WaltZilla TM Installation and Operation Guide

Similar documents
OpenEVSE - 40A Charging Station

OpenEVSE. Testing Basic and Advanced

INSTALLATION GUIDE AND USER MANUAL

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Installation Manual & Warranty

INSTALLATION GUIDE AND USER MANUAL

Electric Vehicle Charging Station

Installation and Construction Notes for EVSE4

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Installing Power Components

MIL-24/2600Q MIL-24/3200DQ

WattStation Wall Mount User Manual

EVoInnovate EVSE Model Numbers: EVO & EVO User Manual & Installation Guide. Revision 1.0

USER GUIDE TURBOCORD TM PORTABLE CHARGER 240V. AeroVironment EV Solutions

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

Model No. PS-2000 WARRANTY AND OPERATING INSTRUCTIONS

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

READ AND SAVE THESE INSTRUCTIONS. Installation manual. DCC Charge controller for electric vehicle DCC-9, DCC-10. V2-6 Avril 2017.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

TRAVEL CORDSET AND WALL STATION TEST REPORT

DC to AC Power Inverters

DC to AC Power Inverters

FLO Home TM X5 Model. Installation Manual FLO Services Inc. All rights reserved.

OWNERS MANUAL JANUARY 2007 ISO

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

Application Engineering

FLO Home TM G5 Model. Installation guide

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

ITS-50R TRANSFER SWITCH OWNER S MANUAL

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model ACS

Installation Instructions

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

Application Engineering

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

WF-5110R True Sine Wave Inverter

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Power Xpress Bollard Charge Station Installation Guide

WF-5110R True Sine Wave Inverter

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

INSTRUCTION & INSTALLATION

Power Inverter 400 MW Owner s Manual

DSEULTRA DSE6000 Quick Start Guide Document Number

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Model LA 4300 Time Delay OFF Controller

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

E Series CE Approved Intermittent Pilot Ignition Control

SECTION WIRING DEVICES

ADI-125/750 ADI-125/1500 ADI-125/2500

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

Touchstone TB130 DC Output UPS

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

System 3 ZB1PS Device Chassis. Operator s Manual

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

Model LA 4100 Time Delay OFF Controller

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

Powerful & Intelligent Submersible Pumps

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

Engine 3 Installation

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

OWNERS MANUAL JANUARY 2007 ISO

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

Model LA 4400 Time Delay OFF Controller

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

Manual PN: Rev 01. Otterbine Barebo Inc. Fractional Series 50Hz Installation Manual

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Illumifalls Patio Pond

Operating Instructions for PAC800 Battery Charger

Owner s Manual. Features

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Declaration of Conformity

High Frequency SineWave Guardian TM

INSP-3 Wiring Inspection Tester

Updated: October 2012

Patient Care Facility

Technical Manual. DLM Module. This manual should remain with the unit.

More innovative solutions for an ever-evolving world. Electric Vehicle Chargers

MODEL 422 Submersible Pump Controller

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Cruising Charger Series OWNER S MANUAL

S150,S300 Series Pure Sine Wave Inverter User s Manual

G72x Series Direct Spark Ignition Controls

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Volume CHARGESTORM AB. User Guide CSR100

Patient Care Facility

Transcription:

The Boldest, Baddest Charging Station on the Planet! WaltZilla TM Installation and Operation Guide Software Version 2.0.1 or higher UL File # E473741 LiquidSky Technologies, Inc. 716 Beacon Street Newton Centre, MA 02456 Tel. 857-389-9893 www.liquidskytechnologies.com 2017 LiquidSky Technologies, Inc. Pub. No. 81855, Rev. a1.0.4, 04/24/17 Printed in USA

Product Description Product Description WaltZilla is a UL-listed electric vehicle charging station (EVCS), a category of EVSE charging equipment available from LiquidSky Technologies, Inc. WaltZilla is an in-the-wall 80 Amp EVCS built for interior use that is mounted nearly flush to drywall. WaltZilla will charge any electronic device or vehicle that conforms to the J1772 charging standard, including electric cars, boats, motorcycles, snowmobiles, bicycles, campers, etc. WaltZilla is designed to be the last charger you will ever need, housed inside a scratch-resistant, mirror-finished, Type 1, 316 stainless steel enclosure featuring proprietary gold plated circuit boards that resist corrosion. WaltZilla comes ready for your electrician to install anywhere in your home. WaltZilla installs inside a standard 2x4 construction with a small yet elegant footprint that makes it ideal for use in high-end homes, hotels, theaters, public accomodations offices, shopping centers and entertainment venues. Figure 1. Wall-Mounted WaltZilla With WaltZilla you can charge a single electric vehicle (EV) (e.g., the Tesla Model S) at the highest rate that the J1772 AC standard permits. WaltZilla is easy to use - virtually plug and play. The WaltZilla requires 208-240 VAC at 50/60 Hz, single phase and one independent, properly fused and/or breakered 100 Amp branch circuit. Consult your electrician for additional local requirements. WaltZilla comes with one standard 25-foot cable complete with a J1772 coupler to reach between the charging port and the vehicle. 1 The coupler works with all electric vehicles sold in the US or Canada. WaltZilla features a multicolor front LCD that shows the amperage being delivered for the duration of the charge as well as other operational information. Features minimal stand-by power consumption with no on/off switch required. WaltZilla is warrantied for residential use only. Made in the USA. 1.Some vehicles require special adapters. Consult your vehicle s user manual for more information. Tesla includes a J1772 adapter with every vehicle. Page 2 WaltZilla Installation and Operation Guide

About the WaltZilla LCD About the WaltZilla LCD The LCD displays the operational status of WaltZilla, including the charging duration and the total number of Amps being delivered to the EV at that moment in time. The LCD codes displayed inside the WaltZilla enclosure are visible through the viewing lens on the cover of the enclosure. (See examples of the WaltZilla LCD codes in Figure 2.) Information displayed on the LCD is color coded with the following meanings: Green indicates the normal operational state. Blue indicates a transitional state occurring when changing operational states. Red indicates an error. Figure 2. Examples of the WaltZilla LCD Codes WaltZilla Installation Instructions You can install the WaltZilla enclosure between two wall studs, either in a new installation. A typical installation is shown in Figure 3. 16 on center 1.5 x 3.5 (2x4) Studs 7-3/8 14-15/16 11-7/8 ENCLOSURE WaltZilla Faceplate (8-3/8 W x 12-7/8 H) WaltZilla Enclosure (7-3/8 W x 11-7/8 H) 12-7/8 Figure 3. WaltZilla Mounting WaltZilla Installation and Operation Guide Page 3

WaltZilla Installation Instructions Ensure that the WaltZilla enclosure is mounted securely to two studs and in accordance with your local requirements. Consult with your local building inspector for more information. Read all of the installation instructions provided in this document prior to attempting installation of WaltZilla. Consult with your local building inspector and other required authorities as necessary to review the installation at the appropriate installation stages and prior to applying power to WaltZilla. Warning: Do not apply power to WaltZilla until the installation is completed, your local building inspector has approved the installation and all other requirements have been fulfilled to operate WaltZilla. PREREQUISITES: WaltZilla Enclosure and WaltZilla Completion Kit (8) 2-4 SS corrosion-proof Phillips lag screws (10) 8-32 x 3/8 PH FL 100 DG M/S 18-8SS Flathead screws Stud finder (as necessary), screwdriver, level, plaster and paint (customer supplied) 1. If installing WaltZilla in an existing structure, do the following: a. Study the illustration in Figure 3 to determine the size and location of the WaltZilla installation. b. Identify and mark an installation area on the drywall between the outer edge of each stud (at least 18 in. W x 16 in. H) (Figure 4). 18 2 Studs Cut Out & Remove Drywall 16 18 Figure 4. Exposing Studs in Existing Wall c. Cut out the area of the drywall you marked to expose the studs. Page 4 WaltZilla Installation and Operation Guide

WaltZilla Installation Instructions 2. Consult with your local building inspector and local code requirements to determine a suitable and safe height and location for your WaltZilla enclosure. 3. Using Figure 3 as a guide, install and secure 2x4 studs as necessary to allow WaltZilla to be secured to two vertical wall studs. Figure 3 shows one possible configuration in which a vertical wall stud is located between two existing vertical studs and supported by horitontal studs below and above it. 4. On each of the four rack ears attached to the corners of WaltZilla, locate the holes that can be used to secure the enclosure to the studs (see A and B callouts in Figure 5). A ENCLOSURE B Figure 5. WaltZilla Rack Ear Screw Holes 5. Wire WaltZilla to an inactive, properly grounded 208-240 VAC at 50/60 Hz, single phase, independent, properly fused and/or breakered 100 Amp branch circuit. Consult your electrician for additional local requirements. Warning: Do not apply power to WaltZilla until the installation is completed, your local building inspector has approved the installation and all other requirements have been fulfilled to operate WaltZilla. WaltZilla Installation and Operation Guide Page 5

Operating WaltZilla 6. (Note: Two people are necessary to perform this step.) With one person holding the enclosure in place between two vertical studs, use a Phillips screwdriver to install two 2-4 SS corrosion-proof Phillips lag screws (provided) into each rack ear. You can use any combination of available holes in each rack ear to secure the unit. Hand tighten each screw until the enclosure is secure. 7. As necessary, protect the WaltZilla exterior prior to refinishing the installation area. Use drywall, plywood with plaster or other material to finish the area as desired, and when dry, paint the finished surface. Remove protective material from WaltZilla when finished. 8. Using a flathead screwdriver, hand tighten the (10) 8-32 x 3/8 PH FL 100 DG M/S 18-8SS flathead screws to secure the chrome plated face plate to the front of WaltZilla. 9. Install the rackmount assembly (optional) and secure the J1772 coupler to the assembly. 10. Consult with your local building inspector and other required authorities as necessary to review the installation prior to applying power to WaltZilla. Warning: Do not apply power to WaltZilla until the installation is completed, your local building inspector has approved the installation and all other requirements have been fulfilled to operate WaltZilla. Operating WaltZilla The following procedure explains how to use WaltZilla to charge an EV. Warning: Before connecting WaltZilla to a vehicle, ensure that the vehicle is J1772 compatible, or the vehicle is supplied with an adapter (such as those provided by Tesla) to allow the unit to charge the vehicle. Note: For information on codes or other information displayed on the LCD, please reference Interpreting LCD Codes" (page 7) and Troubleshooting Error Codes" (page 7). To Charge a Vehicle Using WaltZilla: 1. Plug the coupler into the vehicle s charging port. An audible bang indicates that the GFI circuit test is completed and WaltZilla has uncoupled the electrical connector to allow for charging. 2. The WaltZilla LCD should display charging. Warning: If there is a fault, the display will turn red and display the fault. Remove the coupler and correct the fault before reinserting the coupler. Page 6 WaltZilla Installation and Operation Guide

Interpreting LCD Codes 3. To determine charging duration, please follow the charging times recommended by the manufacturer of your vehicle. Interpreting LCD Codes Please refer to the Table 1 for interpreting the LCD information displayed on the WaltZilla LCD. For an understanding of error codes, please see the next section, Troubleshooting Error Codes" (page 7). Table 1. LCD Codes and Meanings LCD Display (Position) Meaning Ready (top line, left side) Charging (top line, left side) Error (top line, left side) Stopped (top line, left side) Waiting (top line, left side) Sleeping (top line, left side) L2:80A (top line, right side) EV State and Current Charging Session (bottom line) WaltZilla is ready. Troubleshooting Error Codes WaltZilla is ready to charge or is charging. WaltZilla has detected an error. WaltZilla has been stopped. WaltZilla is waiting for a timer. WaltZilla is sleeping. The meaning of these two default fields are defined here: L2 when in Ready state, this field indicates that there is 240V input voltage. 80A specifies the maximum allowed current by WaltZilla (e.g., 80A). Note: This information is displayed only when the state on the top line, left side of the LCD is Ready, Charging, Error, Stopped, Waiting or Sleeping. Specifies one of the states of the EV and the current charging session: EV Not Connected the EV is not connected to WaltZilla. EV Connected the EV is connected to WaltZilla. Note: This information is displayed only when the state on the top line, left side of the LCD is Ready, Charging, Error, Stopped, Waiting or Sleeping. Elapsed Time (bottom line, left side) When WaltZilla is in the Charging state, the elapsed time since starting the charging session is displayed in the format hh:mm:ss (where hh is hours, mm is minutes and ss is seconds) (e.g., 00:03:08). Reference Table 2 for a list and description of LCD error codes and corrective actions. Table 2. Troubleshooting LCD Error Codes LCD Error Code Meaning Corrective Action(s) Errors During Power On Self Test Earth Ground Test Failed GFCI Self Test Failed WaltZilla could not detect a ground connection. WaltZilla did not detect a ground fault circuit interrupt (GFCI) fault during test. Check ground connections and AC_Test lines. Check GFCI CT and self test coil. WaltZilla Installation and Operation Guide Page 7

Safety Features Table 2. Troubleshooting LCD Error Codes LCD Error Code Meaning Corrective Action(s) Stuck Relay Test Failed Operating-Time Errors WaltZilla read AC voltage before relays were closed. Check relay and AC_Test lines. GFCI Fault WaltZilla detected a ground leakage of > 20ma. No Diode WaltZilla did not detect the J1772 vehicle diode. WaltZilla will retry charging after 15 minutes up to 4 times. No Ground WaltZilla lost connection to ground. Check grounds and AC_Test lines. N/A Safety Features WaltZilla supports all the safety features required (and a few more) by standards documents for EV charging from standard SAE J1772, NEC and UL, including: UL2251 Standard for Plugs, Receptacles and Couplers for Electric Vehicles UL2231 Standard for Personnel Protection Systems for Electric Vehicle (EV) Supply Circuits SAE J1772 Electric Vehicle Conductive Charge Coupler Standard NEC Article 625 Electric Vehicle Charging System Equipment Power Interlock WaltZilla includes an interlock that de-energizes the EV connector and cable whenever the electrical connector is uncoupled from the EV (NEC 625.18). Pilot Signal WaltZilla supports the SAE J1772 pilot signal that automatically de-energizes the cable conductors and EV connector upon exposure to strain that could result in either cable rupture or separation of the cable from the electric connector and exposure of live parts (NEC 625.19) (SAE J1772). Self-Test WaltZilla performs a self-test during start up to ensure the unit is working properly and safely. Upon power-up and/or at the time of charging, WaltZilla performs some or all (depending on state) of these selftest checks: GFCI fault detection checks for missing ground by responding to a 20mA ground fault condition Test for missing ground Test of the welded relay contact monitor circuit Other tests Page 8 WaltZilla Installation and Operation Guide

Warnings and Notes Ground Monitoring WaltZilla checks ground upon power-up and constantly monitors for the presence of a proper safety ground. (SAE J1772) Ground Fault Interrupt WaltZilla includes mandatory ground fault interruption with a 20ma trip in all models available for protection against electric shock of personnel. (NEC 625.22) (SAE J1772) (UL 2231) After each GFCI event, WaltZilla will retry charging up to 4 times after a 15-minute delay per event. (UL 2231) Stuck Relay Detection WaltZilla checks relay contacts every time it starts to charge to ensure relays are functioning properly and providing proper power interlock. EV Identification WaltZilla verifies the pilot signal integrity by checking the EV diode. The pilot signal must be at BOTH the correct resistance AND pass the diode check to activate the circuit. (SAE J1772) Note: This safety feature is commonly left out of many other commercial charging stations. Ventilation Required WaltZilla checks for the EV ventilation required request. WaltZilla will deny charging if ventilation is not available or allow charging if the charging station is equipped to activate ventilation. (SAE J1772) Note: This safety feature is commonly left out of many other commercial charging stations or implemented with a warning label only. Warnings and Notes Please heed these warnings and notes. Warning: Adult supervision is required when building, operating, servicing or inspecting. WaltZilla Installation and Operation Guide Page 9

Warnings and Notes Warning: Installation of an EV charging station requires wiring Alternating Current (AC) components that will be exposed to voltages from 100 to 250v. If you do not have the experience and knowledge required to safely work with AC voltages please consult with an experienced electrician for assistance and inspection of your work. Warning: Do not install WaltZilla near flammable, explosive, or combustible materials. Do not locate or store flammable, explosive, or combustible materials near the charging station. Warning: Do not operate the WaltZilla with a visibly damaged cable or if the enclosure or connector is broken, open, cracked, or shows any other signs of damage. Note: Regularly inspect your WaltZilla. Pay special attention to excess heat. Note: Important always disconnect your charging station from power before performing an inspection and/or maintenance. About LiquidSky Technologies LiquidSky Technologies, Inc. is a high technology company engaged in the design of state of the art products in the power industry. Copyright 2016 LiquidSky. All rights reserved. Patent Pending. WaltZilla TM is a trademark of LiquidSky Technologies, Inc.. All other third-party trademarks and service marks referred to in these materials are the property of their owners. No part of this documentation may be reproduced in any form or by any means or used to make any derivative work (such as translation, transformation, or adaptation) without written permission from LiquidSky Technologies, Inc. LiquidSky Technologies, Inc. provides this documentation AS IS, without warranty, term, or condition of any kind, either implied or expressed, including, but not limited to, the implied warranties, terms, or conditions of merchantability, satisfactory quality, non-infringement and fitness for a particular purpose. LiquidSky Technologies, Inc. reserves the right to make changes to equipment design or program components described in this documentation, as progress in engineering, manufacturing methods, or other circumstances may warrant. No responsibility is assumed for the use of LiquidSky Technologies, Inc. software or hardware, all rights, obligations and remedies related to which are as set forth in the applicable sales and license agreements. LiquidSky Technologies, Inc. 716 Beacon Street Suite 590506 Newton Centre, MA 02456 Tel. 857-389-9893 www.liquidskytechnologies.com Info@liquidskytech.com Mailinglist@liquidskytech.com Press@liquidskytech.com Investments@liquidskytech.com Published April 24, 2017. Printed in United States of America Page 10 WaltZilla Installation and Operation Guide

GPL License Information GPL License Information GENERAL PUBLIC LICENSE INFORMATION IS FORTHCOMING WaltZilla Installation and Operation Guide Page 11