SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Similar documents
Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

l Snap-Action Switches

S870, S970 Series. Snap-action switches. Positive opening operation Self-cleaning contacts Catalogue D70.en

Contactors. Brochure. Contactors for industry, rolling stock and battery-powered vehicles Emergency disconnect switches

COMPONENTS. Off-load Switch for Fixed Installation Title type SW

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

l Snap-Action Switches

S880 Series Snap-action switches with positive opening operation and self-cleaning contacts Catalogue D80.en

TECHNICAL DESCRIPTION

Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

BETA Switching Switches and Light Indicators

Varius SUMMARY OF MODELS

TECHNICAL DESCRIPTION

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Varius SUMMARY OF MODELS

Phase + Neutral, neutral on right side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Disconnectors and earthing switches up to 25 kv AC

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

NXPLUS C Single busbar. Maintenance-free for lifetime

vertical fuse switch disconnectors

TX³ RCCBs 2P up to 100 A

Fuse switch-disconnectors

Connect - Contact - Control. Brochure. l Connectors

Phase + Neutral, neutral on left side

K50H004UP cam changeover switch - 4-pole A - screw mounting

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Thermal Overcurrent Circuit Breaker 3120-F...

FA Off-Load Switches. Up to 8000 A and 3000 V AC/DC Expertly engineered for reliable performance

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

DX³ RCCBs - ID 4P up to 100 A

3 RD RAIL SWITCH FHT-KS 4000 DISCONNECTOR

T-Switches Range. TL Contactors TS disconnectors TP Contactors. TELARC s multipurpose DC and AC current switches for multiple application.

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Connect - Contact - Control. Connectors. High Power Connectors for industrial trucks Catalogue A84.en

Gas Insulated Metal-clad Switchgear, HMGS!

Manual Motor Starters. Meta-MEC

Fuse switch-disconnectors

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Installation Contactors RIC, RAC

Thermal Overcurrent Circuit Breaker 3120-F...

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Special Purpose Fuses

Thermal-Magnetic Circuit Breaker M1-...

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal Overcurrent Circuit Breaker 3120-F...

AF40... AF96 3-pole contactors Technical data

Thermal Overcurrent Circuit Breaker 3120-F...

TAE pole Contactors

Thermal overload relay TF65 and TF96

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Industrial Contactors CTX 3 3P 185A - 800A

Fuse switch disconnectors

Thermal Overcurrent Circuit Breaker 3120-F...

Magnetic Overcurrent Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

CPG.0 Single busbar gas-insulated cubicles

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Brochure Connectors. More information here: schaltbau-gmbh.com

DPX Magnetic only

3NP1 Fuse Switch Disconnectors up to 630 A

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Products and solutions for photovoltaic applications

Connectors. M Series Circular Modular Connectors Catalogue A10.en

AF series contactors (9 2650)

25A 25A 32A 40A 40A 63A 63A 80A

Electronic Circuit Breaker ESS20-0..

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Varius SUMMARY OF MODELS

RX 3 M.C.B A up to 63 A

B kv T&D GAS INSULATED SWITCHGEAR

DMX 3 -I 2500 switch disconnectors

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Connectors. LV Series High Power Connectors for faster charging of industrial trucks Catalogue A84.en. more information here: schaltbau-gmbh.

Thermal-Magnetic Circuit Breaker 201/-WA

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Power Electronics. Motor brake relay GA 9031 ministop

Solenoid Valve Island Type 3965

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Thermal overload relay TF140DU and TF140DU-V1000

Transcription:

4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en

2 SD, SE, SDE, SCO Multipole switchgear for voltages up 600 kv to 3 kv Switchgear for rolling stock The switches of series SD, SE, SDE and SCO have a modular design and can be used for the function disconnect, earthing, disconnect and earthing as well as switching between two circuits (change-over). Switching between the individual switch positions is permissible without load only. The number of circuits can be individually adapted to the respective requirements. A combination of the above-mentioned functionalities within one device is simple to implement. The modularity is given not only to the number and functions of the switching chambers, but also to the possibilities of actuation by drive units. Applications Traction Supply 25 kv 50 Hz / 5 kv 6 2 /3 Hz Traction 2 Line contactor Train line Main transformer AUX AUX M M M M 2 4 5 3 3 Use of functions disconnect, earthing, and change over-switching in railway applications for all rolling stock for voltage range up to 3 kv max: Traction inverter Auxiliary inverter Train power supply lines DC link: interconnection of traction converters in the event of a fault 2 Transformer switch: switch for changing over from 25 kv 50 Hz auf 5 kv 6 2 /3 Hz on main transformer 3 Disconnector and change over switch: changes output of a traction inverter to the auxiliary loads (if auxiliary inverter is broken) 4 Disconnecting and earthing of high voltage busbar(s) 5 Earthing of circuits inside inverters Further configurations: disconnecting and earthing of various circuits inside inverters according to customer requirements! Standards EN 5055: Railway applications Electronic equipment used on rolling stock EN 502-3-2: Railway applications Electromagnetic compatibility Part 3-2: Rolling stock Apparatus EN 5024-: Railway applications Insulation coordination Part : Basic requirements Clearances and creepage distances for all electrical and electronic equipment EN 6373: Railway applications Rolling stock equipment Shock and vibration tests EN 60077-: Railway applications Electric equipment for rolling stock Part : General service conditions and general rules EN 60077-2: Railway applications Electric equipment for rolling stock Part 2: Electrotechnical components General rules EN 45545: Railway applications Fire protection on railway vehicles. NF 60/NF 602: Fire test to railway components

3 Features Four different types of drive units are available:. Manually operated by lever, mechanical interface on customer request 2. Electrically operated by motor-gear-unit, end positions controlled by digital encoder 3. Electrically operated by linearmotor 4. Pneumatically operated drive (upon request) Individual assembly of switching chambers / main contacts: NO Normally open contact NC Normally closed contact CO Change-over-switch Modular, compact and rugged design Switching to different switching positions allowed without load only Nominal voltage 600 V DC up to 3 kv DC Conventional thermal current 500 A per switching chamber, parallel switching of switching chambers is possible for higher rated currents Configurable up to 0 switching chambers 2, 3 or 4 switching positions can be implemented, for variant linear motor maximal 3 positions Key locking systems by means of a key switches, square keys and/or padlocks are possible Auxiliary switches for all positions are provided Detection and indication of high voltage by means of HV sensor, optional Optional integrated high voltage sensors detects and indicates if high voltage circuit is under load by flashing of 3 red LEDs. It indicates AC and DC voltages from 40 V to 4.2 kv Mechanical interfaces such as front panel, housing and so on can be adapted to installation conditions of the E-containers, racks, etc. Easy and low cost maintenance: Easy inspection and low life cycles cost (LCC) Preventive maintenance a proper greasing is required only. This activity can be performed directly on train, special inspection points on the switching chamber are available Corrective maintenance a service kit consisting 4 different spare parts is sufficient to repair switching chamber and/or active (movable) components Ordering code Example: SD 03 MA 00 0 0 Series SD SE SDE SCO Nominal voltage 03 U n = 3 kv DC Drive unit / activation unit MA MG ML MP Disconnecting switch Earthing switch Disconnector and earthing switch, combined Change-over switch Manual Motor-driven: motor gear unit Motor-driven: linear motor Pneumatic drive (upon request) Switching capability, Making 00 Making: Without load Control voltage 24 / 36 / 72 / 0 V DC Running number of variants; list of special design which are not fixed in ordering code above, like: Design of front panel, different keylock systems, number and configuration of the switching chambers, different installation variants on-roof / in-roof,... Special design Special design 2 Special design 3 Special design 4 Special design... Special design 0 02 03 04... The multipole switchgear on this catalogue are individual configurable for your application, but based on standard components. Do you need support for a special application? Please contact us! We would be glad to assist you in the selection of the contactor that suits your application best.

4 Specifications Series Switch for SD Disconnecting SE Earthing SDE Disconnecting and earthing SCO Change-over Switching chamber Type of voltage DC, AC (f < 60 Hz) DC, AC (f < 60 Hz) DC, AC (f < 60 Hz) DC, AC (f < 60 Hz) Number of fixed contacts, configuration... 0, NC / NO / CO... 20, NC / NO / CO... 20, NC / NO / CO... 20, NC / NO / CO Nominal voltage U n 3,000 V 3,000 V 3,000 V 3,000 V Rated operating voltage U e 3,600 V 3,600 V 3,600 V 3,600 V Rated insulation voltage U Nm 4,800 V 4,800 V 4,800 V 4,800 V Rated impulse withstand voltage U Ni 25 kv 25 kv 25 kv 25 kv Pollution degree PD3 PD3 PD3 PD3 Overvoltage category OV3 OV3 OV3 OV3 Conventional thermal current I th 500 A * --- 500 A * 500 A * Component category / class (IEC 60077-2) A4 / C2 A4 / C2 A4 / C2 A4 / C2 Making capacity, breaking capacity without load without load without load without load Rated short-time withstand current I cw T < 00 ms / T < 25 ms 4 ka / 50 ka 4 ka / 50 ka 4 ka / 50 ka 4 ka / 50 ka Critical current range none none none none Design Contact blades, shape / / / / / / / / Contact blades, material Fixed contacts, material Terminals Torque Bolt, M8 20 Nm max. or stainless steel Bolt, M8 20 Nm max. Bolt, M8 20 Nm max. Bolt, M8 20 Nm max. Auxiliary contacts Number / type per position / S826 (Schaltbau snap-action switches, see catalogue D26) or * 2 Contact material Silver S826 switching capacity (T = 5 ms) 6 A @ 24 V DC; 3.5 A @ 80 V DC; 7 A @ 0 V DC Terminals Terminal block, connector or * 2 Drive unit Motor voltage U SM 24 / 36 / 72 / 0 V DC Control voltage encoder U SE 24 V DC Tolerance motor and control voltage -30 %... +25 % U s Switching positions Manual: lever or * 2 Motor gear unit with digital encoder Linear motor unit with digital encoder Change over time Motor gear unit with digital encoder Linear motor unit with digital encoder 4 max. sequence -2-3-4-3-2-4 max. sequence -2-3-4--2-3-4-... 3 max. sequence -2-3-2- approx. 3 sec approx. 3 sec, 8 sec max. * 3 Terminals Terminal block, connector or * 2 Interlock * 2 Key lock switches / square key locks / key multiplier / pad locks / electromagnetic Mounting Mounting Position Degree of protection 4x Screw M0 or * 2 horizontal, vertical IP00 Mechanical endurance (IEC 60077-2, IEC 60077-2) 25,000 operating cycles Vibration / Shock (IEC 6373) Category, Class B Housing Switching chamber Frame Ambient conditions Operating temperature Storage temperature Altitude Humidity (EN 5025-) Weight Manual Motor gear unit Linear motor unit Fiberglass reinforced plastic Stainless steel or * 2 Manual: -50 C +40 C / Motor gear unit/linear motor unit: -40 C +70 C Manual: -50 C +70 C / Motor gear unit/linear motor unit: -40 C +85 C < 2,000 m above sea level < 75 % im yearly average approx. 25 kg * 4 approx. 35 kg * 4 approx. 30 kg * 4 * Per switching chamber *2 Customer specific / upon request *3 Depending on the number of switching chambers *4 Switchgear with 3 switching chambers, each additional plus approx. 3 kg

5 Switching chamber Disconnecting, change-over, earthing SD, Disconnecting, change-over Switching chamber with 2 positions and 4 blade contacts 2 Disconnecting, change-over Switching chamber with 4 positions and 3 blade contacts 2 3 Disconnecting, change-over Switching chamber with 4 positions and 2 blade contacts 2 3 4 4 Terminal M8, 2 switching positions Fixed contact... 4 switching positions Contact blade... 4 switching positions Disconnecting, earthing Switching chamber with 2 positions and 4 blade contacts for earthing of 3 circuits Disconnecting, change-over, earthing Switching chamber with 4 positions and 3 blade contacts for earthing of 2 circuits Disconnecting, change-over, earthing Switching chamber with 4 positions and 2 blade contacts for earthing of circuit 2 2 3 2 3 4 4 Terminal M8 2 earthed position Fixed contact 3 earthed position Contact blade 4 earthed position Switching chamber Earthing SE series Earthing Switching chamber with 4 blade contacts for earthing of 4 circuits Earthing Switching chamber with 3 blade contacts for earthing of 3 circuits Earthing Switching chamber with 2 blade contacts for earthing of 2 circuits 2 2 2 Terminal M8 2 earthed position Fixed contact 2 earthed position Contact blade 2 earthed position Shown are example configurations We are happy to realize your required switching configuration. Do not hesitate to contact us. Our aim is to implement your switching function by the optimum number of switching chambers. The requested switching configuration will be realized by the: Number of switching chambers Number of switching positions Number and type of blade contacts Type of actuation

6 SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram Switchgear with 2 HV switching chambers, manual actuation and HV indicators (LED) Handle 4x mounting for screws M8 ~265.5 2 85.5 4x aux. switches (gray code) HV-B swichting chamber ~3.5 25 25 77 High-voltage terminals M8 Earthing terminal M8 350 97 354 364 400 0 25 25 0 SERVICE GROUND 0 22 22 0 390 Service position 4x high-voltage indicators (LED) Ground position 4x high-voltage indicators (LED) 2x mounting for screws M6 SD/SE/SDE/SCO 03 MG xxx xx Dimension diagram Switchgear with 3 HV switching chambers and motor gear unit Motor 325.5 45 5.5 Gear Earthing terminal M6 87.5 270 320 High-voltage terminals M8 Digital encoder 9... 24 V DC 4x aux. switches (gray code) 4x mounting M0 352.5 32.5 22.5 55.2 HV-B swichting chamber HV-C swichting chamber Dimensions in mm /

7 SD/SE/SDE/SCO 03 ML xxx xx Dimension diagram Switchgear with 3 HV switching chambers and linear motor unit High-voltage terminals M8 340 320 83 53 8 HV-B swichting chamber HV-C swichting chamber 4x mounting for screws M0 4x aux. switches (gray code) Motor 30 254 292 20 20 300 SD/SE/SDE/SCO 03 MA xxx xx Dimension diagram Switchgear with HV switching chamber, manual actuation and 2 key switches Handle. 25 Nm max. 2x Key locks 80 56 2 20 260 4x mounting for screws M0 High-voltage terminals M8 80 Service position 45 340 80 2x aux. switches Ground position Earthing terminal M8 Earthing terminal M6 300 80 320 23.5 33.5 / Dimensions in mm

8 SE 03 MA xxx xx Dimension diagram SE series Switchgear with 3 HV switching chambers, manual actuation and 5 times key multiplier Handle. 250 Nm max. High-voltage terminals M8 240 26 2 20 260 320 HV-B swichting chamber HV-C swichting chamber 4x mounting for screws M0 280 Service position 48 40 45 2x aux. switches Ground position 480 Earthing terminal M8 ~300 SE 0 MA xxx xx Dimension diagram SE series Switchgear with HV switching chambers, manual actuation 340 High-voltage terminals M8 2x aux. switches Earthing terminal M8 Earthing terminal M6 280 33.5 57 238 256 4x mounting for screws M0 30 30 30 70 70 370 30

9 Mounting instructions, start up Dimensioning instructions For connection of the main contacts with a thermal current of 400 A Schaltbau recommends the use of bus bars or wires with the following dimensioning: Cable cross-sectíon > 200 mm 2 or bus bars with 25 x 8 mm Multipole disconnectors with function of earthing switch: Schaltbau recommends a cross-section of 50 mm 2 min. For earthing of the housing Schaltbau recommends a green-yellow or transparent PE-wire with a minimal cable cross-section of 0 mm 2 The minimum distances to voltage-carrying parts must be observed! The dimension drawings are provided for this purpose. Please refer to our operating manuals. Weight of different variants depends on the number of switching chambers each chamber more/less means higher/lower weight of approx. 3 kg. Depth of different variants depends on the number of switching chambers each chamber more/less means a higher/lower depth of 40 mm. Do you need some help? For selecting the disconnector, earthing switch, change-over-switch that suits your application best do not hesitate to ask our advice. Start up Before start up make sure that: The switch is properly secured to the chassis of car (check if screws are fixed) HV wires are properly connected at HV-contacts/terminals Low voltage wires are properly connected Earthing wires are properly connected to housing of device Before energize the HV system, check if configuration of HV-contacts and blades accords with HV electrical schema. Use a multimeter! Mounting position Horizontal and vertical installation are allowed! Maintenance instructions Safety instructions For detailed maintenance, safety and mounting instructions please refer to our operating manuals! Defective parts must be replaced immediately! Do not exceed the current value stated in data sheet Do not operate any handling under electrical load Before maintenance operation ensure that the devices is completely deenergized Use only original spare parts

Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 5 8829 Munich Germany Phone +49 89 9 30 05-0 Fax +49 89 9 30 05-350 Internet www.schaltbau-gmbh.com e-mail contact@schaltbau.de RoHS 20/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 2008. Quality you can count on Schaltbau Certified to DIN EN ISO 400 since 2002. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 900 since 994. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements F237/80/0 Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.com. Issued 0-208