Approved by This document is the property of Network Rail... Date: It shall not be reproduced in whole Phil Collins Head of Asset Management (E&P)

Similar documents
Approved by This document is the property of Network Rail... Date: It shall not be reproduced in whole Phil Collins Head of Asset Management (E&P)

Estimation of electrical losses in Network Rail Electrification Systems

Aaren Healy, 20 September 2017 / 1

Research Brief. Impact of higher 25kV fault currents. T873 - October Background. Aims

SCC Greenhouse Gas Assessment

CMP271 Initial thoughts on Cost Recovery of GB Demand Transmission Charges

Electrification Asset Usage Charge. Presentation to TESG. Matt Skinner, Development Manager 11 th March 2013

Modernising the Great Western railway

Application of claw-back

Addressing ambiguity in how electricity industry legislation applies to secondary networks

SPN High Value Project PO Route. RIIO-ED1 Investment Justification Reinforcement for PO Route Network: SPN

INCREASING electrical network interconnection is

Guideline for Parallel Grid Exit Point Connection 28/10/2010

Research Brief. Simulation and verification of results from 125mph current collection modelling for two pantographs. T841 - January 2011.

Merger of the generator interconnection processes of Valley Electric and the ISO;

Future Funding The sustainability of current transport revenue tools model and report November 2014

Technical Papers supporting SAP 2009

Rapid Response. Lineside Signal Spacing. Railway Group Standard GK/RT0034 Issue Three Date September 1998

UK Power Networks Use of System Charging Methodology

Measuring the Smartness of the Electricity Grid

METRO NORTH TRANSMISSION STUDY ELECTRIC AND MAGNETIC FIELD PROFILES (VILLAGE OF ANMORE)

Co-location Informal Guidance Note. March 2018 Version 1.1

ENERGY STRATEGY FOR YUKON. Net Metering Policy DRAFT FOR CONSULTATION

Deriving Background Concentrations of NOx and NO 2 April 2016 Update

2013 ELR Addendum Note Implications of Siemens / ABP Announcement East Riding of Yorkshire Council

City of Palo Alto (ID # 6416) City Council Staff Report

For personal use only

Appendix 4. HS2 Route Capacity and Reliability. Prepared by Christopher Stokes

In-House paper on Implementation of Telescopic Tariffs in LMV-6 category

Reasonableness Test RT 015 /11 Salisbury Substation 11kV Feeders

PIVE 1 PIVE 2 PIVE 3 PIVE 4 PIVE 5 PIVE 6 PIVE 7 PIVE

Chapter 4. HS2 Route Capacity and Reliability. Prepared by Christopher Stokes

EC Task ForceforSmart Grids: Assessment framework

Compatibility Between Electric Trains and Electrification Systems

The potential for local energy storage in distribution network Summary Report

DG system integration in distribution networks. The transition from passive to active grids

accompanying the up-dated working document on the Review of Regulation (EC) No 278/2009 regarding External Power Supplies

CITY OF LONDON STRATEGIC MULTI-YEAR BUDGET ADDITIONAL INVESTMENTS BUSINESS CASE # 6

University of Alberta

STOR Market Information Report TR27

Galapagos San Cristobal Wind Project. VOLT/VAR Optimization Report. Prepared by the General Secretariat

CMP266 Removal of Demand TNUoS charging as a barrier to future elective Half Hourly settlement

Southern California Edison Rule 21 Storage Charging Interconnection Load Process Guide. Version 1.1

The Project North West Electrification Programme

DRP DER Growth Scenarios Workshop. DER Forecasts for Distribution Planning- Electric Vehicles. May 3, 2017

SUMMARY OF THE IMPACT ASSESSMENT

Final Report. Solar feed in tariff for regional Queensland for

Annual Distribution Pricing Proposal For 1 July 2018 to 30 June 2019 Overview

Final report. Solar feed-in tariff report

GIBRALTAR ERDF OPERATIONAL PROGRAMME POST ADOPTION STATEMENT

EEVC Report to EC DG Enterprise Regarding the Revision of the Frontal and Side Impact Directives January 2000

Smarter Network Storage: Introduction to grid-scale storage and applications, the DNO perspective

How much oil are electric vehicles displacing?

Conduct on-road training for motorcycle riders

SECONDARY FUEL TESTING ARRANGEMENTS

SUPPLEMENTARY EVIDENCE FROM SCOTTISH AND SOUTHERN ENERGY

Utility Operator Model

Expected Energy Not Served (EENS) Study for Vancouver Island Transmission Reinforcement Project (Part I: Reliability Improvements due to VITR)

Residential Load Profiles

ABB POWER SYSTEMS CONSULTING

TRANSMISSION CONNECTION CHARGING METHODOLOGY STATEMENT

Energy Technical Memorandum

The Gambia National Forum on

The Electrification Futures Study: Transportation Electrification

15 Nelson-Marlborough Regional Plan

MYPD3 tariff restructuring plan use-of-system charges. Brochure

Evaluation and modelling of demand and generation at distribution level for Smart grid implementation

RELEASED UNDER THE OFFICIAL INFORMATION ACT 1982

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017

THEFUTURERAILWAY THE INDUSTRY S RAIL TECHNICAL STRATEGY 2012 ENERGY

White Paper. P13008 Net-metering concept for Small Scale Embedded Generation in South Africa. prepared for

ENERGY STRATEGY FOR YUKON. Independent Power Production Policy

Eyre Peninsula electricity supply options investigation

Smart grids in European Union. Andrej GREBENC European Commission "Energy Awarness Seminar Villach

Recharge the Future Interim Findings

SMART DIGITAL GRIDS: AT THE HEART OF THE ENERGY TRANSITION

Emission control at marine terminals

This report contains an analysis of the savings which have been achieved as a result of the installation.

The Energy Complex, non-commodity charges and cost mitigation

Bihar Electricity Regulatory Commission Vidyut Bhawan, J.L.Nehru Marg, Patna

International Aluminium Institute

Utilities (Technical Regulation) (Electricity Transmission Supply Code) Approval 2016 (No 1)*

Electric Power Research Institute, USA 2 ABB, USA

Economic and Social Council

GC108: EU Code: Emergency & Restoration: Black start testing requirement

Deploying Power Flow Control to Improve the Flexibility of Utilities Subject to Rate Freezes and Other Regulatory Restrictions

Decision on Merced Irrigation District Transition Agreement

Header. Reasonableness Test RT 007/11 Balhannah & Uraidla 66 / 33 kv Substations. RT Balhannah and Uraidla - Final Draft Page 1 of 8

Best Practices in Intercity Rail An Infrastructure Manager s Perspective. Nigel Ash Managing Director, Network Rail Consulting TRB January 2014

Introduction to Charging: Which Parties Pay Which Charges?

Low Sulphur Fuel Oils Preliminary Estimated Costs to Canadian Industry based on European Data

committee report General Permitted Development Order SPT response to consultation

Jemena Electricity Networks (Vic) Ltd

GC108: EU Code: Emergency & Restoration: Black start testing requirement

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

Cars and vans CO2 regulations: even ambitious EU standards deliver less than half transport emission reductions needed to meet 2030 climate targets

REPORT ON THE PRICING POLICY FOR GASOLINE AND DIESEL 1st QUARTER 2017 BACKGROUND

In-House Paper on the implementation of Single Part Tariff in Power Distribution

QUESTION / CLARIFICATION QC-ENE-001

POSITION PAPER Version 3.0

Transcription:

Report Estimate of AC losses Electricity Supply Tariff Area Analysis Document Author... Date: Kevin Middleton National Enhancements Project Engineer (E&P) Checked... Date: Simon Polley Principal Policy Specialist Approved by This document is the property of Network Rail.... Date: It shall not be reproduced in whole Phil Collins Head of Asset Management (E&P) Or in part, nor disclosed to a third Party Endorsed by... Date: Richard Stainton Professional Head Electrical Power Copyright 2012 Network Rail 1 of 15

Contents Executive Summary... 3 1. Introduction... 5 1.1 Aim and Purpose... 5 1.2 Scope... 5 1.3 Structure... 5 2. Background... 6 2.1 Network Rail AC Electrification Review NR-EP-EC4T-2010-001... 7 3. Assumptions / Methodology...7 4. ESTA analysis... 8 4.1 Extrapolation of AC Variable (I 2 R) losses... 9 4.2 Extrapolation of AC Fixed Losses... 10 4.3 Estimation of Total AC Losses... 11 5. CP5 - Future electrification and losses... 12 6. Conclusion... 13 7. Recommendations... 13 8. Definitions and abbreviations... 14 9. References... 15 Issue Record Issue Date Author Amendment Summary P01 August 12 KWM Initial draft. P02 August 12 KWM / SNP Updates and incorporation of comments. P03 August12 KWM Added further updates. P04 August 12 KWM / SNP Added executive summary and incorporated comments. P05 August 12 KWM / SNP Updated with minor comments A01 August 12 KWM For issue. A02 August 12 KWM / SNP Updated with NR Planning and Regulation comments. A03 August 12 KWM For issue. Disclaimer 2 of 15

Executive Summary Train operators opting-in to the on-train metering billing system on the Network Rail ac electrification network are charged on the basis of their metered energy consumption plus a percentage uplift to account for electrical losses in the network. Electrical losses consist of a combination of fixed and variable losses. The fixed losses are a constant and occur all the time the network is energised. The variable losses occur when current is flowing, predominantly as a result of trains drawing traction energy. Network Rail completed studies in 2011 which estimated the average value of electrical losses to be 5% for the ac network, this was expressed as an uplift percentage of power used by the train. It was supported by the industry that the value would be set at 5% for the rest of Control Period 4 (CP4) 1. As part of Periodic Review 2013 (PR13), Network Rail reviews the charges it levies on its customers. All final charges are developed in consultation with the industry and are audited and approved by the Office of Rail Regulation (ORR) as part of its periodic review. The PR13 determination will set out the proposed approach for developing the Electric Current for Traction (EC4T) charging framework for implementation from the start of the next Control Period, (CP5) 2. This report will support Network Rail s work to develop the EC4T charges framework for CP5. Since 2011, further studies have been commissioned by Network Rail to further understand the driver(s) of electrical losses on the ac network. It has been established that there are many variables that can contribute to electrical losses which make it difficult to scientifically calculate an absolute figure for losses on the ac network. Although in a commercial environment the appropriate value of losses should be scientifically based on the element of engineering judgement and probability regarding the many variable factors that can occur. As part of the EC4T charging process the ac electrical network is divided into 18 Electricity Supply Tariff Areas, (ESTAs) for billing purposes. Network Rail s duty under its licence is to manage the network in an efficient and economical manner and has provided an indicative electrical range of losses across the entire ac ESTA network outlined in Table 1. 1 This is the regulatory period from 1 April 2009 31 March 2014. 2 This is the regulatory period from 1 April 2014 31 March 2019. 3 of 15

MWh per STK AC ESTAs I 2 R energy loss range Ref: TPD-NST-021 LOSS-REP-0010 Fixed energy loss range Median energy loss Losses mark-up 0 100 D, F 1.2% - 1.4% 4.08% - 4.68% 5.94% 6.32% 100 200 A,B,C,E,I,J,N,S 1.4% - 1.6% 1.99% - 4.72% 5.54% 5.86% 200 300 G,H,Q,V 1.6% - 1.8% 1.88% - 3.30% 4.63% 4.85% 300 400 O,P,R 1.8% - 2.0% 0.89% - 1.83% 3.54% 3.78% 400 500 T 2.0% - 2.2% 0.00% - 1.33% 3.19% 3.29% National Average 4.82% Table 1:- Indicative AC Losses by ESTA The national average of the 5 ranking groups of MWh per STK is 4.82%. This result supports the early 2011 estimate as an uplift percentage of power used by the train. The electrification expansion outlined in DfT s High Level Output Specification (HLOS) for CP5 will add approximately 3,000 single track kilometres to the existing ac network. Putting this plan into context will be equivalent to implementing a new electrified line from London to Edinburgh. Over the last 22 years the ac network s energy consumption has expanded at an annual rate of 1.56%. It is almost certain that the planned electrification expansion programme will increase the average ac electrical loss during CP5. It is estimated that the average level of ac losses will rise by approximately 1% over CP5. With the planned increase of ac electrification during CP5 and in order to provide certainty to train operators who wish to opt-in for on train metering and the ability to manage their EC4T bills, Network Rail will propose to set a single ac national average mark-up of 4.82% for the whole of CP5. Work will continue throughout this year to validate the loss estimation work completed to date using real time metered data. Fixing the average level of electrical losses at 4.82% across the ac network for the duration of CP5 will also demonstrate a level of incentive to Network Rail to make the necessary efficiency improvements to match such a level of increase in demand never seen since the Victorian times. However, we consider that there may be merit in allowing the mark-up to be reopened in the light of significant new information. 4 of 15

1. Introduction Network Rail, the infrastructure operator of the UK railway network, is responsible for managing two different types of electrical traction networks. This report will consider the level of electrical losses on the ac network operating at 25kV on the overhead line system. The dc networks electrical losses will be considered and discussed in further reports and studies, which are due to be published later in 2012. The extrapolation process of the ac electrification losses has been closely aligned with the EC4T billing system, which splits the ac and dc networks into ESTAs. The output and analysis of this report will support Network Rail s EC4T consultation, which will consult on options for developing the EC4T charging framework for CP5, including the proposal for setting the appropriate percentage uplift for ac electrical losses. 1.1 Aim and Purpose This document is intended to support Network Rail s EC4T consultation. It summarises the methodology used and the output enables the extrapolation of the ac losses across the entire network. 1.2 Scope There are currently 20 ESTAs that capture the entire Network Rail network. 18 predominately feed the ac network with 2 feeding the dc network. There is a single ESTA capturing the entire southern dc network with the other dc area encompassing Mersey Rail, these 2 dc networks will not be assessed as part of this report. This report will identify the existing geographic disaggregation of the total ac losses across the network. It will consider the new electrification over CP4 and CP5 and the effects it will have on total losses across the network. 1.3 Structure The structure of the document is summarised below; Section 1 - Introduction - sets out the aims, objectives and the scope of the document. Section 2 - Background - contains references to historical descriptions of the network Section 3 - Assumptions and Methodology - provides a brief outline of the methodology adopted and sets out the key assumptions we have made. Section 4 - ESTA Analysis details the extrapolation process across the present ESTA configuration. Section 5 - CP5 future electrification this section quantifies the scale of the new electrification plans and the effects it will have on electrical losses. Section 6 - Conclusion - outlines the main conclusions of the report. Section 7- Recommendations - outlines the key recommendations with proposals to support the EC4T consultation. 5 of 15

Section 8 - Definition and abbreviations lists the main definitions and abbreviations within the report. Section 9 References lists the main references within the report. 2. Background Train operators opting in to on-train metering in CP4 are charged on the basis of their metered consumption plus a fixed percentage uplift to account for losses in the system across the appropriate ESTA. As a result it is commercially necessary to be able to model the network losses under normal timetable operation to confidently determine the losses uplift that should be applied to the energy metered by the train operators within a particular ESTA. In addition, Network Rail has a duty under its licence to manage the network in an efficient and economical manner and therefore an inherent duty to demonstrate that electrical losses occurring on the traction system are reduced where economically viable; this requires Network Rail to accurately quantify electrical losses. Electrical losses consist of a combination of fixed and variable losses. The fixed losses are constant and occur all the time the network is energised. The variable losses occur when current is flowing predominantly as a result of trains drawing traction energy. Network Rail operates a number of computer models to calculate the energy consumed by trains operating on the ac system. These models are designed to take into account the many variables that influence this energy consumption (e.g. train design, driving style, weather, rail wear, etc) and the consequent variability of losses. Network Rail has used cross industry support to progress further studies on this subject and to this end has commissioned a project, Measurement of Electrification System Losses to carry out a series of on-track measurements for comparison with modelled analysis of a similar network. To validate this modelling, Network Rail contracted with a number of third parties to carry out similar modelling exercises. [1] This report will conclude on and make recommendations regarding: a) The improvement of the estimation of losses on the system; b) the extrapolation of ac losses across each ESTA; and c) the potential economically efficient level of ac losses that could be achieved during CP5. 6 of 15

2.1 Network Rail AC Electrification Review NR-EP-EC4T-2010-001 Network Rail completed studies earlier in 2011 which calculated the value of losses to be 5% for the ac network. This was expressed as an uplift percentage of the power used by the train. The Network Rail report [2] concluded that 5% is considered the best estimate for traction losses based on our understanding of loads and system configurations as applied to a 25 kv ac overhead electric system based on the following estimation. Estimation of Overall Losses Factor Estimated Value Resistive Losses 3% Leakage 1.2% Commercial Up to 1.5% Power Quality Equipment 0.53% Adjustment for BT system Up to 1.7% Total 4% to 6% 3. Assumptions / Methodology We have established that EC4T losses are a combination of fixed and variable losses across the ac network. Variable losses (I 2 R) are a multiple of the network impedance and the square of the load current and have been modelled over a 24-hour period using the 2015 ECML timetable. [4] The ac network s fixed losses have been established using the annual 2011 energy consumption report and extrapolating the fixed loss across each ESTA [3 and 6]. It has also been possible to establish a relationship between the energy consumed (MWh) to the length of the feeding area (STK). This relationship enabled the summation of the variable and fixed losses for each GSP and therefore extrapolated across each of the 18 ac ESTAs. In estimating the extrapolation of the total ac losses across the 18 ESTAs the following key assumptions have been made:- 1. The train simulation modelling package (Vision / Oslo) has been validated during Stage 1 of the project [1]. Due to the variable factors influencing losses [5] it has always been difficult to align real time data with modelled data and the report has assumed a10% uplift on modelled results to actual results. (i.e supplied energy, gradients, etc). This will be further validated throughout this year using real time metered data from ESTA H. 2. No stabling loads in depots or sidings have been included in our modelling assumptions. 7 of 15

3. Using the Balancing Settlement Metering Code we have assumed metering accuracy at the Network Rail GSPs will all operate to Code of Practice 1, (CoP). We have assumed the metering accuracy of +/- 1% will have a net effect on losses. 4. All on-train metering data will be within the metering tolerances specified in EN 50463 3. We have assumed the ac metering accuracy of +/- 1.5% will have a net effect on losses. 5. The regenerative braking aspect with our simulation model has assumed a zero net impact on electrical losses. This will be discussed further in the consultation. 6. We have not accounted for any error with the On Train Metering (OTM) system errors. 7. We have assumed all energy consumed with our models is related to traction power. 8. All Booster transformers in the calculation are rated at 290kVA 9. All Autotransformers in the calculation are rated at 15MVA. 10. In all areas we have assumed two insulators are housed on every support structure with a span length being every 40m. It is difficult to quantify the amount of insulators across the network due to the different overhead line supports and feeding arrangements but we believe this assumption may be a conservative estimate. 11. The ratio of installed polymeric against ceramic insulators is assumed to be 50%. In order to quantify this assumption the local Route Asset Managers (E&P) have been requested to confirm / advise on this ratio. 12. UK climate is changeable over the 4 seasons. The UK receives a considerable amount of rainfall and precipitation from the fog and snow. We have demonstrated via our insulator studies the effects that wet conditions have over leakage losses. Using the data from various sources we have calculated a wet to dry annual ratio of 37% (i.e. in a 24-hour period, the insulators will be wet for 8.88 hours). 4. ESTA analysis Currently within Network Rail s network there are approximately 123 GSPs; approximately 79 are related to the ac network. The GSP is the location of the transformation of transmission voltages that are required for the power to feed the ac traction network. These GSP locations also house the settlement metering devices that support the EC4T billing process Several GSPs are then grouped into 18 ESTAs for billing purposes. We have established that electrification traction system losses are made up of a combination of fixed and variable losses across the network. As part of the metered billing process, the energy consumed by the train operators is uplifted 3 Euro norm 50463 sets out the European standards for on-train metering equipment. 8 of 15

by a percentage to account for the electrification traction system losses. Each ESTA is designated with an alphabetic code where each GSPs traction load feeds a section of railway and has a distance measured in STK, therefore grouping the relevant GSPs to make up the ESTAs. Of the 18 ESTAs, there are 3 which incorporate a billing system for dual voltages (i.e. ac and dc networks). In these 3 ESTAs, identified as ESTA, P, R & T, the proportion of ac load that feeds the dc network is excluded from this analysis. The boundaries of the 18 ESTAs are split by an isolated / earthed section known as a neutral section [8]. The method in calculating the variable and fixed losses on the ac network are illustrated in the following sections 5.1 and 5.2 with the estimated extrapolation of the total ac loss across each ESTA identified in Table 1 in section 5.3. 4.1 Extrapolation of AC Variable (I 2 R) losses Traction modelling has been carried out to determine the level of resistive losses (I 2 R) and energy consumption based on the IEP 2015 timetable capacity over a 24-hour weekday period for each electrically fed section (GSP) that forms the East Coast Main Line (ECML) including the branch lines on the electrical network. As expected, the percentage of resistive losses varies across all of the modelled ECML and branch line GSPs. In order to establish a load / resistive loss relationship the data was re-formatted based on the present ESTA configurations. This presented a relationship between the cumulative energy supplied in the modelled ESTA along with the percentage of resistive loss. Using the modelled data, the relevant ESTAs were then ranked in terms of ascending percentage resistive loss. It should be noted that the ranking aligned with the 2011 energy usage MWh per STK. This clearly demonstrated that the resistive losses predominately depend on the train service and the load demand [4]. This relationship is a result of the historical pattern of incremental reinforcement matching the gradual increase in load demand and maintaining a limited level of headroom. Initially, reinforcement to network capacity that was not matched by a similar increase in load demand would result in reduced losses, this reduction then being eroded as load demand matched the new network capacity. The total length of the modelled ECML and branch lines is estimated at 2,220 STK. It captures 6 ESTAs and the area represents 29% of the total 25kV ac electrified network and includes a mixture of rail return, classic and autotransformer networks. The ECML modelled area used over 12% of the total energy usage of the 25kV ac UK railway network during 2011; it therefore provided a sound basis for extrapolating the resistive losses results across the entire ac network as outlined in the column I 2 R energy Loss range within Table 1. 9 of 15

4.2 Extrapolation of AC Fixed Losses Fixed losses on the ac network arise from the current that flows on the network irrespective of the load demand due to primarily transformer magnetising and insulator leakage currents plus any power quality equipment connected to the Network Rail infrastructure (i.e. harmonic dampers, etc). It is difficult to model and simulate such fixed losses therefore various studies were commissioned in order to calculate each component s electrical loss either via testing or using manufacturer data sheets [6]. To gather the data for each of the components electrical losses, a spread sheet for each GSP was assembled, supported by the latest infrastructure operational documentation (i.e. Network Rail - Route isolation diagrams). This enabled the correct quantity of components to be assembled per GSP (i.e. quantity of insulators, transformers, harmonic dampers etc). Using the 2011 electrical energy consumption for each GSP [3] it has been possible to extrapolate an average daily load (kwh) for each Network Rail GSP. By inserting the 2011 average daily loads into the spreadsheet, the estimated 24 hour fixed no load losses for each GSP can be estimated. The average fixed no load loss result for each GSP is then grouped into the respective ac ESTAs and an average fixed no load loss per ac ESTA is estimated The range of results are then aligned and with the 2011 energy usage MWh per STK outlined in the column Fixed energy loss range within Table 1. 10 of 15

4.3 Estimation of Total AC Losses Due to the many variables that can contribute to electrical losses it is still not possible to scientifically calculate an absolute figure for an ac traction network loss. Although in a commercial environment the appropriate value of losses should be scientifically based on the element of engineering judgement and probability regarding the many variable factors that occur [5]. Network Rail s duty under its licence to manage the network in an efficient and economical manner has provided an indicative electrical range of losses across the entire ac ESTA network outlined in Table 1. The table has been produced by summating the range of variable (I 2 R) loss and fixed loss with the final column providing a train losses mark-up value for input into the metered billing process. It should be noted that averaging over the five ranges of MWh per STK results in a national average losses mark-up of 4.82%, which is broadly consistent with the early 2011 estimated ac losses mark-up value. MWh per STK AC ESTAs I 2 R energy loss range Fixed energy loss range Median energy loss Losses mark-up 0 100 D, F 1.2% - 1.4% 4.08% - 4.68% 5.94% 6.32% 100 200 A,B,C,E,I,J,N,S 1.4% - 1.6% 1.99% - 4.72% 5.54% 5.86% 200 300 G,H,Q,V 1.6% - 1.8% 1.88% - 3.30% 4.63% 4.85% 300 400 O,P,R 1.8% - 2.0% 0.89% - 1.83% 3.54% 3.78% 400 500 T 2.0% - 2.2% 0.00% - 1.33% 3.19% 3.29% National Average 4.82% Table 1:- Indicative AC Losses by ESTA 11 of 15

5. CP5 - Future electrification and losses Under the current electrification enhancement works in CP4 and the proposed CP5 High level Output Specification (HLOS), the electrification network will undergo the greatest expansion of the electric network since the Victorian times. The expansion programme will inevitably increase variable loss and fixed loss on the network. The ac electrification programmes recently announced will add approximately over 3,000 STK of electrified route(s) outlined as follows:- Great Western Main Line Electrification - > 1000 STK additional electrified route(s). Crossrail - > 250 STK additional electrified route(s). Northern Hub Electrification - > 500 STK additional electrified route(s). CP5 - HLOS - > 1000 STK additional electrified route(s). Edinburgh & Glasgow Improvement Program > 300 STK additional electrified route(s). The integration of the above electrification expansion programme into the current ESTA configuration network is still at the preliminary design stages. The annual energy usage illustrated an average annual ac network increase of 1.56% over the past 22 years [3]. It is therefore certain that the planned electrification expansion will maintain this upward trend. Putting the CP5 expansion programme into context, it is equivalent to implementing a new electrified line from London to Edinburgh. At this stage, the increase on the ac network losses due to an increased load demand and further electrification is difficult to quantify without the integration of the ESTA configuration network being complete. Although from the losses work completed to date in Section 5.3, a conservative estimate of the ac network s average losses increasing from 5% to 6% throughout CP5 would be a valid assumption. 12 of 15

6. Conclusion The following can be concluded from this report:- 1. The disaggregation of losses per ESTA outlined in Section 4.3 provides a very useful picture / benchmark on how the losses vary across the ac network with load. 2. The changes in the ratio of variable losses against fixed losses provides Network Rail with useful information for policy to be reviewed and set to ensure the infrastructure has the minimum set of fixed loss [7]. 3. Integrating the outputs of Table 1, with section 5.3, into the current metered billing systems may not benefit train operators. This is because, as the report has highlighted, the ESTA boundaries are highly likely to change during CP5; these changes may be significant as illustrated in Section 5. 7. Recommendations Recommendations from this report are as follows:- 1. The work undertaken to refine the ac network losses estimates are based on models, testing, component manufacturing data sheets and assumptions. Therefore parts of the analysis may be subjective but Network Rail has used an element of engineering judgement and probability in order to conclude its findings. It is recommended that validation work is planned later in 2012 using real-time metered data from ESTA H on the ac network. 2. With the planned increase of ac electrification during CP5 and in order to provide certainty to train operators who wish to opt-in for on-train metering and the ability to manage their EC4T bills, we are proposing to set a single ac national average mark-up of 4.82% for the whole of CP5. Given that the forecast increase in services will naturally increase the level of loss and NR believe that maintaining a constant mark up during CP5 demonstrates an increase in the efficient management of losses matching load growth. However, we consider that there may also be merit in allowing a reopener within CP5 should significant further information come to light. 13 of 15

8. Definitions and abbreviations The following definitions and abbreviations are used within this report. ac CoP CP dc DfT EC4T ECML ESTA GSP HLOS MWh NR OTM ORR STK Alternative current Code of practice Control period Direct current Department for transport Electric current for traction East coast main line Electricity supply tariff area Grid supply point High level output specification Mega watt hours Network Rail On-train metering Office of rail regulation Single track kilometres 14 of 15

9. References No Title Author Ref Date 1 Summary Stage 1 Measurement of Electrification System Losses ac network. Simon Polley TPD-NST-021- LOSS- REP-0005 2011 2 Estimation of Electrical Losses on 25kV ac electrification systems Robert Wilson NR-EP-EC4T-2011-001 2011 3 Traction Related Energy Usage - 2011 Mark Donovan TPD-CFG-006-ECNK- 0001 4 ECML 24 Hour Resistive Losses Phillippe Belvir TPD-NST-021-LOSS- REP-0006 2012 2012 5 Factors Causing Variability of EC4T Load and Impact on Losses Simon Polley TPD-DGN-LOSS-REP- 0007 2012 6 Fixed No Load Loss ESTA analysis Kevin Middleton TPD-DGN-021-LOSS- REP-0008 2012 7 Review of AC Traction Energy Efficiency Proposals Simon Polley TPD-CFG-006-ECNK- REP-0002 2012 8 Network Rail Electricity Supply Tariff Area Alan Bullock Version 2.3 2011 15 of 15