A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN

Similar documents
A97MV PRODUCT SPECIFICATIONS 97% MODULATING VARIABLE SPEED GAS FURNACE CONTROLS VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS

95G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

93% Gas Furnaces Single Stage

92G1 PRODUCT SPECIFICATIONS SINGLE STAGE GAS FURNACE CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER CABINET DESIGN AIR DELIVERY SYSTEM CONTROLS VENTING

97% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

95G1-E. Aluminized steel primary heat exchanger with crimped non-welded construction AL 29-4C Stainless steel secondary heat exchanger

95% Gas Furnaces. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 95G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

95% Gas Furnaces A95-1E. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits CONFIGURATIONS

96% Modulating Variable Speed Gas Furnace. Features and Benefits CONFIGURATIONS

93% Single Stage. Gas Furnace. Features and Benefits CONFIGURATIONS

A962E PRODUCT SPECIFICATIONS TWO STAGE HIGH EFFICIENCY CONSTANT TORQUE GAS FURNACE CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN

A951E PRODUCT SPECIFICATIONS CONTROLS VENTING INSTALLATION FEATURES CONFIGURATIONS WARRANTY HEAT EXCHANGER DESIGN BURNER CABINET DESIGN

96G1E PRODUCT SPECIFICATIONS SINGLE STAGE CONSTANT TORQUE MOTOR VENTING INSTALLATION FEATURES WARRANTY CONFIGURATIONS HEAT EXCHANGER DESIGN BURNER

80% Gas Furnaces Single Stage - High Efficiency (Constant Torque) Motor

80% Gas Furnace. Single Stage - High Efficiency (Constant Torque) Motor. Features and Benefits 80G1-E CONFIGURATIONS HEAT EXCHANGER DESIGN BURNERS

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

A95-2V. 95% Gas Furnaces Two-Stage Variable Speed HEAT EXCHANGER DESIGN CONFIGURATIONS

Upflow, Upflow / Horizontal, Counterflow / Horizontal

Upflow, Upflow / Horizontal, Counterflow

FG7T (A and K Series)

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.

13 SEER Light Commercial 3 Phase

Easily removable slide-out blower design PSC multi-speed permanently lubricated blower motor for low maintenance and optimum efficiency

FG7T (A and K Series)

GMS9/GCS9 SERIES 93% AFUE

Available in Upflow/Horizontal and Counterflow/Horizontal models

GUH 95 Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

FG7T (E and N Series)

KG7T (E and N Series)

KG7T (C and L Series)

KG7T (C and L Series)

FG7S (C and L Series)

L83 PRODUCT SPECIFICATIONS 83% OIL FURNACE VENTING WARRANTY GENISYS ADVANCED BURNER CONTROL CONFIGURATIONS HEAT EXCHANGER CABINET BLOWER BURNER

Product Data. that this product meets the S 95% AFUE S Two -stage operation

KG7S (A and K Series)

Multi-Position, Multi-Speed Gas Furnaces

TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

PRODUCT SPECIFICATIONS GMS8/GDS8/GHS8 SERIES 80% AFUE MULTI-POSITION, SINGLE-STAGE/MULTI-SPEED GAS FURNACE

UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS)

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

VG7S (D and M Series) High Efficiency, Single Stage Condensing Upflow/Horizontal and Downflow Gas Furnace Models 95.0 AFUE 38, ,000 Btuh Input

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

4SHP13LB PRODUCT SPECIFICATIONS 13 SEER SPLIT SYSTEM HEAT PUMP COIL DESIGN ACCESSORIES. COMPRESSOR Low ambient kit Crank Case Heater Freezestat

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

83% Oil Furnace. Features. Configurations. Cabinet. Blower. Burner

G8MVL. Product Specifications

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

Cooling Capacity CFM in. w.c. (125 Pa)

AF90. AF90 Gas Furnace High Efficiency. Features

WFSR. Product Specifications 95.5 AFUE GAS FURNACE MULTIPOISE DESIGN UPFLOW/DOWNFLOW/HORIZONTAL (NATURAL GAS) Heat Exchangers Warranty

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama 58HDX COMFORT 95 DIRECT OR NON---DIRECT VENT CONDENSING GAS FURNACE

Rheem Classic Plus Series Downflow Gas Furnace

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

GMS8/GDS8/GHS8. Single-Stage, Multi-Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

Ruud Ultra Series Communicating Two-Stage Variable Speed Downflow Gas Furnace

WFEL. Product Specifications. 80% AFUE GAS FURNACE Multipoise Design

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

VMS8/VDS8. Single-Stage, Single Speed, Multi-Position Gas Furnace 80% AFUE. Heating Input : 40, ,000 BTU/h

4SHP14LE. Product Specifications. 14 SEER Split System Heat Pump COMPONENTS COMPRESSOR DESIGN COIL CABINET ACCESSORIES

GMH8/GDH8. Two-Stage Convertible Multi-Speed Gas Furnaces 80% AFUE

Rheem Classic Series Downflow Gas Furnace

4SHP13LE Product Specifications

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

Rheem Classic Series Two-Stage Upflow/Horizontal Gas Furnaces

Rheem Classic Plus Series Upflow/Horizontal Ultra Low NOx Gas Furnace

Ruud Achiever Plus Series Upflow/Horizontal Gas Furnace

N9MPD Product Specifications

TSTAT0101SC Recommended (sold separately)

Rheem Value Series Upflow/Horizontal Gas Furnace

Table of Contents GF801U Series

MGE4 FEATURES REFRIGERANT SYSTEM HEAT EXCHANGER CABINET BLOWER

Cooling Capacity CFM in. w.c. (125 Pa)

DM80SS / DD80SS. Single-Stage, Multi-Speed Gas Furnaces 80% AFUE Heating Input: 40, ,000 BTU/h

MF Product Specifications

AMS8 / ADSS8. Single-Stage Multi-Speed Gas Furnaces 80% AFUE. Heating Input: 40, ,000 BTU/h

N9MSB. PS 92 Product Specifications. 92.1% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL /2/17

Rheem Prestige Series Communicating Two-Stage Variable Speed Upflow/Horizontal Gas Furnace

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

REFRIGERANT SYSTEM R410A Refrigerant High efficiency compressor Copper tubing with enhanced fin coils

4SHP14LB PRODUCT SPECIFICATIONS 14 SEER SPLIT SYSTEM HEAT PUMP DESIGN COIL ACCESSORIES COMPRESSOR WARRANTY CABINET COMPONENTS

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)

BCS2V PRODUCT SPECIFICATIONS AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

Rheem Classic Plus Series Upflow/Horizontal Gas Furnace

Rheem Classic Series Upflow/Horizontal Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

OLR Product Specifications

GMSS92 / GCSS92 Single-Stage Multi-Speed Gas Furnace

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity Dimensions H x W x D CFM range Inches in. w.c. (125 Pa)

Rheem Classic Series Upflow/Horizontal Gas Furnace

DD80HS. Two-Stage, Convertible Multi-Speed Gas Furnace 80% AFUE. Heating Input: 40, ,000 BTU/h

Transcription:

A802V PRODUCT SPECIFICATIONS 2-STAGE VARIABLE SPEED GAS FURNACE FORM NO. A802V-100 (04/2016) VENTING Rotatable draft inducer for venting flexibility INSTALLATION FEATURES Left and right utility connections Removable floor base for bottom return air "L" designated models comply with California's South Coast Air Quality Management district NOx requirements Zero step horizontal conversion WARRANTY 10 year limited parts warranty / lifetime heat exchanger warranty available. See limited warranty document for details. Note: Not for sale in Canada CONFIGURATIONS Upflow / Horizontal Downflow HEAT EXCHANGER DESIGN Aluminized crimped no-weld clam shell heat exchanger CABINET DESIGN Compact 33 height Standardized widths for easy coil fit AIR DELIVERY SYSTEM ECM Variable speed blower motor Easily removable slide out blower design CONTROLS Communicating control enabled Two stage gas valve Thermostat flexibility:works with the Comfort Sync T-Stat or a conventional 24V T-Stat Self diagnostics saves last 5 fault codes regardless of power interruption Page 1

MODEL NUMBER GUIDE A 80 U S 2 V 110 C 20 L - 01 A FLAGSHIP AFUE 80 = 80% EFFICENCY CONFIGURATION U = UPFLOW/HORIZONTAL D = DOWNFLOW S = COMMUNICATING STAGES 2 = TWO STAGE V = VARIABLE SPEED MAJOR REVISION CODE NUMERIC CODE OPTION CODE L = LOW NOX NOM. CFM X 100 8 = 3 TON ADD ON COOLING 12 = 3 TON ADD ON COOLING 16 = 4 TON ADD ON COOLING 20 = 5 TON ADD ON COOLING CABINET WIDTH B = 17.5 WIDTH C = 21.0 WIDTH D = 24.5 WIDTH BTUH WIDTH HEATING INPUT X 1000 PHYSICAL AND ELECTRICAL DATA Model Input (Btuh) Output* (Btuh) AFUE (ICS) Nominal Capacity Gas Inlet (in.) Volts/ Hz/ Phase Max. Time Delay Breaker or Fuse Nominal F.L.A. Trans. (V.A.) Approx. Shipping Weight (lbs.) A80US2V070A12 66,000 52,000 80.0% 3 tons 1/2 120-60-1 15 7.7 40 128 A80US2V090B12 88,000 70,000 80.0% 3 tons 1/2 120-60-1 15 7.7 40 143 UPFLOW/HORIZONTAL A80US2V090B16 88,000 70,000 80.0% 4 tons 1/2 120-60-1 20 12.8 40 154 A80US2V090C20 88,000 70,000 80.0% 5 tons 1/2 120-60-1 20 12.8 40 173 A80US2V110C20 110,000 87,000 80.0% 5 tons 1/2 120-60-1 20 12.8 40 181 A80US2V135D20 132,000 105,000 80.0% 5 tons 1/2 120-60-1 20 12.8 40 199 A80US2V070A12L 66,000 52,000 80.0% 3 tons 1/2 120-60-1 15 7.7 40 128 A80US2V090B16L 88,000 70,000 80.0% 4 tons 1/2 120-60-1 20 12.8 40 154 A80US2V110C20L 110,000 87,000 80.0% 5 tons 1/2 120-60-1 20 12.8 40 181 DOWNFLOW A80DS2V070A12 66,000 52,000 80.0% 3 tons 1/2 120-60-1 15 7.7 40 130 A80DS2V090B16 88,000 69,000 80.0% 4 tons 1/2 120-60-1 20 12.8 40 153 A80DS2V110C20 110,000 87,000 80.0% 5 tons 1/2 120-60-1 20 12.8 40 173 Note: For vent length and clearances to combustibles, please reference installation instructions. * Outputs shown are Fire, 100% rate, Fire is 67% of shown output. Page 2

BLOWER PERFORMANCE DATA Heating Model Motor (hp) Blower Fire CFM @ 0" - 0.5" w.c. Fire CFM @ Adjust- 0" - 0.5" ment w.c. Stage CFM @ 0" - 0.8" w.c. (Default) +24% 1073 +24% 1178 +10% 748 801 864 970 A80US2V070A12(L) 1/2 HP 10 x 8 25-55 +18% 1021 +18% 1121 1st Default 680 728 785 882 +12% 969 +12% 1064 Stage +6% 917 +6% 1007-10% 612 655 707 974 40-70 Default 865 Default 950 +10% 1007 1095 1210 1348-6% 813-6% 893 2nd Default 915 995 1100 1225-12% 761-12% 836 Stage -18% 709-18% 779-10% 824 896 990 1103 +24% 1302 +24% 1426 +10% 556 699 787 919 A80US2V090B12 1/2 HP 10 x 9 25-55 +18% 1239 +18% 1357 1st Default 505 635 715 835 +12% 1176 +12% 1288 Stage +6% 1113 +6% 1219-10% 455 572 644 752 40-70 Default 1050 Default 1150 +10% 930 1100 1210 1320-6% 987-6% 1081 2nd Default 845 1000 1100 1200-12% 924-12% 1012 Stage -18% 861-18% 943-10% 761 900 990 1080 +24% 1353 +24% 1488 +10% 743 935 1073 1238 UPFLOW/HORIZONATL A80US2V090B16(L) 1 HP 11-1/2 x 9 25-55 +18% 1287 +18% 1416 1st +12% 1222 +12% 1344 Stage Default 675 850 975 1125 +6% 1156 +6% 1272-10% 608 765 878 1013 40-70 Default 1091 Default 1200 +10% 1045 1320 1540 1760-6% 1026-6% 1128 2nd -12% 960-12% 1056 Stage Default 950 1200 1400 1600-18% 895-18% 984-10% 855 1080 1260 1440 +24% 1353 +24% 1488 +10% 897 1045 1177 1353 A80US2V090C20 1 HP 11-1/2 x 10 25-55 +18% 1287 +18% 1416 1st Default 815 950 1070 1230 +12% 1222 +12% 1344 Stage +6% 1156 +6% 1272-10% 734 855 963 1107 Default 1091 Default 1200 +10% 1276 1491 1683 1931-6% 1026-6% 1128 2nd Default 1160 1355 1530 1755-12% 960-12% 1056 Stage -18% 895-18% 984-10% 1044 1220 1377 1580 +24% 1693 +24% 1860 +10% 1155 1210 1342 1419 A80US2V110C20(L) 1 HP 11-1/2 x 10 25-55 +18% 1611 +18% 1770 1st Default 1050 1100 1220 1290 +12% 1529 +12% 1680 Stage +6% 1447 +6% 1590-10% 945 990 1098 1161 Default 1365 Default 1500 +10% 1650 1735 1914 2024-6% 1283-6% 1410 2nd Default 1500 1575 1840 1840-12% 1201-12% 1320 Stage -18% 1119-18% 1230-10% 1350 1418 1566 1656 +24% 1872 +24% 2058 +10% 1062 1139 1309 1419 A80US2V135D20 1 HP 11-1/2 x 11 25-55 +18% 1782 +18% 1959 1st Default 965 1035 1190 1290 +12% 1691 +12% 1859 Stage +6% 1601 +6% 1760-10% 869 932 1071 1161 40-70 Default 1510 Default 1660 +10% 1513 1623 1870 2024-6% 1419-6% 1560 2nd Default 1375 1475 1700 1840-12% 1329-12% 1461 Stage -18% 1238-18% 1361-10% 1238 1328 1530 1656 Page 3

BLOWER PERFORMANCE DATA Model Motor (hp) Blower Fire Heating CFM @ 0" - 0.5" w.c. Fire CFM @ Adjust- 0" - 0.5" ment w.c. Stage CFM @ 0" - 0.8" w.c. (Default) +24% 1042 +24% 1147 +10% 693 755 855 986 A80DS2V070A12 1/2 HP 10 x 8 25-55 +18% 991 +18% 1092 1st Stage Default 630 686 777 896 +12% 941 +12% 1036 +6% 980 +6% 981-10% 567 617 699 806 Default 840 Default 925 +10% 990 1078 1221 1408-6% 790-6% 870 2nd Stage Default 900 980 1110 1280-12% 739-12% 814-18% 689-18% 759-10% 810 882 999 1152 DOWNFLOW A80DS2V090B16 1 HP 11-1/2 x 9 25-55 +24% 1353 +24% 1488 +10% 770 935 1073 1238 +18% 1287 +18% 1416 1st Stage Default 700 850 975 1125 +12% 1222 +12% 1344 +6% 1156 +6% 1272-10% 630 765 878 1013 Default 1091 Default 1200 +10% 1100 1320 1540 1760-6% 1026-6% 1128 2nd Stage Default 1000 1200 1400 1600-12% 960-12% 1056-18% 895-18% 984-10% 900 1080 1260 1440 +24% 1581 +24% 1742 +10% 985 1139 1293 1331 A80DS2V110C20 1 HP 11-1/2 x10 25-55 +18% 1505 +18% 1658 1st Stage Default 895 1035 1175 1210 +12% 1428 +12% 1574 +6% 1352 +6% 1489-10% 806 932 1058 1089 Default 1275 Default 1405 +10% 1403 1625 1843 1898-6% 1199-6% 1321 2nd Stage Default 1275 1475 1675 1725-12% 1122-12% 1236-18% 1046-18% 1152-10% 1148 1328 1508 1553 Page 4

DIMENSIONS (IN.) Model A B C D Front A80US2V070A12(L) 14-1/2 13-3/8 13 4-3/4 UPFLOW/HORIZONTAL DOWNFLOW A80US2V090B12 17-1/2 16-3/8 16 6-1/4 A80US2V090B16(L) 17-1/2 16-3/8 16 6-1/4 A80US2V090C20 21 19-7/8 19-1/2 8 A80US2V110C20(L) 21 19-7/8 19-1/2 8 A80US2V135D20 24-1/2 23-3/8 23 11-1/8 A80DS2V070A12 14-1/2 13-3/8 13 4-3/4 A80DS2V090B16 17-1/2 16-3/8 16 6-1/4 A80DS2V110C20 21 19-7/8 19-1/2 8 Top Top Upflow / Horizontal Downflow Right Side Right Side Bottom Bottom Page 5

ACCESSORY LIST CATALOG NUMBER DESCRIPTION External Filter Rack kits 1.841018 1 pack (16 x 25) 1.841039 10 pack (16 x 25) Natural to LP kits 68W76 77W08 for -1 models for -2 models LP to Natural kits 73W32 77W10 for -1 models for -2 models Return Air Base 68W61 68W62 68W63 Return Air Base 14.5 Inch, A Width Return Air Base 17.5 Inch, B Width Return Air Base 21.0 Inch, C Width Night Service Kit 89W54 Two-Stage Horizontal Suspension Kit 51W10 80% & 90% Kit Combustible Floor Base 11M59 11M60 11M61 14.5 Inch, A Width 17.5 Inch, B Width 21.0 Inch, C Width Note: For vent length and clearances to combustibles, please reference installation instructions. All specifications and illustrations subject to change without notice and without incurring obligations. 1-800-448-5872 FORM NO. A802V-100 (04/2016) 2016 Allied Air Enterprises LLC, a Lennox International Inc. Company Printed in the U.S.A. Page 6