Instruction Manual Updated 12/17/2013 Ver. 1.1

Similar documents
Instruction Manual Updated 8/3/2009 Ver. 1.1

Updated 12/13/2013 Ver. 2.6

Features. HTHP Filter Press for Drilling Fluid Testing DRILLING FLUIDS EQUIPMENT

Model 20 Constant Speed Blender : 115 Volt : 230 Volt. Instruction Manual. Updated 11/14/2017 Ver. 4.0

Features. HTHP Filter Press for Drilling Fluids, 500 ml DRILLING FLUIDS EQUIPMENT

Atmospheric Consistometer # (115V) # (220V) Instruction Manual. Updated 1/25/2018 Ver. 6.0

Benchtop HTHP Curing Chamber. Part No Instruction Manual. Updated 11/7/2017 Ver. 3.0

Electrical Stability Meter. Part No Instruction Manual. Updated 12/10/2015 Ver. 3.0

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

HTHP Filter Press for Cement Testing with 175-mL, Double-Capped Test Cell and N 2 # : (115 V) # : (230 V) Instruction Manual

Model 12BL Filter Press, Multi Unit. # Unit # Unit. Instruction Manual. Updated 08/25/2015 Ver. 2.0

Model 130 Benchtop Consistometer. # Standard # DAS - With Computer for Data Acquisition and Control. Instruction Manual

4-Unit HTHP Filter Press With Load Cell Option. # S VAC # S VAC # S-LC Load Cell Option. Instruction Manual

Dynamic HTHP Filter Press With Magnetic Drive

HTHP Consistometer with Data Acquisition System Model 100 (25,000 PSI, 400 F): DAS (Single Cell) / DAS (Dual Cell)

Ultrasonic Cement Analyzer. Single Cell: # Dual Cell: # Instruction Manual

Digital Resistivity Meter. Part No Instruction Manual. Updated 09/01/2015 Ver. 3.0

Permeability Plugging Tester - P.P.T. 2,000 PSI (13,800 kpa) F (260 C) Part No (115V) Part No (230V) Instruction Manual

PHPA Polymer Concentration Kit. Part No. # Instruction Manual. Updated 1/23/2017 Ver. 2.0

Laboratory Gas Flow Model # VAC # VAC. Instruction Manual. Updated 11/18/2014 Ver. 1.16

Model Speed Viscometer. Features DRILLING FLUIDS EQUIPMENT

Twin Cell Ultrasonic Cement Analyzer. Part No Instruction Manual

CRF-840 Rock-Fluid Centrifuge. Part No. # Instruction Manual. Updated 5/18/2018 Ver. 3.0

EP (Extreme Pressure) and Lubricity Tester

Methylene Blue Test Kit (115 Volt) (230 Volt) Instruction Manual. Updated 2/6/2017 Ver. 4.0

HTHP Filter Press with Threaded Cells for Drilling Fluids Testing. # : 115 Volt # : 230 Volt. Instruction Manual

OFI MODEL 130 HTHP BENCHTOP CONSISTOMETER INSTRUCTIONAL MANUAL

POWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE

NT-500 Technical Support Guide. For use by qualified company approved Technicians

Permeability Plugging Tester. # : 115 Volt # : 230 Volt. Instruction Manual

HTHP Filter Press for Ceramic Disks with 175-mL, Double-Capped Test Cell and CO 2 # : (115 V) # : (230 V) Instruction Manual

INSTRUCTION MANUAL. TEC Controller/Thermocouple Thermometer

Plastic Tube Flar ing Syste m

CHEMINSTRUMENTS HOT ROLL LAMINATOR MODEL HL-100, HL-101 OPERATING INSTRUCTIONS

Centrifuge Operator / Service Manual

Model 700 Microarray Oven

SUREPOWR TM SERIES -SURE 49 FIELD INSTALLATION INSTRUCTIONS

INSTANT JUMPSTARTING POWER USER MANUAL. Copyright PowerStation, LLC All rights reserved MODEL: PS1100

Calibration and Performance Check: Agilent Dual Plasma Controller

AA4006 Speed Sensitive Trip Unit. User Manual

CN-TOT SERIES Portable Thermocouple Temperature Controller

Dinosaur Electronics

troubleshooting guide Robotic Massage Chair

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.

OFITE HTHP Viscometer. Part No Instruction Manual

Please forward any questions or comments regarding this Troubleshooting Guide to

Slide Freedom Automatic Spray Unit Item # 43200

Explosion Proof Drop Light - 12 Volt AC/DC Watt Incandescent - 25' Cord - Twist Lock Plug

June 1, 2008 Please forward any questions or comments regarding this Troubleshooting Guide to

3000 SERIES DRY-BLOCK HEAT SOURCE

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

WP37 & HT37 User Manual

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Explosion Proof Light - Class 1 Division 2 Light - 5 hour Run Time Li-ion Battery - MADE IN THE USA

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

FlexChem Model 404 Rotating Oven

ASTRO. FF-14 Friction Feeder. Operator Manual

Coil Inserter Module

PREHEATER. Instruction Manual

Remote Touch unit and. Select category and scroll to specific customization setting.

Please refer to the 2019 ES 350 Quick Guide or Navigation Owner s Manual for more information on Remote Touch operations.

Rutland Remote Display -Model Installation and Operation

Installation, Operation & Maintenance Instructions 1100 C Chamber Furnaces ELF models

Modul-Connect VEHICLE ELECTRICS MADE SIMPLE

STEP 2 Highlight Setup with the touchpad. Press down to select.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

PCU-200 Laboratory Viscometer

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

Trus-T-Lift 750 Owners Operation Manual. Copyright 2016

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

INSTALLATION & SERVICE GUIDE

Type V Accent Light Installation

Control Replacement # Page 1 REPLACEMENT OF OBSOLETE SEMI- AUTO CONTROLS WITH KIT #

Subject Underhood G System Error Codes and Symptoms System or Parts affected

SUREPOWR TM SERIES -SURE 24/25 FIELD INSTALLATION INSTRUCTIONS

BENCHTOP INSTRUMENT. Multi-channel DC Power Supply TP2000N/TP2000PU/TP4000N Series Operation Manual V1.0

RESPA -CF2 Installation Kit for John Deere K and K-II Wheel Loaders

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

OFI MODEL 60 ATMOSPHERIC CONSISTOMETER INSTRUCTIONAL MANUAL

AUTOMATIC AIR CONDITIONER > COMPONENT DIAGNOSIS > BLOWER MOTOR CONTROL SYSTEM > SYSTEM DESCRIPTION > SYSTEM DESCRIPTION

TIRE PRESSURE MONITORING SYSTEM

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

Ultrasonic Sensor U-B

APOLLO Gate Operators, Inc.

CAUTION. Even Brakes with a black cable need second vehicle kit Even Brakes with a blue cable need second vehicle kit 98450

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

materials and workmanship for 2 years. Should the centrifuge require warranty or Phone: or Fax:

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

U. Electric Golf Cart (egc) CHARGING PROCEDURE. California Roadster. HUMMER H3 egc. Cadillac Escalade egc

BSNL POWER PLANT MANAGEMENT SYSTEM USING VOICE ALONG WITH TELEPHONE LINE

USER MANUAL Installation, Operation, and Maintenance

Monogram Series DUAL RATE CHARGER MHCH3V

Press the DISP switch several times until the SETTINGS screen appears. Press and hold the DISP switch to display the customize mode screen.

Preheater. Instruction Manual

3. Operating instructions: Minor 200

Transcription:

Temperature Control Unit #171-49: Single Unit, 115 Volt #171-49-4: Four Unit, 115 Volt Instruction Manual Updated 12/17/2013 Ver. 1.1 OFI Testing Equipment, Inc. 11302 Steeplecrest Dr. Houston, Texas 77065 U.S.A. Tele: 832.320.7300 Fax: 713.880.9886 www.ofite.com Copyright OFITE 2013

Table of Contents Introduction...2 Components...2 Specifications...2 Photos...3 Operation...4 Timer Operation...5 Fuse Replacement...6 OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 1

Introduction The OFITE Temperature Control Unit is a convenient tool for precisely controlling the temperature of an electrical heating device. Simply plug the heating device into the Temperature Control Unit and the built-in Eurotherm 2123 controller will regulate the power output to the heater. The controller can be set with either a simple temperature setpoint or an advanced timer. The Temperature Control Unit is ideal for use with thermocups, hot plates, retorts, and heating jackets for filter presses. Components #120-70-1-003 Fuse Holder #130-76-03 Thermocouple #152-37 Power Cord #174-03 Electronic Controller, Eurotherm Model 2132 #172-09 Fuse, 10 Amp, Box of 5 Specifications - Maximum Temperature: 450 F (232.2 C) - Maximum Power: 10 amps - Temperature Controller: Eurotherm 2132 - Detailed instructions available from Eurotherm: http://www.eurotherm.com/support/manuals/2132.htm OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 2

Photos Page Scroll Heat Fuse Holder Power Outlet Thermocouple Inlet Main Power Power Outlet Thermocouple Inlet Power Inlet OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 3

Operation 1. Plug the Temperature Control Unit into an appropriate power source. The power inlet is on the back of the unit. Note! Important! Important Note The four unit model (#171-49-4) has two power inlets on the back. The one on the left provides power to units 3 and 4. The one on the right provides power to units 1 and 2. 2. Plug the heating device into the Temperature Control Unit. The unit has a power outlet on the front and one on the back. Do not use both power outlets at the same time. Doing this could cause the unit to draw too much power and blow the fuse. 3. Plug the thermocouple into the thermocouple port. The unit has a thermocouple port on the front and one on the back. Do not use both thermocouple ports at the same time. Doing this could could result in incorrect readings. 4. Turn the Main power switch on. The Eurotherm controller will run through a short series of self tests. At the end of the tests the display will show the current ambient temperature. This is the home screen. The four unit model has two Main power switches. The one on the left controls units 1 and 2. The one on the right controls units 3 and 4. 5. Use the Up and Down arrows to select a temperature setpoint. The OP1 light in the upper left-hand corner of the display will illuminate when the controller is sending power to the heating device. 6. Turn the Heat switch on. Note The Heat switch controls power to the power outlet. If the Heat switch is off, the heating device will not receive any power from the Temperature Control Unit, regardless of the reading on the display. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 4

Timer 1. Use the Up and Down arrows to select a temperature setpoint. 2. Press the Page button until the display reads SP. 3. Press the Scroll button until the display reads tm.op. 4. Use the Up and Down arrows to select one of the five timer programs: Opt. 1 - The controller will engage the heater up to the temperature set point before the timer starts. When the timer times out, the controller will turn off the heater. The display will flash END to signal that the timed program is complete. Opt. 2 - The controller will engage the heater up to the temperature set point before the timer starts. When the timer times out, the display will flash END and leave the heat on indefinitely. Opt. 3 - The controller will engage the heater up to the temperature set point while the timer is running. When the timer times out, the controller will turn off the heater. The display will flash END to signal that the timed program is complete. Opt. 4 - The controller will engage the heater up to the temperature set point while the timer is running. When the timer times out, the display will flash END and leave the heat on indefinitely. Opt. 5 - The controller will engage the heater up to the temperature set point after the timer times out. The heater will remain on indefinitely and the controller will return to normal operation. 5. Press the Scroll button until the display reads tmr. Use the Up and Down arrows to set the time (in minutes) that you want the timer program to run. 6. Press the Page and Scroll buttons simultaneously to return to the home screen. The timer program will now begin to run. 7. When the timer times out, the controller with enter standby mode (unless Opt. 5 is used). You must exit standby mode before using the timer again. a. If the display is flashing End, press the Page and Scroll buttons simultaneously to return to the home screen. b. If the MAN light is on, press the Scroll button until the display reads M-A. Press the Up arrow until the display reads AUTO. Press the Page and Scroll buttons simultaneously to return to the home screen. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 5

Fuse Replacement If the Temperature Control Unit does not power up when the Main switch is turned on, replace the fuse on the front of the unit. 1. Make sure the unit is unplugged from the power source. 2. Press the fuse holder in and turn it counter-clockwise ¼ turn. 3. Remove the fuse holder and replace the fuse. 4. Push the fuse holder back into the receptacle and turn it clockwise ¼ turn to lock it in place. 5. Plug the unit back into the power source and turn on the Main switch. OFITE, 11302 Steeplecrest Dr., Houston, TX 77065 USA / Tel: 832-320-7300 / Fax: 713-880-9886 / www.ofite.com 6