V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE

Similar documents
V2000UB UBG type TRV Body RADIATOR VALVE WITH UNLIMITED CARTRIDGE

V2000Kx KV type TRV Body RADIATOR VALVE WITH KV-SPECIALIZED CARTRIDGE

V2000Kx KV type TRV Body

V2000FS FS type TRV Body FINELY PRESETTABLE RADIATOR VALVE WITH FLUSH POSITION

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V Verafix Design Thera Design Edition - Lockshield Valve WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

V5032. Kombi-2-plus Manual double regulating balancing valve. Product specification sheet

V5003F Kombi-VX PRE-SETTABLE FLOW CONTROL VALVE

V5000, V5010 Kombi-3-plus BALANCING AND SHUTOFF VALVES

Valencia Radiator Valve Range

4-way Distribution Valve

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

High capacity valve body, type RA-G

HS10S-FA. Water station. Product specification sheet

HS10S-FA. Water station. Product specification sheet

Mikrotherm F. Manual Radiator Valves With presetting

V5049A FLANGED LINEAR VALVE PN25/40

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

RTL. Floor Heating Controller Return temperature limiter with and without presetting

Regutec F. Return Lockshield Radiator lockshield

Automatic balancing valves ASV-PV DN (3rd gen.)

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Dynacon. Floor Heating Manifolds Floor heating manifold with automatic flow control

VBGx-xx-xx Externally Threaded Control Ball Valves PN25 (DN40 TO DN50)

Valve bodies type RA-N with integrated presetting

Dynamic Valve Type RA-DV Pressure Independent Radiator Valve

High Capacity Valve Body, Type RA-G

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

V5822A/5823A,C/V5832A/V5833A,C

V5832A/5833A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

HERZ 7217 V. Integral Fixed Orifice Control Valve HERZ 7217 V. Data sheet 7217 V, Issue Size in mm. STRÖMAX Fig No DN L Lm Rp H SW kv kvs

V5050A,B FLANGED LINEAR VALVE PN16 AND PN25/40

Technical information Thermostatic radiator valves

V5822A / 5823A,C SMALL LINEAR VALVES PN16 FOR MODULATING AND ON/OFF-CONTROL SPECIFICATIONS GENERAL

Floor heating manifold with automatic flow control

Flow-compensated temperature controller AVTQ DN 15

Thermostatic radiator valves with presetting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Flow controller (PN 25) AVQ - return and flow mounting

Two-port seat valves with male thread, PN16

Flow controller (PN 25) AVQ - return and flow mounting

Fan-coil valves Series

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

2-Port and 3-Port Zone Valves PN 16

Ascotherm eco KRP91 Natural convection

RADIATOR VALVES / RADIATOR VALVES WITH PRESETTING

Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

Self-operated Pressure Regulators Universal Pressure Reducing Valve Type 41-23

Series V47 Temperature Actuated Modulating Valves

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

3-port seat valves, external thread, PN16

Valve bodies with pressfit connection and self-sealing tailpiece. Type RA-N for two pipe systems

THERMOSTATIC CONTROL HEADS:

Manual Presetting Valves LENO MSV-B

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

2-Port and 3-Port Zone Valves PN 16

Leakage rate. Valve body. U.S. Registered Trademark EN0B-0308GE51 R1002 Copyright 2002 Honeywell Inc. All rights reserved

Typetested versions With Type 3213 Globe Valve, unbalanced. With Type 3214 Globe Valve, balanced

3-Port Seat Valves with Male Thread, PN 16

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

3-Port Seat Valves with Male Thread, PN 16

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

ML6420A/ML6425A,B. Electric Linear Valve Actuators

2-port and 3-port valves with T-bypass PN 16

2, 3 and 4 - way valves VZL

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Self-operated Temperature Regulators Temperature Regulator Type 1u

ACVATIX MiniCombiValves (MCV)

2-port and 3-port terminal unit valves PN16

three-way mixing valve

Tour b Andersson AB THERMOSTATICALLY CONTROLLED RADIATOR VALVE RVT

V4043/V4044 Motorized Valves

ACVATIX MiniCombiValves (MCV)

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Your Personal Catalog Temperature Controllers All our know-how - is now yours

VZ*19* VZ219E, VZ319E, VZ419E VZ219C, VZ319C, VZ419C

Three-port slipper valves PN10, female-threaded

S10010 / S SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS 10/20 Nm (88/177 lb-in) FOR MODULATING AND FLOATING CONTROL SPECIFICATIONS GENERAL

Self-operated Pressure Regulators Type Universal Excess Pressure Valve

Lockshield valves with Pressfit connection Type RLV with isulation and regulation

dynacon floor heating manifold with automatic flow control

CONA Further components / Accessories

Cooling water Chilled water Low temperature hot water C Water with anti-freeze (max. 50%vol.)

Modulating control valve PN16 with magnetic actuator

Pressure independent combined control and balancing valves with independent EQM characteristics

Static Balancing Valve

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Transcription:

V2000BB BB type TRV Body RADIATOR VALVE WITH BROADBAND CARTRIDGE PRODUCT DATA Angle to EN215 (D) 011 Straight to EN215 (D) Application Thermostatic radiator valve bodies (TRV bodies) are fitted on the supply or return of radiators or heat exchangers. Together with a radiator thermostat, for example the Thera-4, they control the room temperature by regulating the flow of hot water into the radiator or heat exchanger. The temperature of different rooms is controlled individually and energy is saved. TRV bodies of this type have quiet operation and are fitted to the supply or return of radiators on two-pipe systems with medium flow rates. The valve insert can be replaced while the system is running and without draining using the service tool (see Accessories ). TRV bodies of this type are suitable for Honeywell radiator thermostats with M30 x 1.5 connection Certain Honeywell MT4 actuators Honeywell Hometronic HR80 and Roomtronic HR40 actuators Angle to EN215 (F) Horizontal angle Corner angle Straight to EN215 (F) Straight with swanneck AT-Concept AT-Concept valves share the same valve housing design. The valve insert can be replaced by any other AT-Concept valve insert, i.e. BB, KV, UBG, SL, VS, FS, FV and SC. Features For heating systems with medium flow rates Available for installation on the supply or on the return Quiet operation DIN type bodies with dimensions according to EN215, Appendix A, Series D NF type bodies with dimensions according to EN215, Appendix A, Series F AT-Concept valve housing and insert Valve insert can be replaced while system is operating and without draining the system Valve opening spring is not in the water Standard M30 x 1.5 thermostat connection Supplied with black protection cap, imprinted BB for clear identification Horizontal angle (return) Straight (return) Honeywell Subject to change EN0H-2100GE25 R0115

V2000BB - BB TYPE TRV BODY Design The thermostatic radiator valve body consists of: Valve housing PN10, DN10, 15 or 20 with internal thread connection to DIN2999 (ISO7) for threaded, copper or precision steel pipe on inlet (compression ring fittings see Accessories ) external thread connection with union-nut and radiator tailpiece on outlet (Eurocone for DN15) angle to DIN and straight to DIN bodies with dimensions according to EN215, Appendix A, Series D angle to NF and straight to NF bodies with dimensions according to EN215, Appendix A, Series F Valve insert with BB (broadband) type cartridge Protection cap Union-nut and radiator tailpiece Materials Valve housing made of nickel-plated hot-forged brass Valve insert made of brass with EPDM O-rings and soft seals and stainless steel spindle Protection cap made of black plastic Union-nut and tailpiece made of nickel-plated brass Please note: To avoid stone deposit and corrosion the composition of the medium should conform with VDI-Guideline 2035 Additives have to be suitable for EPDM sealings System has to be flushed thoroughly before initial operation with all valves fully open Any complaints or costs resulting from non-compliance with above rules will not be accepted by Honeywell Please contact us if you should have any special requirements or needs Specifications Medium Heating water, water quality to VDI2035 Operating temperature max. 130 C (266 F) Operating pressure PN10 Differential pressure max. 100kPa (1 bar, 14.5 psi) max. 20 kpa (0.2 bar, 2.9 psi) recommended for quiet operation k vs (cvs)-value 0.62 (0.73) Nominal flow 142 kg/h Body-head connection M30 x 1.5 Closing dimension 11.5 mm Stroke 2.5 mm Spec. stroke 0.22 mm/k Identification Black protection cap, BB embossed on top of cap B imprinted 3x on top of valve insert Function Thermostatic radiator valves enable individual control of room temperature and thus save energy. The TRV body is controlled by the radiator thermostat. Air from the room passing over the sensor of the radiator thermostat causes the sensor to expand when the temperature rises. The sensor acts onto the valve spindle and this causes the TRV body to close. When the temperature falls the sensor contracts and the spring-loaded valve spindle is opened. The TRV opens in proportion to the temperature of the sensor. Only the amount of water required to maintain the room temperature set on the radiator thermostat can flow into the radiator. Installation Examples Fig. 1. Angle Fig. 2. Straight Fig. 3. Horizontal angle Fig. 4. Corner angle Fig. 5. Straight with swanneck EN0H-2100GE25 R0115 2 Honeywell Subject to change

Dimensions and Ordering Information Fig. 6. Angle Fig. 7. Straight 52 h h L G l l L H Fig. 8. Horizontal angle Fig. 9. Corner angle Fig. 10. Straight with swanneck Body type DN EN215 certified For the supply Angle to EN215 (D) (Fig. 6) Straight to EN215 (D) (Fig. 7) Angle to EN215 (F) (Fig. 6) Straight to EN215 (F) (Fig.7) Horizontal angle (Fig. 8) Corner angle, radiator connection left (Fig. 9) Corner angle, radiator connection right (Fig. 9) Swanneck (Fig. 10) For the return Horizontal angle (Fig. 8) Straight (Fig. 7) All dimensions in mm unless stated otherwise. Table 1. Dimensions and OS-Nos (OS=Ordering System) k vs(c vs)- value Pipe connection l L h H h 2 OS-No. 10 0.62 (0.73) Rp 3 / 8" 26 52 22 20 V2000EBB10 15 0.62 (0.73) Rp 1 / 2" 29 58 26 20 V2000EBB15 20 0.62 (0.73) Rp 3 / 4" 34 66 29 19 V2000EBB20 10 0.62 (0.73) Rp 3 / 8" 59 85 25 V2000DBB10 15 0.62 (0.73) Rp 1 / 2" 66 95 25 V2000DBB15 20 0.62 (0.73) Rp 3 / 4" 74 106 25 V2000DBB20 10 0.62 (0.73) Rp 3 / 8" 24 49 20 21 V2020EBB10 15 0.62 (0.73) Rp 1 / 2" 26 53 23 22 V2020EBB15 20 0.62 (0.73) Rp 3 / 4" 34 66 29 18 V2020EBB20 10 0.62 (0.73) Rp 3 / 8" 50 75 26 V2020DBB10 15 0.62 (0.73) Rp 1 / 2" 55 82 26 V2020DBB15 20 0.62 (0.73) Rp 3 / 4" 74 106 24 V2020DBB20 10 0.62 (0.73) Rp 3 / 8" 24 50 22 33 V2000ABB10 15 0.62 (0.73) Rp 1 / 2" 26 54 26 35 V2000ABB15 10 0.62 (0.73) Rp 3 / 8" 24 53 26 22 26.5 V2000LBB10 15 0.62 (0.73) Rp 1 / 2" 24 53 26 26 30.5 V2000LBB15 10 0.62 (0.73) Rp 3 / 8" 24 53 26 22 26.5 V2000RBB10 15 0.62 (0.73) Rp 1 / 2" 24 53 26 26 30.5 V2000RBB15 15 0.62 (0.73) Rp 1 / 2" 66 108 25 V2000BBB15 15 0.62 (0.73) Rp 1 / 2" 29 58 26 23 V2000HBB15 15 0.62 (0.73) Rp 1 / 2" 65 95 23 V2000IBB15 Honeywell Subject to change 3 EN0H-2100GE25 R0115

Accessories Pipe Connections Compression fitting for COPPER and STEEL pipe. Consisting of compression nut and compression ring. For valves with internal thread. Valve size Pipe Part number dimension Pcs/ pack 3/8" (DN10) 10 mm FIG3/8CS10 1 3/8" (DN10) 12 mm FIG3/8CS12 1 " (DN15) 10 mm FIGCS10 1 " (DN15) 12 mm FIGCS12 1 " (DN15) 14 mm FIGCS14 1 " (DN15) 15 mm FIGCS15 1 " (DN15) 15 mm FIGCS15-10 10 " (DN15) 16 mm FIGCS16 1 3/4" (DN20) 18 mm FIG3/4CS18 1 3/4" (DN20) 22 mm FIG3/4CS22 1 Support inserts have to be used for copper or soft steel pipe with 1.0 mm wall thickness.max. operating temperature 120 C, max. operating pressure 10 bar. Compression fitting for COPPER and SOFT STEEL pipe. Consisting of compression nut, compression ring and support insert. For valves with internal thread. Valve size Pipe Part number dimension Pcs/ pack 3/8" (DN10) 12 mm FIG3/8CSS12 1 " (DN15) 12 mm FIGCSS12 1 " (DN15) 14 mm FIGCSS14 1 " (DN15) 15 mm FIGCSS15 1 " (DN15) 16 mm FIGCSS16 1 " (DN15) 18 mm FIGCSS18 1 3/4" (DN20) 18 mm FIG3/4CSS18 1 Support inserts have to be used for copper or soft steel pipe with 1.0 mm wall thickness.max. operating temperature 120 C, max. operating pressure 10 bar. Reduction piece 1" pipe > " valve VA6290A260 1 1/4" pipe > " valve VA6290A280 1" pipe > 3/4" valve VA6290A285 1 1/4" pipe > 3/4" valve VA6290A305 Radiator tailpiece with thread up to collar for valves DN10 (3/8") for valves DN15 (") for valves DN20 (3/4") Valve Accessories VA5201A010 VA5201A015 VA5201A020 Extended radiator tailpiece, nickel-plated, to be shortened as required 3/8" x 70 mm (for DN10) VA5204B010 thread approx. 50 mm " x 76 mm (for DN15) VA5204B015 thread approx. 65 mm 3/4" x 70 mm (for DN20) VA5204B020 thread approx. 60 mm Manual handwheel cap Pre-settable, with integrated locking device VA2200D001 Pressure cap for shutting off valves on radiator outlet for valves DN10 (3/8") VA2202A010 for valves DN15 (") VA2202A015 for valves DN20 (3/4") VA2202A020 Sealing ring for pressure cap for valves DN10 (3/8") for valves DN15 (") for valves DN20 (3/4") Service tool to replace valve insert for all sizes VA5090A010 VA5090A015 VA5090A020 VA8200A001 Compression fitting for MULTILAYER pipe. Consisting of compression nut, compression ring and support insert. For valves with internal thread. Valve size Pipe Part number dimension Pcs/ pack " (DN15) 16 mm FIGM16X2 1 Max. operating temperature 90 C, max. operating pressure 10 bar. Replacement valve insert BB type VS1200BB01 EN0H-2100GE25 R0115 4 Honeywell Subject to change

Flow Diagram P-Band 1K 2K 3K open = kvs k v-value 0.22 0.45 0.52 0.62 cv-value 0.26 0.53 0.61 0.73 Design Example Given: Required: Solution: Result: Flow rate 150 kg/h Pressure loss (Δp) with a P-band of 2K The required pressure loss is found at the intersection of the flow line with the line for the chosen valve performance P=2K Δp = 110 mbar = 11 000 Pa Honeywell Subject to change 5 EN0H-2100GE25 R0115

Environmental and Combustion Controls Honeywell GmbH Hardhofweg 74821 MOSBACH GERMANY Phone: +49 (6261) 810 Fax: +49 (6261) 81393 http://ecc.emea.honeywell.com EN0H-2100GE25 R0115 January 2015 2015 Honeywell International Inc. Subject to change without notice Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Z.A. La Pièce 16, 1180 Rolle, Switzerland or its Authorized Representative.