Im Folgenden finden Sie Informationen zu einem Teil unseres Leistungs- und Serviceportfolios.

Similar documents
Miniature Direct-acting Solenoid Valves. VA01 Series 10mm width

Compact Units for Oil

Chain lubrication, accessories

PTEX extruder pumps.

PS/PSL Centrifugal pumps

PILOT OPERATED SOLENOID VALVES. PC RC06,08,15 Series. Rubber Seal, Sub-base Mounting

PMS Centrifugal pumps

DIRECT OPERATED SOLENOID VALVES. A Series. Metal Seal, In-line Mounting/Sub-base Mounting

Electric Immersion Pumps PT sealless EN

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

5 PORT PILOT OPERATED SOLENOID VALVE. ADEX Valves. A00, A05, A12 Series

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)


Soft Start-up Valve. AV2000/3000/4000/5000 Series

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Fittings and Accessories

PNEUMATIC GRIPPER HI-ROTOR-DRIVEN PNEUMATIC GRIPPER CYLINDER-DRIVEN PNEUMATIC GRIPPER

3/4/5-Port Solenoid Valves Precautions 1 Be sure to read this before handling products.

Series AV2000/3000/4000/5000

Catalog 080-/USA Notes Vacuum Control Valves

Vacuum pump system type

MICRO EJECTORS. Micro ejector single unit (without solenoid valve) ME. Micro ejector with solenoid valve DC24V. Block-off plate ME MA-BP

Conventional specification. External Pilot air specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Two Hand Control Valve

MULTISTAGE MICRO EJECTORS

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

LMP screw pumps for delivery pressures up to 120 bar

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

SOLENOID VALVES, SERIES

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

4 Port Solenoid Valve

Added 100 mm and 150 mm lengths. Actuators 10% Air leakage 20% Air blow 70% Current model

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

4 Port Solenoid Valve

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Series VQ Port Solenoid Valve

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

Vacuum / Release Unit

3 Port Solenoid Valve

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Doc. No.VQ4000V-OMV0001. Solenoid Valve PRODUCT NAME. VQ4000/5000 (Pilot Valve V100) MODEL/ Series

Compact Direct Operated 2/3 Port Solenoid Valve for Water and Air

3 Port Solenoid Valve

Regulator Valve. VEX1 Series

SOLENOID VALVES SERIES

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

Doc. No.VQ1000V-OMM0002-B. Solenoid Valve PRODUCT NAME. VQ1000/2000 Series (PILOT VALVE : V100) MODEL/ Series

Achieves high specs as a key valve for mid-sized actuators. SOLENOID VALVES The powerful and low current 280 series solenoid valves inherited the feat

Coolant valve. SGC/SGH Series

Doc. No.VG300 -OMH0002-B. 3 Port Solenoid Valve PRODUCT NAME. VG342 Series MODEL/ Series

Specifications. Fluid Ambient and fluid temperature ( C)

3 Port Solenoid Valve Direct Operated Poppet Type

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

13 msec (at 500 mm )/18.5 msec (at 1000 mm )

Solenoid Valves JC, JE Series

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

For Pneumatic Piping/Fittings & Tubing Prior to Use

ITVH Series. 3.0 MPa Maximum Supply Pressure High Pressure Electro-Pneumatic Regulator. 3.0 MPa 0.2 to 2.0 MPa. 3 W or less L /min (ANR)*

Exhaust Throttle (Needle) Valve ET

3 Port Solenoid Valve

Throttle (Needle) Valve PP Series

Electronic pressure switch for air

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve

SOLENOID VALVES. HEB series SOLENOID VALVES EA, EB SERIES. (2, 3-port pilot type solenoid valves) 53mm. 10mm

Free position locking flat and compact cylinder UFCD Series

S Y 3 A F NFZD

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Solenoid Valves HJE Series (2, 3, 5-port pilot type solenoid valves)

SOLENOID VALVES SERIES

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Speed Controller High Flow

SOLENOID VALVES SERIES

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

SOLENOID VALVES, SERIES

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

Rotary Actuators Precautions 1 Be sure to read this before handling.

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Direct Operated 3-port solenoid valve

Series VP3145/3165/3185

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Vacuum Switch with LED display

Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

New Products COMPACT PILOT OPERATED SOLENOID VALVE FOR WATER. Lightweight and large flow rate, low power consumption Improved corrosion resistance!

New Concept Connector Type Manifold

Clean Air Module. Digital flow switch Regulator ON/OFF valve Restrictor Filter

Series VKF300 VV061 V100 S070 VQD VKF VK VT VS

1.8 w. 3 Port Solenoid Valve. VT307 Series. Direct Operated Poppet Type. Power consumption. A single valve with various valve functions

Multi-Circuit Rotary Block

Push-In Fitting Type Quick Exhaust Valve

The valve body is prepared in two different colors enabling the user to opt for either of the two according to operational environment.

Transcription:

Im Folgenden finden Sie Informationen zu einem Teil unseres Leistungs- und Serviceportfolios. Sollten Sie hierzu oder zu anderen Produkten Fragen haben, treten Sie jederzeit gern in Kontakt mit uns: Tel: 07-800 info@vogel- gruppe.de Parker Store Komponenten D- Rohrbiege- Service Wartung und Service Hydraulik & Pneumatik Aggregate- und Anlagenbau Mobiler Tag- und Nacht vor- Ort- Service Hauptsitz Senftenberg Laugkfeld, 098 Senftenberg Tel: 07 80-0 Bereitschaft: 00 78 8 E- Mail: senftenberg@vogel- gruppe.de Niederlassung Dresden Niedersedlitzer Str. 7. 07 Dresden Tel:0 79 7 78 Bereitschaft: 00 7 8 8 E- Mail: dresden@vogel- gruppe.de Niederlassung Frankfurt/Oder Wildbahn 8, Frankfurt/Oder Tel: 0 08 Bereitschaft: 00 7 8 8 E- Mail: frankfurt@vogel- gruppe.de Niederlassung Genshagen & Rohrbiegezentrum Seestr. 0, 97 Genshagen Tel: 078 87 90 7 Bereitschaft: 07 90 E- Mail: genshagen@vogel- gruppe.de Niederlassung Köln Dr. Gottfried- Cremer- Allee, 0 Frechen Tel: 0 99-0 Bereitschaft: 0 8 E- Mail: koeln@vogel- gruppe.de Niederlassung Schöneiche August- Borsig- Ring, Schöneiche Tel: 00 9 8 Bereitschaft: 00 7 8 90 E- Mail: schoeneiche@vogel- gruppe.de Industrie- Hydraulik Vogel & Partner GmbH Laugkfeld, 098 Senftenberg, Tel.: 07 80-0 E- Mail: info@vogel- gruppe.de www.vogel- gruppe.de

Miniature Direct-acting Solenoid Valves VA0 Series 0mm width

FOR SAFETY USE Be sure to read the following instructions before use. For common and individual instructions, refer to the text of this catalog. The following safety precautions are provided to prevent damage and danger to personnel and to provide instructions on the correct usage of this product. These precautions are classified into categories; CAUTION, WARNING and DANGER according to the degree of possible injury or damage and the degree of impendence of such injury or damage. Be sure to comply with all precautions along with JIS B870 ( ) and ISO ( ), as they include important content regarding safety. CAUTION : WARNING : DANGER : Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in personal injury or property-damage-only accidents. Indicates a potentially hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death. Indicates an impending hazardous situation which may arise due to improper handling or operation and could result in serious personal injury or death. ( ) JIS B870 : General Rules for Pneumatic Systems ( ) ISO : Pneumatic fluid power-general rules relating to systems WARNING The applicability of vacuum equipment to the intended system should be judged by the pneumatic system designer or the personnel who determined specifications for such system. As operating conditions for products contained in this catalog are diversified, the applicability of vacuum equipment to the intended system should be determined by the pneumatic system designer or the personnel who determined specifications for such system after conducting an analysis or testing as necessary. The system designer shall be responsible for assuring the intended system performance and safety. Before making a system, the system designer should thoroughly examine all specifications for such a system and also take into consideration the possibility of any trouble with the equipment. The vacuum equipment should be handled by persons who have sufficient knowledge and rich experience. Inproper handling of compressed air and vacuum will result in danger. Assembling, operation and maintenance of machinery using vacuum equipment should be performed by persons who have sufficient knowledge and rich experience. Never operate machinery nor remove the equipment until safety is assured. Befor cheking or servicing machinery and equipment, be sure to check that steps for prevention of dropping or runaway of the driven component have been completely taken. When removing the equipment, make sure that the above-mentioned safety measures have been done beforehand. Then turn off air supply and power to the system and purge compressed air in the system. When restarting machinery and equipment, check that proper prevention of malfunction has been provided for and then restart carefully. When using the vacuum equipment in the following conditions or environments, take the proper safety measures and consult KURODA Pneumatics beforehand. Conditions and environments other than specified and outdoor use. Applications to nuclear power equipment, railroads, aircraft, vehicles, medical equipment, equipment connected with food and drink, amusement facilities and safety devices such as emergency interruption devices, clutch/brake circuits for a press and the likes. Applications which require extreme safety and will also greatly affect men and property.

SOLENOID VALVES FOR VACUUM/COMMON INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and instructions mentioned for each series of solenoid valves. DESIGN DESIGN WARNING CAUTION Power failure and trouble of air supply will lead to Use at low temperature vacuum down ; this sometimes results in an accident. When using a solenoid valve at C or below, provide an air dryer or Take a safety measure against such accident. other proper means to prevent moisture from solidifying or If vacuum pad loses its sucking force due to vacuum down, the freezing. workpiece being carried will drop, endangering the human body and Shock and vibration machine. Provide prevention against the drop of a workpiece or take Reduce shocks and vibrations applied to the solenoid valve to a proper safety measure. less than the prescribed value. (refer to specifications.) Do not use for emergency shutoff valves. Applying shocks and vibrations exceeding the prescribed value may Solenoid valves listed in this catalogue are not designed for use in rsult in a malfunction of the solenoid valve. emergency shutoff valves and other safety applications. When using the solenoid valve for such applications, provide an independent means to assure safety. Exhausting residual air Provide a residual air exhausting function in due consideration of maintenance and inspection. Use in vacuum In order to prevent sucking foreign matters from the suction pad and exhaust port, provide an inline filter and air muffler between the suction pad and solenoid valve and at the exhaust port. Applying current continuously for long time When using a solenoid valve while applying current to it continuously for a long period of time, contact KURODA Pneumatics beforehand. Remodeling the solenoid valve Do not remodel the solenoid valve. SELECTION WARNING Check the specifications. Solenoid valves listed in this catalog are designed for vacuum or compressed air. Avoid using other fluid than vacuum or compressed air. Do not use a solenoid valve at any pressure and temperature outside the range of specifications, otherwise resulting in a breakdown or malfunction. CAUTION Leak current When a C-R element is used in the contact protective circuit (surge voltage protection), leak current will flow through the C-R element. If this leak current becomes large, a malfunction will occur. Therefore, reduce leak current to less than ma. C-R circuit Contact Power supply Leak current Solenoid

SOLENOID VALVES FOR VACUUM/COMMON INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and instructions mentioned for each series of solenoid valves. MOUNTING WARNING When mounting the solenoid valve, firmly fix it while using care to prevent the stationary part and joint from loosening. If the solenoid valve is mounted with insufficient strength, it may sometimes come off. Do not start the system until it is ensured that equipment works properly. After mounting the solenoid valve, connect power supply and then perform a functional test and a leak test. Check that it has been correctly mounted and works properly, before starting the system. Coating with paint When coating the resin portion with paint, it may be adversely affected by paint and solvent. For the propriety of painting, contact KURODA Pneumatics beforehand. Do not peel off the nameplate affixed on the solenoid valve and do not erase or smear out the letter on it. Provide space for maintenance and inspection. CAUTION Do not wipe off the model name inscribed on a nameplate etc, with organic solvent. The inscribed indication may be erased. Fit an air muffler to the exhaust port of the solenoid valve. Dust or foreign matter that enters it may cause a malfunction of the solenoid valve. PIPING CAUTION Avoid spiral pipe laying. When spiral pipe laying is used in a vacuum line, it may sometimes delay attaining vacuum due to the resistance of piping or cause vacuum down at the suction end ; resulting in the malfunction of the vacuum sensor. For manifold with solenoid valves, pay attention to piping diameter. When increasing the number of manifold stations, flow may be insufficient according to circumstances. In this case, supply and exhaust air from both sides of the manifold. Before piping Thoroughly flush the inside of each pipe to remove chips, coolant, dust, etc. before piping. How to wind a seal tape When winding a seal tape around the threaded portion, leave space of. to thread turns. Leave space of. to tums. (Good) (No good) How to apply liquid sealant When screwing seal or tape enters equipment, causing air leak. When applying liquid sealant to the threaded portion, apply a proper mount to about / of the periphery of the threaded portion and then screw it. Joint Sealant Apply sealant to this portion. / Avoid wrong piping. When connecting a pipe to each equipment, be careful not to mistake the supply port etc. by referring to the nameplate afixed to the product or the product catalog.

SOLENOID VALVES FOR VACUUM/COMMON INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and instructions mentioned for each series of solenoid valves. PIPING CAUTION Screw of pipe and joint When screwing the pipe and joint, use care to prevent chips and sealant from entering the pipe and joint. Tighten them within a proper range of tightening torque. Port size M M R, Rc /8 R, Rc / APPLICABLE TUBES CAUTION Used nylon tubes or polyurethane tubes made by KURODA Pneumatics for Instant Joints. When using tubes made by other companies, check the diametral accuracy. There are some commercially available tubes that do not satisfy the specified diametral accuracy. Do not extremely bend the tube near the joint ; otherwise resulting in the break or bucking of the tube. When using the tube with it bent, use at more than minimum bend radius. When using with other fluid than air, consult KURODA Pneumatics. CONNECTION AND DISCONNECTION OF TUBE CAUTION Tightening torque (N m) 0.~0..~.0 7.0~9.0 ~ How to connect a tube When using a tube, cut it at right angles axially with the special tool (Tube Cutter/TC-). Cutting it with scissors or nippers to cause a deformation may result in air leak or coming off. Fully insert the tube up to the tube end. Pull the tube lightly and check that it does not come off from the joint. WIRING WARNING When doing wiring work, be sure to turn off compressed air, vacuum and power supplies beforehand. Wiring work without turning off air, vacuum and power supplies may cause an electric shock or malfunction, this sometimes results in an injury to the human body or a domage to property. Avoid mis-wiring. Some solenoid valves have polarity : Those operating on DC with built-in indicator light and those equipped with surge protective circuit. When wiring to a solenoid valve, check whether or not it has polarity. For a solenoid valve having polarity, check the lead wire color and symbol of the polarity by the catalog or actual article beforehand and then make correct wiring. Avoid applying stress and tensile force to lead wire repeatedly. Wiring made in such a manner that stress and tensile force are repeatedly applied to the lead wire will result in the breaking of wire. Provide some degree of margin for wiring. Check that there is no insulation failure. If an insulation failure occurs in the lead wire connection, extension cable and terminal base, an excess flows to the switching element of the solenoid valve or control unit, sometimes resulting in a damage. Do not mistake applied voltage. Mistake in applied voltage in case of wiring to a solenoid valve will cause an operation failure or burn out the coil. After completion of wiring, check for wrong connection before turning on power. Do not supply power at the same time. Do not supply power to both double solenoid type valve and latch type solenoid valve at the same time. How to disconnect a tube Pull out the tube while pushing the release ring in paralle. Before pulling out the tube, be sure to discharge residual pressure. When reusing the disconnected tube, cut off the bitten portion of the tube.

SOLENOID VALVES FOR VACUUM/COMMON INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and instructions mentioned for each series of solenoid valves. OPERATING ENVIRONMENTS DANGER Do not use solenoid valve in a explosive environment. WARNING Do not use a solenoid valve in atmospheres containing corrosive gases, chemicals, seawater, water and vapor and in places where a solenoid valve contacts these matters. Do not use a solenoid valve in a place where vibrations or shocks are directly applied to it. When a solenoid valve is exposed to the direct sunlight, fit a protective cover to the solenoid valve. When a solenoid valve is located around a heat source, shut off the radiant heat. When installing a solenoid valve in the control panel, take proper heat-radiating measures so that the inside temperature may be kept within the specified temperature range. When using a solenoid valve in a place where it is exposed to welding spatters, provide a protective cover or other proper prevention. Welding spaters may burn out the plastic parts of the solenoid valve, sometimes resulting in a fire. QUALITY OF AIR WARNING Use pure air. Compressed air containing corrosive gases, chemicals, salt, etc. causes a breakdown or operation failure. So do not use such air. CAUTION Fit an air filter with filtration of µm or fine. MAINTENANCE AND INSPECTION WARNING Inspection before maintenance First check that load drop prevention has been provided. Then shut off air and power supplies to the system and exhaust residual air in the system beforehand. Inspection after maintenance When restarting the system, check that preventive measures against flying-out of the actuator have been taken. Then connect compressed air supply to the pneumatic system, and perform a proper functional test and a leak test to check that it works safely without fail, before starting the system. Operation at low frequency To prevent an operation failure, perform the switching action of the solenoid valve once per 0 days. (Be careful of air supply.) Manual operation When the solenoid valve is manually operated, the system connected to it is also operated. Make sure safety before operation. Disassembly of solenoid valve When disassembling the solenoid valve, contact KURODA Pneumatics beforehand. Draining CAUTION To keep the quality of air to a certain level, drain the air filter at periodical intervals. Chek and clean the vacuum filter and silencer everyday, and also change the element periodically. Silting will deteriorate the performance. Install an air dryer. Compressed air containing much drainage causes the operation failure of pneumatic equipment. lnstall and air dryer, lower the temperature and reduce drainage. Take proper countermeasures against sludge. If sludge produced in compressor oil enters pneumatic equipment, it will cause the operation failuse of pneumatic equipment. it is recommendable to use compressor oil (NISSEKI FAIRCALL A8, IDEMITSU DAPHUNY SUPER CS8) featuring minimized sludge production or use a coalescing filter to prevent sludge from entering the pneumatic equipment. Filter Coalescing filter Regulator

VA0 SERIES/INDIVIDUAL INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and common instructions. MOUNTING CAUTION When valve is mounted on sub-base or manifold, tighten set screws by the following clamping torque. Valve No. VA0PSV VA0PSP VA0PLV VA0PLP VA0PEPA VA0RDP VA0PSC VA0PLC Screw size M.7 M.7 M ELECTRICAL WAVEFORM Tightening torque (N m) 0.0~0. 0.~0.0 0.~0.0 In order to realize quick response time, electrical waveform of VA0PSV, VA0PSP and VA0PEP A are the following. Voltage Power consumption V 0V W W 0W about00ms SIMULTANEOUS ENERGIZING CAUTION Do not energize terminal and at the same time in case of using latching solenoid valve. Latching solenoid valve has interlock circuit. In case of simultaneous energizing, the switching position is held, however, please note that indicator light is sometimes switched on. For example, if electricity is turned on for terminal (green), and then it is turned on for terminal without turning off for terminal, valve keeps the air way position of terminal side, however, indicator light of terminal (red) side might be switched on. In this case, turn off electricity for terminal and indicator light of terminal side will be switched on. CONTINUOUS ENERGIZING WARNING Do not energize continuously for long time to VA0PS / (standard) and VA0PL /. In case of continuous energizing to the valve or continuous operating in short tact time, solenoid will generate heat, and seal and gasket will be damaged. Therefore, air leak or wrong operation might be caused. If continuous energizing or continuous operating in short tact time operation is necessary for those valves, please contact KURODA Pneumatics. CAUTION Latching solenoid valve requires no continuous supply of power. After switching by pulse signal, that position is held until reverse direction signal is input. However, set input signal at minimum required energizing time (0ms) or over. VACUUM BREAK ON VA0PEPA CAUTION Vacuum break with low air pressure If operating pressure is less than 0.0MPa, enough vacuum break pressure will not output because of air leakage from atmospheric release port. (VA0PEPA type valve has atmospheric release port, and leakage from atmospheric release port is originally on the assumption.) KEEPING VACUUM PRESSURE CAUTION The solenoid valve cannot keep vacuum pressure for a long period of time when electricity is OFF. As the solenoid valve is designed to allow a certain small degree of air leak, it cannot be used to keep vacuum pressure for a long period of time during electrical power is not supplied to the valve. 7

VA0 SERIES/INDIVIDUAL INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and common instructions. WIRING SPECIFICATIONS L type Lead wire (AWG length 00 mm) CAUTION Make connection by adjusting polarity to to signs on the lamp cover. VA0PL, VA0PLC/RLC NPN type Black ( ) and P type Connector with lead wire (AWG length 00 mm), side outlet (with indicator light & surge suppressor) Driver circuit Red (+COM) Yellow ( ) U type Connector with lead wire (AWG length 00 mm), upside outlet (with indicator light & surge suppressor) PNP type Driver circuit Black (+) Red ( COM) Yellow (+) INTERNAL CIRCUIT OF P & U TYPE VA0PSP/VA0PSV/VA0PEPA VA0PSC/VA0RDP Red Red Driver circuit Black Black VA0HPSC Red Black 8

VA0 SERIES/INDIVIDUAL INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and common instructions. RELATION BETWEEN INPUT ELECTRIC SIGNAL AND VALVE OUTPUT CAUTION Relation between input electric signal and valve output is as follows : Latch SOL coil <Power supply and connection of solenoid valve> VA0PL Power is supplied to red (+) lead wire and yellow ( ) lead wire. Port will be closed. Power is supplied to red (+) lead wire and black ( ) lead wire. Air way is connected between port and port. VA0PLC/RLC Control circuit Black ( ) Red (+) COM Yellow ( ) Light green indicator light Light red indicator light Power is supplied to red (+) lead wire and yellow ( ) lead wire. Air way is connected between port and port, and port and port /. / Light green indicator light Power is supplied to red (+) lead wire and black ( ) lead wire. Air way is connected between port and port, and port and port /. / Light red indicator light MANUAL OPERATION CAUTION If valve is manually operated, the application will be started. Confirm that there is no problem or danger on the application before manual operation of valve. VA0PL valve is switched the air way position by the following manual operation. Push blue manual button on the valve body. Port will be closed. Push white manual button on the valve body. Air way is connected between port and port. VA0PLC/RLC valve is switched the air way position by the following manual operation. Push manual button "a" (blue) on the valve body. Air way is connected between port and port, and port and port /. / Push manual button "b" on the valve body. Air way is connected between port and port, and port and port /. b / a 9

VA0 SERIES/INDIVIDUAL INSTRUCTIONS Be sure to read them before use. Also refer to Par. "For Safety Use" and common instructions. OPERATING PRINCIPLE OF LATCH TYPE SOLENOID VALVE Supplying power to Control Circuit Supplying power to Control Circuit When turning on Contact A and supplying power to Control Circuit, force FA is generated to separate the movable iron core from the fixed iron core. Force to which spring force f is added exceeds the attractive force FM of the permanent magnet, thereby separating the movable iron core from the fixed iron core by the force of F=FA+ f FM. No supplying power to Control Circuit When turning off Contact A with the movable iron core separated from the fixed iron core, the movable iron core holds that state by spring force f. B A When turning on Contact B and supplying power to Control Circuit, force FB is generated to attract the movable iron core to the fixed iron core. Force to which the attractive force FM of the permanent magnet is added exceeds the spring force, and thus the movable iron core is attracted to the fixed iron core by the force of F=FB+FM f. No supplying power to Control Circuit When turning off Contact B with the movable iron core attracted to the fixed iron core, the movable iron core is kept attracted by the permanent magnet. B A f COM Control circuit FA Permanent magnet CA f COM Control circuit CB FB F FM F FM Spring Movable iron core Coil Fixed iron core 0

For vacuum and positive pressure control/ blow off operation Miniature size -port -position direct-acting solenoid valve VA0PSV for vacuum VA0PSP for positive pressure Miniature size -port -position direct-acting latching solenoid valve VA0PLV for vacuum VA0PLP for positive pressure VA0PSV VA0PSP VA0PLV VA0PLP : Vacuum supply port : Output port : Atmospheric release port : Pressure port : Output port : Exhaust port Two types of models for vacuum control (white body) and positive pressure (black body) Easy to figure out vacuum control or positive pressure valve from valve body color. Ultra quick response time Response time of latch type solenoid is ms and single solenoid is ms for turning on. Reliable stable operation is available. (VA0PSV-_R/VA0PSP -_R) Renewal electric circuit make response time up. Valve react high response by order. Low power consumption New single solenoid valve mount low energy circuit and low power consumption is realized. Hold is W (Inrush: W). Keep the solenoid heat as low temperature and apply continuous energizing. Compact valve is large flow (Cv 0.0). Compact, light weight and large flow Very compact plastic body in 0mm width, weighting only g. (with sub-base) Light and compact valve contribute for compact and light unit when valves are mounted on mounting head. Oil free type is standardized. Extremely low particle. The original poppet structure, which as no friction parts without lubricating oil, realizes the extremely low particle from the valve. One coil latch type solenoid Newly developed one coil latch type solenoid is incorporated! Detent mechanism to hold switching position with permanent magnet in one coil solenoid assures safety operations such as keeping suction by vacuum.

Miniature size -port -position direct-acting solenoid valve for vacuum VA0PS/LV for vacuum VA0PS/LP for vacuum break (positive pressure) Poppet seal/sub-base piping type Specifications Model No. Fluid Port size Sonic conductance (C) Effective area (Reference) Cv value (Reference) Pressure range Ambient temperature Response time Min. energizing time Shock resistance/vibration resistance Mass ON OFF Unit dm (s bar) mm C ms ms ms m/s g VA0PSV Vacuum 0..0 0.0 00~0kPa VA0PSP Non-lubricated air M 0. 0. 0.0 0~0.MPa 0~0 0/0 VA0PLV Vacuum 0..0 0.0 00~0kPa ~0 0 0/0 0 VA0PLP Non-lubricated air 0. 0. 0.0 0~0.MPa (Note) When using the valve for vacuum break at less than C by supplying compressed air, use dry air passing through an air dryer to prevent dew condensation and freezing. Electrical Specifications Model No. Unit Rated voltage V Allowable voltage fluctuation % Heat resistance grade Power consumption W Wiring g VA0PSV VA0PSP VA0PLV VA0PLP DC ±0 JIS grade B (Holding), (Inrush) Lead wire, connector with lead wire Connector with lead wire

Ordering instruction Miniature size -port -position direct-acting solenoid valve Solenoido valve VA0 PSV L L Function PSV : position single solenoid/for vacuum :Vacuum supply port :Output port :Atmospheric release port PLV : position latching solenoid/for vacuum :Vacuum supply port :Output port :Atmospheric release port PSP : position single solenoid/for vacuum break :Pressure port :Output port :Exhaust port PLP : position latching solenoid/for vacuum break :Pressure port :Output port :Exhaust port Voltage DCV Wiring specifications Case of VA0PS L Lead wire Connector with lead wire, Side outlet PR (With indicator light & surge suppressor) Connector with lead wire, Upside outlet UR (With indicator light & surge suppressor) Case of VA0PL NPN type Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) PNP type Connector with lead wire, Side outlet PM (With indicator light & surge suppressor) Connector with lead wire, Upside outlet UM (With indicator light & surge suppressor) Wiring accessories No mark Without connector Connector with lead wire E (Length : 00mm) Port size No mark L Without sub-base (Sub-base with mounting screw hole, M) (Note) Model without sub-base is provided with mounting screws and a base gasket. Manifold MFS V0 V CC M Number of stations stations Port size M 0 0stations Type of valve V P V for vacuum P P P for positive pressure Manifold specifications CC Common SUP, common EXH Blank plate (with screws and a gasket) Model No. V-BP Connector with lead wire Lead wire length 000mm 000mm 000mm PSV/PSP PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 Model No. PLV/PLP PCL-D-CL (Standard) PCL-D-CL0 PCL-D-CL0

Miniature size -port -position direct-acting solenoid valve Ordering instruction (Unit : mm) VA0PS - E-L (Sub-base with mounting screw hole, M). Port Output port. VA0PSV :Vacuum supply port :Output port :Atmospheric release port VA0PSP Manual button. :Pressure port :Output port :Exhaust port 0.. -. (Mounting hole).9 Lead wire length 00 AWG 0. Port Atmospheric release port/ Exhaust port 0.. Port Vacuum port/pressure port..7 L type.9 Lead wire length 00 AWG 8. Lead wire length 00 AWG 7.8 P type U type

Miniature size -port -position direct-acting solenoid valve Dimensions (Unit : mm) VA0PL - E-L (Sub-base with mounting screw hole, M). Port Output port. VA0PLV : Vacuum supply port : Output port : Atmospheric release port Manual button Manual button Black VA0PLP 0.. : Pressure port : Output port : Exhaust port. -. (Mounting hole) Red COM Yellow. Lead wire length 00 AWG. Port Atmospheric release port/ Exhaust port 0. Port P type. Vacuum port/pressure port..7 9. Lead wire length 00 AWG 7.9 U type

Miniature size -port -position direct-acting solenoid valve Dimensions Manifold (Unit : mm) MFS V0 Lead wire length 00 AWG Lead wire length 00 AWG Port Vacuum port/ Pressure port 7 0 7.. 0..9 9 0.. 0 9..9.8 Port Atmospheric release port /Exhaust port 9... (B) ().. (A) -. (Mounting hole) VA0PLP(V)-P VA0PSP(V)-L Port n- Output port Blank plate V-BP 8.. 7. VA0PSP(V)-PR n 7 8 9 0 A.. 7 77. 88 98. 09 9. B 7. 8 8. 9 9. 80 90. 0. n : Number of stations Lead wire length 00 AWG 9.9. VA0PLP(V)-U VA0PSP(V)-UR

For vacuum, positive pressure control/blow off operation and air cylinder control operation Miniature size -port -position direct-acting solenoid valve VA0PSC Single solenoid, Sub-base piping type VA0PLC Latching solenoid, Sub-base piping type VA0RSC Single solenoid, In-line piping type VA0RLC Latching solenoid, In-line piping type VA0PSC/RSC VA0PLC/RLC Exceedingly long life. 00 million cycles. (Under the test condition of KURODA Pneumatics.) The reliable double poppets structure, which has the reliance over many years in PC series is applied. Ultra quick response time/stable operation Balanced poppets and direct solenoid mechanism make it available for quick and stable response time. (Latch solenoid type: ON/OFF ±ms, Single solenoid type: ON/OFF ±ms (VA0HPSC). Under the test condition of KURODA Pneumatics.) Compact/Light weight/large flow Compact valve (Body width 0mm) is possible to operate large flow (C value 0.dm /(s bar). Furthermore, resin body (Sub-base type) realizes light weight. (Single solenoid type with sub-base:.g) Both vacuum and positive pressure are available. Balanced poppets structure operates both vacuum and positive pressure ( 00kPa~0.8MPa) in one valve. Oil free is standardized, and extremely low particle. Clean!! Double poppets structure, which has no friction parts without lubricating oil, realizes the extremely clean air blow. Furthermore, the direct operated solenoid has no valve breathing and pilot air exhaust, and the valve does not pollute outside environment. One coil latch type solenoid Newly developed one coil latch type solenoid realizes more compact valve body. (0% less volume. Ratio of KURODA Pneumatics) Detent mechanism, which holds the air switching positions by permanent magnet, is ideal for keeping vacuum position in case of power cut. 7

-port -position direct-acting solenoid valve VA0PSC/PLC Poppet seal/sub-base piping type Specifications Model No. Fluid Port size Sonic conductance (C) Critical pressure ratio Effective area (Reference) Cv value (Reference) Ambient temperature Pressure range Response time ON OFF Manual override Min. energizing time Mounting position Shock resistance/vibration resistance Mass Unit dm /(s bar) mm C ms ms m/s g VA0PSC VA0HPSC VA0PLC. (.) Non-lubricated air M 0. 0. () (0.0) ~0 00kPa~0.8 MPa. Non-lock type push button Free 0/0 0..0 (Note) Sonic speed conductance, critical pressure ratio, effective area and Cv value shown above are value between port and. When temperature of valve site gose down below C, complete dry air shall be supplied to prevent from freezing. Responce time in bracket ( ) shows with surge suppressor. Electrical Specifications Model No. Rated voltage Allowable voltage fluctuation Power consumption Heat resistance grade Unit V % W VA0PSC VA0HPSC DC ±0 JIS grade B VA0PLC Wiring Surge suppressor Lead wire, Connector with lead wire Diode Connector with lead wire Varistor Indicator light LED (Note) Surge suppressor and indicator light are not available for Lead wire type. 8

Ordering instruction -port -position direct-acting solenoid valve VA0PSC PE M Function VA0PSC : Standard VA0HPSC : Quick response VA0PLC : Standard Voltage DCV / / Wiring specifications Case of VA0PSC, VA0HPSC L Lead wire Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) Case of VA0PLC NPN type Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) PNP type Connector with lead wire, Side outlet PM (With indicator light & surge suppressor) Connector with lead wire, Upside outlet UM (With indicator light & surge suppressor) Wiring accessories No mark Without connector Connector with lead wire E (Length:00mm) Port size No mark M M L Without sub-base Without sub-base, M 0. body ported for manifold MFU type only (Sub-base with mounting screw hole, M) (Sub-base with mounting screw hole, M) Connector with lead wire Lead wire length 000mm 000mm 000mm PSC PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 Model No. PLC PLC-D-CL (Standard) PLC-D-CL0 PLC-D-CL0 Constructions VA0PSC VA0PLC Main components No. 7 8 9 0 Description Body Poppet ass'y Manual override Manual override Solenoid ass'y Sub-base Valve seat E Valve seat S Spring V Spring Base gasket Material Synthetic resins Copper alloy Synthetic resins Aluminium alloy Copper alloy Copper alloy Stainless steel Stainless steel NBR+Stainless steel 9

-port -position direct-acting solenoid valve Dimensions VA0PSC- E-M, VA0HPSC- E-M (Sub-base with mounting screw hole, M) (Unit : mm) 0 Port Port.. 0 -. (Mounting hole) 0. Lead wire length 00 AWG. 7.. P type Port / 8.7 7. Lead wire length 00 AWG 0. / Port 0 7. Lead wire length 00 AWG L type U type 0

Dimensions -port -position direct-acting solenoid valve VA0PSC- E-L, VA0HPSC- E-L (Sub-base with mounting screw hole, M) (Unit : mm). 9 Port. 0 -. (Mounting hole) 0. Lead wire length 00 AWG 7. 0. 0 P type 7. Lead wire length 00 AWG 0 Port Port / / 9. 7. Lead wire length 00 AWG. Port 7 L type U type

-port -position direct-acting solenoid valve Dimensions VA0PLC- E-M (Sub-base with mounting screw hole, M) (Unit : mm) 0 Port Port Black.. 0 Red COM -. (Mounting hole) Yellow 0 Manual button 0. Manual button Lead wire length 00 AWG. 7. / Port 0. P type Port / 8.7 Lead wire length 00 AWG 0. U type

Dimensions -port -position direct-acting solenoid valve VA0PLC- E-L (Sub-base with mounting screw hole, M) (Unit : mm). 9 Port 0 Port Black. 0 Red COM -. (Mounting hole) Yellow 0 Manual button 0. Manual button Lead wire length 00 AWG 7. 0. 0 P type Port / / Port Lead wire length 00 AWG. 9. 7 U type

Individual Wiring Type Manifold MF -V0 Manifold specifications Type of manifold MFS Common SUP, Common EXH Ports & on side MFD Common SUP, Common EXH Ports & on side Port M (Both sides) Rc/8(Both sides) Rc/ (One side) Port size Port / M (Both sides) Rc/8(Both sides) Rc/ (One side) Port, M M M Number of stations ~0 Mountable solenoid valve Blank plate VA0PSC VA0HPSC VA0PLC PC-BP Ordering instruction Manifold MFS 0 V0PV CC M Type of manifold Port, Manifold body side ported MFS (Ports, / on both sides) Manifold body side ported MFD (Ports, / on one side) Number of stations station 0 0 station Mountable solenoid valve V0PV VA0 series Manifold specifications CC Option No mark B Common SUP, Common EXH Standard With bracket Port size of port, M M 0. (Only MFS) M Blank plate (with screws and a gasket) Model No. V-BP Ordering information To order the valves with the manifold, use the notation described on the right. Specify model numbers and quantities for manifold and valves. [Example] MFS-V0PVCC-M VA0PSC-P pcs. VA0PLC-P pcs.

Ordering instruction -port -position direct-acting solenoid valve Mountable solenoid valve VA0PSC P E Function VA0PSC : Standard VA0HPSC : Quick response VA0PLC (Standard) Voltage DCV / / Wiring Case of VA0PSC, VA0HPSC L P U Lead wire (For VA0PSC) Connector with lead wire, Side outlet (With indicator light & surge suppressor) Connector with lead wire, Upside outlet (With indicator light & surge suppressor) Case of VA0PLC NPN type Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) PNP type Connector with lead wire, Side outlet PM (With indicator light & surge suppressor) Connector with lead wire, Upside outlet UM (With indicator light & surge suppressor) Wiring accessories No mark Without connector Connector with lead wire E (Length:00mm) Connector with lead wire Lead wire length 000mm 000mm 000mm PSC PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 Model No. PLC PLC-D-CL (Standard) PLC-D-CL0 PLC-D-CL0

-port -position direct-acting solenoid valve Dimensions MFS -V0PVCC(B)-M (Unit : mm) -. (Mounting hole) 8 0. 7. 0. Port - (Opposite side Plugged) 0.... A B. () 0. 9.. 0 / Port / - (Opposite side Plugged) 0 8.. 00 00 Blank plate (V-BP) VA0PLC-P VA0PSC-P VA0HPSC-P Mounting bracket B 7.. 9.. 9 7. 0.. 0. 0. Port M 0.. 00. 00 Port M 0. VA0PLC-U VA0PSC-U VA0HPSC-U VA0PSC-L 00 7. n 7 8 9 0 A B n A B 7 7 8 7 8 7 9 0 8 9 7 8 9 0 8 9 0 9 0 0 n:number of stations

-port -position direct-acting solenoid valve Dimensions MFS -V0PVCC-M (Unit : mm) 0 Port Rc/8. A B 0 9 Port/ Rc/8 0. (Mounting hole) / 7 Blank plate (V-BP) VA0PLC-P Lead wire length00 AWG VA0PSC-P VA0HPSC-P Lead wire length00 AWG Port Rc/8 0 9 Port/ Rc/8 Port n M 7. 9... 0. VA0PSC-L Lead wire length 00 AWG 0. 0. Port n M 7.7 VA0PLC-U 7.7 VA0PSC-U VA0HPSC-U 7. n 7 8 9 0 A 7 8 9 0 B 7 8 9 0 n:number of stations n 7 8 9 0 A 7 8 9 0 B 7 8 9 0 7

-port -position direct-acting solenoid valve Dimensions MFD -V0PVCC(B)-M (Unit : mm). 0. 9... -. (Mounting hole). 0. 9. A B 9.. 9.. 0 8. 7. 7. 00 VA0PLC-U 7. 00 VA0PSC-U VA0HPSC-U 7. n A B n A B 7 8 7 8 7 8 9 0 7 8 9 7 8 9 0 7 8 9 9 0 9 0 0 0 00 / Port Rc/.. Port / Rc/ 00 VA0PLC-P 00 VA0PSC-P VA0HPSC-P Blank plate (PC-BP) -. (Mounting hole) 9. B 9. Mounting bracket. 7.. 9 0... 0 0. Port Port 0. n:number of stations 0 VA0PSC-L 8

-port -position direct-acting solenoid valve VA0RSC/RLC Poppet seal/in-line piping type Specifications Model No. Fluid Port size Sonic conductance (C) Critical pressure ratio Effective area (Reference) Cv value (Reference) Ambient temperature Pressure range Response time ON OFF Manual override Min. energizing time Mounting position Shock resistance/vibration resistance Mass Electrical Specifications Model No. Rated voltage Allowable voltage fluctuation Power consumption Heat resistance grade Wiring Surge suppressor Indicator light Unit dm /(s bar) mm C ms ms m/s g Unit V % W VA0RSC. (.) VA0HRSC VA0RLC Non-lubricated air M 0. 0. () (0.0) ~0 00kPa~0.8 MPa. Non-lock type push button 0 Free 0/0. 8.9 (Note) Sonic speed conductance, critical pressure ratio, effective area and Cv value shown above are value between port and. When temperature of valve site gose down below C, complete dry air shall be supplied to prevent from freezing. Responce time in bracket ( ) shows with surge suppressor. (Note) Surge suppressor and indicator light are not available for Lead wire type. VA0RSC VA0HRSC VA0RLC DC ±0 JIS grade B Lead wire, Connector with lead wire Connector with lead wire Diode Varistor LED 9

-port -position direct-acting solenoid valve Ordering instruction VA0RSC PE M B Function VA0RSC : Standard VA0HRSC : Quick response / VA0RLC : Standard / Voltage DCV Wiring specifications Case of VA0RSC,VA0HRSC L Lead wire (For VA0PSC) Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) Case of VA0RLC NPN type Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) PNP type Connector with lead wire, Side outlet PM (With indicator light & surge suppressor) Connector with lead wire, Upside outlet UM (With indicator light & surge suppressor) Wiring accessories No mark Without connector Connector with lead wire E (Length:00mm) Port size M M 0. Option No mark Standard B With mounting bracket Connector with lead wire Lead wire length 000mm 000mm 000mm RSC PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 Model No. RLC PCL-D-CL (Standard) PCL-D-CL0 PCL-D-CL0 Constructions VA0RSC Main components No. 7 8 9 0 Description Body Poppet ass'y Manual override Manual override Solenoid ass'y Valve seat E Valve seat S Spring V Spring Material Aluminium alloy Copper alloy Synthetic resins Copper alloy Copper alloy Stainless steel Stainless steel VA0RLC 0

-port -position direct-acting solenoid valve Dimensions VA0RSC, VA0HRSC (Unit : mm). Port /.7 7 Port M 0. -M 0. depth. Mounting bracket.. 8 0 Port M 0. Port M 0. 0. 0. Lead wire length AWG 7. 7. Lead wire length 00 AWG 0. 7.8 8.. -. (Mounting hole) 0 P type Lead wire length 00 AWG 7. L type U type

-port -position direct-acting solenoid valve Dimensions VA0RLC (Unit : mm). Port /.7 7 Port M 0. -M 0. depth. Mounting bracket. 8 0. Manual button Manual button Black Port M 0. Port M 0. Red COM Yellow 0 0. 0. Lead wire length 00 AWG 7.8 8.. Lead wire length 00 -. (Mounting hole) AWG 7. 0 P type U type

Most suitable for vacuum and vacuum break in vacuum pump lines! -port -position direct-acting solenoid valve for vacuum and vacuum break VA0RDP : Positive pressure supply port : Output port : Vacuum supply port Light weight and compact Body width 0 mm, weight g One unit works for both vacuum control and vacuum break controls. Vacuum control valve and vacuum break control valve (pressure : 0. MPa max.) are united. Holds vacuum at intermediate position Solenoid valve returns to intermediate position at the time of power failure and emergency stop, and holds attraction with vacuum pad. Quick response time ms response time and stable action at the time of turning on/off Needle valve for vacuum break flow control Air flow for vacuum break can be controlled according to work by a needle valve in the flow path for vacuum break. Manifold is available Vacuum port for common or individual manifolds are available up to 0 stations. Manifold with Needle valve for vacuum flow control Vacuum flow can be controlled according to work by a needle valve in the flow path to each solenoid valve in the manifold. Needle valve for vacuum break flow control Needle valve for vacuum flow control

-port -position direct-acting solenoid valve VA0RDP Poppet seal/in-line piping type Ordering instruction Specifications Model No. Fluid Port size Flow Pressure range Vacuum Vacuum break Vacuum Vacuum break Ambient temperature Response time Rated voltage Allowable voltage fluctuation Heat resistance grade Power L type consumption P, U type Wiring Vibration resistance/shock resistance Mass Unit R/min (ANR) R/min (ANR) kpa MPa C ms V % W W m/s g for vacuum and vacuum break VA0RDP Air M 0 at 90kPa (Port ) 8at0.MPa (Port ) ON : or less 00~0 0~0. 0~0 OFF : (0) or less DC ±0 JIS grade B 0. 0. Lead wire, connector with lead wire 0/0 (Note) When using the valve for vacuum break at less than C by supplying compressed air, use dry air passing through an air dryer to prevent dew condensation and freezing. Response time in bracket ( ) shows with surge suppressor. Solenoid valve Manifold VA0 R DP - L - M - MFU - V0R CC V - M Type of piping R In-line piping Function -position closed center DP Double solenoid Voltage DCV Wiring specfications Bipolar type L Lead wire Connector with lead wire, Side outlet P (With indicator light & surge suppressor) Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) Wiring accessories No mark No connector Connector with lead wire E (Length : 00 mm) Port size M For mounting manifold For mounting manifold MF (With mounting screws, gasket) Blank plate (with screws and a gasket) Model No. V-BP Number of stations stations : : 0 0 stations Manifold specifications CC CI Port size M Common (Positive prssure), Common (Vacuum) Common (Positive prssure), Individual (Vacuum) Needle valve for vacuum flow control No mark No needle valve Needle valve for vacuum flow control V (Only for CC specfication) (Note) Solenoid valve with needle valve for vacuum flow control is to be made to order. Connector with lead eire Lead wire length 000mm 000mm 000mm Model No. PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 CAUTION Use positive pressure for port within pressure range of 0 to 0. MPa. Do not supply vacuum pressure. Use vacuum pressure for port within pressure range of 00 to 0 kpa. Do not supply positive pressure.

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions VA0RDP (Unit : mm) 7. Port Output port 9...8 (Mounting hole) : Positive pressure supply port : Output port : Vacuum supply port Manual button (Vacuum side) Manual button (Positive pressure side) Needle valve for vacuum break flow control 7 Lead wire length 00 AWG MAX MIN.. 9. 7. 0. -. (Mounting hole) L type 0 Port Vacuum supply port Port Positive pressure supply port.. 89 Lead wire length 00 AWG P type 7.8 7.8.8 Lead wire length 00 AWG 7 U type

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions Manifold (Unit : mm) MFU -V0RCC-M MAX MIN 8. 8. A B (.) Circuit diagram 0 -. (Mounting hole) Port Rc!/8 Positive pressure supply port 0.. 8. Port Rc!/8 Vacuum supply port. Blank plate V-BP 7. 7. Needle valve for vacuum break flow control 7. 0. Port n- Output port. Lead wire length 00 AWG MFU -V0RCCV-M (Order made) 7. 0. Needle valve for vacuum flow control MAX MIN 8. Circuit diagram 0. 7. 8. A B (.) MAX8. MIN. 0. -. (Mounting hole) Port Rc!/8 Positive pressure supply port 8. 7 7 L type Port Rc!/8 Vacuum supply port. 7. 7. Throttle valve for vacuum break flow control Port n- Output port. L type Lead wire length 00 AWG 7. 0.

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions Manifold (Unit : mm) MFU -V0RCI-M 7. 0. Port n- Vacuum supply port 7. MAX MIN8. 8. A B (.) Circuit diagram -. (Mounting hole) Port Rc!/8 Positive pressure supply port 7.. 8. 0 Blank plate V-BP 7 7.. Needle valve for vacuum break flow control Lead wire length 00 AWG 7. 0. Port n- Output port L type 0.8 (Overall height) P type 89 (Overall length) Lead wire length 00 AWG n 7 8 9 0 A.. 7 8. 9 0.. 7 (overall length) B 8. 9 9. 0 70. 8 9. 0. n : Number of stations.8 (Overall height) Lead wire length 00 AWG U type 7

Most suitable for vacuum and vacuum break of very small work! -port -position direct-acting solenoid valve for vacuum and vacuum break VA0PEPA Y Solenoid A side Solenoid B side : Positive pressure supply port : Output port : Vacuum supply port Y : Atmospheric release port Light weight and compact Body width 0 mm, weight g One unit works for both vacuum control and vacuum break controls. Vacuum control valve and vacuum break control valve (pressure : 0.MPa max.) are united. Quick response time ms response time and stable action at the time of turning on/off. Needle valve for vacuum break flow control Air flow for vacuum break can be controlled according to work by a needle valve in the flow path for vacuum break. Atmospheric release mechanism It serves to release the suction side pressure to the atmospheric air once and then supply air for vacuum break, when doing vacuum break from the vacuum state. This feature will be highly effective for loading and unloading very small work quickly in a stable state. Manifold is available Vacuum port for common or individual manifolds are available up to 0 stations. To customers having the following problemes in pick and place very small work ; Parts around vacuum-breaking air are blown off, when work is detached. Timing of detaching work tends to vary. Re-sacking occurs after work is detached. Two solenoid valves are required to set up an atmospheric release circuit. Using VA0PEPA will cut down these problems. Atmospheric pressure Vacuum Example where no atmospheric releasing mechanism is used Pressure Solenoid valve for vacuum break : ON Vacuum pressure varies. Breaking time varies. Solenoid valve for vacuum break : OFF Blowing off by overshoot of breaking pressure Time Atmospheric pressure Vacuum Example where atmospheric releasing mechanism is used Pressure Solenoid A side OFF (Intermediate position) Atmospheric release Solenoid B side ON Vacuum pressure varies. Solenoid B side OFF Reduces overshoot. Reduces variation of breaking time by atmospheric release. Time 8

-port -position direct-acting solenoid valve VA0PEPA Poppet seal/sub-base piping type for vacuum and vacuum break Ordering instruction Solenoid valve Specifications Model No. Fluid Port size Flow Pressure range Vacuum Vacuum break Vacuum Vacuum break Ambient temperature Response time Rated voltage Allowable voltage fluctuation Heat resistance grade Power consumption Wiring Vibration resistance/shock resistance Mass Unit R/min (ANR) R/min (ANR) kpa MPa C ms V % W m/s g VA0PEPA Air M 0 at 00kPa (Port ) at 0.MPa (Port ) ON : or less 00~ 0 0.0~0. 0~0 DC ±0 JIS grade B OFF : or less (Holding), (Inrush) Lead wire, connector with lead wire 0/0 (Note) When using the valve for vacuum break at less than C by supplying compressed air, use dry air passing through an air dryer to prevent dew condensation and freezing. Manifold VA0 P EP A - U - M - MFS - V0P CC - M 7 Type of piping P Sub-base piping Function -position with atmospheric release EP mechanism Double solenoid Voltage DCV Wiring specfications Connector with lead wire, Upside outlet U (With indicator light & surge suppressor) Wiring accessories No mark No connector Connector with lead wire E (Length : 00 mm) Port size No mark No sub-base M M 0.8 (Note) Model without sub-base is provided with mounting screws and a base gasket. 7 Option No mark No option Atmosheric release port F with filter Filter for atmospheric lelease port Model No. V-F Blank plate (with screws and a gasket) Model No. V-BP Number of stations stations : : 0 0 stations Manifold specifications CC Common (Positive prssure), Common (Vacuum) CI Common (Positive prssure), Individual (Vacuum) Port size M M 0.8 Connector with lead wire Lead wire length 000mm 000mm 000mm Model No. PC-D-CL (Standard) PC-D-CL0 PC-D-CL0 CAUTION Use positive pressure for port within pressure range of 0.0 to 0. MPa. Do not supply vacuum pressure. Use vacuum pressure for port within pressure range of 00 to 0 kpa. Do not supply positive pressure. 9

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions VA0PEPA (Unit : mm) Port Vacuum supply port Port Positive pressure supply port 7 Y : Positive pressure supply port : Output port : Vacuum supply port Y : Atmospheric release port 7 Lead wire length 00 AWG 7 7.8... 0 8 Atmospheric release port -. (Mounting hole) Manual button (Vacuum side) Needle valve for vacuum break flow control Manual button (Positive pressure side) 7 MAX7 MINI. 8. Port Output port Atmospheric release port with fiter Atmospheric release port with filter "V-F". (Option) 0

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions Manifold (Unit : mm) MFS -V0PCC-M Circuit diagram Port - Vacuum supply port (Opposit side plugged) MAX MIN8. 7. A B () (.) Atmospheric release port.8. Port - Positive pressure supply port (Opposit side plugged) 8 Needle valve for vacuum break flow control 7 0.7 9. Lead wire length 00 AWG. -. (Mounting hole) Blank plate V-BP 7 8.. Port n- Output port... 0. n 7 8 9 0 A 9. 0 0. 7 8. 9 0.. B.. 7. 8 9. 0. n : Number of stations

-port -position direct-acting solenoid valve for vacuum and vacuum break Dimensions Manifold (Unit : mm) MFS -V0PCI-M Circuit diagram 7.. 0. Port n- Vacuum supply port MAX MIN8. A (). B (.) Atmospheric release port 7.8 Port - Positive pressure supply port (Opposit side plugged) 8. Needle valve for vacuum break flow control 7 0.7 9. Lead wire length 00 AWG. -. (Mounting hole) Blank plate V-BP 7 8 Port n- Output port n 7 8 9 0 A 9. 0 0. 7 8. 9 0.. B.. 7. 8 9. 0.... 0. n : Number of stations

For vacuum, positive pressure control/blow off operation and air cylinder control operation Miniature size -port -position direct-acting solenoid valve VA0PSC Single solenoid, Sub-base piping type VA0RSC Single solenoid, In-line piping type VA0PSC/RSC Compact Large flow Compact valve (Body width mm) is possible to operate large flow (C value 0.7dm /(s bar). Quick response time/stable operation Balanced poppets and direct solenoid mechanism make it available for quick and stable response time. Single solenoid type: ON.ms/OFF ms. Under the test condition of KURODA Pneumatics.) Oil free is standardized, and extremely low particle. Clean!! Double poppets structure, which has no friction parts without lubricating oil, realizes the extremely clean air blow. Furthermore, the direct operated solenoid has no valve breathing and pilot air exhaust, and the valve does not pollute outside environment. Both vacuum and positive pressure are available. Balanced poppets structure operates both vacuum and positive pressure ( 00kPa~0.8MPa) in one valve. CLICK Here to start download http://www.parkerkuroda.com/catalogue/va0.pdf