Modulostar CMS10 Modular fuse-holders

Similar documents
Modulostar US10 Modular fuse-holders

UltraSafe US22 Modular fuse-holders

IEC & 2. Fuse holders with indicator light. Poles N N M M C Z D213627

IEC fuse holders & fuse disconnectors: CMS 14

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

INNOZED D0 fuse-bases with touch protection

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

LINOCUR Size D02 63A 230VAC/440VAC

INNOZED D0 fuse-bases with touch protection

MULTIVERT 1000A Main Incomer, 690VAC

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

BETA Switching Switches and Light Indicators

BSL Size 1 250A, Size 2 400A, Size 3 630A, 690VAC

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Fuse holders and fuses

MULTIVERT 250A Size 1, 690VAC

Phase + Neutral, neutral on right side

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Cylindrical fuse-link

Cylindrical fuse-link

Phase + Neutral, neutral on left side

MULTIFIX 60 Universal Bus Bar Carriers

(1,5 modules per pole)

For Info: Phone: Fax:

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors Technical data

DX³ RCCBs - ID 4P up to 100 A

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

fuses fuse holders CYLINDRICAL

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

NEOZED D0 fuse-links gg 400/440VAC

Fuse switch disconnectors

Electronic overload relay EF65, EF96 and EF146


R.C.B.O. SP / 1 module

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Protistor size 120 gr 750VDC (IEC)

TX³ RCCBs 2P up to 100 A

up to 63 A (1 module per pole)

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

IEC Low Voltage General Purpose Protection

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Electronic overload relays EF205 and EF370

E 90 range of fuse disconnectors and fuseholders Uncompromising performance

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Thermal Overload Relays

DX³ 4-pole RCBO 6000 A/10 ka

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

UL 508 Non-Fusible Disconnect Switches

Thermal overload relay TF65 and TF96

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

MS General Information Extended Product Type: MS

DX³ RCBO 6000 A Phase + Neutral, neutral right side

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Modular contactors and relays

UL 508 Non-Fusible Disconnect Switches

Surge-Trap Pluggable STPT2 Series - 40kA

Maximum R.M.S continuous current through IN - rated current fuses ( A ) Catalog Number MR10RESSORT.

Vistop TM isolating switches 63 to 160A

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

fuse holders & bases

K50H004UP cam changeover switch - 4-pole A - screw mounting

USCC & USM UltraSafe TM Fuseholders

Fuse switch disconnectors

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

500V / V /

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Short form catalogue. Motor protection & control

DX³ RCBO 6000A Phase + Neutral, neutral on left

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Fuse switch-disconnectors

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

3 - Protection components Motor circuit-breakers

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

FUSE BASES NH FUSE BASES 690V 160A 160A

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

3NP1 Fuse Switch Disconnectors up to 630 A

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

TAE pole Contactors

vertical fuse switch disconnectors

ZS4-SF1 Screw Clamp Terminal Block

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

MS25, MST25, MS20, MST20

Transcription:

Modulostar CMS10 FUSE HOLDERS, FUSE BASES AND SUPPORTS IEC CYLINDRICAL FUSE HOLDERS FEATURES & BENEFITS The innovative and comprehensive Modulostar range of Mersen fuse-holders. are finger-safe under IEC standards to an IP20 grade of protection, including fuse changing (with the flick of a finger). are available in 1, 2, 3 or 4 poles, with or without visual blown fuse indicator, in IEC version or IEC + UL version. Multi-pole units can also be field assembled by ordering pin-ties assembly kit. Modulostar range is made of tough and durable thermoplastic or thermoset material. TECHNICAL DATA OVERVIEW Voltage AC 690 VAC Voltage DC 690 VDC Amper (A) 32 A SCCR 200kA Mounting Installation on to DIN rails to EN 60715 Product Size For cylindrical fuse links 10.3x38.1 am, gg and 10.3x38 Mersen Protistor and HP6M fuse-links Number of Poles 1 to 4 poles Finger safe Degree of protection: IP20 Optional visual blown fuse indicator DIN rail mounting Modular design Lockable Multi-pole assembly kit available Sealable in closed and open position Plastic material UL94V2 mini Flame retardant materials with glow wire flammability index to 960 C Schock and vibration tested for marine and railway applications APPLICATIONS All circuits up to 690V for protection of motors, transformers, low voltage distribution, control circuits, drive protection Non-load operation STANDARDS IEC 60269-2 and IEC 60947-3 Compliance RoHS Compliant Plastic material: NF 16101 & 16102 Requirement 2 Compliant EP.MERSEN.COM 1

PRODUCT RANGE Modulostar fuse-holders for 10.3x38.1 fuse-links, without indicator Reference Number of poles/ phases Design Weight Package CMS101 CMS810N D305006 N CMS10 neutral conductor 65.8 g 12 CMS101 T305020 1 CMS10 single pole 61.3 g 12 CMS101N V305021 1 + N CMS10 single pole + neutral conductor 0.1316 kg 6 CMS102 W305022 2 CMS10 double pole 0.1216 kg 6 CMS103 X305023 3 CMS10 triple pole 0.1975 kg 4 CMS103N Y305024 3 + N CMS10 triple pole + neutral conductor 0.2633 kg 3 CMS104 Z305025 4 CMS10 quadruple pole 0.2433 kg 3 CMS102 CMS103 CMS103N CMS101I Modulostar fuse-holders for 10,3x38,1 fuse-links, with indicator Reference Number of poles/ phases Design Weight Package CMS101I A305026 1 CMS10 single pole 60.8 g 12 CMS101NI B305027 1 + N CMS10 single pole + neutral conductor 0.1316 kg 6 CMS102I C305028 2 CMS10 double pole 0.1216 kg 6 CMS103I D305029 3 CMS10 triple pole 0.1825 kg 4 CMS103NI E305030 3 + N CMS10 triple pole + neutral conductor 0.2633 kg 3 CMS104I F305031 4 CMS10 quadruple pole 0.2433 kg 3 EP.MERSEN.COM 2

TECHNICAL DATA SPECIFIC USAGE CONDITIONS Ambient temperature >20 C 30 C 40 C 50 C 60 C Derating factor (I e) 1 0.95 0.9 0.8 0.7 No of poles (side by side) 1 to 3 >/= 4 Derating factor of current (I th) 1 0.9 CMS10 Nominal current of fuse-link gr 20 A 25 A 30 A 32 A Max. operational current in fuse-holder 19 A 22 A 25 A 27 A Cable wire section 2.5 mm² 4 mm² 6 mm² 6 mm² CMS10I Size 10x38 10x38 Number of poles/phases 1, 1+N, 2, 3, 3+N, 4 1, 1+N, 2, 3, 3+N, 4 Conventional free air thermal current with fuse links I th 32 A 32 A Power dissipation at I th 3 W 3 W Utilisation category AC20B/DC20B AC20B/DC20B Rated insulation voltage U i 690 V 690 V SCCR 200 ka 200 ka Rated impulse withstand voltage U imp 6 kv 6 kv Degree of protection IP 20 IP 20 Voltage limit for blown fuse indicator - 230 to 690V AC/DC Indication System - with indicator Connection Max. tightening torque: 2.2Nm (19lbs.-in) Rigid wire = 1-16mm² (16-6AWG) Multistrand wire = 0.75-10mm² (18-8AWG) PZ2 or flat 5.5x1mm screw drivers recommended (max. diameter 6mm) Operating temperature -25 C to 60 C -25 C to 60 C Storage temperature -25 C to 80 C -25 C to 80 C Vibration Shock Withstand on the 3 main axis*: Sinusoidal vibration testing according to IEC 60068-2-6 2 to 13Hz x= 1 mm peak 13 to 100Hz y= 0.7g peak according to french marine application Random vibration testing according to IEC 61373 Shock testing according to IEC 61373 Shock testing according to IEC 60068-2-27 15g/11ms/18 shocks * for specific usage please contact us Max. tightening torque: 2.2Nm (19lbs.-in) Rigid wire = 1-16mm² (16-6AWG) Multistrand wire = 0.75-10mm² (18-8AWG) PZ2 or flat 5.5x1mm screw drivers recommended (max. diameter 6mm) Withstand on the 3 main axis*: Sinusoidal vibration testing according to IEC 60068-2-6 2 to 13Hz x= 1 mm peak 13 to 100Hz y= 0.7g peak according to french marine application Random vibration testing according to IEC 61373 Shock testing according to IEC 61373 Shock testing according to IEC 60068-2-27 15g/11ms/18 shocks * for specific usage please contact us EP.MERSEN.COM 3

DIMENSIONS Modulostar CMS10 fuse-holders for cylindrical fuse-links class 10x38mm Dimensions in mm ACCESSORIES CMS8010PAK + fuse-holder TAGLOCKCMS810 LOCK Kit for multi phase connection Locking devices Reference Description Weight Package CMS810PAK Z233725 Links for connection of multipole units 0.5 g 12 Reference Description Weight Package TAGLOCKCMS810 A235773 Locking kit (Tag and lockout) 9 g 1 LOCK M223525 Padlock 0.475 kg 1 EP.MERSEN.COM 4

ACCESSORIES Power supply Reference Description Application Weight Package TBB1A TBB1C TBB1A TBB1C TBB23A TBB23C D210315 E210316 F210317 G210318 1 phase axial incoming power supply 1 phase lateral incoming power supply 2 & 3 phases axial incoming power supply 2 & 3 phases lateral incoming power supply 90A 10.1 g 50 90A 10 g 50 90A 23.3 g 50 90A 23.1 g 50 TBB23A TBB23C Wiring bars / Insulated bus bars Reference Description Application Weight Package CMS810BB4F3 CMS810BB3F4 CMS810BB2F6 CMS810BB1F13 CMS810BB4F3 CMS810BB3F4 CMS810BB2F6 CMS810BB1F13 X210309 W210308 V210307 T210306 quadruple pole, 10 mm², triple pole, 10 mm² double pole, 10 mm², single pole, 10 mm², 100A, for installation of 3 100A, for installation of 4 63A, for installation of 6 63A, for installation of 13 120 g 10 84 g 10 80 g 10 33.5 g 10 EP.MERSEN.COM 5