RCCOON OTTER RD. DR. MEDE SHNNON RD. STTE SHOP HKON JCKSON EXIT 32 1ST VE. VNOCKER ROD STNLEY JONES MELLETTE BENNETT TODD SULLY HUGHES LYMN POTTER TRIPP GLOVER ST. DICKSON DRIVE C H IC G O N O R T H BEDLE W E STE R N 000i-451 Sturgis HYDE FULK BUFFLO GREGORY HND BRULE CHRLES MIX JERULD SPINK UROR DOUGLS JUNCTION SNBORN CLRK DVISON HNSON HUTCHINSON BON HOMME NN ST. TERRY ST. CODINGTON HMLIN KINGSBURY BROOKINGS MINER LKE MOODY McCOOK YNKTON TURNER JULIE ST. V N O C K E R MINNEHH CLY DEUEL 90 RILROD LINCOLN UNION CREEK 14 STRLINE VE. 79 MYSTIC CIR. CMRO VE. BELIR DR. 000i-451 & 000i-452 MEDE & PENNINGTON COUNTY FURNISH ROD CLOSURE GTES 16B TRUCK ROUTE CTRON 000i-452 BLVD. STTE MINTENNCE YRD 18 19 79 17 20 OLD FOLSOM 1 2-3 4-7 8 9 RD. ELK VLE ROD MRLIN DR. Rapid City INDEX OF S General Layout W/Index Estimate With General Notes & Tables Drop rm Road Closure Gate Details Sign Detail Standard Plates CREEK DR. 20 21 29 28 17 16 20 21.\plans\Snow Gates\title.dgn
ESTIMTE OF QUNTITIES 090W-451 BID ITEM NUMBER ITEM QUNTITY UNIT 632E3203 Flat luminum Sign Nonremovable Copy High Intensity 5.5 SqFt 635E3330 Roadway Luminaire, 250 Watt with Photoelectric Cell 1 Each 900E0048 Furnish Drop rm Road Closure Gate 1 Each ESTIMTE OF QUNTITIES 090E-452 BID ITEM NUMBER ITEM QUNTITY UNIT 632E3203 Flat luminum Sign Nonremovable Copy High Intensity 11.0 SqFt 635E3330 Roadway Luminaire, 250 Watt with Photoelectric Cell 2 Each 900E0048 Furnish Drop rm Road Closure Gate 2 Each SPECIFICTIONS Standard Specifications for Roads and Bridges, 2004 Edition and Required Provisions, Supplemental Specifications, and Special Provisions as included in the Proposal. SCOPE OF WORK The following items to be furnished and delivered to State Maintenance Yards by the Contractor: 1. Drop arm closure gates, flashing arm lights, flasher unit, luminaire, and pole disconnect switch. 2. Flat sheet aluminum signs. State Maintenance Yard locations: Project 090W-451 SD Dept. of Transportation 1100 Otter Rd. Sturgis, SD 605-347-3636 Project 090E-452 SD Dept. of Transportation Rapid City South Yard 5801 S. Hwy. 79 Rapid City, SD 605-394-2244 The Contractor shall notify the Engineer two days prior to time of delivery so correct placement for storage and inventory of materials can be made upon receipt. PERMNENT SIGNING The Contractor shall provide all labor and equipment necessary to furnish permanent signing, and/or as required by the Engineer. The ROD CLOSED signs shall be Type IV as per STM D4956-04. Payment for furnishing permanent signs will be paid for the contract unit price for each type of sign based on sheeting requirements per square foot of sign. FURNISH & INSTLL FLT LUMINUM SIGNS, NON-REMOVBLE COPY HIGH INTENSITY Measurement of sign areas will include payment for the entire sign blank before trimming for rounded corners. This payment for signs designated as Flat luminum Signs shall include all labor (including date decals), equipment, and materials to complete the work, and shall be paid for at the contract unit price per square foot for Flat luminum Sign, Non-Removable Copy High Intensity. ING REQUIREMENTS ll legend and border utilizing the color black shall be vinyl or screen printed black, non-reflectorized material. ll other legend and border shall be of same type of sheeting as the background of the same sign. The ROD CLOSED signs shall be Type IV as per STM D4956-04. ll flat aluminum signs shall be 0.100 sheet aluminum. The side trim moldings shall be painted with a color that matches the color of the sign background sheeting. The color coat shall be preceded by a zinc chromatic primer. Paints shall be approved by the Engineer prior to use. dhesive copy applied directly to sheeted extruded aluminum sign panel background may be substituted for removable copy, if approved by the Engineer. Direct applied adhesive copy located on panel seams shall be neatly cut at the seams and securely adhered to the panels. CCEPTNCE OF SIGN INSTLLTIONS Final acceptance of completed signs will be considered on a sign by sign basis in accordance with Section 5.16 of the Standard Specifications. DTE DECLS The Contractor shall affix a state furnished date decal to each new sign installed. Date decals are self-adhesive weather resistant stickers with removable paper backing, approximately 2 X 2 in size. The date decal displays the last two digits of the year the sign was manufactured (as illustrated) with black numerals on a white background. 15 One decal shall be placed in the extreme lower left corner of the front of each extruded aluminum panel sign, or the extreme lower left corner of the back of each flat aluminum sign. Sign supports or other obstructions shall not block the view of the date decal upon completion of the sign installation. ll costs for installing of date decals on new signs shall be incidental to the contract unit price per square foot for Flat luminum Sign, Nonremovable Copy High Intensity. FURNISH DROP RM ROD CLOSURE GTES GLVNIZING: The gate arm pivots, supports, and guides and all associated hardware shall be galvanized in accordance with STM 123. ll rough edges and burrs shall be ground smooth prior to galvanizing. Cost for drop arm road closure gate pole, gate, switches, transformers, LED signal modules, cube flasher units, cap flasher units, and miscellaneous material required to construct this snow gate shall all be incidental to the contract unit price per each for Furnish Drop rm Road Closure Gate. DROP RM ROD CLOSURE GTE DETILS When the gate is fully raised, the nut and washer shall be placed snugly against the outside of the rear channel and have the ability to be padlocked in place. S 000i-452 2 9
POLES New poles shall be galvanized steel. Galvanizing shall be in accordance with SHTO Specification M111 (STM 123). Steel pole material shall be in accordance with STM 36, 242, 570, 572, 607 or 595 Grade or B. 595 material shall be limited to a 3/8 inch maximum thickness. Steel pole material with a thickness of 1/2 inch to 2 inches, shall satisfy Charpy V-Notch toughness test requirements of 15 ft. lb. at 40 degrees F. The SDDOT Office of Bridge Design shall be contacted for Charpy impact requirements for steel pole material thickness greater than 2 inches. SHOP DRWING ND CTLOG CUTS SUBMITTLS The Contractor shall submit shop drawings and catalog cuts in accordance with Section 985 of the Standard Specifications or in dobe PDF format. dobe PDF submittals shall be sent to the following email addresses: Randy.Sauter@state.sd.us John.Less@state.sd.us S 000i-452 3 9 The steel pole-to-base-plate connection shall be a full-penetration groovewelded connection with a backing ring as described in Table 11.9.3.1-1, Section 4.5 of the current edition of the SHTO Standard Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals. ll poles shall have transformer bases. The transformer base shall be TB3-17. BREKWY BSES LIGHT EMITTING DIODE SIGNL MODULE ON GTE RMS Lamp assemblies are to be manufactured by urora, Part No. 30-944 (or equal) 12vV LED gate lights. 3 lamp assemblies shall be mounted on each gate. The LED signal modules shall be warranted against defects in materials and workmanship for a period of 36 months after the installation of the modules. The manufacturer shall provide this warranty in writing to the Engineer prior to installation of the LED signal modules. statement is required, signed by a Professional Engineer registered in the State of South Dakota, certifying that the breakaway base devices meet the design requirements, including breakaway and structural adequacy, of the "SHTO Specifications for Structural Supports for Highway Signs, Luminaires, and Traffic Signals". The physical testing procedures outlined in Section 8 of the Fifth Edition of the luminum ssociation's "Specifications for luminum Structures" may be used to establish service limits for structural adequacy certification of aluminum breakaway transformer bases and frangible couplings. If requested, test data of production samples to support the certification shall be provided. ll costs for Light Emitting Diode Signal Modules on Gate rms shall be incidental to the contract unit price per each for Drop rm Road Closure Gate. BOLTED CONNECTIONS ll bolts shall conform to STM F 568, Class 4.6, unless designated as HS (High Strength), which shall conform to STM 325M. BOLT TESTING DROP RM ROD CLOSURE GTE LUMINIRES Luminaires shall be 250 Watt High Pressure Sodium, medium, cutoff, type III. Three copies of the isofootcandle charts and utilization curves shall be furnished to the Engineer for approval. The Contractor must get approval from the Engineer prior to installation of the luminaires. The certified mill test reports for all bolts used on the project shall include the test results for all of the testing specified in section 972.2.D of the South Dakota Standard Specifications. Some of these tests are supplemental tests that must be requested at the time the bolts are ordered. It is the responsibility of the Contractor to notify the bolt supplier of these requirements. The approved isofootcandle data for each case shall be used to determine the correct socket position at each site. Each luminaire shall be installed with its lamp socket in the proper position and in a level attitude. Cost for drop arm gate luminaire arms and luminaries shall be incidental to the contract unit price per each for Roadway Luminaire, 250 Watt with Photoelectric Cell. LIGHTNING PROTECTION ll luminaire poles shall be equipped with industrial lightning arrestors compliant with current NEM and UL Standards for lightning arrestors. Cost for ground rods and lightning arrestors shall be incidental to the contract unit price for the corresponding luminaire pole bid item.
DROP RM ROD CLOSURE GTE S 000i-452 4 9 C L LUMINIRE POLE 1-4" S DIRECTED BY THE ENGINEER 1 Plot Scale - 1:40 GTE RM GUIDE CST DPTER RED LED WRNING LIGHT 12 MXIMUM 2 FIBERGLSS GTE RM SECTION 5" X 2 1/2" LUMINUM GTE RM SECTION GTE RM SUPPORT 6 6 1 RETROREFLECTORIZED VERTICL STRIPES LTERNTELY RED & WHITE T 16 INCH INTERVLS COVERING ENTIRE GTE RM C L TRVELED RODWY GTE RM LUMINUM EXTRUSION SLEEVE INSERTED INTO GTE RM FOR 10 CST DPTER BOLT WITH HEX NUT & 2 WSHERS 10 BOLTS REQUIRED PER GTE GTE RM PIVOT PDLOCK IN PLCE WHEN GTE IS RISED. 3/4" X 8" PIVOT BOLT WITH HEX NUT & 2 WSHERS CST DPTER 3" 10 1/2" 1 3/4" 7" 1 3/4" 3/4" 3 3/4" 3" 3 3/4" 1/2" DI. HOLE DROP GTE DETIL 3 1/4" R 7 1/4" 8 1/2" B BR 3" X 1/4" X 2-6 1/2" 4" 100 THRED 3 3/4" R BR 3" X 1/4" X 3" SECURE CBLE TO PIVOT WITH CLEVIS ND CLIP N THIMBLE KIT OR SIMILR METHOD INSURING THT CBLE IS PROTECTED FROM BRSION TCK WELD NUT TO SHFT WORM GER WINCH WITH 1/4" DIMETER CBLE. 1 TON SINGLE LINE VERTICL LIFT MINIMUM CPCITY. FIELD WELD OR DRILL MOUNTING PLTE FOR WINCH INSTLLTION. 1 1/2" 3 3/8" X 1 3/4" HS BOLTS WITH HEX NUT & 2 WSHERS 3/4" SECTION B-B BR 3" X 1/4" BR 3" X 1/4" X 10 1/2" 9 3/4" 4 3/4" 5" 2 3/4" BR 4" X 1/4" X 9 3/4" 3/4" 4" 2 1/2" 3/4" 1/2" DI. HOLE BR 1/2" DI. X 1-9" WITH 2 HEX NUTS & 2 LOCK WSHERS 2 BRS REQUIRED BR 3" X 1/4" BOLT WITH HEXT NUT & 2 WSHERS 4 BOLTS REQUIRED 6" B DROP GTE RM GUIDE DETIL GTE RM 10 1/4" BR 4" X 1/4" SQURE TUBING 1-2 1/4" 45.\plans\Snow Gates\dropgate.dgn 4" X 8" HNDHOLE LIGHTING POLE BREKWY TRNSFORMER BSE FOOTING S DESCRIBED IN FOOTING TBLE DROP GTE PIVOT SSEMBLY SQURE TUBING 1 1/2" X 1 1/2" X 4 BR 4" x 1/4" 4" DROP GTE RM SUPPORT DETIL 1/2" DI. HOLE IN BR (CENTERED) 45 VIEW - BR 4" X 1/4" X 6 3/4" CENTERED ON SQURE TUBING
2-9 1/2" DROP RM ROD CLOSURE GTE S 000i-452 5 9 7/8" DI. HOLE FOR PIVOT BOLT Plot Scale - 1:40 RER CHNNEL VIEW B-B B FRONT CHNNEL B 1/2" DI. HOLE FOR BOLT 9 1/4" 1-0 1/4" 9 1/4" RER CHNNEL FRONT CHNNEL 2" 2" X 4" SLOT 4" PIN-BR 1 1/2" DI. WINCH MOUNT 6" X 1/2" X 1-1 3/4" PIN BRCE VIEW C-C 3/4" 1-5" 1-1 3/4" 1-3 3/8" 2" R FRONT CHNNEL 7/8" DI. HOLE IN ND CHNNELS 1 3/4" DI. HOLE FOR PIN 1-3 3/8" 9 1/4" 4 1/4" 3" 2" 2 1/2" 2 1/2" 2" R RER CHNNEL 6 7/8" 6 7/8" 1-1 3/4" DETIL 2" 3" 4 1/4" 9 1/4" 1-5" 1-1 3/4" 2-6 3/4" BOLT WITH HEVY HEX NUT & 2 WSHERS 5" 5" 1/2" DI. HOLE FOR WINCH CBLE CLEVIS 10" C C VIEW - BOLT WITH HEX NUT & WSHER WELD BOLT HED TO SLEEVE DRILL BOLT TO CCEPT PD LOCK 1-2 1/2" 2" PIN BRCE PIN SLEEVE 1-1 3/4" 7 3/4" 6" 2" BOLT WITH HEX NUT & 1/2" DI. HOLE IN SLEEVE @ 3 EQUL SPCES WELD NUT TO SLEEVE. (TYP TOP & BOTTOM) WINCH MOUNT PIVOT SLEEVE DETIL 1-9 3/4" 11 3/4".\plans\Snow Gates\dropgate.dgn
DROP RM ROD CLOSURE GTE S 000i-452 6 9 Plot Scale - 1:40 LUMINIRE MST RM 8 RM LENGTH X 2-9" RISE ROTTED 25 DEGREES ROD CLOSED FLSHER & TRNSFORMER STEEL LUMINIRE POLE CLOSURE GTE SUPPORT POLE DISCONNECT SWITCH CLOSURE GTE GTE RM JUNCTION BOX.\plans\Snow Gates\dropgate.dgn FROM SERVICE POINT TO DVNCED SIGNING TYPICL RISED POSITION TYPICL ELECTRICL EQUIPMENT CONFIGURTION
DROP RM ROD CLOSURE GTE S 000i-452 7 9 Plot Scale - 1:40 GTE RM GUIDE 14.3 31.9 C L TRVELED RODWY 1.1 6.6 6.6 LEVEL.\plans\Snow Gates\dropgate.dgn 4.4 ROD CLOSED 11 WEIGHT OF THE LUMINIRE POLE, LUMINIRE, ND HRDWRE FOR THE ROD CLOSURE GTE SHLL DRILLED SHFT FOUNDTION BOTTOM OF POLE BSE PLTE NOT EXCEED 1,000 POUNDS 11 16.93 1.1 TYPICL LOWERED POSITION
levels:gscolorfill GSBWFILL GSOUTLINE panelstyle:regulatory.ssi constructpanels:36 24 18 constructpanelmode:0 panelroundcorners:0 panelstation:none panelheightlock:1 SIGN DETILS S 000i-452 8 9 1:40 SIGN NUMBER WIDTH x HGHT. R11-2 Special 5-6" x 1-0" BORDER WIDTH 0.63" CORNER RDIUS 1.13" MOUNTING Drop rm Gate BCKGROUND TYPE: IV COLOR: White LEGEND/BORDER TYPE: Non-Reflective 1-0" 5-6" 3" 6"D COLOR: Black/Black 5.5" 55" 5.5" 3" SYMBOL ROT X Y WID HT Panel Style: regulatory.ssi Dimensions are in inches.tenths Letter locations are panel edge to lower left corner LETTER POSITIONS (X) LENGTH SERIES/SIZE R 5.5 O 10.4 15.5 D 21.5 25.6 C 31.6 L 37 O 41.5 S 46.6 E 51.7 D 56.5 55.1 D 2000 6.\Snow Gates\SignDetails.dgn Plot Scale - 1:4
S 000i-452 9 9.\plans\Snow Gates\StdPlate.dgn Plot Scale - 1:200