Loctite Micro Needle Valve Part Number EQUIPMENT Operation Manual

Similar documents
ml Dual Cartridge Dispenser 10:1 B Style Cartridge ml Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridge

MM10 Dual Cartridge Dispenser 1:1 & 2:1 A Style Cartridges MM10 Dual Cartridge Dispenser 1:1 & 2:1 B Style Cartridges

Loctite 300ml Cartridge Pusher Part Number EQUIPMENT Operation Manual

Equipment Operation Manual. Loctite 250ml Bottle Hand Pump Part No Loctite 50ml Bottle Hand Pump Part No

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

Frekote Adjustable Spray Applicator 6 Extension Extension Extension EQUIPMENT Operation Manual

Loctite Control Timer Part Number EQUIPMENT Operation Manual. Control Timer SEC. Technologies

EQUIPMENT Instructions. Loctite Pneumatic 300 ml Cartridge Dispenser Part Number

EQUIPMENT Operation Manual. Loctite RB10 Rotary Dispense System Part Number

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

EQUIPMENT Operation Manual. Loctite Zeta 7401 UV Chamber Part Number 98039

EQUIPMENT Operation Manual

UV Flood Curing System

Equipment Operation Manual. CA Volumetric Hand Pump Part No

EQUIPMENT. Loctite Bench Top Air Filtration System Plenum Style Part Number Air Filtration System With Arm Part Number

EQUIPMENT Operation Manual

EQUIPMENT OPERATION MANUAL. Loctite Dial-A-Seal Dispensing System

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual AD988558

EQUIPMENT OPERATION MANUAL. Loctite ZETA 7401 UV Chamber

WORLDWIDE EQUIPMENT. Hand-held Applicator OPERATION MANUAL GLOBAL AVAILABILITY GLOBAL SERVICE

EQUIPMENT Operation Manual. Loctite Advancing Slide Dispense Station. Part Number 98426

EQUIPMENT Operation Manual. Loctite Zeta 7411 UV Flood Curing System. Part Number 98027

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

EQUIPMENT # OPERATION MANUAL DISPENSING SYSTEM

Operating Manual High Viscosity Dispense Valve Item #

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

Loctite 100W UV Curing Wand System Part Number EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual. Loctite DuraPump Meter Mix System Part Numbers

EQUIPMENT OPERATION MANUAL. Loctite Zeta 7740 UV Curing Wand System

Techcon Systems TS5322 TS5322D Adjustable Mini Spool Valve. User Guide

Operating Manual. VoluDrop Dispenser UV

EQUIPMENT Operation Manual. Loctite Single Rotary Dispense Station. Part Number 98427

EQUIPMENT Operation Manual. Posi-Link Coupled Cylinder Assembly. Item No Posi-Link Controller P/N:

Techcon Systems TS5620 Series Diaphragm Valve. User Guide

7760A. EQUIPMENT Operation Manual. Loctite Zeta 7760A UV Curing Wand System Part Number: Exposure Time. Timed. Manual. Lamp Hours.

EQUIPMENT. Loctite Series 9000 Rotospray System OPERATION MANUAL. Pump Reservoir Head PRODUCT RESERVOIR

Techcon Systems TS5000 Series Rotary Valve

Techcon Systems TS7000 Series Interchangeable Material Path Rotary Valve

EQUIPMENT Operation Manual. Loctite DuraPump Meter Mix System Part Numbers

EQUIPMENT OPERATION MANUAL. Loctite Hysol Wheel Coater

Techcon Systems TS5000DMP Series Disposable Material Path Rotary Auger Valve. User Guide

Techcon Systems TS5540-MS Micro Spray Valves

Dispensing. Monitoring Systems. Loctite Fluorescence Detector, Item 98083

Straight-Bore Clutch LSCC-32, 44, 54

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

IDMHDV-120. Lever Operated Diaphragm Valve. User Manual

781Mini Series Spray Valve

xqr41v Series Needle Valve

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

FCB-450, LCB-600, MCB-800

SV1217-SS SPRAY VALVE O P E R AT I N G M A N U A L

HR-20P Pneumatically Controlled Pressure Regulator

MEX (55) QRO (442) Web Controls

DAP-625S and DAP-875S

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

2 Model 826 Dispensing Valve User Guide

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

AirPulse TM Ultra Small Dot Positive Displacement Valve

2 Model 485 Dispensing Valve User Guide

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

2 Micro-Dot Manual Syringe Dispenser User Guide

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Single Post Caliper Brake VC500

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

Paint Pumps INST Manual

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Tissue Master. User Manual

Guardian FBA Flywheel Coupling

ECLIPSE PRODUCTS. Eclipse Motor Brake. NEMA Sizes: 182, 184, 213, 215, 254, and 256 TC IEC Sizes: 100, 112, 132. User Manual FORM NO.

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

The DispensGun and components are manufactured by Nordson EFD in the U.S.A.

Reference Manual FM-200 Series

Users Guide for Ac-sync

ActuLink ABS Module - ABS-MOD-400

AIR CHAMP PRODUCTS. User Manual. BW Clutch or Brake Sheave, Pilot and Coupling Mount FORM NO. L U-1209 FORM NO.

PARTS LIST. Guardian A- Series. Material Pumps

High Output 2:1 Transfer Pump GHO

Model 340 Tune-Up Kit Instructions

Guardian Steel Gear Shaft Coupling

PARTS LIST. Guardian VR-Series. Material Pumps

Model GX Spray Gun

ECLIPSE PRODUCTS. Eclipse Servo Motor Brake Flange Mounted, Pneumatically Engaged, Spring Released Sizes 2, 3, 4, and 5.

24G621 Agitator Speed Controller Accessory

Intended Use: Explanation of Signal Word Consequences

Old Proportioning Pumps

LINEAR MOTION PRODUCTS

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

B275 Clutch Sheave, Pilot and Coupling Mount

Transcription:

Loctite Micro Needle Valve Part Number 98084 EQUIPMENT Operation Manual

Table of Contents 1 PLEASE OBSERVE THE FOLLOWING... 3 1.1 EMPHASIZED SECTIONS... 3 1.2 FOR YOUR SAFETY... 3 1.3 UNPACKING AND INSPECTION... 3 1.4 ITEMS SUPPLIED... 3 1.5 FEATURES... 4 1.6 USAGE... 4 2 DESCRIPTION... 4 2.1 OPERATING ELEMENTS AND CONSTRUCTION... 4 2.2 THEORY OF OPERATION (REFER TO FIGURE 2)... 5 2.2.1 Valve Sectional Views... 6 3 TECHNICAL DATA... 6 4 INSTALLATION... 7 4.1 TYPICAL PRESSURE TIME SET UP... 7 4.1.1 Connecting the Airline and Product Feed Line... 7 4.2 ADJUSTING DISPENSE QUANTITY... 8 4.3 SHUTDOWN... 8 5 MAINTENANCE AND CLEANING... 8 5.1 PROCEDURE FOR REPLACING LUER ADAPTER... 8 5.2 PROCEDURE FOR REPLACING NEEDLE VALVE ASSEMBLY... 9 5.2.1 Valve Components... 10 6 TROUBLESHOOTING... 10 7 SPARE PARTS MICRO DISPENSE VALVE... 11 7.1 ACCESSORIES... 11 7.1.1 Dispense Tip, Stainless Steel - Straight... 11 8 WARRANTY... 12

1 Please Observe The Following 1.1 Emphasized Sections Warning! Refers to safety regulations and requires safety measures that protect the operator or other persons from injury or danger to life. Notice: Gives recommendations for better handling of the unit during operation or adjustment as well as for service activities. 1.2 For Your Safety For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Always wear goggles when operating with pressurized air. Observe general safety regulations for the handling of chemicals such as Loctite adhesives and sealants. Observe the manufacturer s instructions as stated in the Material Safety Data Sheet (MSDS). While under warranty, the unit may be repaired only by an authorised Loctite service representative. 1.3 Unpacking and Inspection Carefully unpack the valve and examine the items contained in the carton. Inspect the valve for any damage that might have occurred in transit. If such damage has occurred, notify the carrier immediately. Claims for damage must be made by the consignee to the carrier and should be reported to the manufacturer. 1.4 Items supplied Micro Needle Valve Accessory Pack consisting of: Sample Needle Kit Sample Fluid Line, 6 Ft. Air line Tubing, 5 Ft. Fluid Fitting 1/8 NPT x 1/4 tube Operation Manual

1 Please Observe The Following (continued) 1.5 Features 1.6 Usage Provides extreme accuracy of drop size Shot sizes down to a fraction of a microliter Compact design allows for mounting flexibility Secondary seal/shut off for easy dispense tip changes Adaptable to optional reservoirs based on package size Syringe barrels mount directly onto valve Used in semi or fully automatic process applications The Micro Needle Valve is designed to dispense low to medium viscosity UV curing products with very precise deposits over a wide range of shot and bead sizes down to a fraction of a microliter. A short opening stroke provides extremely fast, positive shut-off. An external stroke control adjustment makes it easy for the operator to fine tune shot sizes. The valve's compact design allows for mounting flexibility and easy integration into automated applications. The Micro Needle Valve is easily adapted to a variety of reservoirs. It is capable of connecting to syringe barrels as small as 5ml to 30 ml. Change the luer fitting to a tube fitting and any size pressure reservoir can be used. The Micro Needle Valve provides productive solutions to many types of applications. 2 Description 2.1 Operating Elements and Construction 1 Stroke Adjuster / End Cap Actuator Air Cylinder 2 Air Inlet 3 10 Optional Mounting Bracket & Screw (Rotated for Clarity) Valve Body 4 9 Fluid Inlet 8 Luer Adapter 7 Valve Needle Rod 6 Dispense Needle 5 Needle Retaining Cap Figure 1

2. Description (continued) 1. End Cap is used as a flow control adjustment. Turn the end cap counterclockwise to increase material flow rate. 2. Air Cylinder - This design utilizes a single acting spring return air cylinder. 3. Air Inlet - The fitting supplied is a collet type fitting which accepts a 4mm tube. 4. Valve Body - Stainless steel construction. 5. Needle Retaining Cap - Captures the dispense needle and positions the dispense needle cannula against the valve shut off needle. 6. Dispense Tip - The Micro Needle Valve is specifically designed to use Loctite stainless steel cannula needles (15 gauge or smaller). 7. Valve needle rod Shut-Off - Stainless steel construction. 8. Luer Adapter - Accepts Loctite stainless steel cannula needles. 9. Fluid Inlet - Two fittings are supplied: 1/8" NPT x Luer connector and 1/8" NPT x 1/4" tube. 10. Bracket and Screw - Optional hardware PN 985281. 2.2 Theory of Operation (refer to Figure 2) The Micro Needle Valve is a pneumatically operated, normally closed, adjustable opening, needle and seat valve which is designed to be used in conjunction with a pressure-time dispense system. A pressure-time dispense system is made up of a controller/timer, a dispense valve, and a pressure reservoir. The controller directs pressurized air to the actuator of the valve through the inlet air port (1) for a pre-determined period of time. The resulting action is to retract the needle rod assembly (2) from the seat inside the dispensing tip (3) allowing material to flow from the material inlet (4) to the dispensing tip (5). At the end of the cycle the controller relieves the input air pressure which allows the spring (6) to return the needle rod back to its position to close the material path. The Micro Needle Valve is capable of interfacing with pressure reservoirs or syringe barrels. When using a pressure reservoir the adhesive is placed into a reservoir and a feed tube passes through the lid of the reservoir into the adhesive bottle. The other end of the feed tube is connected to the material inlet port of the dispense valve. When the reservoir is pressurized the adhesive flows into the valve. The higher the pressure the greater the flow rate. The adhesive contacts the pressurized air thus making the air quality a critical component of the system. Loctite recommends filtered dry air for each system. Many of the Loctite UV curing adhesive products are packaged in 30 ml syringe barrels. The Micro Needle Valve is delivered with a luer type of fitting to accommodate syringe barrels. The syringe barrel attaches directly to the Luer fitting and acts as a pressure reservoir. An airline adapter is attached to the syringe barrel and should be connected to a filter regulator, which delivers pressurized air to the syringe barrel. The pressurized air forces the adhesive directly into the dispense valve. The pressure and the time settings are the two predominate variables controlling the amount of adhesive that is dispensed from the valve. Secondary variables are the flow control adjustment which regulates the distance the needle rod travels and the orifice size of the dispense tip. When determining a suitable dispense dose it is advised to set a pressure and vary the time until the proper dose is achieved. If the time setting is too great, increase product pressure, this will allow for a shorter time element to obtain the same dose.

2.2.1 Valve Sectional Views 6 1 1 2 4 4 4.94 Secondary Shut-Off 7 1.12 3 5 Open Position Figure 2 Closed Position 3 Technical Data Size: Length - 5 inches (127 mm) Diameter - 1.1 inches (28.5 mm) Weight: 8-oz. (227 g) Port Size: Fluid Inlet: Air Inlets: Fluid Outlet: Max Fluid Pressure: Pneumatic Supply Air Quality: Wetted Parts: 1/8 N.P.T. 10-32 UNF-2B Male Luer Lock 100 psi (7 bar) min. 60 psi (4.8 Bar) max 100 psi (7 Bar) Filtered 10μm, oil free, non-condensing 303 Series Stainless Steel, Teflon

4 Installation 4.1 Typical Pressure Time Set Up To Filter, Regulator and Gauge P/N: 98099 To Reservoir 1 Liter P/N: 98090 To Controller: Single Function P/N: 98023 Analog P/N: 98079 Integrated Semi Automatic Controller / Reservoir P/N: 97007, 97010, 97017, 97020 Tube Fitting 1/8 NPT x 1/4 Tube (Included) Figure 3 4.1.1 Connecting the Airline and Product Feed Line Figure 4

4 Installation (continued) Note: This installation uses luer lock adapters shipped with the valve. Any approved material line with 1/8" N.P.T. connections will work. Refer to Figure 4. 1. If desired, mount the valve to the bracket (1) option. 2. Connect syringe to product inlet port (2) or connect material feed line to inlet port (2). 3. Connect valve actuating airline to air inlet port (3) and to an approved valve controller. 4. Pressurize material reservoir (Material pressure not to exceed 100 psi). 5. Activate the valve until all air has been purged from material line. It may be helpful to turn the valve upside down to purge air. Attach desired dispense tip (4) to the outlet luer lock adapter. 6. Secure the dispense tip with the valve needle retaining cap (5). Prior to installing the first needle tip on your valve, adjust the stroke approximately six turns counterclockwise from being fully seated to allow the needle hub to fully engage on the valves tapered luer adapter. (Note this is a spring actuated normally closed valve so the needle rod will appear to remain extended but it will retract when the needle retaining cap is assembled on the valve). The stroke adjustment must not be set to more than 4 to 5 turns counterclockwise when the valve is being operated. Setting the adjustment to more than 5 turns counterclockwise may result in damage to the valve. 4.2 Adjusting Dispense Quantity Shot size is dependent on the following factors: 1. Flow control adjustment - Turn end cap counterclockwise to increase material flow rate. 2. Length of actuation, set at controller (valve open time). 3. Material supply pressure at reservoir. 4. Material viscosity. 5. Dispense tip size. 4.3 Shutdown The valve does not need any special care for shut down periods of up to two weeks. If the valve is not going to be used for more than two weeks, cleaning the system out with Loctite Equipment Flushing Solvent P/N 12121 is recommended. 5 Maintenance and Cleaning The Micro Needle Valve is designed to dispense UV curing adhesives. Precautions have been made to protect the adhesive within the valve from exposure to UV light. Over time, curing may occur within the dispense tip and around the needle and luer assembly. Removing the luer adapter will force most of the cured adhesive off the needle. 5.1 Procedure for Replacing Luer Adapter Warning! Disconnect all material and air pressure lines before performing any maintenance on this valve.

5 Maintenance and Cleaning (continued) Disassembly, Refer to Figure 5. 1. Relieve reservoir product pressure. 2. Remove needle retaining cap (2). 3. Remove dispense tip. 4. Use a 7/16" wrench to remove luer adapter (3) and o-ring (5). 5. Examine valve needle rod (4) and clean off all cured material with Loctite Equipment Flushing Solvent P/N 12121. 6. Replace luer adapter (3) and o-ring (5) or clean luer adapter with Loctite Equipment Flushing Solvent P/N 12121. 7. Clean valve body (1) with Loctite Equipment Flushing Solvent P/N 12121. Reassembly, Refer to Figure 5. 1. Apply silicone grease (997569) onto o-ring (5) and install onto luer adapter (3). 2. Apply silicone grease (997569) onto the threads of the luer adapter (3) and install luer adapter to valve body (1). 3. Install new dispense tip. 4. Apply silicone grease (997569) onto thread of needle retaining cap (2) and install onto the luer adapter (3). 5.2 Procedure for Replacing Needle Valve Assembly Tools required: 7/64" hex wrench, 7/16" open end wrench, snap ring pliers, O-ring tool. Notice: To prevent possible damage to seal components, please follow these instructions in the following sequence. Refer to Figure 5. 1. Relieve reservoir product pressure. 2. Remove all hoses and fittings from valve. 3. Unscrew the needle retaining cap (2) and remove the dispense needle. 4. Remove the three screws (17). 5. Pull the valve housing (1) away from the air cylinder (12). 6. Remove the luer adapter assembly (3) from the valve housing (1). 7. Clean and inspect the needle rod (4) and luer adapter assembly (3) for wear and damage. Replace parts as necessary. 8. Replace O-ring (8), if necessary. Make sure to lubricate new O-ring with silicone grease (997569). 9. Remove the end cap (15) by turning counterclockwise. 10. Carefully remove the spring (14) and the two nylon washers (16). 11. Remove the retaining ring (13). 12. Pull the needle rod and piston assembly (4) straight out from the air cylinder (12). 13. Replace O-ring (11), if necessary, and apply silicone grease (997569). 14. Remove the retainer ring (7), the nylon washer (9) and the o-ring (10) from the air cylinder (12). 15. Clean and visually inspect all parts for damage. Replace parts as necessary. 16. Reinstall the o-ring (10) and apply silicone grease (997569). 17. Insert the nylon washer (9) and secure with the retaining ring (6). 18. Reinstall the needle/piston assembly (4) in the air cylinder (12). 19. Reinstall the retaining ring (13). 20. Reinstall the spring (14) and the two nylon washer's (16). 21. Reinstall the end cap (15). 22. Reinstall the luer adapter assembly (3) to the valve housing (1). 23. Align the valve housing (1) to the air cylinder (12) and reinstall the three screws (17). Notice: Alternately tighten the screws a little at a time until they are secure.

5.2.1 Valve Components Figure 5 6 Troubleshooting Type of Malfunction Possible Cause Correction No material flow. - Material pressure too low. Increase material pressure. - Valve air pressure too low. Increase valve air pressure to 60 psi. - Material cured or clogged in valve. Clean valve. - Material cured or clogged in Replace dispense needle. dispense needle. - End cap fully closed. Turn end cap counterclockwise. - The valve needle retaining cap Tighten the retaining cap. may not have been tightened enough to unseat the valve needle rod from the secondary Teflon seal. Inconsistent material flow. - Inconsistent valve air pressure. Insure that air supply is set at 60 psi. - Length of actuation too short. Adjust time. - Check for curing in dispense needle. Replace valve needle rod. Steady drip. - Cured material on valve needle rod. Clean or replace valve needle rod. - Worn seat. Replace dispense needle. - Worn valve needle rod. Replace valve needle rod.

7 Spare Parts Micro Dispense Valve Refer to Figure 5 Valve Needle Rod Kit Needle Rod and Piston Sub-assembly Item 4 98091 Piston O-ring Item 10 Flat Washer, Nylon Item 15 Needle Rod O-ring Item 9 Flat Washer, Nylon (retain washer) Item 8 Retaining Ring Item 6 Luer Adapter Assembly Kit 98092 (1) Luer Assembly Item 3 (1) O-ring Item 5 Polypak Seal, 1 pack Item 1A 98093 Fitting Kits (10 pieces) Elbow, 1/8" NPT X 1/4" tube, 10 pack 985404 Elbow, 1/8" NPT X Luer, 10 pack 98095 Actuator Assembly 98096 End Cap Item 14 Air Cylinder Item 11 Compression Spring Item 13 Retaining Ring Item 12 O-ring Item 7 Needle Rod and Piston Sub-assembly Item 4 Piston O-ring Item 10 Flat Washer, Nylon Item 15 Needle Rod O-ring Item 9 Flat Washer, Nylon (needle retain washer) Item 8 Retaining Ring Item 6 Valve Body Assembly 98097 Body and Seal Sub-assembly Item 1 Luer Assembly Item 3 O-ring Item 5 Needle Retaining Cap Item 2 Socket Head Screws Item 16 Needle Retaining Cap, 5 pack Item 2 98098 7.1 Accessories Bracket & Flat Head Screw 985281 Precision Air Regulator/Gauge/Valve, 0-30 psi with Syringe Adapter 98099 10 ml Syringe Airline adapter 97208 30 ml Syringe Airline Adapter 97245 Advancing Slide 984691 Silicone Grease 997569 7.1.1 Dispense Tip, Stainless Steel ½ Straight Dispense Needle 30 Gauge (50 pcs/box), ID Size.006", Lavender Hub 98104 Dispense Needle 25 Gauge (50 pcs/box), ID Size.010", Red Hub 98404 Dispense Needle 22 Gauge (50 pcs/box), ID Size.016", Blue Hub 98402 Dispense Needle 21 Gauge (50 pcs/box), ID Size.020", Purple Hub 98424 Dispense Needle 20 Gauge (50 pcs/box), ID Size.023", Pink Hub 98400 Dispense Needle 18 Gauge (50 pcs/box), ID Size.033", Green Hub 98398 Dispense Needle 15 Gauge (50 pcs/box), ID Size.052", Amber Hub 98396 Note: Only stainless steel needles 15 gauge or smaller can be used with the Micro Needle Valve.

8 Warranty Henkel expressly warrants that all products referred to in this Instruction Manual the Micro Needle Valve (hereafter called Products ) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be defective in either materials or workmanship or to credit the purchaser the amount of the purchase price thereof (plus freight and insurance charges paid therefor by the user). The purchaser s sole and exclusive remedy for breach of warranty shall be such replacement or credit. A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event, within (12) months after the delivery of the Products to the purchaser. No such claim shall be allowed in respect of products which have been neglected or improperly stored, transported, handled, installed, connected, operated, used or maintained. In the event of unauthorized modification of the Products including, where products, parts or attachments for use in connection with the Products are available from Henkel, the use of products, parts or attachments which are not manufactured by Henkel, no claim shall be allowed. No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel. NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT, OR IF THE SYSTEM WAS USED TO DISPENSE ANY LIQUID MATERIAL OTHER THAN LOCTITE PRODUCTS. EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS. ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER. THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE. Henkel Corporation One Henkel Way Rocky Hill, CT 06067-3910 Henkel Corporation Automotive / Metals HQ 32100 Stephenson Hwy. Madison Heights, MI 48071 Henkel Canada Corporation 2515 Meadowpine Boulevard Mississauga, Ontario L5N 6C3 Canada Henkel Ltda. Rua Karl Huller, 136 Jd. Canhema 09941-410 Diadema/SP, Brazil Henkel Capital, S.A. de C.V. Calzada de la Viga s/n Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, Edo. de México www.loctite.com Loctite is a trademark of Henkel Corporation, U.S.A. Copyright 2004. Henkel Corporation All rights reserved. Data in this operation manual is subject to change without notice. Manual P/N: 986127, Rev C, Date: 05/08/2013