INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

Similar documents
USER INSTRUCTIONS FOR SLIDING DOORS

Ditec LUXO Swing gates automation (Original instruction)

Sliding doors SL4 series

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Ditec CUBIC Swing gates automation

Sliding doors SL5 series

Ditec BOX Balanced up and over doors

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Sliding Door Automation For escape routes and emergency exit

Ditec PWR25H/35H Automation for hinged gates

Ditec PWR50H/HV/HR Automation for swing gates

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

Ditec QIK4E-7EH-7YEH Electromechanical barrier (Original instructions)

Ditec QIK80EH Electromechanical barrier. IP2085EN Technical Manual. (Original instructions)

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

Ditec DOD Industrial sectional door automations

Telescopic Sliding doors SLT series

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

IP2160 EN. Ditec NEOS Sliding Gates. Technical Manual. (Original instructions)

Ditec VALOR HH-HS IP2063EN. Technical manual Sliding doors automation for hospitals and heavy sliding doors (Translation of the original instructions)

Automation Swing Gate Opener

QIK4E-QIK7EH. Installation and maintenance manual for electromechanical barrier. (Translation of the original instructions) IP1861EN- rev.

Ditec SPRINT Swing doors drive unit

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Ditec VALOR Sliding doors automation (Original instructions)

E R A I GATE AUTOMATION DIVISION

EC DECLARATION OF CONFORMITY

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

INSTRUCTIONS FOR INSTALLATION

Entrematic Ditec Sprint 24V

DOCUMENT TYPE = FITTING INSTRUCTIONS ORIGINAL LANGUAGE = ENGLISH. Maximum door weight = 40kg per leaf total system 80kg

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

FORCE SPD 800/1500/2000

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

Ditec CROSS18-19 Sliding gates automation. IP1984 EN Technical Manual. (original instructions)

Over Over Evo Over Heavy

Automatic concealed bollards 275 H600 and 275 H800 Control station

Ditec E1A. IP2045EN Technical manual. Control panel installation manual for one motor automation with built-in radio.

Rex. Manuale di installazione e manutenzione per porte scorrevoli. Installation and maintenance manual for sliding door

Installation Manual. Swing Gate System. Leading the way...

Mod: KLD6-12/35XLAS-N

Automatic concealed bollards 275 H600 and 275 H800 with pit

IN-GROUND OPERATOR FOR SWING GATES FROG SERIES INSTALLATION MANUAL FROG-A 230V

MOUNTING AND CONNECTING INSTRUCTIONS 1. GATE ARRANGEMENT ENGLISH

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

FEATURES AND SPECIFICATIONS

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Maximum Weight = 80 kg for 2 doors; Maximum door width = 1100mm (to suit up to maximum 2120mm clear opening) Quick Start. 5 & 4mm Allen keys.

unipark Parking space saver operator for single CAR space. Gearmotors 24 V DC

Myto BELOWGROUND AND ABOVEGROUND OPERATOR FOR SWING GATES

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

Quick Start. Flat head screwdriver. Wheel carriage x 2. M8 Nut x 2. Strap Bolt x 2. 1 x 2m Anodised Track

SLIDE NEW CONTROL BOARD

Bowl feeder WV401-1 / Translation of operating and installation instructions

Cross14, Cross14E, Cross14VE, Cross15V

Typical Installation Schematic

ISTRUCTION MANUAL Italian Movements Italian Movements

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

BISON 20 OM BISON 25 OTI

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

TECHNICAL CATALOG NEPTIS INVERS/INVERS-B ELECTRO-MECHANICAL OPERATOR FOR AUTOMATIC SWING DOORS, WITH SINGLE/DOUBLE LEAF

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

Switching DC Power Supply

ECO PLUS RAPID DOOR USER S AND INSTALLER S MANUAL

BULL 424 ESA BULL 624 ESA

FITTING AND CONNECTION INSTRUCTIONS

USE AND MAINTENANCE MANUAL

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

OPERATION & MAINTENANCE INSTRUCTIONS

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

230V DIESEL FUEL TRANSFER PUMP MODEL NO: DFT230

BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072

GENERAL SAFETY... 3 PARTS LIST...

Ditec SPRINT Automation for swing doors

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

Inclined platform lifts RPsp/Supra Product presentation

PURE SINE WAVE DC TO AC POWER INVERTER

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

VIS IRREVERSIBLE ELECTROMECHANICAL MOTOR FOR SECTIONAL DOORS. Rev /2011 RT

CE DECLARATION OF MACHINE CONFORMITY

Compact System NRGS 11-2 NRGS Original Installation Instructions English

SUBWING 700 USER S AND INSTALLER S MANUAL V1.0 REV. 04/2017

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety

INDEX CE DECLARATION OF CONFORMITY FOR MACHINES... 2 WARNINGS FOR THE INSTALLER DESCRIPTION AND TECHNICAL SPECIFICATIONS...

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

CHECKING AND MAINTENANCE:

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

BAYT 980. Oil-hydraulic OIL-HYDRAULIC BARRIER FOR TRAFFIC CONTROL INSTALLATION MANUAL. code 4425 Post with fixing base. POLO 44 - optional -

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

PNEUMATIC PUMP Series

OPERATION & MAINTENANCE INSTRUCTIONS

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

Transcription:

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212 FACE S.r.l. Viale delle Industrie, 74 31030 Dosson di Casier Treviso Italy

INDEX Subject Page 1. General safety instruction 2 1.1 EC marking and European directives 2 2. Technical data 3 3. Standard Installation 3 4. Installation and start-up procedure 5 5. Electrical connections 6 5.1 General safety electrical precautions 6 5.2 Single and centralized multilevel commands 7 6. Troubleshooting 8 7. Routine maintenance plan 8 7.1 Disposal of products 8 All data and information contained in this manual have been drawn up and checked with the greatest care. However FACE cannot take any responsibility for eventual errors, omissions or inaccuracies due to technical or illustrative purposes. FACE reserves the right to make changes and improvements to their products. For this reason, the illustrations and the information appearing in this document are not definitive. This edition of the manual cancels and replaces all previous versions. In case of modification will be issued a new edition. 1 AVVERTENZE GENERALI PER LA SICUREZZA This installation manual is intended for professionally competent personnel only. Before installing the product, carefully read the instructions. Bad installation could be hazardous. The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of children, as these are a potential source of hazard. Before installing the product, make sure it is in perfect condition. Do not install the product in an explosive environment and atmosphere: gas or inflammable fumes are a serious hazard risk. Before installing the automations, make all structural changes relating to safety clearances and protection or segregation of all areas where there is risk of being crushed, cut or dragged, and danger areas in general. Make sure the existing structure is up to standard in terms of strength and stability. FACE is not responsible for failure to use Good Working Methods in building the frames to be motorised or for any deformation occurring during use. 1.2 MARCATURA CE E DIRETTIVE EUROPEE FACE automations are CE-marked designed and built in compliance with the requirements of the following European directives: Electromagnetic Compatibility Directive (2014/30/UE) and Low Voltage Directive (2014/35/UE). D134 EN 20180701 2 www.facespa.it

2. TECHNICAL DATA Features KAF212 Product dimensions: Height x Depth x Max lenght 50 x 68 x 1200 mm Maximum load: 30 kg (1 leaf) / 60 kg (2 leaves) Opening and closing speed 12 s/180 Duty class Intermittent operation Light operation S3 = 15% Power supply Rated power 230 Vca 50/60 Hz 20 W Rated load 23 Nm Protection Rating IP 44 Operating temperature Electrical connections Power output for accessories -15 C +50 C Dedicated connecting terminals 12 Vcc / 100 ma 3. STANDARD INSTALLATION Rif. Code Description 1 K525A12 Support profile and cover profile, anodized aluminum 1200 mm 2 AFQ Electronic control 3 AFM Gearmotor 12V 4 AFB1 Articulated arm with sliding guide D134 EN 20180701 3 www.facespa.it

D134 EN 20180701 4 www.facespa.it

4. INSTALLATION AND START-UP PROCEDURE 4.1 Cut the aluminum profile to size L 10 mm and fix it on the top, about 10 mm from the leaves in the closed position, by means of screws not supplied. Note: insert the fixing nuts of the motors and the electronic controls within the aluminum profile. Leave space on the side, for the passage of the power supply cable and the other cables. Figure 1 4.2 Fix the sliding guide to the leaf of the shutter, as shown in figure 1. 4.3 Fix the electronic control in the middle, using the provided screws. 4.4 Fix 1 or 2 gearmotors on the side, using the provided screws. 4.5 Assemble the articulated arms (as indicated in the figure 2), and fix them to the gearmotors and to the sliding guide. Note: do not tighten the screws, so as to enable the manual rotation of the articulated arms. Figure 2 4.6 Move the (A) position of the gearmotors and adjust the length of the articulated arms, so as to get the correct opening and closing of leaves, as indicated in chapter 3 (if necessary, cut the excess part of the articulated arm). After the adjustment, tighten all screws of gearmotors and articulated arms. 4.7 Make the electrical connections, as described in chapter 5. 4.8 After adjusting the correct position of the gearmotors, insert the side covers in correspondence with the articulated arm (as shown in figure 3). Cut the aluminum cover to the size L 330 mm and fix it centrally, so as to get the complete closing of the automation. Figure 3 4.9 Give power supply. Give opening and closing commands, and verify the correct operation and the correct overlapping of leaves. Grease the pivot inside the sliding guide. Note: verify that the fastening screw of the articulated arm to the gearmotor is tightened in such a way that, during operation, the motor force does not cause slippage of the articulated arm. Also check that, in case of power supply failure, it is possible to move the leaves manually. 4.10 Manual handling of the leaves. In case of power supply failure, if the leaves do not move manually, loosen the fastening screw of the articulated arm (as shown in the figure). D134 EN 20180701 5 www.facespa.it

5. ELECTRICAL CONNECTIONS Connect the red wire of the right motor to the negative terminal (-), and the red wire of the left motor to the positive terminal (+), as shown in figure. Terminals N / L Description Power supply input 230 Vac 50 Hz (by cable not supplied by us). Connect the ground wire to the aluminum profile using the supplied screw. / + Motor 1 Motor 1 input, in the case of 2 leaves, connect the motor which opens first. Note: in the case of single leaf, the motor must be connected to the Motor 1 input. / + Motor 2 Motor 2 input, in the case of 2 leaves, connect the motor which opens second. Note: in the case of single leaf, the motor must be connected to the Motor 1 input. 0 1 (+12V) Output 12 Vcc (max 100mA) for external powering accessories (for example a radio receiver). C 4 C 3 C G1 C G2 Closing contact N.O. Opening contact N.O. Note: a further contact performs partial opening. General closing contact N.O.; with a single command you can close all automations connected. General opening contact N.O.; with a single command you can open all automations connected. 5.1 GENERAL SAFETY ELECTRICAL PRECAUTIONS Installation, electrical connections and adjustments must be completed in conformity with Good Working Methods and with regulations in force. Before making power connections, check that the rating corresponds to that of the mains supply. A multipolar disconnection switch with a contact opening gap of at least 3 mm must be included in the mains supply. This switch must be protected from unauthorized activations. Check that upstream of the electrical installation an adequate residual current circuit breaker and an overcurrent cut out are fitted. When requested, connect the automation to an effective earthing system carried out as indicated by current safety regulations. The connection to the mains supply in the outer portion automation, should be an independent channel, separated from the connections to control devices. Make sure there are no sharp edges that could damage the power supply cable.. During installation, maintenance and repair operations, cut off the power supply before opening the cover to access the electrical parts. To handle electronic parts, wear earthed antistatic conductive bracelets. FACE declines all responsibility in the event of components which are not compatible with the safe and correct operation of the product. For repairs or replacements of products only original spare parts must be used. D134 EN 20180701 6 www.facespa.it

5.2 SINGLE AND CENTRALIZED MULTILEVEL COMMANDS D134 EN 20180701 7 www.facespa.it

6. TROUBLESHOOTING Problem Possible causes Remedy The automation does not open or close. The automation opens but does not close, or closes but does not open. No power supply. The leaf is locked by bolts and locks. The opening or closing devices are activated. Check the power supply. Check the freely move of the leaves. Check for centralized controls connected to the G1/G2 terminals. 7. ROUTINE MAINTENANCE PLAN Except for routine cleaning of the door and any outer slides automation, the responsibility of the owner, all maintenance and repair work must be carried out by qualified personnel. Task Remove the power supply, open the automation and perform the following checks and adjustments. - Check all screws fastening of components within the automation. - Check the wear of the hinges of the leaf and articulated arms. - Grease the pivot inside the sliding guide. - Check the electrical connections. Connect the power supply and perform the following checks and adjustments. - Check the correct operation of the automation and the proper handling of the leaves Frequency Every 6 months. Every 6 months. For repairs or replacements of products, original spare parts must be used. 7.1 DISPOSAL OF PRODUCTS The packaging materials (cardboard, plastic, and so on) should be disposed of as solid household waste, and simply separated from other waste for recycling. Our products are made of various materials. Most of these (aluminum, plastic, iron, electrical cables) are classified as solid household waste. They can be recycled by separating them before dumping at authorized city plants. Whereas other components (control boards, batteries, and so on) may contain hazardous pollutants. These must therefore be disposed of by authorized, certified professional services. Before disposing, it is always advisable to check with the specific laws that apply in your area. DO NOT DISPOSE IN THE ENVIRONMENT. FACE S.r.l. Viale delle Industrie, 74-31030 Dosson di Casier (TV) Italy Fax +39 0422 380414 \ Phone +39 0422 492730 E-mail: info@facespa.it \ www.facespa.it D134 EN 20180701 8 www.facespa.it