CI/Sf (35) Xy pril 06 XIOM CIRCLE & CURVED CNOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles Installation uide
PREPRTION SUSPENSION POINTS Suspension points should be determined before installing the canopy. See the recommended suspension point matri on the last page of this manual. XIOM CIRCLE & CURVED CNOPIES - COMPONENTS* Item Nr. Description 6 4 06 XIOM Circle and Curved Profile C0 Primary C-Channel 30 40 33 Prelude Peakform Main Runner T5 or 3 40 3 Prelude Peakform Main Runner T4 INITIL RECOMMENDTIONS XIOM Circle & Curved Canopies should always be installed in accordance with all applicable building codes and regulations. XIOM Circle & Curved Canopies, as any other architectural feature located in the ceiling plane, may obstruct or skew the eisting or planned fire sprinkler distribution pattern or even delay the activation of the fire detection system. Designers and installers are advised to consult a fire protection engineer for guidance on the proper installation techniques where fire detection or suppression systems are present. ny additional load (such as light spots) MUST NOT be suspended from the canopy but independently from the soffit. XIOM Circle & Curved Canopies should be always installed on a horizontal plane. XIOM Circle & Curved Canopies are only suitable for indoor applications. The XIOM Circle & Curved Canopies can reach a significant weight. In order to minimise the risk of injuries, the canopies should be installed by a minimum of people. Suspension elements such as threaded rods, anchors or any other element not included in the kit must be chosen to ensure a safe installation and follow local regulations. It is recommended to assemble the canopy under the final ceiling location to avoid later movement. 5 30 0 33 Prelude Cross Tee 600 mm T5 or 3 0 Prelude Cross Tee 600 mm T4 WDN 36 339 56 57 46 47 348 T bar hanger Splice connector T-bar connector clip (Threaded) + M4 bolts (cross head) Perimeter fill-in for 5 mm grid Perimeter fill-in for 5mm grid Perimeter fill-in for 4 mm grid Perimeter fill-in for 4mm grid Channel bracket (ircraft cable included in the kit) loves supplied in the kit are used to prevent marking the components during installation. They are NOT meant to be used as safety gloves. C 97 Clamp for C-Channel iom Circle and Curved Canopy is a modular suspension system supplied kit with ready-to-assemble components (partly listed above). * For further detailed information regarding any of these items please refer to the parts list included in the carton ll the profiles on the kits are cut and pre-drilled following the dimensions of the Canopy.
TE CSSIS ON TE FLOOR Choose the position of the perimeter section (roove facing up or downwards) * The.8.4 m module is used as an eample only Match the codes (-, -, etc) of the perimeter ends XIOM straight Profiles 4 XIOM curved Profiles 6 Splice connectors 3 TE PRIMRY RID ON TE FLOOR * The.8.4 m module is used as an eample only 3 C-Channels 6 T bar Connectors 6 angers OPTION 3 - ircraft cable OPTION - Quick hanger* OPTION - 6mm Threaded rod* * not included in the kit 3 4 Match the positioning stickers attached to the Chassis IMPORTNT NOTE: When there is not enough room for the screwdriver please install the T-bar connectors upside down. Self tapping screw to secure C-Channel position Check positioning arrow on the C-Channel
4 TE RID - MIN RUNNERS IN TE IR * The.8.4 m module is used as an eample only Main Runners 4 T bar connectors 4 Perimeter fill in 3 4 Manoeuvre the plate until parallel to the grid Match the positioning stickers attached to the Chassis DO NOT TITEN YET
5 TE RID - CROSS TEES IN TE IR 5 * The.8.4 m module is used as an eample only Manoeuvre the plate until parallel to the grid Match the positioning stickers attached to the Chassis TITEN TE SCREWS Special Cross Tees Standard Cross Tees 3 Standard Cross Tees 6 Special Cross tees 6 T bar Connectors 6 Perimeter fill in Use a measuring tape to check the centering of the Main Runners and Cross Tees and readjust if needed. Use self-tapping screws at the marked height line, once the Main Runner and Cross Tees have been centred. 6 TE TILES For Tegular 8 mm & MicroLook 8 mm edge reveal tiles ll perimeter tiles are cut on site (oard edge; see drawing page 3) and resting with the face on the XIOM Profile.. Cut down the perimeter tiles using the templates provided (See the layout below) and install them accordingly.. Install the full size/centre tile/s. * The.8.4 m module is used as an eample only Tile Layout C E D F F C D F.8m Dia Canopy CS CI 33 5 CS CI 33 4 E E I I I D C.4m Dia Canopy CS CI 44 5 CS CI 44 4 F C E D.8m.4m Canopy CS CU 43 5 CS CU 43 4 I I I.4m.4m Canopy CS CU 44 5 CS CU 44 4 I.8m 3m Canopy CS CU 53 5 CS CU 53 4.4m 3m Canopy CS CU 54 5 CS CU 54 4 Standard tiles (NOT INCLUDED) Set of templates 3m 3m Canopy CS CU 55 5 CS CU 55 4
PYSICL DT Material Frame: Etruded aluminum profiles rid & accessories: ot dipped galvanised steel Tiles: Mineral fibre tiles (NOT included in the kit) 0 Suspension points 500 500 Surface finish Frame: Polyester powder coated rid capping: aked Polyester paint Colour: rmstrong lobal White Warranty For more information, please contact your local rmstrong office or consult the rmstrong website. 400 500 0 400 400 00 00 00 00 00 4 pre-packed, ready-to-assemble XIOM Circle & Curved canopy kits, in 7 standard modules, will be available either in 5 mm or 4 mm grid 800 500 00 900 Module rid system rid system 5 mm XL 4 mm XL Item Nr. Item Nr. Circle 800 CS CI 33 5 CS CI 33 4 Main Runner C Channel anger Point Circle 400 CS CI 44 5 CS CI 44 4 Curved 400 800 CS CU 43 5 CS CU 43 4 Curved 400 400 CS CU 44 5 CS CU 44 4 Curved 0 800 CS CU 53 5 CS CU 53 4 Curved 0 400 CS CU 54 5 CS CU 54 4 Curved 0 0 CS CU 55 5 CS CU 55 4 XIOM Circle & Curved canopy kits are only available in specific markets, please contact rmstrong Technical Sales. Ceiling tiles RE NOT included in the kit. Ma. tile load : 0kg/m² For further information on customized size modules please contact rmstrong Technical Sales. United Kingdom / Republic of Ireland rmstrong World Industries Ltd. uilding Products Division rmstrong ouse, 38 Market Square Ubridge U8 N 0800 37849 (UK) 800 40900 (ROI) Fa: + 44 (0) 895 7487 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie sales-support@armstrong.com FREEFONE www.armstrongceilings.eu dvisory note ll photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochure as to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons in printing, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sample of the product. ll statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating to rmstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products in writing that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are in accordance with the terms and conditions of sale of the selling company. ll product specifications are subject to modifications without prior notice. Produced by The Design Quorum, September 05