Connection Accessories for small Burner Controls

Similar documents
Actuators for air dampers and control valves of oil burners

Electronic Ignition Module

Actuators. Building Technologies Division

ASZ... Potentiometers. Building Technologies Division. ASZxx.3x

Actuators for Air and Gas Dampers

Actuators for air dampers and control valves of oil burners

SQN9... Damper Actuators. Building Technologies HVAC Products. SQN9..., front (covers removed) SQN9..., rear (covers fitted)

Actuators for air dampers and control valves of oil burners

Electronic Ignition Equipment

Actuators for Air and Gas Dampers

Actuators for air and gas dampers

Actuators for Air and Gas Dampers

For air / gas dampers and control valves of oil or gas burners

For air dampers and control valves of oil or gas burners

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

VLF45... Hot Air Valves. Building Technologies Division

Boiler Management Unit (BMU)

Gas Pressure Governors

Condensation monitor

Proportional controlling element

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Explosion protected terminal boxes type, GHG 72.

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

VGD20... VGD40... Double Gas Valves. Siemens Building Technologies Landis & Staefa Division

Actuators for Fire Protection Dampers

Actuators for Fire and Smoke Protection Dampers

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Actuators for Fire and Smoke Protection Dampers

Actuators for Fire and Smoke Protection Dampers

SAX Electronic Valve Actuator

Electromotoric Actuators

Powerline QC. Single Power Connectors. Ten 47 Limited

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

Operating Instructions (Translation)

Installation Instructions Spector compact Conductivity Transmitter System LRGT 16-1

Installation manual wall-mounted distributor

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

SKPx5... Actuators for Gas Valves. Building Technologies HVAC Products SKP15... SKP25... / SKL25 SKP55... SKP75...

Differential Pressure Switch QBM81-

K25000 & KD25000 Series

Electronic Circuit Breaker ESS20-0..

HS1E Series Full Size Solenoid Locking Switches

Eclipse Trilogy Actuator

Electromotoric Actuators

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Differential pressure sensor

SAV Electronic Valve Actuator

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Installation manual portable distributors

Underfloor to desk 231

Door Interlock Switches

Electronic Circuit Breaker ESS20

OMNIA System OMNIA SYSTEM - IP55 FLUSH AND SURFACE MOUNTING MODULAR SYSTEM. t. 50

Operating Instructions

IP65 SEALED DUAL-COMPARTMENT ENCLOSURE

Design Guide for Integration of Fixed-Mount Circuit Breakers

HS1E Series Full Size Interlock Switch with Locking Solenoid

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

ADDENDUM to INSTALLATION INSTRUCTIONS for Grant Solar Pump Station

Plexo 3 weatherproof cabinets

Electromotoric Actuators

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Operating Instructions

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Operating Instructions Flexdip CYA112

workshop specifications Plexo³ IP 65 cabinets

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

The Powermatic User Guide Test Sieve Shaker

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Electromotoric Actuators

Electromotoric actuators

Schaltgeräte GmbH GmbH Geschäftsbereich Leuchten

Model DS1000/DT20 System

UZK12.071, UZO GENERAL DESCRIPTION 2. DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Product Data For FARNELL

Electromotoric Actuators

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

General notes. Operating conditions

UZK12.071, UZO DATA 1. GENERAL DESCRIPTION 4. MARKINGS 3. ORDER NUMBERS PASSIVE BATTERY MODULE BATTERY MODULE 12V, 7AH 1/9.

Operating Instructions

Operating Instructions

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Operating instructions Binary level sensor LMT /00 06/2011

Design Standard. Purpose: Design Standard:

SERVICE MANUAL ULTIMATE 200

SatchwellTM ALMS, ALXS, ALES SPRING RETURN LINEAR ACTUATORS. Satchwell FEATURES

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Installation instructions for the TriVision Car Docking Station

PSS 5000 Standard & Compact (For systems with CPB50x)

Operating Instructions

Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Powerline. Single Power Connectors. Ten 47 Limited

0CV2. 0CV2 series dust explosion-proof three-phase. asynchronous motor INSTRUCTIONS. Siemens Standard Motors Ltd

Electrical Actuator HH-500 REsearch COntrol

Transcription:

7 201 AGK11... plug-in base with AGK65... cable gland holder AGK11... plug-in base with AGK66 cable gland holder Connection Accessories for small Burner Controls AGK11... AGK65... AGK66 Accessories for connecting small-capacity burner controls to combustion plant. The AGK11..., AGK65..., AGK66 and this Data Sheet are intended for use by OEMs which integrate the accessory items in their products. Use The AGK... are for use in connection with the following types of burner controls: LGA... LGB... LGD1... LOA... LME... LMO... The AGK11... plug-in base is suited for use with the AGK65... cable gland holders or the AGK66.

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes must be observed! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area, completely isolate the plant from mains supply (all-polar disconnection). Ensure that the plant cannot be inadvertently switched on again and that it is indeed dead. If not observed, there is a risk of electric shock hazard Ensure protection against electric shock hazard by providing adequate protection when mounting the burner control. If not observed, there will be a risk of electric shock. Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state and make the safety checks. If not observed, the safety functions are no longer ensured and there will be a risk of electric shock Mounting notes Ensure that the relevant national safety regulations are complied with We recommend to connect the burner controls with a single-section terminal block (no risk of mixing up when reconnecting) Connect the earthing lug on the AGK11... plug-in base to the burner using a metric screw with a lockwasher or similar The cable and cable gland holders clip onto the AGK11... plug-in base Installation notes Do not mix up live and neutral conductors Decisive for the electrical connections of valves and other burner plant components are the plant diagram and the Mounting and Commissioning Instructions provided by the burner supplier To isolate the plant from the mains supply, use an all-polar switch with a contact gap of least 3 mm To protect the burner control electrically, install a primary fuse To prevent wrong combinations of bases and burner controls, the AGK11.6 plug-in base may only be used in connection with burner controls featuring postpurging (e.g. LME39..., LMO39..., LMO64...) Standards and certificates Note! Only in connection with burner controls! EAC Conformity mark (Eurasian Conformity mark) ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007 Disposal notes Both plug-in base and cable gland holders must not be disposed of together with household waste. Local and currently valid legislation must be observed. 2/5

Mechanical design AGK11 plug-in base AGK11.6 plug-in base AGK65 cable gland holder AGK65.1 cable gland holder AGK66 cable holder - Use for phasing controlled burner controls - Color Black - Accommodates (in addition to the 12 connection terminals): - 3 neutral terminals, pre-wired to terminal 2, the neutral input - 4 earth conductor terminals, joining in a lug for earthing the burner - 2 auxiliary terminals marked «31» and «32» - With 2 holes in the baseplate of the AGK11 for cable entry - Provided with catches on the 2 narrow sides which audibly engage when the burner control is plugged in - To disengage, a screwdriver must be slightly tilted in the guiding slots - Neutral and auxiliary terminals with self-tapping screws - Connection terminals with self-locking screws - Supplied with terminals open to facilitate mounting - The burner control is secured to the burner with fixing screws M5 - Use for burner controls with continuous phase - Color: Silver-grey RAL 9001 - Other specifications like AGK11 - With 5 threaded knockout holes for nonmetallic Pg11 cable glands - 3 on the front and 1 on each of the other sides - Removable - With 5 threaded knockout holes for nonmetallic M16 x 1.5 cable glands - 3 on the front and 1 on each of the other sides - Removable - With 6 knockout holes for cable entry, without cable strain relief - 1 x 8.8 mm dia. and 1 x 17 mm dia. laterally, 3 x 7 mm dia. on the front, and 1 rectangular opening 6 x 20 mm on the front - Can be used in place of the cable gland holder (refer to «Ordering») Ordering Plug-in base - for phasing controlled burner controls - With 2 holes in baseplate - Black Plug-in base - for burner controls with continuous phase - With 2 holes in baseplate - Silver-gray RAL 9001 Cable gland holder - Pg11 Cable gland holder - M16 x 1.5 Cable holder with knockout holes AGK11 AGK11.6 AGK65 AGK65.1 AGK66 3/5

Technical data General data Weight - AGK11... plug-in base - AGK66 cable holder - AGK65... cable gland holder Approx. 80 g Approx. 12 g Approx. 12 g Tightening torque To DIN EN 60335-1 - Cable with ferrules 50 Ncm Loosening torque 40 Ncm Cross sectional areas that can be connected to AGK11... - Terminals 1...12 Min. 0.5 mm² Max. 1.5 mm² Solid or stranded wire with ferrule - Auxiliary terminals N, PE, 31 and 32 Min. 0.5 mm² Max. 1.5 mm² Solid or stranded wire with ferrule (if 2 wires are connected to the same terminal, they must have the same cross-sectional area) Environmental conditions Storage DIN EN 60721-3-1 Class 1K3 Class 1M2 Temperature range -20...+60 C <95 % r.f. Transport DIN EN 60721-3-2 Class 2K2 Class 2M2 Temperature range -40...+60 C <95 % r.h. Operation DIN EN 60721-3-3 Class 3K5 Class 3M2 Temperature range -20...+60 C <95 % r.h. Warning! Condensation, formation of ice and ingress of water are not permitted! If not observed, the safety functions are no longer ensured and there will be a risk of electric shock. 4/5

33,25 Dimensions Dimensions in mm AGK11 plug-in base 1 2 3 4 5 6 7 8 9 10 11 12 7201m01/0100 AGK11... plug-in base with screw terminals «A»: Holes for fixing screws «B»: Holes for cable entry 5,4 N 31 32 4 17 23,5 62,5 «C»: Earthing lug «31» and «32»: Auxiliary terminals 16,2 «N»: Neutral terminals, connected to neutral input 4,5 10,5 24 24 30 30 A B C (terminal 2) Underneath: 4 earth conductor terminals, joining in a lug for earth- ing the burner Hatched: Position of AGK65... cable gland holder and AGK66 cable holder Attention! Connection of earthing lug «C» and fixing screw in «A» to the burner s ground (using a metric screw with a lockwasher or similar!) If this is not observed, there is a risk of electric shock. AGK65 cable gland holder AGK65.1 cable gland holder Pg11 M16 x 1,5 Ring O 10 mm Pg11 M16 x 1,5 19,5 43,9 60,5 7201m03/0100 19,5 43,9 60,5 7201m12/0102 33,25 AGK66 cable holder R3 R8,5 R4,6 21 32 43 50,5 70,3 7201m02/0799 33,25 2016 Siemens AG, Berliner Ring 23, D-76437 Rastatt Subject to change! 5/5