SPREADER SYSTEM. Proportional three function. 1. Features and Specifications. User Manual 12 INPUTS 12 OUTPUTS CONNECTIVITY MAIN FEATURES

Similar documents
CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

CS 440RC. Solid De-icer Controller Operator Manual

MICROPROCESSOR BASED CONTROLLER

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

Continental Hydraulics Installation Manual CEM-AA-A

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

RVS-DN Digital Reduced Voltage Motor Starter

INSTALLATION AND OPERATION INSTRUCTION

SmartON / SmartON+ Installation and Use Manual

Flow Transmitter / Switch OMNI-RR..32

Section 55 Chapter 6

SMT-150 Installer Manual

MiX 2310i with IP Housing. P r o d u c t I n f o r m a t i o n G u i d e

RESISTIVE LOAD XP300C

Instructions Manual Control Unit RCU205

MCD 200 Series Soft Starters

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

Flow Transmitter / Switch OMNI-RR..32

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

30A BLDC ESC. Figure 1: 30A BLDC ESC

USERS MANUAL MCD REMOTE OPERATOR

Flow Transmitter / Switch OMNI-RR..32

CENTRIFEEDER ELECTRONICS

Generator Sets Controller 210. Operation Manual. Ver1.0

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Operating Instructions Overcurrent Protection - Tester

Model H30 Operation Manual

Vission 20/20 micro-controller. Operation and service manual

Rally computer 3 Rally computer 3.GPS *

Fuel Level FL1. FL1 - User s manual. Rev Revision#2.0, 28/11/2014 For firmware version 1.2

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

ICON 2 1. FEATURES AND CHARACTEIRICS

TITLE PAGE... 1 HOW IT WORKS... 2 CALIBRATION VALUES... 4 SYSTEM PARAMETERS... 4 HYDRAULIC PARAMETERS... 6 TRUCK PARAMETERS... 8

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

ECU1000 ELECTRONIC CONTROL UNIT

SNMP dedicated to ORVALDI Solar Infini

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

CS 550/150RC Towplow. Spreader Joystick Controller Operator Manual

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

Dielectric Withstand Tester

UPS Wizard User s Manual

LAMBDA SENSOR CONTROLLER

ELIOS 25 DIGITAL CONTROL UNIT WITH LCD DISPLAY FOR THERMAL SOLAR SYSTEMS TDS 006 M00 0SE A

ALFA-Club. Owners Manual Rev 4.0, August Small Systems Specialists 201 N. Lobb Ave. Pen Argyl, PA Memory Checkpoint Clock

RADIO FREQUENCY SYSTEMS

Pandora would like to thank you for choosing our LIGHT+ service and security system

CS102 Spreader Control Manual. General Description

Electric Actuator Options & Accessories

Whad 0.8, 1, 1.5 kva. Manuel d installation Installation manual. Part. LE05733AA-07/12-01 GF

The company 4. CM Series Engine Control Panel 6 CM 40 Series CM 20/30 Series CM 2A/3A Series CM 02 Series CM 60 Series

ELECTRICAL PANELS. Chap.

DATE: 7/29/99. PAGE: 1 of 32

OPERATING INSTRUCTIONS ECON-M

Stratomaster Smart Single

Owner s Manual. Advanced Wind/Solar Hybrid (Street Light) Controller

DC3N Non-Regenerative DC Drives

The measurements module provides the following engine features information:

Installation and use. Controller for Rapid Bike Evo and Rapid Bike Racing modules. Issued by: PM approved by DG Rev.00 date 09/01/15 pag.

Owner s Manual. MG2000 Speedometer IS0211. for use with SmartCraft Tachometer

True Fail-Safe Technology and Precision Control for Reliable Shutdown

TE2010-GE Instructions manual

Quick Setup Guide for IntelliAg Model YP Air Pro

AC drive has detected too high a Check loading

INSTRUCTION AND USE MANUAL

CONTROL UNIT OMEGA 800-R. User manual

SPEEDRIVE INSTRUCTIONS MANUAL

Flight Systems. Replacement for KASSEC DESCRIPTION

TECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2

Temperature Controller OVATION 214 User's Guide

SAFETY- FLY 700 P USER MANUAL FLYING INSTRUMENT FOR ULTRALIGHT AIRCRAFTS NR MIT

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

BMS SV 24S for 2S-24S LiPo, LiFe & LiTO&others Low power consumption High accuracy 2.8 TFT LCD display Programmable

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

B-RAD Select USER MANUAL TABLE OF CONTENTS

PV Generation System. Solar Charge Controller SPECIFICATION

Be2K-Plus AMF panel control wiring --

M-VUE The Intelligent Valve Monitor

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Gate & Door Controller with LCD and Intelligent Technology

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

Application Software Dual Path Control DPC

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

MAGPOWR Spyder-Plus-S1 Tension Control

CARRARO TRAX TLB2 Electronic Module Specification. 29/11/2006, Rev. 5

Switch select of sender types:

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Instrument Panel TABLE OF CONTENTS. Instrument Panel Warning Lights and Indicators Meter Cluster ODOmeter/Trip ODOmeter...

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Transcription:

User Manual SPREADER SYSTEM Proportional three function 12 INPUTS 3 interrupt digital inputs. 3 digital inputs for engine control (alternator, accelerator, oil alarm). 1 digital input for tachometer (squared, sinusoidal, half wave signals). Other 2 analog inputs. Other 3 digital inputs. Note: almost all inputs are analog and can be configured as digital (PNP or NPN). 12 OUTPUTS 3 PWM current outputs with feedback (1500mA max, 3A as option). 5 outputs for engine management (alternator, accelerator, decelerator, start, stop). 2 outputs for chute positioning. 2 outputs for beacon and working lamps. Note: on/off outputs can drive up to 3A. For higher currents a relais box has to be used. 1. Features and Specifications MAIN FEATURES Up to 3 functions with/without feedback. Engine management. Light management. Integrated GPS device (optional) for vehicle speed measurement. 3 potentiometers for function ergonomic setting. GSM-GPRS device (optional) through CANbus. Graphic display 128x64 dot backlighted. 9 backlighted pushbuttons. 4 high brightness LEDs. Real time clock with calendar for event recording. 192 kbyte memory for events. 434 MHz radio connection (optional). 35 way AMPseal connector. 9-30Vdc voltage power supply. Function setting: minimum, maximum, ramps, dither, frequency. DIMENSIONS Aluminium enclosure, IP67. Width 225 mm, height 110 mm, depth 45 mm. CONNECTIVITY RS232 serial line to connect a host computer for data upload and download. CAN bus line. 434 MHz bidirectional radio communication line (option). GPS SPECIFICATIONS Position accuracy: 1.8 m (CEP95) Vehicle speed accuracy: 0.1 m/s Update rate: 1Hz, optional 5Hz Note: GPS device is backup supplied. The Cold start (first time on) can require up to 20 minutes, a Warm start is typically 20 seconds.

Proportional three-function control box for salt spreader 3 4 5 9 10 2 1 20 19 18 12 11 17 16 6 7 15 8 14 13 2. Description and Function of the Operators 1. MAIN SYSTEM SWITCH Through the main relay contained in the shunt box, the main system switch enables the activation of the system, if the emergency push-button is released. 2. SERIAL CONNECTOR BUS RS232 DB9 connector to serial gates of your personal computer. It can be used to edit settings and for firmware upgrade. PAGE 2 3. ENGINE WARNING LIGHT It lights up in case of engine oil pressure or alternator alarm signal. It blinks in case of low fuel if the above mentioned alarm signals are off. 4. ROTOLAMP ON/OFF ILLUMINATED PUSHBUTTON (2 FUNCTION UP) It works as a set/reset pushbutton. Switches on and off the rotating lamps. In the diagnostic or calibration mode, it is the UP pushbutton (menu scroll up). 5. ENGINE ON/OFF ILLUMINATED PUSHBUTTON (2 FUNCTION ESC) When the engine is off, the pushbutton activates the engine start in presence of an oil pressure alarm signal. When the engine is running, the starter will not be activated. In the diagnostic or calibration mode, it is the ESC pushbutton (menu quit). 6. HEAD LAMP ON/OFF ILLUMINATED PUSHBUTTON (2 FUNCTION DOWN) Switches on and off the head lamp. In the diagnostic or calibration mode, it is the DOWN pushbutton (menu scroll down). 7. THROTTLE ILLUMINATED PUSHBUTTON (2 FUNCTION ENTER) Switches on and off the vibrators with timer (10 seconds ON then it switches them OFF).

In the diagnostic or calibration mode, it is the ENTER pushbutton (menu confirmation). 8. BLAST ILLUMINATED PUSHBUTTON With spreading mode running ( Spread On light on), the pushbutton allows to force maximum material spreading as long as the pushbutton is held down. 9. SPREADING FUNCTION START/STOP ILLUMINATED PUSHBUTTON If the material spreading isn t activated, push the pushbutton to activate it and vice-versa. Spreading mode activation is indicated by the Spread On green led light. 10. MATERIAL AMOUNT SETTINGS POTENTIOMETER After a minimum spreading width is set, the potentiometer sets the material spreading amount from a minimum to a maximum, by acting on the proportional valve which controls the rotation speed of the screw conveyor engine. 11. LIQUID AMOUNT SETTINGS POTENTIOMETER After a minimum spreading width is set, the potentiometer sets the material spreading amount from a minimum to a maximum, by acting on the proportional valve which controls the rotation speed of the engine water pump engine. 13. SPREADING WIDTH SETTINGS POTENTIOMETER It sets the spreading width from a minimum to a maximum, by acting on the proportional valve which controls the spinner engine. 14. MENU ILLUMINATED PUSHBUTTON Illuminated pushbutton which allows to enter the diagnostic or calibration mode menu. 15. BACKLIT DISPLAY It shows the current operating modes and parameters. 16. ILLUMINATED PUSHBUTTON FOR RIGHT TAIL SHIFTING (2 FUNCTION +) Operate the DC motor for right tail shifting. In the diagnostic or calibration mode, it is the PLUS pushbutton (to increment a value). 17. ILLUMINATED PUSHBUTTON FOR LEFT TAIL SHIFTING (2 FUNCTION ) Operate the DC motor for left tail shifting. In the diagnostic or calibration mode, it is the MINUS pushbutton (to decrement a value). 18. SPREAD ON GREEN LIGHT If on, indicates spreading mode activated. It blinks if the vehicle speed is under 5km/h, thus spreading mode is not active. 19. SPREADER ALARM RED LIGHT If spreading mode is activated, the indicator lights up in case of material exhaustion. If spreading mode is activated, the indicator blinks in case of low water. In case of low water the water pump is switched off. 20. SPINNER RAISED RED WARNING LIGHT It lights up if the spinner slants compared to the operating position. In such cases, the buzzer also emits three acoustic signals. Whenever this warning light is up, the material spreading is stopped and the relevant Spread On turns off. In order to reset the spreading mode, the spinner must be lowered to its normal operating position, then the spreading mode activation pushbutton must be pushed a new. 12. AMPSEAL MALE CONNECTOR 35 POLES It connects the control box to the shunt box containing the relays and cables directed to wards the system users. PAGE 3

3. System Use POWER SUPPLY The power supply can be 12Vdc direct current or 24Vdc direct current (depending upon the application and the relay kit ordered with the system). Always supply power to the system with the correct voltage in order to avoid breakdowns and system failures. After system installation, connect it to the battery. Connect the blue wire to the positive terminal and the brown wire to the negative terminal. Even though the system is protected against reverse polarity of the power supply, always be careful to perform the correct cable connection. To activate the system, release the emergency push-button. Press the emergency push-button whenever needed. Before disconnecting the control unit, press the main push-button or the emergency push-button to make sure the system isn t powered. SYSTEM START The system is started by the switch button #1 which will activate the system by the main relay contained in the shunt box. If the emergency push-button is not released, the system will not start. If the system has been successfully started, the display will turn on. ENGINE START/STOP With the engine turned off and the oil pressure warning light turned on, (warning light #3), the engine can be started by holding the Engine Start (pushbutton #5) for at least three seconds. The three seconds are those needed by the diesel engine glow plugs. If the engine is running, pushing again the pushbutton #5 will activate the engine stop. If the engine is running, the light #3 indicates the amount of fuel reserve. PAGE 4

4. Operating Mode Selection By holding down the Menu pushbutton #14 the display will visualize the SELECT OPERATION page showed here. By pushing the pushbuttons #4 UP and #6 DOWN it is possible to scroll the list in order to select the operating mode needed. The selected operating mode is identifiable by light text on dark background. Once the operating mode has been selected, it is validated by holding the pushbutton #14. It is possible to choose between the following operating modes: MIX-SALT 1 Moistened salt spreading with the 1 st parameter set. MIX-SAND 1 Moistened sand or gravel spreading with the 1 st parameter set. MIX-SALT 2 Moistened salt spreading with the 2 nd parameter set. MIX-SAND 2 Moistened sand or gravel spreading with the 2 nd parameter set. SALT Salt spreading. SAND Sand spreading. UPLOAD Material unload. MANUAL Manual mode. CALIBRATION Calibration of tachometer, conveyor/screw, spinner, water pump. PARAMETERS Parameter settings. SPREADER MODEL Selection of operating parameter set from A to H. DAILY DATA Daily operating data (amount of material used, spread amount, kms covered). GLOBAL DATA Global data (amount of material used, spread amount, kms covered). LANGUAGE SELECTION The operator can select between 5 languages. DATE AND TIME Date and time settings. PAGE 5

5.1 MIX-SALT 1 Mode Once the MIX-SALT 1 automatic spreading mode has been selected, the display will visualize the page showed below. It displays the following operating parameters: A. MATERIAL TYPE SELECTED FOR AUTOMATIC SPREADING MODE B. VEHICLE SPEED IN KM/H Connection to GPS step: 0km/h with dark text on blinking light background. Speed automatically detected by GPS: dark text on light background (opposite of the picture above). Manually set speed: light text on dark background (as in the picture above). C. TAIL POSITION Detectable in systems provided with tail shift actuator with potentiometer. D. SPREADING WIDTH IN METERS Value settable with potentiometer #13 between 1 and 12 meters. E. LIQUID PERCENTAGE OF THE TOTAL AMOUNT OF MATERIAL, IN %. Value settable between 0 and 30% with the potentiometer #11. Should the liquid be low, the percentage value is replaced by - - - and the Spread Alarm #19 will blink. F. MATERIAL AMOUNT SELECTED FOR SPREADING IN g/m². Value settable between 5 e 40 g/m² with the potentiometer #10. AUTOMATIC SPREADING While being in one of the following operating modes: MIX-SALT 1 MIX-SAND 1 MIX-SALT 2 MIX-SAND 2 SALT SAND Push the pushbutton #9 to start spreading. If no spreading mode is activated, push the pushbutton to activate it, and vice-versa. Automatic spreading is based upon the vehicle speed detected by the GPS device within the control box. Spreading mode activation is indicated by the Spread On warning light #18 lighting up. - It blinks whenever the spreading mode is active but not working, because the vehicle stopped or the GPS signal is not yet detected. - It lights up whenever the spreading mode is active because vehicle is moving or it has A F B E C D PAGE 6

been set a manual speed. - It is turned off whenever the spreading mode is NOT active (push the pushbutton #9 to activate). Speed detection must be over 5 Km/h for the spreading mode to be working after it has been activated. Spreading depends upon vehicle speed and it is stopped whenever speed falls below 5Km/h. Spreading is resumed without any intervention of the operator whenever vehicle speed exceeds 5Km/h. If the vehicle speed exceeds a maximum limit, the system activates an acoustic alarm (from the buzzer inside the control device) without stopping the spreading mode. Should the detection of the GPS signal fail while spreading, the system utilizes the last correctly detected speed, then after 10 seconds of signal absence, the anomaly is indicated by the alarm condition as follows. WARNING because the vehicle speed is still set to the last detected value, the pushbutton # 9 must be pushed to stop the spreading mode. It is now possible to start spreading with manual speed (see below). Should there be problems of the GPS system detecting speed (e.g. in scarcely covered or not covered areas, like tunnels), speed indication (position #B on the display) will be blinking: at regular and close lapses, it will blink from dark text on light background to light text on dark background. Also the buzzer will beep repeatedly emitting a 1 second lasting sound then it will be silent for 3 seconds, until the GPS signal is detected. In order to spread in areas without any GPS signal, the vehicle speed must be set MANUALLY as follows: - Press for a short time the pushbutton #14 Menu. - The display will visualize the following page (please note that manual speed is ZERO because the saltspreader is automatically set. The operator s intervention is needed to switch to manual mode). - set the required speed (e.g. 40 Km/h) with the two pushbuttons #17 + (to increase the speed value 5 by 5 Km/h) and #16 - ( to decrease the speed value 5 by 5Km/h). In spreading mode with MANUAL speed (manual speed greater than 0), the system starts spreading considering the speed vehicle constant and equal to the input value. In order to spread with the same density as displayed, the vehicle must proceed at the input speed showed on the display. Because the spreading mode now doesn t depend upon the actual vehicle speed, the pushbutton #9 must be pushed to start and stop the spreading mode, e.g. when the vehicle stops at a stop light. Spreading mode activates only if the spinner is not raised, or when the warning light #20 is turned off. When this warning light is on, the spreading is stopped and the relative Spread On warning light #18 is turned off. In order to resume spreading, the spinner must be lowered to its normal operating position and the spreading activation pushbutton must be pushed. The BLAST command is activated by the pushbutton #8 and it is effective only if the spreading mode is active. It forces the material spreading amount to its maximum regardless of vehicle speed and spreading density. Previously set spreading width will not change. The BLAST command allows to spread the material more effectively in dangerous areas or where ice clusters are more likely to appear. The BLAST command is still effective if the spreading have been stopped due to vehicle speed falling below 5Km/h: that is to allow material spreading next to intersections or during vehicle acceleration from stop, i.e. when vehicle starts to move until GPS speed exceeds 5Km/h (where it starts automatic spreading). Note: that intersections are dangerous areas and material spreading should be more abundant. PAGE 7

Operating mode diagnostics MIX-SALT 1 / MIX-SAND 1 / MIX-SALT 2 / MIX-SAND 2 / SALT / SAND By simultaneously holding down the pushbuttons #4 Up and #6 Down it is possible to enter system diagnostic mode. There are 6 diagnostic pages. Browse by pushing the pushbutton #14 Menu. ENGINE ALARMS Engine alarm Alternator alarm Oil pressure alarm Fuel empty alarm 0 = absent 1 = present PUSHBUTTONS Control box push-buttons Push-button position (released/pushed) on the control box 0 = released 1= pushed SPREADER ALARMS Spreading mode alarms Spinner raised alarm No material alarm SIMMETRY SENSOR Tail simmetry actuator stroke Actuator stroke length for tail simmetry 0% = minimum stroke 100% = maximum stroke No liquid alarm 0 = absent 1 = present PROPORTIONAL CURRENTS Proportional current values on the following electro-valves: Conveyor EV RPM of SPEED SENSORS RPM of speed sensors in hydraulic engines RPM CONVEYOR Water pump EV RPM WATER PUMP Spinner EV Current values in ma RPM SPINNER By simultaneously holding down both #4 Up and #6 Down pushbuttons, it is possible to quit diagnostic page and return to the main operating page MIX-SALT 1. PAGE 8

5.2 UPLOAD Mode After selecting the UPLOAD unload mode, the paged showed below will be displayed: A. NOMINAL FLOW OF THE CONVEYOR PROPORTIONAL VALVE (expressed in %) The value can be set between 0 and 100% (i.e. maximum flow) with potentiometer #10. B. NOMINAL FLOW OF THE WATER PUMP PROPORTIONAL VALVE (expressed in %) The value can be set between 0 and 100% with potentiometer #11. In case of low water level, --- will be displayed instead of the percentage value and the warning light #19 will blink. This mode allows to unload the spreading material in a safe and simple way. Unload can be useful when it must be changed the material type or at the end of the season in order to avoid material left in the tank. If the unloading mode is not active, the pushbutton #9 will activate the spreading mode and vice-versa. Unloading mode activation is indicated by the Spread On warning light #18. During the unload, the vehicle speed cannot exceed the top limit of 5km/h. If the vehicle exceeds the speed limit of 5km/h, the material unload will stop and an acoustic alarm will be activated. WARNING: if the stop is caused by exceeding the speed limit, material unloading mode can be resumed by pushing the START pushbutton. It will not be resumed only by the speed falling again below 5km/h. In the unloading mode, the spinner raised alarm is ignored. A B PAGE 9

5.3 MANUAL Mode After selecting the MANUAL operating mode, the following page will be displayed: A. NOMINAL FLOW OF THE CONVEYOR PROPORTIONAL VALVE (expressed in %) The value can be set between 0 and 100% (i.e. maximum flow) with potentiometer #10. B. NOMINAL FLOW OF THE WATER PUMP PROPORTIONAL VALVE (expressed in %) The value can be set between 0 and 100% with potentiometer #11. In case of low water level, --- will be displayed instead of the percentage value and the warning light #19 will blink. C. NOMINAL FLOW OF THE SPINNER PROPORTIONAL VALVE (expressed in %) The value can be set between 0 and 100% with potentiometer #13. This mode allows to control the correct system functioning in a safe and simple way. Manual operating mode can be useful to check the flow rate of the hydraulic parts of the system, e.g. the water pump, the spinner hydraulic engine, and others). If manual spreading is not active, the pushbutton #9 activates it and vice-versa. The activation of the spreading mode is indicated by the Spread On warning light #18. If manual mode is active, vehicle speed will be ignored. OTHER MODES The other operating modes, as: MIX-SAND 1 moistened sand or gravel spreading with the 1 st parameter set. MIX-SALT 2 moistened salt spreading with the 2 nd parameter set. MIX-SAND 2 moistened sand or gravel spreading with the 2 nd parameter set. SALT salt spreading SAND sand spreading Will follow the functioning of the MIX-SALT 1 mode, as showed before in the present user manual. A B C PAGE 10