Installation and Operation Manual

Similar documents
Water Valve Shutoff. WVS Water Valve Shutoff

Owner s Manual and Installation Guide

Owner s Manual and Installation Guide

Owner s Manual / Installation Guide

ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL

INSTALLATION MANUAL. Model: PLUS For Technical Assistance, please call (800) , or visit

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL30

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

Water in Fuel Sensor Kit

INSTALLATION INSTRUCTIONS

Signal Mirror Installation Instructions Standard West Coast Mirror

INSTALLATION GUIDE OWNER S GUIDE

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM

VS 315 DELUXE 4-CHANNEL MOTORCYCLE ALARM. Installation And Operation Manual MEGATRONIX CALIFORNIA, U.S.A. VS 315 1

INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

Gen INSTALLATION MANUAL

How to Install and Remove a standard Teletrac Transceiver.

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

Battery Backup Sump Pump System Instruction Manual

Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

WirelessONE. Kit INSTALLATION GUIDE. Key Fob Activated Compressor System

Additional and Optional Components that may become Available: Flow Meter and Flow Meter Interface Module

Installation Instructions

ARC4000e 4 wheel compressor system w / 4 way Ride Pro controller

TIP SHEET. Installation Tips for SP-404/SP EVO-ALL + SPDT Remote Start/Alarm T1642

Installation and Commissioning of Auxiliary Power Unit

Installation / Operation Manual

INSTALLATION MANUAL. Model: PLUS Vehicle Security

Installation Tips for RS4/RS7 + EVO-ALL (NIS 3.c) + 2 diodes

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

SOIL-CLIK. Soil Moisture System. Owner s Manual and Installation Instructions

Instruction Manual for the. E-SL 450 Series

MAC FAUCETS. FA400 Autoluxe Faucets

Installation Tips for RS4/RS7 + EVO-ALL (NIS 3.b)

Installation Instructions for the Plug & Play Remote Start Package (EVOCHR5)

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

TRAC-Station BT Installation Instructions

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

TIP SHEET T2352, T3396. Installation Tips for RS1 + EVO-ALL 1-BUTTON REMOTE STARTER FOR: Acura RDX PUSH-TO-START / AUTOMATIC

Installation Instructions for the Plug & Play Remote Start Package (EVOCHR4)

Zonestar Installation Manual

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation Tips for your Remote Start/Keyless Entry (for Ford Vehicles) v3.3 Updated 1/13/2013

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

Installation Tips for RS1 + EVO-RIDE + SPDT. *(reglar key, automatic transmission vehicles ONLY)*

How Ta Find And Check

Here I Will Explain How To Install Recon Cab Lights In A 3rd Gen Dodge Ram.

Installation Tips for your RS-1 + Honda-SL3 (1.b) Remote starter Honda: ( FIT), ( Pilot), ( Ridgeline) Acura: ( MDX)

Installation Tips - (Crimestopper RS1/RS2) & (Fortin EVO-ALL 5): *regular key & automatic transmission only*

350 S. St. Charles St. Jasper, In Ph Fax

MAC FAUCETS FA400 WALL MOUNT FAUCETS

GM TRUCK BACKUP CAMERA INSTALLATION

Speed For Sale LLC Website: Telephone: Location: 3100 Engineering

Electric Actuator Accessories. Timer Board 115 VAC Input Suffix A (For EVR, EVS & EVT actuators)

Track Rocker Installation Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

TIP SHEET Installation instructions for EVO-NIST1 + LC1

Race Sport Lighting RSUKIT LED UNDERBODY KIT INSTALLATION GUIDE

H2oEliteLabs Max i Residential model - indoor installation Operation Manual

Instruction Manual. Computer Controlled A/C - D/C Sump Pump System

L5000 Plus. Installation & Setup Guide

TachMatch Instructions

Onboard. Onboard RTU270 Installation Manual

INSTALLATION GUIDE OWNER S GUIDE

COMMANDO REMOTE CONTROL ENGINE STARTER. Limited Warranty Statement MADE IN THE U.S.A. IMPORTANT KEEP YOUR INVOICE WITH THIS WARRANTY STATEMENT!

Track Rocker Installation Instructions

Step 1 : Starting the installation

Step 1 Wiring your remote start. Installation Tips for your Remote Start system (for GM vehicles) V3.3 revised 9/12/2013

SKID MARK GARAGE. Axillary Fuel Supply

COLD WEATHER START KIT Ceiling Mount 8000

Installation & Operations Manual

BUILDING PERMIT FEES

INSTALLATION GUIDE OWNER S GUIDE

Installation Tips for your Remote Start/Keyless Entry (for Honda/Acura Vehicles) [EVO-ALL] v1.02 updated 9/13/2013

Read the entire installation manual. There are several safety tips there that you need to know before you start

750 Paso Wiring Upgrade

Installation Instructions for the Plug & Play Chrysler/Dodge/Jeep Remote Start Package w/mux T5

Installation Tips For Crimestopper RS7 + Passlock-sl2(4) + DLRM + SPDT

Battery Backup Sump Pump System

Smart Wi-Fi Sprinkler Timer and Flow Meters

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

WirelessONE. Kit Key Fob-Activated Compressor System INSTALLATION GUIDE

Water Leak Detection in an Irrigation System

FLOLOGIC SYSTEM 3.0 INSTALLATION AND SETUP INSTRUCTIONS (LEAVE WITH CUSTOMER)

RS4 / RS7 + (4) + SPDT

CSI-300 Installation Instructions

CLASSIC II Portable Braking System

An ISO 9001:2008 Registered Company

ATTENTION. Custom Dynamics UTV Turn Signal Kit Installation Instructions

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

TIP SHEET T0937. Installation Tips For RS00/PS00 + ADS-TBSL-PL + SPDT

Part # Series RidePro 4 Way Compressor System 3 Gallon Tank Analog Gauges

Installation Tips for your Add-on Remote Start (for GM vehicles with INTSL Install 2) v3.2 Updated 11/12/2012

Designed for 2014 and newer 1500 Series and 2015 and newer Heavy Duty GM Silverado/Sierra Double Cab vehicles

Installation Instructions - ECS Tuning Vent Pod Vacuum/Boost Gauge Kit

Model-GS109 Brake Light Controller Module Installation & Users Guide

In This DIY We Will Show You How To Install Recon Backup Lamps (part # To Run On A Separate Switch & In Reverse.

Transcription:

Installation and Operation Manual Copyright 2017 Water Damage Prevention Systems LLC

Designed by Water Damage Prevention Systems LLC, the H2O SOS TM (Shut Off System) protects all types of buildings from water damage caused by faulty plumbing leaks or accidental overflows. Hardwired or wireless sensors are placed in areas where a leak or overflow may occur. When water contacts a sensor, an electronic signal is sent to the H2O SOS TM Control Panel. The Control Panel immediately sends an electronic signal to the H2O SOS TM Water Shut Off Valve. Within seconds of receiving the signal from the Control Panel the Valve closes and the water supply to the building is turned off. An audible alarm is emitted from the Control Panel announcing the Valve is closed. Suitable Locations for your H2O SOS TM Components DO NOT Install the H2O SOS TM Control Panel in an area that is easily accessible Install the H2O SOS TM Shut Off valve in on the main water line where it enters the building before it branches off. If all the interior water goes through the Water Softener the valve may be installed directly in front of the water softener. Locate sensors throughout the building where the possibility for water leaks or overflows may occur. Areas include all sinks, toilets, washing machine, water heaters, icemakers and refrigerators with water, dishwasher and Reverse Osmosis Systems. Install the Wireless Receiver (optional) in an area that is easily accessible. Install the Wireless Receiver (optional) as high as possible for the optimal radio range. Install the Wireless Transmitters (optional) in areas that easily accessible. All equipment, excluding Wireless Transmitters, will require a power supply. Receptacles for these components should be easily accessible. If possible, use a dedicated circuit for all equipment requiring a plug. Connect any equipment to electrical outlets that are controlled by timers or wall switches. Connect any equipment to electrical outlets to circuits that control large appliances or equipment. Install any equipment in areas of direct sunlight or in areas that are exposed to moisture or dust. Install wireless equipment (optional) where interference may reduce the radio range between the Wireless Transmitters Receiver.

Items Needed Prior to Beginning Installation 18/3 and 22/2 gauge wire, stranded and unshielded. Properly sized crimp type splices, wire nuts. # 8 screws for mounting Water Sensors. Properly sized mounting boxes. Assortment of screw drivers. Wire strippers and crimpers. Drill and bits. Wire staples and zip tie Prewire of Hardwire Sensors Determine location of Control Panel, Water Sensors and Shut Off Valves. Use a 2 gang electrical box to house Control Panel. Install a single gang electrical box close to valve location. Run 22/2 gauge wire, stranded and unshielded, from sensor locations to Control Panel location. Run 18/3 gauge wire, stranded and unshielded, from valve location (single gang box) to Control Panel location. Use marking numbers to separate sensor wires. When running wires, try to run as high as possible away from all other wiring in the structure. Staple and secure wires to framing. Terminate sensor wires for sinks by wrapping around plumbing drain and secure wire electrical tape. Terminate sensor wires for toilets on bottom plate of framing. Determine finish height of floor before securing. Drill a ¼ hole at an angle through bottom plate. Drive a nail into plate, wrap wire around tape and secure with tape. Determine areas to plug equipment in to wall plugs.

H2O SOS TM Valve Installation Make certain that the water supply is turned off at the meter and that no power supplies for the system are plugged in. The H2O SOS TM Valve must be installed on the main water line and downstream from any of the following: the primary shut valve (water meter, the pressure regulator, irrigation line or fire suppression system line. Ideal locations for the Shut Off Valve include: in the garage, basement or crawl space, on the water softener loop (before the water softener). If the building is on a slab (no basement) the valve can be installed outside. However, the valve should be located no less than 12 above grade and it must be protected from direct sunlight, moisture and freezing conditions with an appropriate water proof enclosure. Install the valve in a location is always accessible. The H2O SOS TM Shut Off Valve may be installed horizontally or vertically (90-degree angle). To install the valve a length of pipe must be removed to accommodate the valve/flow body assembly and any connectors. All common methods of pipe connections including unions and treaded pipe can be used When necessary consult with a Licensed Plumber to verify local plumbing codes. H2O SOS TM Control Panel Installation The Control Panel is designed to be mounted on a two-gang electrical box, either a new construction box or a retro-fit box. Use the supplied screws to mount the Control Panel (after making connections) Connect as shown using the directions on the next page.

H2O SOS TM Single Zone Control Panel Wiring Valve Operation Control Panel Wiring Harness Connect Blue wire from Valve to 1 Green and to 24 VAC Power Supply Connect Brown wire from Valve to other Green and Red from Control Panel and 24 VAC Connect Black wire from Valve to Brown from Control Panel Connect the 2 White Wires (Water Probes) from Control Panel to the incoming wires from the Water Sensors and /or the Wireless Receiver (OPTIONAL). Connect all the Reds to one side (WHITE) and all the Blacks to the other side (WHITE). Before making the connection shown above unplug the 24VAC Power Supply from the Control Panel. 1. Once the connections to the valve have been made Short (wet) across the H2O SOS TM Water Sensor. The Green LED will turn off, the Red LED will begin flashing and the Audible Sounder will turn on and the Valve will close. 2. Press the Black Push Button once to silence the alarm. If the sensor is wet the Red LED will turn Steady ON and the Valve will be closed. 3. Once the sensor has dried the Green LED will come back on. Press the Black Button to open the valve to restore the water service. 4. To OVERRIDE the valve (Red LED on only) Press and hold the Black Push Button in until the Amber LED comes on and the Red LED goes off. DO NOT LEAVE IT ON OVERRIDE IF SOMETHING IS LEAKING!!!! Maintenance of valve These electric actuators do not need any formal maintenance. The internal lubrication is sufficient for the life of the actuator. In case of damage or a problem in operation please contact: Water Damage Prevention Systems LLC PO Box 86 Converse, TX 78109-0086 210-566-4446

H2O SOS TM Schematic Hardwired System Wireless sensors and hardwired receiver