PE202. Low Flow Magmeter Instructions. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

Similar documents
User s Guide FMG80A SERIES. Low-Flow Magmeter. Shop online at omega.com SM. For latest product manuals:

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

S-Series. Low Flow Meter Instructions SPX SPT. Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

WMP-Series PLASTIC-BODIED MAGMETER INSTRUCTIONS 9001:2008 ISO CERTIFIED COMPANY WMP-SERIES PLASTIC-BODIED MAGMETER INSTRUCTIONS. 3 inch.

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

AG2000 IRRIGATION MAGMETER INSTRUCTIONS

WMX-series MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

Positive Displacement Flowmeters

TX800-Series FLOW SENSOR INSTRUCTIONS. TX81x TX82x 9 001:2008 ISO CERTIFIED COMPANY TX800-SERIES FLOW SENSOR INSTRUCTIONS

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

EX80-Series ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONS EX81 EX82 EX :2008 ISO CERTIFIED COMPANY

Instructions EM 101 Low Flow Electromagnetic Flow Meters

WMP-Series. Plastic-Bodied Magmeter Instructions ISO. 2 inch. Precision Flow Measurement. An ONICON Brand 9001:2008 PROUDLY MADE IN THE USA.

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series. Insertion Paddlewheel Flow Sensor Instructions PROUDLY MADE IN THE USA

MFM220 & MFM220DC Plastic-Bodied Magmeter

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

EX100/200-Series INSERTION MAGNETIC FLOW METER INSTRUCTIONS EX110 EX210 EX150 EX :2008 ISO CERTIFIED COMPANY

EX100/200 Series. Insertion Magnetic Flow Meter Instructions. EX11x EX21x. EX15x EX25x PROUDLY MADE IN THE USA

imag 4700 SERIES FLANGED MAGMETER

EX800-Series. Electromagnetic Flow Sensor Instructions PROUDLY MADE IN THE USA

AG2000 Irrigation Magmeter

SIGNET 7002 Vortex Flow Sensor ENGLISH

SERIES FLMG MUNICIPAL/INDUSTRIAL MAGMETER INSTRUCTIONS

WMX-SERIES Flanged Magmeter

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

8000 Series Liquid Flow Meter

Hydro-Flow Model 2300 Installation and Operation Guide B

ISTEC MAGNETIC METERS

8000 Series Liquid Flow Meters

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

Signet 2551 Magmeter Flow Sensor

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

FLOWX3 F3.60M.S Insertion Magmeter

PMG MAGNETIC FLOWMETER

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Hydro-Flow Model 3100

MFM300 Plastic-Bodied Magmeter

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

Insertion magnetic inductive flowmeter

TX100/200-SERIES INSERTION TURBINE INSTRUCTIONS TX101/201 TX115/215 ISO 9001:2008 CERTIFIED COMPANY

TX101/201 Insertion Turbine Instructions

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

TX101/201 Insertion Turbine Instructions

MULTI-JET WATER METERS

Hydro-Flow Model 2200 Installation and Operation Guide B

EZ-View. Flow Meters ISO CERTIFIED 9001

Iron Gate Air Pump System Manual

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Paddle-wheel flow controller for On/Off control

OEM Pressure Transmitters

Paddle-wheel flow controller for On/Off control

Signet 2536 Rotor-X Paddlewheel Flow Sensors

SPIN KLIN GALAXY. Service & Maintenance Manual

MODEL 106F TEFLON LIQUID FLOW SENSOR

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Appendix. Clearance. Skewed profiles. Application Schematics

Information Sheet Polyethylene Tank Assemblies

Vortex Eggs Delta Flowmeter

Mur-lok. Mur-lok Polypropylene Quick-Connect Fittings & Valves. Check Valves. Fixed NPTF 90 Elbows. Check Valve Elbow. Swivel NPTF 90 Elbows

FT430/440/450 RATE/TOTAL INDICATOR INSTRUCTIONS

Octave Water Meter Installation Manual

LM-200 MECHANICAL LUBE METER Owner s Manual

Electromagnetic Flowmeters. Product Overview.

CONTROLLERS & SPECIAL VALVES

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

2100 Turbine Flow Sensor

M SERIES Multi-Jet Cold Water Meter

TX115/215 Hot-tap Insertion Turbine Instructions

INSTRUMENTATION & CONTROL

INSERTION flowmeter with paddle wheel, ELEMENT design

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

ENC 150 REFERENCE MANUAL ACU-RITE

VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR

RESISTIVITY MONITOR/CONTROLLERS

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Signet 7000/7001 Vortex Flow Sensors * *

OMP POSITIVE DISPLACEMENT FLOWMETERS

SERIES TBS INSERTION TURBINE TBS-0XX TBS-1XX

OMP Positive Displacement Flowmeters

Signet 2552 Metal Magmeter

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

DEMA Pro-Fill I Sink Dispenser

Industrial Pressure Transmitters

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Pressure transmitters for heavy duty applications Type MBS 3250

MagFlux Q 8200 Series

Transcription:

PE202 Low Flow Magmeter Instructions Precision Flow Measurement An ONICON Brand PROUDLY MADE IN THE USA ISO 9001:2008 Certified Company

TABLE OF CONTENTS General Information General Information...Page 3 Features...Page 3 Specifications...Page 4 Dimensions...Page 5 Pressure Drop Curve...Page 5 Installation Positioning...Page 6 Mounting...Page 6 Piping...Page 6 Power Supply...Page 6 Grounding...Page 6 Connections General Connection Information...Page 7 Pulse Output Only with FT520...Page 7 4-20 ma Device and with Single Power Supply...Page 7 Dual Power Supply with Loop Isolation...Page 7 Operation General Operation Information...Back Troubleshooting Problem...Back Probably Causes...Back Things to Try...Back Seametrics 253.872.0284 Page 2 seametrics.com

GENERAL INFORMATION The PE202 magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in 3/4 to 1/4 pipe/tube. The housing is made of sturdy splashproof HDPE plastic. With no moving parts, the PE202 can handle fluids containing particulate matter without clogging or jamming, keeping maintenance at a minimum. With no metallic parts (100% PVDF body and PVDF carbon fiber-filled electrodes), the meter is corrosion-resistant and compatible with a wide range of chemicals (consult factory for chemicals and concentrations). Accuracy is maintained with conductive fluids (>20 microsiemens) of varying viscosities and densities. The PE meter is compact enough to fit most pump/injection systems. With zero straight pipe required after an elbow, it can be easily mounted in tight spaces. The mounting bracket adds stability. The PE meter has an optoisolated current sinking pulse output that can be connected to the Seametrics rate/total display or FT520 batch processor, as well as an optoisolated 4-20 ma current loop for analog devices. Outputs and power are provided through a cable with 8-pin female circular connector. FEATURES 8-pin circular bulkhead connector, 20 foot (6 meter) cable provided Internals made of chemical and corrosion-resistant PVDF Sturdy HDPE housing ½ male NPT fittings standard Mounting bracket Threaded male or female NPT adapters can be purchased separately (available in PVDF and PP) (Female NPT available in 1/2 only) Note: 3/8 male NPT fittings are gray colored. Seametrics 253.872.0284 Page 3 seametrics.com

GENERAL INFORMATION Specifications* Pipe Size 3/4, 1/2, 3/8, 1/4 ** Fittings Materials Body PVDF Electrodes Ground Housing Adapters (NPT) 1/2 NPT fittings standard in 3/4 or 3/8 flowbody. NPT threaded adapters available for above pipe sizes. PVDF carbon fiber filled PVDF carbon fiber filled HDPE with 25% glass Polypropylene or PVDF Temperature Ambient 0 to 130 F (-18 to 54 C) Pressure Fluid 32 to 200 F (0 to 93 C) 150 psi Flow Range -075 20 GPM max. (0.2 GPM cutoff) -038 3 GPM max. (0.03 GPM cutoff) Accuracy -075 ±1% plus ±0.005 GPM of reading across rated range Output Signal Power Conductivity Empty Pipe Detection Environmental -038 ±1% plus ±0.002 GPM of reading across rated range Optoisolated current sinking or current sourcing pulse output: 30 Vdc, 5 ma max Optoisolated 4-20 ma current loop: 7 Vdc plus load voltage drop min; 50 Vdc max -075 500 pulses/liter (1892 pulses/gallon) -038 1000 pulses/liter (3785 pulses/gallon) 10 15 Vdc, 150 ma (linear power supply recommended) >20 microsiemens Hardware/software, conductivity-based NEMA 4X standard; IP66 splashproof standard * Specifications subject to change Please consult our website for current data (seametrics.com). ** Requires adaptors NOTE: Consult factory for applications flowing sodium hypochlorite, sodium chlorite, sodium chlorate. For applications with the listed chemicals, the following conditions apply: Max concentration 15% / Max temperature 100 F Flow is greater than 20% of max for accurate reading Seametrics 253.872.0284 Page 4 seametrics.com

GENERAL INFORMATION Dimensions 7.2 (18.3 7.2" (WITH cm) (with ADAPTERS adapters AS SHOWN) as shown) 4.2 4.2" (10.7 (METER cm) (meter WITHOUT without ADAPTERS) adapters) 4.2 (10.7 4.2" cm) 2.1 (5.3 2.1" cm) Meter ID -038-038 0.19-075 0.50 Mounting Bracket 3.5 (8.9 cm) 3.5" 2.0" 2.0 (5.0 cm) 7.2 7.2" (18.3 (WITH cm) ADAPTERS (with adapters AS SHOWN) as shown) 4.2 4.2" (10.7 (METER cm) (meter WITHOUT without ADAPTERS) adapters) 3.5 3.5" (8.9 cm) 2.0" 2.0 (5.0 cm) Pressure Drop Curve -038-075 3 PE202-075 with 3/4 adapters. PE202-038 with 3/8 adapters. Actual curve dependant on pipe size/fittings Seametrics 253.872.0284 Page 5 seametrics.com

INSTALLATION Positioning The PE202 can be mounted vertically or horizontally. It is important to choose a position that will ensure full pipe. (Under certain conditions of empty or partially-full pipe the meter may give a pulse out when there is no flow.) With a zero straight pipe requirement after an elbow, the PE meter can be installed in tight spaces. FLOW FLOW Piping Metal pipe, metal tube, or plastic tubing can be used with the meter. The standard NPT fittings can be used with or without NPT adapters on 3/4 or 3/8 pipe. If used, apply Teflon tape onto the NPT fittings. NPT adapters should be hand tightened onto the fittings. Thoroughly clean the pipe threads and nose and apply Teflon tape to adapter threads. Hold adapters with a wrench while tightening the pipe to prevent damage to the meter. FLOW Power Supply A 12 Vdc linear, regulated power supply with an output current of at least 0.25A is recommended. If a switching power supply must be used, consult Seametrics for approved manufacturer s model numbers. Mounting It is highly recommended to use the mounting bracket provided. The mounting bracket uses two #8 screws on a 1.5 center. Grounding In addition, it is necessary for proper operation to ground the unit to a good quality earth ground. Assure negative power supply is grounded to earth and to the entire electrical/mechanical system. If metal piping is used, jumper inlet and outlet pipes together and connect to ground for best results in metering accuracy. The cable shield drain wire should be left unconnected. The PE202 may be supported by its piping connections IF the piping is rigid. The meter and pipe must be perfectly aligned with no flexion at the fittings to prevent leakage or damage to the meter. Seametrics 253.872.0284 Page 6 seametrics.com

CONNECTIONS Power and signal connections are provided through the 8-pin male bulkhead connector on the meter housing (20 ft (6 m) cable provided). See the Pin Assignment and Connections diagrams. 5 4 6 3 7 8 2 1 Cable Plug Contact Arrangement Pin # Function Color 1 Pulse (-) White 2 Ground Brown 3 Pulse () Green 4 4-20 () Yellow 5 Not used Grey 6 Not used Pink 7 4-20 (-) Blue 8 Power () Red Pulse Output Only with FT520 Pin 8 Pin 2 PE202 Pin 3 Pin 1 Red 12 Vdc White power Brown Green FT520 SEN 1 12 G SEN 2 4-20 ma Device and with Single Power Supply Important: 4-20mA device input resistance must not exceed 250 Ω 12 15 Vdc 4-20 ma loop 4-20 ma device Blue Brown 7 2 White 1 PE202 3 Green 4 8 Power S May be external or internal to the Yellow Red Sensor Input Dual Power Supply with Loop Isolation 4-20 ma loop 4-20 ma device Brown Power 24 Vdc Blue 7 2 White 1 PE202 3 Green 4 8 S 12 15 Vdc May be external or internal to the Yellow Red Sensor Input May be external or internal to the Seametrics 253.872.0284 Page 7 seametrics.com

OPERATION AND TROUBLESHOOTING OPERATION The meter will output one pulse when powered up. The newly-installed meter takes from a few seconds to a minute for the signal to stabilize at startup, especially if it has been dry. In normal operation, keep the meter filled with fluid and powered on to prevent this delay. When the meter is mounted properly, an empty pipe detection feature will normally detect absence of liquid in the pipe and register zero flow. The 4-20 ma signal outputs 4 ma at zero flow and 20 ma at 20 gallons/minute flow or 3 gallons per minute, depending on model. The pulse signal is a 50% duty cycle pulse set at: PE202-075: 500 pulses/liter (1892 pulses/gallon) PE202-038: 1,000 pulses/liter (3785 pulses/gallon) TROUBLESHOOTING Problem Probable Causes Things to try No output Reversed flow direction Reverse flow connections Empty pipe Flow rate below minimum Loose or incorrect wiring Fluid conductivity too low Electrical noise Material or oils in fluid coating electrodes Check piping conditions Select a different flow meter Check electrical connections Select a different flow meter Relocate meter or reduce noise Using 99% isopropyl alcohol, scrub the bore with soft bristled brush and/or soak bore to remove contaminants Flow rate incorrect Fluid conductivity too low Select a different flow meter Empty pipe Electrical noise Check piping conditions Relocate meter or reduce noise Seametrics 19026 72nd Avenue South Kent, Washington 98032 USA (P) 253.872.0284 (F) 253.872.0285 1.800.975.8153 seametrics.com LT-14229r3.0 20180405 4/5/18