Rheem High Efficiency Air Handler

Similar documents
Ruud High Efficiency Air Handler

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

FORM NO. HSC-543 AIR HANDLERS

Rheem High Efficiency Air Handler

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

ELECTRIC HEAT AIR HANDLERS

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Cased/Uncased Coils For Gas And Oil Furnaces

Rheem Classic Plus Series Downflow Gas Furnace

Rheem Classic Series Downflow Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

ELITE SERIES R-410A Ready - Multi-Position

Rheem Classic Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Two-Stage Downflow/Horizontal Gas Furnace

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

INDOOR COILS. RCFM- featuring New Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Rheem Classic Series Upflow/Horizontal Gas Furnace

CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

AIR CONDITIONERS WA16 SERIES

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

INDOOR COILS RCBA-/RCHJ-/RCHL- MULTIFLEX CASED OR UNCASED INDOOR COILS. AIRFLOW CAPACITIES CFM [ L/s]

Rheem Value Series Downflow Gas Furnace

RCBA- MULTIFLEX INDOOR COILS

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

Rheem Classic Plus Super Quiet 80 Upflow/Horizontal Gas Furnace

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

FEM4P, FSM4P, FSU4P. Product Specifications

Q7RE Series Single Packaged Heat Pump, Single Phase

ELITE Series R-410A - Upflow / Horizontal

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

Package Air Conditioners

FEM4X, FSM4X, FSU4X. Product Specifications

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

135 (61) FVM4X2400AT. (416 x 546) FVM4X3600A FVM4X3600AT FVM4X4800A FVM4X4800AT FVM4X6000A FVM4X6000AT 1400 (661) 1600 (755) 2000 (944)

Dimensions Filter Size in. (mm) lbs. (kg) FVM4X2400B 135 (61) FVM4X2400BT

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Q7RE Series Single Packaged Heat Pump, Single Phase

Modular Variable Speed Air Handlers

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

AIR CONDITIONERS WA14**A SERIES

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

FMU4X, FMC4X FMU4Z, FMC4Z

P5RF Series Single Packaged Air Conditioner Single Phase

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

Product Data. Convertible Air Handlers 1 1/2 5Ton

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

DESCRIPTION FEATURES

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5 Ton D-EN. September 2016

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

CFM Range Tons x 21 1 / 8 x x 21 FVM*X4800A 48, FVM*X6000A 60, x 24 x x

CONDENSING UNITS RAKB- SERIES. Seven Models

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

14 SEER R -410A PACKAGE GAS / ELECTRIC UNIT 2 to 5 TON

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

DUAL COMFORT CONTROL TWO-STAGE DOWNFLOW/HORIZONTAL GAS FURNACES WITH

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

EBP. Product Specifications. EBP Fan Coils 2 THRU 5 TONS SPLIT SYSTEM FEATURES. Model Number

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Multi-Position Air Handler. 1½ to 5 Tons. with Energy-Saving Motor

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P7RE Series Single Packaged Air Conditioner

P7RE Series Single Packaged Air Conditioner

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Transcription:

Air Handlers Rheem High Efficiency Air Handler Constant Torque Motor (ECM) Efficiencies up to 14 SEER The RH1T feature a Constant Torque motor (ECM) and a piston refrigerant control for efficient and reliable operation. Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right applications. Factory-installed indoor coil. Sturdy cabinet construction with 1.0 inch [2.4 mm] of foil faced insulation for excellent sound and insulating characteristics. Field-installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include circuit breakers which meet U.L. and cul requirements for service disconnect. 1 1 /2 ton [.3 kw] through ton [17.6 kw] models are between 42 1 /2 to 7 inches [1080 to 1448 mm] tall and 22 inches [9 mm] deep. All models meet or exceed 330 to 400 CFM [16 to 189 L/s] per ton at.3 inches [.7 kpa] of external static pressure. Enhanced airflow up to.7" external static pressure. Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing. Suitable for application in mobile homes. FORM NO. H11-9 REV. 1

Table of Contents TABLE OF CONTENTS Engineering Features...3 Model Number Identification...4 Dimensional Data...-6 Airflow Directional Data...7 Airflow Performance Data RH1T...8-10 Electrical Data RH1T...11-13 Electrical Wiring...14 Accessories...14 Limited Warranty...1 2

Engineering Features Engineering Features The most compact unit design available, all standard heat air handler models only 42 1 /2 to 7 inches [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Piston refrigerant control on indoor coil provides for reliable operation when matched with the RP14 Piston Heat Pump. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check. Coils have copper sweat refrigerant connections. Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2 inches [1 mm] for 1 1 /2 inch [38 mm] conduit. Front refrigerant and drain connections. TXV Shown 3

Model Number Identification R H 1 T 24 17 S P B N A A *** Option Code (see ADS-3803) Blank = None Minor Series A = First Voltage A = 11/1/60 D = 480V/3/60 J = 208/240/1/60 Controls C = Communicating N = Non-Communicating Major Series A = First B = 2nd Metering Device T = TEV E = EEV P = Piston Coil Efficiency S = Standard M= Medium H = High Width 17 = 17." [431.8 mm] (600-1200 CFM) 21 = 21" [33.4 mm] (800-1600 CFM) 24 = 24." [609.6 mm] (1400-1800 CFM) Nominal Capacity 24 = 18,000 [.27 kw]-24,000 [7.03 kw] BTU/H 36 = 30,000 [8.79 kw]-36,000 [10. kw] BTU/H 48 = 42,000 [12.31 kw]-48,000 [14.06 kw] BTU/H 60 = 60,000 [17.8 kw] BTU/H Motor Type T = Constant Torque (ECM) Stages of Air Flow 1 = Single 2 = Two Stage Product Category H = Air Handler Rheem Available Models at 11V A Voltage RH1T2417SPBNAA RH1T3617SPBNAA RH1T4821SPBNAA Available Models at 208V J Voltage RH1T2417SPBNJA RH1T3617SPBNJA RH1T4821SPBNJA 4

Unit Dimensions ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE HIGH VOLTAGE CONNECTION 7/8 [22.2 mm], 13/32 [27.8 mm], 131/32 [0 mm] DIA. KNOCKOUTS. SUPPLY AIR 10 /16 [262 mm] NOTE: 24 CLEARANCE REQUIRED IN FRONT OF UNIT FOR FILTER AND COIL MAINTENANCE. W Air Dimensional Data LOW VOLTAGE CONNECTION /8 [1.9 mm] AND 7/8 [22.2 mm] KNOCKOUT A Return Air Opening Dimensions Model Cabinet Size Return Air Opening Width (Inches) Return Air Opening Depth/Length (Inches) 17 1 7 /8 19 3 /4 21 19 3 /8 19 3 /4 24 22 7 /8 19 3 /4 H AUXILIARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) HORIZONTAL APPLICATION ONLY PRIMARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) AUXILIARY DRAIN CONNECTION 3/4 [19.1 mm] FEMALE PIPE THREAD (NPT) UPFLOW/DOWNFLOW APPLICATION ONLY LIQUID LINE CONNECTION COPPER (SWEAT) 19 1 /2 [49 mm] RETURN AIR OPENING 21 11 /16 [1 mm] VAPOR LINE CONNECTION COPPER (SWEAT) UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. HORIZONTAL ADAPTER KIT VAPOR LINE CONNECTION AUXILIARY HORIZONTAL DRAIN CONNECTION 1 /16 [11 mm] 4 1 /8 [10 mm] 3 1 /16 [76 mm] 1 3 /16 [48 mm] 11 /8 [29 mm] 1 1 /16 [27 mm] 1 3 /8 [3 mm] 2 13 /16 [71 mm] 1 /4 [133 mm] 3 /8 [136 mm] UPFLOW UNIT SHOWN: UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT OR LEFT AIR SUPPLY. ( ) Designates Unit with Double Coil Cabinet PRIMARY DRAIN CONNECTION LIQUID LINE CONNECTION VERTICAL DRAIN PAN AUXILIARY UPFLOW/DOWNFLOW DRAIN CONNECTION

Dimensional Data Unit Dimensions & Weights Refrigerant Connections [ ] Air Designates Flow Metric Conversions Unit Weight/Shipping Weight Model Sweat (In.) [mm] ID Unit Unit Supply CFM (Nom.) [L/s] (Lbs.) [kg] Size Width Height Duct ( ) Designates Unit with Double Coil Cabinet RH1T W In. [mm] H In. [mm] A In. [mm] Unit With Unit Dimensions Liquid & WeightsVapor Lo Hi Coil (Max. KW) 2417SP 3/8 [9.3] 3/4 [19.0] 17 1 /2 [44] 42 1 /2 [1080] 16 1 /2 [406] 600 [283] 800 [378] 92/106 [42/48] 3617SP 3/8 [9.3] 3/4 [19.0] 17 1 /2 [44] 42 1 /2 [1080] 16 1 /2 [406] 1000 [472] 1200 [66] 96/110 [44/0] 4821SP 3/8 [9.3] 7/8 [22.23] 21 1 /2 [33] 0 1 /2 [1282] 19 1 /2 [49] 1400 [661] 1600 [7] 128/144 [6/6] *Maximum dehumidification airflow. 6

Airflow Directional Data Airflow Directional Data UPFLOW DOWNFLOW HORIZONTAL LEFT HAND AIRFLOW HORIZONTAL RIGHT HAND AIRFLOW 7

Airflow Performance Data Airflow Performance Airflow performance data is based on cooling performance with a coil and no filter in place. Select performance table for appropriate unit size, voltage and number of electric heaters to be used. Make sure external static applied to unit allows operation within the minimum and maximum limits shown in table below for both cooling and electric heat operation. For optimum blower performance, operate the unit in the.3 [8 mm] to.7 inches [18 mm] W.C. external static range. Units with coils should be applied with a minimum of.1 inch [3 mm] W.C. external static range. Airflow Operating Limits Model Cabinet Width 17 17/21 Cooling BTUH x 1,000 Cooling Tons Nominal Heat Pump or Air Conditioning Maximum Heat/Cool CFM [L/s] (37. CFM [18 L/s]/1,000 BTUH) (40 CFM [212 L/s]/Ton Nominal) Heat Pump or Air Conditioning Nominal Heat/Cool CFM [L/s] (33.3 CFM [16 L/s]/1,000 BTUH) (400 CFM [189 L/s]/Ton Nominal) Heat Pump or Air Conditioning Minimum Heat/Cool CFM [L/s] (30.0 CFM [14 L/s]/1,200 BTUH) (360 CFM [170 L/s]/Ton Nominal) Maximum kw Electric Heating & Minimum Electric Heat CFM [L/s] -24 2 900 [42] 800 [378] 720 [340] 13 617 [291] -36 3 130 [637] 1200 [66] 1080 [10] 18 104 [497] 21-48 4 1800 [80] 1600 [7] 1440 [680] 2 102 [709] Maximum Electric Heat Rise F [ C] 63 [17.2] 1 [10.6] 0 [10] 8

Airflow Performance Data 11V/208V/240V Airflow Performance Data RH1T (Piston) Model No. RH1T 2417SP No Heat 2417SP with 13 kw Heater 2417SP No Heat 2417SP with 13 kw Heater 3617SP No Heater 3617SP with 18 kw Heater 3617SP No Heater 3617SP with 18 kw Heater Tonnage Application 1. Ton 1. Ton 2 Ton 2 Ton 2. Ton 2. Ton 3 Ton 3 Ton Motor Speed From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 683/48 [322/229 L/s] 683/48 [322/229 L/s] 88/697 [40/329 L/s] 683/48 [322/229 L/s] 93/1084 CFM [441/12 L/s] 910/109 CFM [429/00 L/s] 1130/127 CFM [33/602 L/s] 110/120 CFM [21/90 L/s] Blower Size/ Motor Motor HP [W] Speed c External Static Pressure Inches W.C. [kpa] # of Speed 0.1 [.02] 0.2 [.0] 0.3 [.07] 0.4 [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 837 [39] 713 [366] 608 [287] 4 [261] 48 [229] 2 RPM 6 87 630 692 71 10x8 Watts 9 81 88 74 66 1/3 HP [249] Speed CFM 683 [322] 61 [290] 72 [270] 3 RPM 789 842 892 Watts 140 19 1 CFM 814 [384] 692 [326] 89 [278] 3 [22] 467 [220] 2 RPM 92 613 66 719 778 10x8 Watts 108 90 97 82 73 1/3 HP [249] Speed CFM 808 [381] 629 [297] 84 [276] 3 RPM 789 842 892 Watts 148 168 163 CFM 902 [426] 846 [399] 788 [372] 742 [30] 679 [320] 4 RPM 96 64 694 741 791 10x8 Watts 10 108 116 121 130 1/3 HP [249] Speed CFM 88 [276] 816 [38] 770 [363] RPM 834 879 92 Watts 18 182 214 CFM 882 [416] 827 [390] 769 [363] 723 [341] 661 [312] 4 RPM 9 670 719 767 817 10x8 Watts 113 12 124 129 197 1/3 HP [249] Speed CFM 833 [393] 791 [373] 746 [32] RPM 82 898 944 Watts 192 189 222 CFM 1093 [16] 100 [496] 1017 [480] 977 [461] 93 [441] 2 RPM 671 72 764 809 82 10x8 Watts 13 168 174 180 188 1/2 HP [373] Speed CFM 1084 [12] 1040 [491] 1001 [472] 3 RPM 896 936 971 Watts 249 27 261 CFM 1068 [04] 102 [484] 992 [468] 92 [449] 910 [429] 2 RPM 711 76 804 849 892 10x8 Watts 164 179 18 191 199 1/2 HP [373] Speed CFM 109 [00] 101 [479] 976 [461] 3 RPM 936 976 1011 Watts 260 268 272 CFM 1270 [99] 1237 [84] 1199 [66] 116 [0] 1130 [33] 4 RPM 77 816 846 882 926 10x8 Watts 237 249 29 268 277 1/2 HP [373] Speed CFM 127 [602] 1244 [87] 1211 [71] RPM 963 999 1029 Watts 338 348 363 CFM 124 [88] 1212 [72] 1174 [4] 1140 [38] 110 [21] 4 RPM 81 86 886 922 966 10x8 Watts 248 260 270 279 288 1/2 HP [373] Speed CFM 120 [90] 1219 [7] 1186 [60] RPM 1003 1039 1069 Watts 349 39 374 9

Airflow Performance Data 11V/208V/240V Airflow Performance Data RH1T (Piston) (con t.) Model No. RH1T 4821SP No Heater 4821SP with 20 kw Heater 4821SP No Heater 4821SP with 2 kw Heater Tonnage Application 3. Ton 3. Ton 4 Ton 4 Ton Motor Speed From Factory Manufacturer Recommended Air-Flow Range (Min/Max) CFM 1337/1447 CFM [631/683 L/s] 1297/1333 CFM [612/629 L/s] 13/164 CFM [724/781 L/s] 149/1614 CFM [706/762 L/s] Blower Size/ Motor HP [W] # of Speed 10x10 3/4 HP [9] Speed 10x10 3/4 HP [9] Speed 10x10 3/4 HP [9] Speed 10x10 3/4 HP [9] Speed Motor Speed 2 3 2 3 4 4 CFM [L/s] Air Delivery/RPM/Watts (No Filter) External Static Pressure Inches W.C. [kpa] 0.1 [.02] 0.2 [.0] 0.3 [.07] 0.4 [.10] 0. [.12] 0.6 [.1] 0.7 [.17] CFM 1473 [69] 1442 [681] 1401 [661] 1373 [648] 1337 [631] RPM 781 82 867 90 949 Watts 27 271 303 307 31 CFM 1447 [683] 1433 [676] 1402 [662] RPM 987 1034 106 Watts 394 406 40 CFM 1433 [676] 1402 [662] 1361 [642] 1333 [629] 1297 [612] RPM 831 87 919 94 989 Watts 277 29 313 319 32 CFM 1333 [629] 1300 [613] 1267 [98] RPM 1011 1046 1080 Watts 30 364 377 CFM 166 [786] 1631 [770] 1601 [76] 172 [742] 13 [724] RPM 83 893 934 968 101 Watts 31 387 401 406 422 CFM 164 [781] 1624 [766] 163 [738] RPM 1036 1078 109 Watts 00 13 23 CFM 162 [767] 191 [71] 161 [737] 132 [723] 149 [706] RPM 894 932 970 1020 102 Watts 389 400 410 430 40 CFM 1614 [762] 184 [748] 123 [719] RPM 108 1090 110 Watts 14 20 30 Notes: All 208/240V PSC motors have voltage taps for 208 and 240 volts. All 208/240V PSC motors are shipped on high speed and 240 volts. If the application external static is less than 0." WC, adjust the motor speed to the low static speed as described below: Unplug the black motor wire off the relay on the control board and plug in the red motor wire. Replace the cap on the black motor wire. Voltage change (208/240V motors): Move the orange lead to transformer 208V tap from 240V tap. Replace the wire cap on 240V tap. Unplug the purple motor wire off the transformer and plug in the yellow motor wire. Replace the cap on the purple motor wire. The above airflow table lists the airflow information for air handlers without heater and air handler with maximum heater allowed for each model. The following formula can be used to calculate the approximate airflow, if a smaller (N kw) than the maximum heater kit is installed. Approximate Airflow = Airflow without heater - (Airflow without heater - Airflow with maximum heater) x (N kw/maximum heater kw) 10

Electrical Data Electrical Data Blower Motor Only No Electric Heat RH1T (Piston) Model RH1T Voltage Application Phase* Hertz HP [W] RPM Speeds Amps. Minimum Ampacity Maximum Protector 2417SP 1/3 [249] 300-1100 4 1.6 2 1 3617SP 208/240 1 & 3 60 1/2 [373] 300-1100 4 2.7 4 1 4821SP 3/4 [9] 300-1100 4 3.8 1 2417SP 1/3 [249] 300-1100 4 4.8 6 1 3617SP 11 1 60 1/2 [373] 300-1100 4 6.8 9 1 4821SP 3/4 [9] 300-1100 4 8.4 11 1 * Blower motors are all single phase motors. R X B H 17 A 03 J Electrical Designation J = 208-230V/1/60 C = 208-230V/3/60 D = 480V/3/60 Heating Rating 03= 3KW 1 = 1KW 0= KW 18 = 18KW 07= 7KW 20 = 20KW 10= 10KW 2 = 2KW 13= 13KW 30 = 30KW Design Series A = With Breaker B = Without Breaker C = Disconnect Cabinet Size 17= 17." 24= 21"/24." 1724 = 17."/21"/24." Heater Blower Accessory Trade Name Rheem 11

Electrical Data Electrical Data With Electric Heat RH1T (Piston) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RH1T 2417SPAN Heater Model No. Heater kw (208/240V) (480V) PH/HZ No. Elements kw Per Type Supply Single Multiple Amps. Motor Ampacity Minimum Ampacity Maximum Protector RXBH-17?03J 2.2/3 1/60 1-3 SINGLE 10.8/12. 2.8 18/20 20/20 RXBH-1724?0J 3.6/4.8 1/60 1-4.8 SINGLE 17.3/20 2.8 26/29 30/30 RXBH-1724?07J.4/7.2 1/60 2-3.6 SINGLE 26/30 1.6 3/40 3/40 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40 2.8 47/4 0/60 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20/23.1 2.8 29/33 30/3 RXBH-1724A13J 9.4/12. 1/60 3-4.17 SINGLE 4.1/2.1 2.8 60/69 60/70 RXBH-1724A13J 3.1/4.2 1/60 1-4.17 MULTIPLE CKT 1 1/17.4 2.8 23/26 2/30 RXBH-1724A13J 6.3/8.3 1/60 2-4.17 MULTIPLE CKT 2 30.1/34.7 0 38/44 40/4 RXBH-17?03J 2.2/3 1/60 1-3 SINGLE 10.8/12. 4.1 19/21 20/2 RXBH-1724?0J 3.6/4.8 1/60 1-4.8 SINGLE 17.3/20 4.1 27/31 30/3 RXBH-1724?07J.4/7.2 1/60 2-3.6 SINGLE 26/30 4.1 38/43 40/4 RXBH-1724?10J 7.2/9.6 1/60 2-4.8 SINGLE 34.6/40 4.1 49/6 0/60 RXBH-1724A10C 7.2/9.6 3/60 3-3.2 SINGLE 20/23.1 4.1 31/3 3/3 RXBH-1724A13J 9.4/12. 1/60 3-4.17 SINGLE 4.1/2.1 4.1 62/71 70/80 RXBH-1724A13J 3.1/4.2 1/60 1-4.17 MULTIPLE CKT 1 1/17.4 4.1 24/27 2/30 3617SPAN RXBH-1724A13J 6.3/8.3 1/60 2-4.17 MULTIPLE CKT 2 30.1/34.7 0 38/44 40/4 RXBH-1724A1C 10.8/14.4 3/60 3-4.8 SINGLE 30/34.6 4.1 43/49 4/0 RXBH-1724A1J 10.8/14.4 1/60 3-4.8 SINGLE 1.9/60 4.1 70/81 70/90 RXBH-1724A1J 3.6/4.8 1/60 1-4.8 MULTIPLE CKT 1 17.3/20 4.1 27/31 30/3 RXBH-1724A1J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40 0 44/0 4/0 RXBH-1724A18J 12.8/17 1/60 3 -.67 SINGLE 61.6/70.8 4.1 83/94 90/100 RXBH-1724A18J 4.3/.7 1/60 1 -.67 MULTIPLE CKT 1 20./23.6 4.1 31/3 3/3 RXBH-1724A18J 8./11.3 1/60 2 -.67 MULTIPLE CKT 2 41.1/47.2 0 2/60 60/60 Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger standard fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. 12

Electrical Data Electrical Data With Electric Heat RH1T (Piston) (Cont.) Installation of the U.L. Listed original equipment manufacturer provided heater kits listed in the following table is recommended for all auxiliary heating requirements. Air Handler Model RH1T 4821SP Heater Model No. Heater kw (208/240V) (480V) PH/HZ No. Elements kw Per Type Supply Single Multiple Amps. Motor Ampacity Minimum Ampacity Maximum Protector RXBH-1724A18J 12.8/17 1/60 3 -.67 SINGLE 61.6/70.8 4.1 83/94 90/100 RXBH-1724A18J 4.3/.7 1/60 1 -.67 MULTIPLE CKT 1 20./23.6 4.1 31/3 3/3 RXBH-1724A18J 8./11.3 1/60 2 -.67 MULTIPLE CKT 2 41.1/47.2 0 2/60 60/60 RXBH-24A20C 14.4/19.2 3/60 6-3.2 SINGLE 40/46.2 4.1 6/63 60/70 RXBH-24A20C 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 1 20/23.1 4.1 31/3 3/3 RXBH-24A20C 7.2/9.6 3/60 3-3.2 MULTIPLE CKT 2 20/23.1 0 2/29 2/30 RXBH-24A20J 14.4/19.2 1/60 4-4.8 SINGLE 69.2/80 4.1 92/106 100/110 RXBH-24A20J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 1 34.6/40 4.1 49/6 0/60 RXBH-24A20J 7.2/9.6 1/60 2-4.8 MULTIPLE CKT 2 34.6/40 0 44/0 4/0 RXBH-24A2C 18/24 3/60 6-4 SINGLE 0/7.8 4.1 68/78 70/80 RXBH-24A2C 9/12 3/60 3-4 MULTIPLE CKT 1 2/28.9 4.1 37/42 40/4 RXBH-24A2C 9/12 3/60 3-4 MULTIPLE CKT 2 2/28.9 0 32/37 3/40 RXBH-24A2J 18/24 1/60 6-4 SINGLE 86.4/99.9 4.1 114/130 12/10 RXBH-24A2J 6/8 1/60 2-4 MULTIPLE CKT 1 28.8/33.3 4.1 42/47 4/0 RXBH-24A2J 6/8 1/60 2-4 MULTIPLE CKT 2 28.8/33.3 0 37/42 40/4 RXBH-24A2J 6/8 1/60 2-4 MULTIPLE CKT 3 28.8/33.3 0 37/42 40/4 Supply circuit protective devices may be fuses or HACR type circuit breakers. Largest motor load is included in single circuit and multiple circuit 1. If non-standard fuse size is specified, use next size larger standard fuse size. J Voltage (230V) single phase air handler is designed to be used with single or three phase 230 volt electric heaters. In the case of connecting 3-phase power to the air handler terminal block without the heater, bring only two leads to the terminal block cap, insulate and fully secure the third lead. 13

Electrical Wiring Electrical Wiring Power Wiring Field wiring must comply with the National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. Supply wiring must be 7 C minimum copper conductors only. See electrical data for product Ampacity rating and Protector requirement. Accessories Combustible Floor Base RXHB- Model Cabinet Size 17 21 24 Combustible Floor Base Model Number RXHB-17 RXHB-21 RXHB-24 Jumper Bar Kit 3 Ckt. to 1 Ckt. RXBJ-A31 is used to convert single phase multiple three circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Jumper Bar Kit 2 Ckt. to 1 Ckt. RXBJ-A21 is used to convert single phase multiple two circuit units to a single supply circuit. Kit includes cover and screw for line side terminals. Note: No jumper bar kit is available to convert three phase multiple two circuit units to a single supply circuit. Grounding This product must be sufficiently grounded in accordance with National Electrical Code (C.E.C. in Canada) and any applicable local ordinance. A grounding lug is provided. Auxiliary Electric Heater Kits RXBH- Heater Kits include circuit breakers which meet UL and cul requirements for service disconnect. See the Electric Heat Electrical Data in this specification sheet for specific Heater Kit Model numbers. External Filter Base RXHF- Model Cabinet Size Filter Size In. [mm] Part Number* A 17 16 x 20 [406 x 08] RXHF-17 1.70 21 20 x 20 [08 x 08] RXHF-21 19.20 24 2 x 20 [63 x 08] RXHF-24 22.70 *Accommodates 1" or 2" filter B 17. 21.0 2. Auxiliary Horizontal Overflow Pan Accessory RXBM- Nominal Cooling Capacity-Tons Auxiliary Horizontal Overflow Pan Accessory Model Number 1 1 /2-3 RXBM-AC48 3 1 /2 - RXBM-AC61 14

Limited Warranty GENERAL TERMS OF LIMITED WARRANTY* Rheem will furnish a replacement for any part of this product which fails in normal use and service within the applicable periods stated, in accordance with the terms of the limited warranty. Conditional Parts (Registration Required)...Ten (10) Years *For complete details of the Limited and Conditional Warranties, including applicable terms and conditions, contact your local contractor or the Manufacturer for a copy of the product warranty certificate. 1

The new degree of comfort. In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Heating, Cooling & Water Heating P.O. Box 17010 Fort Smith, Arkansas 72917 www.rheem.com Rheem Canada Ltd./Ltée 12 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P PRINTED IN U.S.A. 10/16 QG FORM NO. H11-9 REV. 1