Camper Caravan. Intervention Vehicles. Offroad. Boat. Innovative Electronics for Mobile Use. Made in Germany. Product Catalogue 2014

Similar documents
Level Measuring Sensor for Diesel Fuel Tanks

Installation and Connection: Installation and Operating Manual

Installation and Operating Manual

BETA Switching Switches and Light Indicators

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

Operating instructions Binary level sensor. LI214x /00 04/2016

Compact System NRGS 11-2 NRGS Original Installation Instructions English

TRADE PRODUCTS. Electronic systems for recreational vehicles Supplying controlling indicating

The BERNSTEIN CS-3000

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

better measurement Simply a question of

The right choice for your application. Pressure sensors from ifm.

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

Die changing technique

Operatingmanual. Mehrsprachige Anleitung unter Multilingual manuals at. pro BENNING TRITEST BENNING BENNING BENNING.

Thermal flow sensor TFS-35

OPERATING INSTRUCTIONS

Lighting conditions. Always one idea ahead.

Differential pressure gauge Model , copper alloy Model , stainless steel version

vertical fuse switch disconnectors

B kv T&D GAS INSULATED SWITCHGEAR

ATEX FLASHLIGHT HL10 EX

SPT- I / U PRESSURE TRANSMITTER for general applications

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Cochran Undersea Technology

Continuous level sensor NSK

Solar Controller MPP 150 Duo Digital No Charging Capacity 12 V / 11.5 A, Solar Power up to 150 Wp

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT

2014 / Verlichting

Solenoid Operator 0516 / 1216

Installation and Operating Manual Solar Controller

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

SECTION #1 - The experimental design

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

LED CONVERTERS FOR LED MODULES 24 V

Solenoid Operator 0513 / 1213

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

LTX RF LEVEL SENSOR. Instruction Manual

Functions Technical information - Actuator 24 V. Features. General information. lindab we simplify construction

PLUTO SPOTLIGHT - LED. Features include. Applications. Benefits

CONTACTOR, AC-3 4 KW/400 V, 1 NC, DC 24 V, 3-POLE, SIZE S00, SCREW CONNECTION. General technical data: Main circuit: product brand name

VEGAMET 307 / 308. TIB Technical Information Operating Instructions VEGAMET 308. Signal conditioning instrument. for continuous level measurement

General Information Hydrants and Flushing Valves

IVS Distribution System. IVS - Table of Contents

Emergency lighting units PC COMBO

Dynamic Elements Linear Slides Mechanical Drive Elements Accessories for Mechanical Drive Elements

Servo solenoid valves with on-board electronics (OBE)

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

FLUX FOOD Certified conformity. New!

Thermal flow sensor TFS-35

FLUX FOOD Certified conformity. More than just pumps

Magnetic Level Gauges

High Voltage Holiday Detectors & Accessories for Coatings, Linings and Wrappings.

VAG TELEMAX Stem Extensions

A real all-rounder Flexible control of both direct and alternating currents The innovative S 200 M UC

Hahn Serie 60 AT. Universal hinge for versatile application. More modern look Improved technology

innovative and powerful Medical lamps

y, [ S Technical Symbols r = mm Radius Weight (total) new

Emergency lighting units PC COMBO

Magnetic Level Gauges

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

WOOOM INSTRUCTION MANUAL

Suspension System CS-3000

BUILDING AUTOMATION CONTROL TECHNOLOGY SENSOR TECHNOLOGY PRODUCT CATALOGUE Intelligent solutions for intelligent people.

EARTHING YOUR QUESTIONS ANSWERED

A company of ThyssenKrupp Elevator. ThyssenKrupp Aufzugswerke. Operating Manual. Oil buffer

Orbipore CPS91 and CPS91D

Operating Instruction Manual for Energy Management System EBL 99 C, Art.-Nr Seite 1 / 7

ts 97 Cam-action door closer in Contur design

Temperature sensors. Fluidcontrol


SEA FLASH. A small, robust, high powered automatic flashing SOLAS approved Lifejacket Light.

PURE SINE WAVE DC TO AC POWER INVERTER

Signal lamps RS, RSB A20. Technical data RS, RSB. Dimensional drawing of RS, RSB. Number of poles Rated voltage Un

Leading the way in hazardous areas Features EATON

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Attention please! Bosch rotating beacons

RAILWAY TORQUE WRENCH LDB-10 THE UNIVERSAL GENIUS. formerly

Junction boxes. X series

Explosion protected terminal boxes type, GHG 72.

Cylinder Pressure Sensor

Phocos CML-V2. Solar charge controller. User Manual (English) Dear customer,

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

better measurement Simply a question of

96W Colored LED Light Bar - Completely Submersible 'L X 200'W Spot VDC Lumens

HERZ Electronic room thermostat analog and digital

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

Your new LM controller is a state-of-the art device which was developed in accordance with the latest

Installation Instructions, TBLZ-1-23-aa Pressure Transducer GOLD/COMPACT/MIRUVENT

Servo solenoid valves with positive overlap and on-board electronics

Technical Datasheet P-30/P-31. Standard transmitter.

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Mounting and Operating Instructions EB 8091 EN. Pneumatic Control Valve Type and Type Type with 120 cm 2 actuator

WBS 3000 Water Bottom Sensor for fuel oil and chemical storage tanks Installation and Operating Instructions

» BEDIA Level monitoring sensors with approvals of the classification societys

CONTACTOR, AC-3 15 KW/400 V, AC 110V 50HZ/120V 60HZ 3-POLE, SIZE S2, SCREW CONNECTION. General technical data: Main circuit: product brand name

HFS - High Frequency Limit Level Sensor

Transcription:

Camper Caravan Intervention ehicles Offroad Boat Innovative Electronics for Mobile Use Product Catalogue 2014 Made in Germany

OTRONIC Level Measuring Systems Precise Tank Control OTRONIC System for Camper, Caravan, Boat Being forced to leave the nice parking lot by the sea prematurely because of an empty fresh water tank or full feces tank only happens once. From the establishment on the market, OTRONIC tank display systems have proved to be successful due to precise measuring technology, high quality and high reliability to be able to plan the next supply or disposal station before. The OTRONIC tank displays consist of a display unit and of a suitable measuring sensor at the tank. Only 2 cables between tank and display are required. Thus, the complete measuring unit is also ideal for later integration into existing systems. Depending on the place of installation and case of application, different measuring sensors (tank sensors) are available for precise electronic measurement of the level without any parts being mechanically moved. The used capacitive measuring method for level measuring is robust and offers a variety of application cases. It is suitable for metal tanks and for plastic tanks, as well as for any kind of water (fresh water, sewage water, feces). It ensures precise measuring results and high operating safety. A special execution also allows the measurement of Diesel tanks. The measured value is sensed electronically and will be led as electric signal to the display unit by means of only 2 cables. The power supply to the electronic measuring instruments at the tank is effected from the display. In quiescent condition, the tank transmitters are dead. The standard delivery includes detailed installation and operating manuals allowing also retrofit of the units in the vehicle at any time. Being specially adapted, the measuring system does not allow measuring sensors/display units of other brands or an operation with the OTRONIC tank displays for intervention vehicles and fire fighting vehicles (page 26-27). OTRONIC Info Panel Combined Control of Tank and Battery From the establishment on the market, the OTRONIC info panel has proved to be successful, and now its functions had been extended. It is very much in demand, since it takes over the most important control and switching tasks in the camper. Moreover, it is designed particularly compact. The unit controls the fresh water tank, the sewage water tank, the feces tank, as well as the board battery and the starter battery. Besides, it is equipped with a main switch for the board battery and a pump main switch for the fresh water supply. Of course, both units are equipped with activation control. The board and starter battery can be supervised by means of the voltage display on the left side of the Info Panel Pro. The luminous spot display supplies a quite precise display of the battery voltage rates, since also the intermediate values are well legible due to the different brightness of the adjacent luminous spots. At the push of a button, the voltage of board or starter battery can be selected, or the display can be switched-off. In case of low battery voltage rates, red pilot lamps indicate that soon battery recharging is required. The tank levels are represented in form of clearly arranged luminous bars with 10 light-emitting diodes in three colours allowing that the tank levels can be read conveniently at a glance. The displays are working continuously, since intermediate results are displayed in variable brightness. Thus, also tendencies can be recognised at once. During refuelling and defuelling of the tanks, the continuously raising or dropping display shows a direct image of the instantaneous level allowing complete control of the procedure. Also the continuous operation of the display contributes to this control. At the touch of a button, the display can be switched-on or -off, or it is switched-off automatically after approx. 10 minutes. The standard tank display on the right side of the Info Panel Pro additionally can be switched to two measuring inputs (e. g. sewage water and feces tank). Please choose for each used tank display one of the OTRONIC Tank Transmitters according to tank volume, tank height and mounting possibility at the tank from the selection table measuring sensors on page 24. Tank displays, which are not required (such as feces) are simply left free. The Info Panel Pro is protected against reverse battery and overload. The connections are easily accessible and the free ends are labelled and equipped with 6.3 flat connectors (power supply connections) and pluggable terminal screws (signal connections). Detailed installation and operating manual, as well as drilling jig for the furniture cutout are included in the standard delivery scope. The small dimensions of the front panel and the particularly small mounting depth of only 15 allow an installation at almost any location. Storage space, which might be located behind, can be used further. When being switched-off, unit and tank transmitter are completely dead. For 12 and 24 operation. Observe: The individual tank displays of the Info Panel Pro can also be operated with 2 tanks (such as inside tank/outside tank, suer/winter operation, auxiliary tank etc.) For switching, separate switches 2x UM are suitable, such as the Switch Panel 16 A S, order no. 1289, or Switch Panel 2x 16 A S, order no. 1291, see page 32. Former measuring sensors, tank transmitter sets and tank probe are working according to the conductive measuring method (conductivity). Due to the 7-stage measurement they are no longer suitable for continuous operation at the Info Panel Pro. 12 24 oltage Current Consumption ma Switching Current Main Sw. max. A Switching Current Pump max. A Dimensions Assembly Dimensions Info Panel Pro 5330 6330 12 or 24 0-50 16 10 200x55x18 175x43x12 90 Mark of conformity: CE, E Test (EM/Automotive Regulations) Delivery Scope: Flat connector, fastening screws, manual, drilling jig Weight g Info Panel Pro 22

Level Measurement Technology s for fresh water, sewage water, feces and Diesel tanks The OTRONIC tank displays had been designed for precise level measuring, and they are suitable for any tank material and tank size. The units vary in the arrangement of the three-colour display light-emitting diodes at the range ends and in the symbols imprinted on the front panel. The tank levels are represented in form of a clearly arranged luminous bar with 10 lightemitting diodes in three colours allowing that the tank levels can be read conveniently at a glance. The displays are working continuously, since intermediate results are displayed in variable brightness. Thus, also tendencies can be recognised at once. During refuelling and emptying of the tanks, the continuously raising or dropping display shows a direct image of the instantaneous level allowing complete control of the procedure. Also the continuous operation of the display contributes to this control. At the touch of a button, the display can be switched-on or -off, or it is switched-off automatically after approx. 10 minutes. The display units are executed as panel version matching to the OTRONIC modular system. The appearance (identical height 85 ) is adapted to the other OTRONIC display units. Of course, it is possible to retrofit a single display in the vehicle. The small dimensions of the front panel and the particularly small mounting depth of only 15 allow an installation at almost any location. Thus, storage space, which is located behind, can be used further. The units are protected against reverse battery and overload and can be easily connected to the unit rear by means of terminal screws. and operating manual, as well as drilling jig for the furniture cutout, are included in the standard delivery scope. Depending on the case of application and on the tank, one of the OTRONIC tank transmitters may be used: Tank Electrode 15-50 K, Tank Sensor FL or Tank Sensor Diesel 010. Like the transmitters, these displays are suitable for 12 and 24 operation. Please select the appropriate tank transmitter from the selection table measuring sensors on page 24 according to: Tank volume possibility at the tank. Observe: It is also possible to assign 2 tanks to the display units (such as inside/outside tank, suer/winter operation, auxiliary tank etc.). For switching, separate switches 2xUM with push-on connection are suitable, such as the Switch Panel 16 A S, order no. 1289, or Switch Panel 2x16 A S, order no. 1291, see page 32. Former measuring sensors, tank transmitter sets and tank probes are working according to the conductive measuring method (conductivity). Due to the 7-stage measurement, they are no longer suitable for continuous operation at the tank displays. Current Dimensions Assembly Dimensions Weight s oltage Consumption ma g Fresh Water S 5311 12 and 24 1-30 47x85x20 29x63x18 25 A Sewage Water S 5313 12 and 24 1-30 47x85x20 29x63x18 25 B Feces S 5315 12 and 24 1-30 47x85x20 29x63x18 25 C Diesel S 5317 12 and 24 1-30 47x85x20 29x63x18 25 D Mark of conformity: CE, E Test (EM/Automotive Regulations) Delivery Scope: Fastening screws, manual, drilling jig General Example OTRONIC s S A B C D 23

OTRONIC Level Measuring Systems Precise Tank Control A Tank height 15-50 cm, adjustable according to DIN 2001-2 from outside OTRONIC Measuring Sensors General Information Suitable for plastic and metal tanks Insensitive to soiling and deposits in the water No mechanically moved parts Robust fully-electronic capacitive measuring method The tank transmitters measure the tank level, and the measured value will be led to the display unit by means of only 2 cables. The 12 or 24 power supply of the tank transmitters is effected from the display. In quiescent condition, they are completely dead. The electronic system (IP 67) is sealed and frost-proof, thus being also suitable for problematic locations, such as at underfloor tanks! All OTRONIC measuring sensors are working independently of pressure. Therefore, a falsification of the measured values in case of overpressure in the tank, pressure filling etc. is avoided. The standard delivery includes a protection against reverse battery, overvoltage, short-circuit and overload. Function: With the capacitive measuring method an insulated measuring electrode and the surrounding medium (water) are forming an electric capacitor. With increasing level, also this capacity will be increased. The electronic system evaluates this effect by means of a small alternating voltage rate and gives an electric signal to the display unit, which is equivalent to the level. Apart from the continuous measurement, the further advantage of this measuring method is its deep action and thus the insensitiveness to soiling, deposits and solids in the tank. Depending on the type of transmitter the insulated measuring electrode is executed as stick probe or flexible cord probe for various installation possibilities, tank heights and mounting situations at the tank. from inside B Tank height 30-100 cm, adjustable Measuring Sensors for Water These tank sensors had been designed particularly for level measuring of water and hydrous media (fresh water, sewage water, grey water, industrial water, feces) in metal or plastic tanks. Thus, they are universally applicable. The measuring electrode can be easily shortened to the height of the tank, and the precise full adjustment is effected by an adjusting device at the unit. In case of Tank Electrode 15-50 K also a dry adjustment is possible with the help of a scale. The Tank Electrode 15-50 K can be installed from inside or outside on the tank top. In contrast to sewage water and feces tanks (sludge fromantion), fresh water tanks can also be installed at the lower side of the tank. Easy adaptation to the existing tank height Linear, continuous signal of the level Suitable for 12 and 24 continuous operation Tank Electrode 15-50 K: Tank Sensor FL: Stick electrode, can be cut easily to the tank height mounting diameter 38, flange diameter 46.5 coupling ring PG 29, cable 50 cm Flexible cord probe, can be cut easily to the tank height Only for tanks with cleaning aperture For plastic tanks: Wall thickness max. 8 Connection by means of terminal screws Measuring Sensor oltage at the tank min.-max. cm Tank Electrode 15-50 K 1 5545 12 and 24 Top/Bottom 15-50 A Tank Sensor FL 2 5530 12 and 24 Top/Laterally 30-100 B Mark of Conformity: CE, E Test (EM/Automotive Regulations) Delivery Scope 1 : Packing ring, coupling ring PG 29, connection cable 50 cm, manual Delivery Scope 2 : Flexible cord probe, tank wall bushing, stainless steel conductor, fastening screws, manual Accessories: Switch Panel 16 A S, order no. 1289 or Switch Panel 2x16 A S, order no. 1291, see page 32: Single switch 2xUM with push-on connection to be able to use the display for a second tank (such as inside/outside tank, suer/winter operation, auxiliary tank etc.) 24

Level Measurement Technology Selection Table Measuring Sensors (1 each Tank) for hydrous media Display Unit 12 and 24 Fres Water 5311 Sewage Water 5313 Feces 5315 Info Panel Pro 12 24 5330 Art.-Nr. 6330 Suitable Tank Transmitter for 12 and 24 12 and 24 Possibility at the Tank in cm min. - max. Tank Material Ku = Plastic Me = Metal Tank olume Tank Electrode 15-50 K 5545 Top/Bottom 15 50 Ku / Me - - A Tank Electrode 15-50 K 5545 Top 15 50 Ku / Me A Tank Sensor FL 5530 Top/Laterally 30 100 Ku / Me B Tankelektrode 15-50 K 5545 Top 15 50 Ku / Me A Tank Sensor FL 5530 Top/Laterally 30 100 Ku / Me B Tank Electrode 15-50 K 5545 Top/Bottom 15 50 Ku / Me A Tank Sensor FL 5530 Top/Laterally 30 100 Ku / Me B Fresh Water Sewage Water Feces Measuring Sensor for Diesel The OTRONIC Tank Sensor Diesel had been particularly designed for level measuring of Diesel tanks in metal or plastic execution. It is installed at the tank top. The measuring electrode can be easily shortened to the height of the tank, and a precise calibration is effected at the touch of a button, separately for empty and full. Remark concerning functions and safety: The OTRONIC Tank Sensor Diesel had been designed exclusively for operation with Diesel fuel. Other combustible or explosive media, as well as water and hydrous media, are not admissible. Easy adaptation (by cutting) to the existing tank height Linear, continuous signal of the level Safety due to internal test procedures being executed continuously (processor control) Mounting diameter 63, flange diameter 85 Connection cable light plastic-sheathed cable, 1 m length For 12 and 24 operation Measuring Sensor oltage at the Tank min.-max. cm Tank Sensor Diesel 010 5586 12 and 24 Top 15-25 C Tank Sensor Diesel 010 5588 12 and 24 Top 15-35 C Tank Sensor Diesel 010 5590 12 and 24 Top 15-50 C Mark of Conformity: CE, E Test (EM/Automotive Regulations) Delivery Scope: Packing ring, fastening screws, manual C Tank height 15-50 cm, adjustable Diesel S for Tank Sensor Diesel 010 25