PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Similar documents
SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

TRI-CAPACITY PACKAGE UNIT

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

Air Cooled Packaged Units

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

ISDL SERIES DUCTED SPLIT SYSTEM AIR CONDITIONERS

DRAFT. Technical Data OPA Ducted Three Phase Packaged Air Conditioners. 47 kw 96 kw

Landmark Rooftop Packaged Units

Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

The ActronAir range of air conditioners provides a solution for most applications.

NSW/ACT QLD VIC/TAS SA/NT

Air-Cooled Liquid Chiller with integrated hydraulic module

GUIDE SPECIFICATIONS CE Series Two Stage R-410A

VARIABLE CAPACITY COMMERCIAL SERIES Premium performance, flexible controls.

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

NOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

D M S 760 C01 A A 1 1

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

CHP

DESCRIPTION FEATURES

HCH6. Product Specifications

T-Class Split System Units R-410A - 50 HZ

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

NSW/ACT QLD VIC/TAS SA/WA/NT

GUIDE SPECIFICATIONS. ES Series R-410A

PRODUCT RANGE. Trade, Sales and Technical Support Enquiries Service and Warranty Enquiries

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Bosch BOVA Split System Heat Pump

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

Ducted Split System Air Conditioners

UMXCA/UMXCBA ECVA/ECVBA

Concealed Ducted Split Series R22

AHN 064 to 304 EHN/CHN 064 to 304

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

14.5 SEER HEAT PUMPS. Featuring Industry Standard R-410A Refrigerant TZPL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

CGA CXA VGA VXA CG-PRC006-E4

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

Product Data PH13NAZ. DUCTED HEAT PUMP Sizes 018 To To 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

PHB SERIES 7-1/2 and 10 TON

Ducted Split System Air Conditioners

DIRECT-DRIVE BLOWER FAN COIL AIR CONDITIONER ENGINEERING GUIDE

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

N4A6. Product Specifications

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

technical catalogue tetris KW Chiller and heat pumps air/water

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

VHIA High-Static Ducted Indoor Units - 60HZ

AQVSL/AQVSH STAR 85 to 140

CSA6. Product Specifications. SoftSound SXC 2600

LUI / LUO. Condensing Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units 11.0 EER

RCD Air Cooled Condensing Unit (50/60 Hz)

FORM NO. PTZ-806 REV. 1 HEAT PUMPS

P6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6, 7½ and 10 Ton Packaged Electric Cooling Units EER Commercial System Units

Air Cooled Packaged Units Technical Data

Enhanced Air Conditioning

Performance. Sound Levels. Impellers. Motors. Accessories

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Commercial TRI-CAPACITY Performance and efficiencies through smart engineering. That s better. That s Actron.

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

WATER SOURCE HEAT PUMPS

AIR COOLED CHILLERS WATER COOLED CHILLERS

WCA4**4. Product Specifications

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

The World Leading Air-conditioning Company

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

FSH1BG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump, Up to 19 SEER Residential System 2-5 Ton Capacities

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Bosch BOVA Split System Heat Pump

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Product Data PH13NA PH13PA FEATURES AND BENEFITS. 13SEERSplitSystemHeatPump with R---410A Refrigerant 1.5 To 5 Nominal Tons AVAILABLE SIZES:

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

2SG13 60HZ P A C K A G E D G A S / E L E C T R I C

R4H4. Product Specifications

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

JT4BD Series 13 SEER TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 13 SEER, 8.0 HSPF 3 Phase Light Commercial High Efficiency, Heat Pump

Transcription:

TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor Fans Louvre Outdoor Coil Guard Pre-charged with R410A Refrigerant Adaptive Demand Defrost UNIT OPTIONS Low Ambient Compressor Soft Starters Phase Protection Additional Full Coil Coat Protection Fault Detection Board CONTROL OPTIONS ActronAir C7-4 (BCA Compliant) 7-Day Programmable Controller with 2 Events/Day Temperature Set Back and After Hours Timer Zone Kit for Control up to 4 Zones (See Control Section) Auto, Heat & Cool Modes Auto/Continuous Indoor Fan Operation 2 Speed Indoor Fan Setting Hot Start Feature 2 Stage Cooling/Heating with 3rd Stage Boost Heat Manual Control Inputs Remote Temperature Sensors 24-Hour ON/OFF Timer Home/Building Automation ON/OFF Capability UNIT LIANCE MEPS 12 Demand Response AS4755.3.1 PACKAGE MODEL TOTAL* NETT** COOLING CAPACITY (kw) *** 35.22 33. SENSIBLE CAPACITY (kw) *** 28.99 27.27 HEATING CAPACITY (kw) ^ 33.78 35. COOLING INPUT POWER (kw) ^^ 10.55 HEATING INPUT POWER (kw) ^^ 10.37 EER 3.34 3.18 COP 3.26 3.42 FLOW (l/s) - MIN. / NOMINAL / MAX. ^^^ 1462 / 17 / 1892 SOUND PRESS. LEVEL @ 3M db(a) - LOW / HIGH 58.8 / 62.8 SOUND POWER LEVEL db(a) -- LOW / HIGH 75.8 / 79.8 POWER 415V / 3Ph+N / Hz RATED LOAD AMPS ** 23.4 FULL LOAD AMPS ^^^^ 31.4 CIRCUIT BREAKER AND CABLE AMPS 32.0 APPROXIMATE STARTING AMPS 64.0 WEIGHT (kg) 0 * Based on unit rating excluding indoor fan kw. ** Measured and tested in accordance with AS/NZS 3823.1.2. *** At 27 0 C DB / 19 0 C WB entering air temperatures and 35 0 C ambient. ^ At 0 C DB entering air temperature and 7 0 C DB / 6 0 C WB ambient. ^^ input power includes indoor fan kw. ^^^ Max. - Min. airfl ow application range. ^^^^ Full Load Amps are based on compressor and fan motors maximum expected current. See Specifi cations sheet for cable size and circuit breaker size details. Note: Use input power to estimate running cost. -00 - P1 111109

CAPACITY SELECTION DATA COOLING PERFORMANCE ENTERING TOTAL TOTAL SENSIBLE CAPACITY - kw CAPACITY AT DB TEMPERATURE ONTO COIL - 0 C DB - 0 C WB - 0 C kw 21 22 23 24 25 26 27 28 29 30 16 35.68 23.10 25.09 26.76 28.66 30.47 32.26 33.79 17 36.48 21.06 23.06 25.07 26.72 28.65 30.52 32.27 33.95 35.36 25 18 37. 19.00.99 22.99 24.99 26.99 28. 30.45 32.27 33.96 35. 37.00 19 38.56 16.87 18.93.95 22.94 24.90 26.87 28.49 30.40 32.24 34.00 35.65 39.59 14.76 16.82 18.82.87 22.84 24.83 26.77 28.42 30.33 32.18 34.00 21 40.68 14.66 16.71 18.77.77 22.76 24.74 26.73 28.32 30.28 32.15 22 41.91 14.58 16. 18.65.66 22.68 24.65 26.61 28. 30.15 16 34.46 22.45 24.42 26.08 27.97 29.81 31.51 32.88 17 35.10.42 22.39 24.38 26.06 27.97 29.82 31.58 33. 34. 18 35.98 18.33.34 22.33 24.31 25.98 27.89 29.77 31.58 33.25 34.74 35.90 30 19 36.98 16.24 18.28.28 22.29 24.25 26.22 27.83 29.73 31.57 33.31 34.90 38.00 14.12 16.16 18.19.23 22.22 24. 26.13 27.80 29.67 31.52 33.30 21 39.03 14.03 16.09 18.11.13 22.11 24.12 26.07 27.72 29.61 31.44 22 40. 13.95 16.00 18.04.05 22.06 24.01 25.97 27. 29.51 16 33.11 21.69 23.68 25.34 27.23 28.97 30.68 17 33.37 19.68 21.65 23.63 25.32 27.19 29.04 30.75 32.13 18 34.28 17. 19. 21. 23.58 25.25 27.14 29.01 30.77 32.40 33.82 35 19 35.22 15.54 17.54 19.57 21.55 23.55 25.18 27.11 28.99 30.79 32.49 33.93 36.16 13.41 15.45 17.49 19.49 21.49 23.46 25.42 27.06 28.90 30.75 32. 21 37.15 13.32 15.37 17.42 19.41 21.40 23.37 25.36 26.95 28.87 30.70 22 38.24 13.24 15.31 17.31 19.33 21.31 23.30 25.26 26.89 28.77 16 31.59.89 22.59 24.49 26.36 28.09 29.55 17 31.61 18.86.84 22.80 24.46 26.34 28.14 29.80 18 32.40 16.81 18.81.81 22.79 24.41 26.31 28.15 29.89 31.36 40 19 33.25 14.71 16.74 18.75.74 22.71 24.38 26.26 28.13 29.91 31.51 32.90 34.07 12. 14.64 16.70 18.68.69 22.65 24.32 26.22 28.06 29.89 31.61 21 35.04 12.55 14.58 16.59 18..61 22.57 24.54 26.16 28.02 29.84 22 36.08 12.44 14. 16.55 18.54.54 22. 24.46 26.09 27.96 16 29.88.01 21.72 23.58 25.43 27.05 17 29.90 18.00 19.98 21.69 23.54 25.42 27.12 18 30.32 15.94 17.97 19.93 21.66 23.53 25.41 27.21 28.80 45 19 31.14 13.89 15.91 17.90 19.89 21.85 23.51 25.38 27.21 28.89 30.25 31.90 11.79 13.81 15.85 17.85 19.83 21.80 23.47 25.32 27.16 28.94 30.51 21 32.85 11.71 13.76 15.78 17.80 19.76 21.75 23.41 25.28 27.11 28.95 22 33.78 11.63 13.71 15.69 17.72 19.71 21.67 23.35 25.25 27.10 16 28.03 19.05.76 22. 24.39 25.84 17 28.04 17.07 19.04.74 22.59 24.40 25.99 18 28.04 15.03 17.02 19.00.71 22.56 24.40 26.11 27.58 19 28.86 12.98 14.98 16.98 18.97.68 22.55 24.40 26.18 27.69 29. 10.88 12.93 14.93 16.95 18.91.86 22.51 24.35 26.15 27.82 21 30.37 10.84 12.86 14.88 16.87 18.85.79 22.46 24.32 26.13 27.90 22 31.21 10.76 12.78 14.80 16.81 18.79.74 22.43 24.26 26.11 HEATING PERFORMANCE WB TEMP ON OD COIL- 0 C HEATING CAPACITY - kw AT DB ENTERING - 0 C 16 18 22 24 TH IH TH IH TH IH TH IH TH IH -10 22.26 21.37 22.04 21.16 21.80.93 21.66.79 21.45. -8 23.62 22.44 23.40 22.23 23.15 22.00 22.97 21.82 22.75 21.61-6 24.94 23.44 24.71 23.23 24.55 23.08 24.33 22.87 24.09 22.64-4 26.39 24.28 26.15 24.06 25.97 23.89 25.74 23.69 25. 23.46-2 27.89 24.82 27.67 24.62 27.45 24.43 27. 24.21 26.96 23.99 0 29.49 25.95 29.29 25.77 29.02 25.54 28.76 25.31 28. 25.08 2 31.01 28.22 30.76 28.00 30.52 27.77 30.26 27.54 29.97 27.28 4 32.65 32.65 32.38 32.38 32.10 32.10 31.82 31.82 31.53 31.53 6 34.35 34.35 34.06 34.06 33.78 33.78 33.48 33.48 33.15 33.15 8 36.17 36.17 35.88 35.88 35.56 35.56 35.24 35.24 34.89 34.89 10 38.07 38.07 37.75 37.75 37.40 37.40 37.06 37.06 36.82 36.82 12 40.07 40.07 39.71 39.71 39.45 39.45 39.08 39.08 38.72 38.72 14 42.26 42.26 41.88 41.88 41.49 41.49 41.09 41.09 40.70 40.70 16 44.47 44.47 44.02 44.02 43.62 43.62 43.17 43.17 42.73 42.73 18 46.73 46.73 46.29 46.29 45.82 45.82 45.34 45.34 44.85 44.85 TH - Total Heating Capacity (kw). IH - Integrated Heating Capacity (kw) Includes defrost losses. FLOW CORRECTION MULTIPLIER % VARIATION -15% -10% -5% NOMINAL +5% +10% FLOW (l/s) 1462 1548 1634 17 1806 1892 TOTAL COOLING 0.972 0.982 0.991 1.00 1.008 1.014 SENSIBLE COOLING 0.919 0.947 0.973 1.00 1.027 1.053 HEATING FACTOR 0.991 0.994 0.997 1.00 1.002 1.004 1. No allowance has been made for the effect of indoor fan motor. 2. Selection tables are based on nominal airfl ows. Correction factors must be applied for selection away from these conditions. ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase. -00 - P2 110908

DIMENSIONS AND CURVE 1875 680 410 U PACKAGE UNIT - STANDARD MODEL COIL 4 OVERALL NOMINAL DIMENSION (H x W x L) = 1330 x 1875 x 1590 DUCT (H x W) = 300 x 1065 RETURN DUCT = 525 x 14 USE M12 BOLT FOR FEET MOUNTING 1590 POWER ENTRY 40mm, 25mm THIRD ANGLE 1. All dimensions are in mm unless specifi ed. PROJECTION 2. Do not scale drawing. 3. Optional Anti-Corrosive Acrylic Coated Coil available on all units. COIL 30 OUTLET 14 90 1065 285 700 810 140 300 INLET 1330 1225 1130 525 8 135 RETURN INLET 140 1 617.5 1 617.5 1 140 1515 UNIT CURVE * 4 400 3 EXTERNAL STATIC PRESSURE (Pa) 300 2 0 1 10 0 0 1100 10 1300 1400 10 10 1700 1800 1900 00 2100 20 Performance Fan Curve shown * is at Dry Coil Condition for 9x9 S - 1100W - Twin Deck Fan. FLOW (l/s) APPLICATION RANGE -00 - P3 110908

SOUND DATA Outdoor Radiated Sound Power Level (SWL) Fan Speed Sound Power Level db(a) Octave Band Centre Frequency (Hz), db 125 2 0 1k 2k 4k 8k Low 75.8 75.2 73.6 73.1 71.1 66.9 65.0 59.7 High 79.8 78.2 77.8 77.0 75.3 71.0 69.0 63.9 Indoor Outlet Sound Power Level (SWL) Airfl ow Setting Airflow Li/s Sound Power Level db(a) Octave Band Centre Frequency (Hz), db 125 2 0 1k 2k 4k 8k Nominal 17 81.0 79.5 80.1 78.0 75.8 73.2 69.5 64.5 RADIATED OUTLET Sound Power Level Sound Power Level 90.0 90.0 Octave Band Sound Power Level (db) 80.0 70.0.0.0 Octave Band Sound Power Level (db) 80.0 70.0.0.0 40.0 Low High 125 2 0 1k 2k 4k 8k 40.0 Nominal 125 2 0 1k 2k 4k 8k Octave Band Centre Frequency (Hz) Octave Band Centre Frequency (Hz) 1. Radiated sound power levels are based on ISO 3743-2. 2. Outlet sound power levels are based on ISO 13347-2. ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase. -00 - P4 110308

SPECIFICATIONS CONSTRUCTION CABINET BASE CABINET TOP AND SIDES SURFACE FINISH 1.6 mm Galvanized Steel 0.9-1.2 mm ZA & Galv. Steel 65 microns Baked Polyester Powder Coat RESSOR NUMBER PER UNIT x TYPE 2 x Scroll (Hermetic) FULL LOAD AMPS 19.4 LOCKED ROTOR AMPS 64.0 STARTING METHOD D.O.L. (optional soft starter) INSULATION TYPE 10 mm Foil Faced Polyethylene mm Expanded Polystyrene REFRIGERATION SYSTEM REFRIGERANT TYPE EXPANSION CONTROL R-410A Direct Expansion Orifi ce SOUND LEVEL * db(a) SOUND PRESS. - Low / High 58.8 / 62.8 @ 3m Distance SOUND POWER LEVEL - Low / High 75.8 / 79.8 * Sound data are based on outdoor fan s manufacturer sound level data. FACTORY CHARGE (grams) FILTER DRIER CONNECTION SIZE & TYPE FACTORY SUPPLIED / FITTED 6,910 per stage (per compressor) 9.52 mm (3/8 ) ODF Soldered Bi-Flow No ELECTRICAL See Installation Section for complete Filter Drier specifi cations. POWER - Hz 415 Volts x 3 Phase + Neutral VOLTAGE RANGE (min - max) 400V - 440V FULL LOAD AMPS * - Phase 1 31.4 FULL LOAD AMPS * - Phase 2 & 3 21.3 & 22.4 RATED LOAD AMPS** 23.4 PROTECTION DEVICES HIGH PRESSURE CUTOUT SWITCH LOW PRESSURE CUTOUT SWITCH RESSOR MOTOR TEMP. OVERLOAD Nonadjustable (Automatic Reset) Nonadjustable (Automatic Reset) Internal Thermal Cut-Out Internal Thermal Cut-Out APPROX. STARTING AMPS 64.0 OVERLOAD Internal Thermal Cut-Out IP RATING IP44 SUMP HEATER WATTS 2 x 30 W during Comp. Off Cycle IMPORTANT - The local electricity authority may require limits on starting current and voltage drop, please check prior to purchase. * Full Load Amps are based on compressor and fan motor s maximum expected current. ** Rated Load Amps are measured and tested in accordance with AS/NZS3823.1.2. CABLE SIZE & CIRCUIT BREAKER SIZE Suggested minimum cable size should be used as a guide only, refer to AS/NZS 3000 Australian/New Zealand Wiring Rules for more details. CABLE SIZE (MAIN LINE) 6.0mm 2 (SUGGESTED MINIMUM) CIRCUIT BREAKER SIZE - AMPS 32.0 ELECTRIC CONTROLS DEFROST METHOD DEFROST TYPE CONTROL CIRCUIT BREAKER CONTROL FIELD WIRING Reverse Cycle Adaptive Demand Defrost 16.0 Amps 2 Core 14 / 0. Screened Cable OPERATING RANGE It is essential that the unit is correctly sized for the application and operates within its recommended range of operating conditions as shown below. COIL TUBE TYPE Copper - Rifl e Bore FIN TYPE Aluminium - Wave FACE AREA (m sqr) 2.46 Cooling MODE RANGE INTAKE TEMPERATURE INTAKE TEMPERATURE Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB 15 o C DB FIN SPACING (per m) 472 COIL COATING Blue Hydrophilic Coil Fin Protection ROWS --- NUMBER OF S x TYPE 2 x Axial NUMBER OF BLADES PER 4 DIAMETER (mm) 5 OUTPUT kw 0.37 MOTOR TYPE / DRIVE TYPE 6 Pole External Rotor / Direct Drive SPEED CONTROL 2 Speed via Capacitor The standard type outdoor fans fi tted to this unit will only accept Pa of external static resistance. COIL Max. 24 o C DB 21 o C DB / 16 o C WB Heating Min. 16 o C DB -10 o C DB IMPORTANT - For low ambient cooling use option S. Lower ambient available on request. Contact your nearest ActronAir offi ce for more details. Low Ambient Cooling Option S On Request Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB 5 o C DB Max. 29 o C DB / 19 o C WB o C DB Min. o C DB / 15 o C WB -5 o C DB TUBE TYPE Copper - Rifl e Bore FIN TYPE Aluminium - Louvre FACE ARE (m sqr) 0.86 FIN SPACING (per m) 472 ROWS --- NUMBER OF S x TYPE 1 x Twin Deck Centrifugal Fan DIAMETER / WIDTH (mm) 240 x 240 OUTPUT kw / INPUT kw 1.10 / 1.72 MOTOR TYPE / DRIVE TYPE 3 Speed 4 Pole / Direct FILTERS All return air including fresh air must have adequate fi lters supplied and fi tted by the installing contractor. Filters must be located in accessible location between the return air grille and the unit.- ActronAir does not supply or make any provisions for return air fi lter. -00 - P5 111014

WIRING DIAGRAM ActronAir is constantly seeking ways to improve the design of it s products, therefore specifications are subject to change without notice. Please check prior to purchase. WD0700 1104

UNIT DIMENSIONS PCA340V 1875 680 410 V PACKAGE UNIT - WITH COIL VERTICAL DISCHARGE COIL 4 OVERALL NOMINAL DIMENSION (H x W x L) = 1330 x 1875 x 1590 DUCT (H x W) = 300 x 1065 RETURN DUCT (H xw) = 525 x 14 USE M12 BOLT FOR FEET MOUNTING 1590 POWER ENTRY 40mm, 25mm 300 COIL 285 TOP VIEW 30 OUTLET 14 90 1065 3 700 810 140 INLET 1330 1225 1130 525 135 RETURN INLET 140 1 617.5 1 617.5 1 140 FRONT VIEW 1515 SIDE VIEW SERVICE ACCESS AREAS GG 800 mm SERVICE CLEARANCE (. & ELECT. CTRL) AA BB 7 mm SERVICE CLEARANCE & FLOW ALLOWANCE HH COIL COIL EE DD 300 mm FLOW ALLOWANCE THIRD ANGLE 1. All dimensions are in mm unless specifi ed. PROJECTION 2. Do not scale drawing. 3. Refer Pipe Connection Details on Specifi cations Sheet. 4. Optional Anti-Corrosive Acrylic Coated Coil available on all units. 5. Suggested Service Clearance and Airfl ow Allowances are based on conditions that the spaces are free from obstructions and walkway passage of 1000mm is available. 6. Minimum service access areas are responsibilities of the installer. CC COIL DUCT WORK FF HEIGHT CLEARANCE = 10 PCA340V-00 - P7 110908