WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE

Similar documents
PIM Pressure Independent Module

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

OWNER S MANUAL Please read and understand all precautions prior to use.

Installer Guide smart connect

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Please read and understand all precautions prior to use.

V-D2425 and V-D2440 Digital Clock

Touchstone TB130 DC Output UPS

OPERATING INSTRUCTIONS

Owners Manual for TPMS plus GPS

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

AS-RFK2315. User Guide. Two-Way FM LED Remote System. Available functionalities depend on vehicle. Consult your dealer for more information.

Model WS-6020U Solar Station QUICK SETUP GUIDE

AeraMax Pro AM IV. Please read these instructions before use. Do not discard: keep for future reference.

User s Manual TX MHz Powercaster TM Transmitter

Operating Instructions

Solar Powered Wireless Temperature Station & Sensor

PerfectTilt RF Motorized Shutter User Manual

Monnit Wireless Range Extender Product Use Guide

CLASSIC II Portable Braking System

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

USE AND CARE GUIDE 15 INCH WHITE ROUND FLAT PANEL FIXTURE WITH SELECTABLE COLOR TEMPERATURE

PIM Pressure Independence Module

翔鑫科技股份有限公司. Oro Technology Co., LTD. 無線胎壓監測器 Tire Pressure Monitoring System 型號 : W410

Instruction Manual. SmarTire LF Initiator Tool. PN: Revision 1.2. Copyright 2006 SmarTire Systems Inc.

Auto-Lift Operating System

Instruction Manual 03

WIRELESS SMART CHARGING PAD OPERATING INSTRUCTIONS PLEASE READ BEFORE OPERATING THIS EQUIPMENT

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

Installation Instructions RF4510-EA

User Manual TX MHz PowerSpot Transmitter

Cab Control Operators Manual

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LED Recessed Troffer Retrofit Kit

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to

2800 OPERATING INSTRUCTIONS

Select II Portable Braking System

Cable/Gate Lock INSTALLATION MANUAL

Hendrickson Fit Adapter Installation Instructions

Full Function Display User s Manual

BatteryChargers. Quick Start Guide AA RECHARGER POWERCHARGER

WVC. Wireless Valve Controller. Multiple Station Battery Powered Irrigation Controller. Owner s Manual and Installation Instructions

4 WAY WIRELESS REMOTE CONTROL SYSTEM. User Manual

Wireless Key Tracker. Locate Lost Keys instantly

OPERATING INSTRUCTIONS

Owner's Manual. For latest instructions please go to

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

To ensure correct operation and service please read these instructions before installing and operating the TPMS P451 TPMS Manual TABLE OF CONTENTS

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

1000-Watt Energy Center

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

RJH-4/6046. Wireless 3.5 Channel Mega Helicopter. (Instruction Manual)

INSTALLATION INSTRUCTIONS

Radio-Control Raceway

SOKAR FPV DRONE. Quick Start Manual SkyRC Technology Co., Ltd. All Rights Reserved. Version

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

SolarWrap. Quick Start Guide. Model # PP1040/PP1025

VERSA TOUCH 2 INSTALLATION VERSA TOUCH 2 CONTROL BRACKET INSTALLATION

IMPORTANT SAFETY INFORMATION:

LIPSTICK CHARGER POWERFUL UNIVERSAL PORTABLE CHARGER OPERATING INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

USE AND CARE GUIDE 4 FT. LED WRAP LIGHT

Back-Up Sensor System

6. Electrical. 7. Settings. 8. Quick

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Innovative Circuit Technology Ltd.

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1107

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

BroadBand PowerShield. 20 AHr Battery. User Manual

HERCULES ITEM NO UNBREAKABLE HELICOPTER AGES CHANNEL GYRO RC HELICOPTER FEATURES

USER GUIDE. c--' c-' Remote. for #SED-10R

Welcome to ThermaCELL Technology

IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE

SPC Series. Digital Scale. Operation Manual

5-Piece Grill Tool Set WITH DIGITAL THERMOMETER

Thermometer models / 00831A

LIGHT & SOUND BATH VANITY LIGHT

TPMS (Tire Pressure Monitoring Systems)

Wireless Thermometer model 00380

Conserve Insight Energy Use Monitor. User Guide

Installation Guide(s)

SAVE THESE INSTRUCTIONS

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Innovative Circuit Technology Ltd.

Memory Foam Massaging Bath Pillow with Wireless Remote Control

RF KIT TYPE: 1-Button Remote Controls 9816V, 9816P, 9816X. User s Guide

Use and Care Guide.

Mazda New CX-5 TPMS Pressure by Location Display TABLE OF CONTENTS TIRE PRESSURE MONITORING SYSTEMS, TPMS... 2

RIDESENSE User Manual

MOTION-ACTIVATED WALL LANTERN

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

Thermometer model 00826

To ensure correct operation and service please read these instructions before installing and operating the TPMS. TPMS Manual

Use and Care Guide. Item #

User Guide. Digital Shipping Scale S150

MR16out Processor Installation and Specifications

Transcription:

FORM 040.202 REV 106 WIRELESS WALL ADJUSTER INSTALLATION, OPERATION AND MAINTENANCE Models: ADJ-W Wireless Wall Adjuster Compatible with all Type HC, CW and C Therma-Fuser Diffusers CONTENTS ORDERING... 1 DAMAGED FREIGHT CLAIM PROCEDURES... 1 STORAGE... 1 INSTALLATION... 1 DISPLAY INDICATORS... 2 CONFIGURATION... 2 OPTIONS... RESETTING PROGRAM... 4 ERASING PROGRAM... 4 TROUBLESHOOTING... 4 TWO YEAR WARRANTY... 5 ORDERING Order an Adjuster and a Remote Adjust Option for each Therma-Fuser Diffuser to be connected to the Adjuster. 1. Order one (1) Wireless Wall Adjuster for each space requiring easy temperature control adjustment. ADJ-W 2. Order one (1) Master Diffuser and up to four (4) Secondary diffusers per adjuster.. Order a wireless remote adjust option for each Master Diffuser -WA2M for Model TF-HC and TK-HC diffusers -WA1M for All other model diffusers 4. Order a remote adjust option for each Secondary Diffuser -DA2 for Model TF-HC and TK-HC diffusers -DA1 for All other model diffusers DAMAGED FREIGHT CLAIM PROCEDURES When the Wireless Wall Adjuster units are received, inspect for damage which may have occurred during shipment. If damage is evident, it should be noted on the carrier s freight bill. A written request for inspection by the carrier s agent should be made at once. STORAGE Do not store for prolonged times at temperatures exceeding 10 F/ 56 C. Acceptable humidity level is 5-95% relative humidity non-condensing. INSTALLATION Wireless Wall Adjuster Location 1. Locate the diffuser in as bright a light as possible, but not in direct sunlight as the photovoltaic cell is optimized for fluorescent lighting. The Adjuster will operate in light levels as low as 100 lux or 10 footcandles. 2. If the Room Temperature Sensor Option is installed (see Options) then locate the Adjuster on an interior wall within the space to be monitored. Wireless Wall Adjuster Installation The Adjuster is suitable for mounting directly onto the wall or onto a standard 2x4 electrical box. 1. Open the adjuster. Slide the adjuster up from the back plate approximately 1/4 /6mm to free the adjuster from the back plate (see Fig. 2 Opening Adjuster). 1 /2in 89mm 1 /2in 1mm SETPOINT COOLER 2 9 / 16in 65mm 1 in 26mm WARMER 11 / 16in 17mm Fig. 1 Wireless Wall Adjuster Copyright Acutherm 2011 Page 1 of 8

WIRELESS WALL ADJUSTER INSTALLATION OPERATION AND MAINTENANCE 2. To mount directly to the wall (see Fig. Back Plate), use the back plate of the adjuster as a template to locate the holes. For drywall installation drill two / 16 /5mm holes, insert the plastic wall anchors (included) and attach the base plate of the adjuster using the screws provided.. To mount onto a standard 2x4 electrical box use the holes top and bottom and connect directly to electrical box (see Fig. Back Plate). 4. Close the adjuster. Latch the top of the adjuster on the top of the back plate and then press the bottom to snap the two together (see Fig. 4 Closing Adjuster). SETPOINT COOLER WARMER Master Diffuser Installation 1. Install the Diffuser(s) as per the Installation Instructions for the model of Therma-Fuser Diffuser. Fig. 2 Opening Adjuster 2. Connect 24VAC to the two screw terminals labeled 24VAC (POWER IN) (see Fig. 10 Wiring Diagram). Note: Green light indicates power is on. TOP DISPLAY INDICATORS In addition to displaying the set point there are three Indicators; INSTALL, PENDING and FAULT (see Fig. 7 Adjuster Display Indicators). 1. INSTALL displayed when the Adjuster has not been installed or Joined to a Diffuser. 2. PENDING displayed when the Adjuster is waiting to communicate with the Diffuser.. FAULT displayed during a Fault condition (see Troubleshooting). CONFIGURATION 1. Configure Display Settings. There are two (2) dip switches (see Fig. 5 Configure Adjuster Settings) on the board of the adjuster that should be checked and adjusted if required (see Opening the adjuster Installation step 2). Switch 1 sets the units of measurement for the set point display from F to C. Switch 2 enables the numerical display of the set point. 2. Configure Master Diffuser Settings. There are two (2) dip switches (see Fig. 6 Configure Diffuser Settings) on the board of the Master Diffuser that should be checked and adjusted if required. Switch 1 is not used and must remain in the Off position. Switch 2 should only be switched On if the Master Diffuser is a model ST diffuser. Fig. Back Plate Fig. 4 Closing Adjuster Page 2 of 8

2 4 1 0 5 9 8 ACUTHERM, LLC ADJUSTER-W (DIFFUSER UNIT) ASSY: 608-2060-REV O N 1 2 FORM 040.202 REV 106 (Supersedes FORM 040.202 REV 104) JOINING ADJUSTER AND DIFFUSER 1. The Adjuster and the Master Diffuser must be joined to enable wireless communication between them. 2. Press and hold the Install button located in one corner on the room side of the Diffuser (see Fig. 7 Diffuser Button and Light) for four seconds until the light starts to flash slowly.. While the light is flashing (approx. 0 seconds) press and hold both buttons on the Adjuster for four seconds until INSTALL flashes slowly on the screen (see Fig. 8 Adjuster Display Indicators) and then release. 4. The light on the Diffuser and the INSTALL on the Adjuster display will both stop. The Master Diffuser and Adjuster are now joined. If the light on the Diffuser or the INSTALL on the Adjuster stay on then they did not join successfully. See Erasing Program prior to trying again. OPTIONS 1. OPTIONAL SECONDARY DIFFUSERS. Connect any Secondary Diffusers with a simple pair of wires to the two screw terminals labeled SECONDARY DIFFUSERS (see Fig 10 Wiring Diagram). 2. OPTIONAL BUILDING AUTOMATION SYSTEM INTERFACE. Connect the BAS controller to the three screw terminals labeled 0-10V OUT, COM, and 0-10V IN (see Fig. 10 Wiring Diagram). Note: The 0-10VDC BAS output is always active (see Table 1) on the 0-10V OUT terminal. An input of other than 0VDC on the 0-10V INPUT terminal will activate the BAS input. Adjustment with the buttons on the Adjuster is still possible. The last adjustment of the set point, whether by BAS or occupant, will set the control temperature. Volts DC Set Point Temperature ±0.10 1 68 F / 20 C 2 69 F / 20 C 70 F / 21 C 4 71 F / 21 C 5 72 F / 22 C 6 7 F / 22 C 7 74 F / 2 C 8 75 F / 2 C 9 76 F / 24 C be used to display the room temperature and control the Duct Heater Option. ON ON OFF Switch Purpose Off On 1 Units for Display F C 2 Numeric Display Off On 24VAC (POWER IN) SECONDARY DIFFUSERS 0-10V COM 0-10V OUT (BMS) IN TX COM RX OUT (RS-22) IN HOT RTN SW (AUX HTR CTRL) 500mA FUSE 6 7 Fig. 5 Configure Adjuster Settings INTERNAL HEATER ROOM COM TEMP DUCT DUCT SWITCHES 1. N THERM Y 2. NORM - ST ON OFF ON 1 2 Switch Purpose Off On 1 For future use Off - 2 ST Diffuser Off On Fig. 6 Configure Diffuser Settings Fig. 7 Diffuser Button and Light SETPOINT COOLER INSTALL PENDING FAULT WARMER 1 2 Table 1 Set Point Temperature. OPTIONAL ROOM SENSOR. A room temperature sensor may be ordered as an option for the Adjuster. The sensor is located in the Adjuster and may then Fig. 8 Adjuster Display Indicators Page of 8

WIRELESS WALL ADJUSTER INSTALLATION OPERATION AND MAINTENANCE When turned ON the display on the Adjuster will show the room temperature until either button is pressed. Upon a button press, the display will show the set point and the warmer/cooler bars for approximately 0 sec before reverting back to room temperature. To turn on/off the room sensor, reset the Adjuster by pressing and holding both buttons until INSTALL flashes rapidly (approximately 10 sec) and then releasing both buttons. The firmware version will be briefly displayed followed by either the word ON or OFF. While ON or OFF is displayed use the warmer cooler buttons to switch the room sensor either ON or OFF. CAUTION: If the sensor is not installed then the Adjuster must be set to OFF. 4. OPTIONAL DUCT HEATER. An auxiliary heat board may be ordered as an option on the Master Diffuser board and used to switch on/off an Acutherm Acu- Zone duct heater. Note: This option requires that the Room Temperature Sensor Option also be installed. Connect three wires from Acu-Zone terminals 1, 2, and (see the Acu-Zone heater wiring instructions) to the terminals (AUX HTR CTRL) on the auxiliary heat board; 1 to HOT, 2 to RTN, and to SW (see Fig. 10 Wiring Diagram). Configure the heating set point to switch on the Acu- Zone heater by turning the ten position potentiometer on the auxiliary heat board (see Fig. 9 Auxiliary Heater and Table 2). CAUTION: If no heater is connected, the potentiometer MUST be set to 0 the OFF position. Set Point Position Temperature 0 OFF 1 65 F / 18 C 2 66 F / 19 C 67 F / 19 C 4 68 F / 20 C 5 69 F / 21 C 6 70 F / 21 C 7 71 F / 22 C 8 72 F / 22 C 9 7 F / 2 C Table 2 Auxiliary Heater Set Point When the room temperature, measured by the room temperature sensor, drops below the heating set point, the heater will be turned on. When the room warms 2F /1 C above the heating set point then the heater will be turned off. HOT RTN SW (AUX HTR CTRL) 2 4 1 5 0 6 7 9 8 Fig. 9 Auxiliary Heater RESETTING PROGRAM Use the Reset function to reset the firmware in the Adjuster and or the Diffuser. Resetting restarts the firmware, but does not erase the set point or joining. Adjuster: Pressing and holding both buttons on the Adjuster until INSTALL flashes rapidly (approximately 10 sec) and then releasing will reset the Adjuster. Upon releasing the buttons a software version code is briefly displayed followed by the status (either Off or On) of the temperature sensor. Diffuser: Pressing and holding the button on the Diffuser until the LED flashes rapidly (approximately 10 sec) and then releasing will reset the diffuser board. ERASING PROGRAM Use the Erase function to remove the Joining between the Adjuster and or the Diffuser. Adjuster: Pressing and holding both buttons on the Adjuster until the INSTALL is lit continuously (approximately 15 sec) and then releasing will erase the Adjuster. The Adjuster can then be joined to a different diffuser. Diffuser: Pressing and holding the Install button (see Fig. 7 Diffuser Button and Light) on the Diffuser until the light is lit continuously (approximately 15 sec) and then releasing will erase the Diffuser board. The Diffuser can then be joined to a different Adjuster. TROUBLESHOOTING 1. Inspect the wiring at the diffuser board and check for bad connections at terminals. 2. Check the incoming power at the diffuser board. Power across terminals 24VAC POWER (see Fig. 10 Wiring Diagram) should be 24VAC ±2VAC. If the power is out of tolerance: a. Check for proper sizing of transformer and correct primary voltage. b. Check for excessive voltage drop between transformer and master diffuser. ACUTHERM HEADQUARTERS 1766 Sabre Street Hayward, CA 94545 USA Tel +1 510 785 0510 Fax +1 510 785 2517 www.acutherm.com

FORM 040.202 REV 106 (Supersedes FORM 040.202 REV 104). If the green Power LED is not lit, then check the 500mA Fuse (see Fig. 10 Wiring Diagram). 4. Check the set points on the diffuser thermostat/ actuators. Both cooling and heating should be set to 76 F/24 C. 5. Inspect contact between resistance heaters and thermostat(s) located in the Therma-Fuser diffuser. If contact is loose tighten the shrink tubing by heating it. 6. Check the Display Indicators on the Adjuster. a. If the INSTALL indicator is lit then the Adjuster needs to be installed or joined to a Diffuser (see Joining Adjuster and Diffuser). b. If the PENDING indicator is lit then the Adjuster is waiting to communicate with the Diffuser. If the PENDING indicator stays lit for an extended period of time then there is a communication problem and there may be interference with the radio signal. c. If the FAULT indicator is flashing then: Flash Code 1 short 2 short short 4 short Condition Low Voltage the voltage on the storage capacitor is low and may not be sufficient to allow wireless communication allow the Adjuster some time in the light to charge Time Out time out occurred while accessing radio and may be due to no response from Diffuser or poor signal levels Room Sensor Fault there is either a short or open detected from the room temperature thermistor Set Point Error failure to store set point in non-volatile memory 7. Check the fault indicator on the Diffuser. a. If the light on the Install button (see Fig. 7 Diffuser Button and Light) is flashing then: Flash Code 1 short 2 short Condition Low/High AC Line Voltage the supply voltage is either less than 21VAC or greater than 27VAC Room Sensor Fault there is either a short or open detected short from the room temperature thermistor BAS Input Fault the BAS input voltage is greater than 9.5VDC 8. Adjust the set point up to the warmest setting (76 F/24 C) and measure the DC voltage across terminals INTERNAL HEATER. Voltage should be less than 1VDC. 9. For secondary diffusers also measure the DC voltage across terminals and 4. Voltage should be less than 1VDC. 10. Adjust the set point down to the coolest setting (68 F/20 C) and measure the DC voltage across terminals INTERNAL HEATER. Voltage should be 12-16 VDC (17-24 VDC for Model ST diffusers). 11. For secondary diffusers also measure the DC voltage across terminals and 4. Voltage should be 12-16 VDC (17-24 VDC for Model ST diffusers). 12. Remove wires from terminals INTERNAL HEATER (see Fig. 10 Wiring Diagram) on the diffuser board. Measure resistance across the wires connected to the heaters. Resistance should be: a. 500 Ω ± 50 Ω for Model TF-HC and TK-HC diffusers. b. 1000 Ω ± 100 Ω for all other diffusers. TWO YEAR WARRANTY Acutherm warrants that its Wireless Wall Adjuster, exclusive of any options and accessories (whether factory or field installed) shall be free from defective material or workmanship for a period of two (2) years from the date of shipment and agrees to repair or replace, at its option, any parts that fail during said two (2) year period due to any such defects which would not have occurred had reasonable care and proper usage and all parts and controls remain unaltered. Acutherm makes NO WARRANTY OF MERCHANTABILITY OF PRODUCTS OR OF THEIR FITNESS FOR ANY PURPOSE OR ANY OTHER EXPRESS OR IMPLIED WARRANTY WHICH EXTENDS BEYOND THE LIMITED WARRANTY ABOVE. ACUTHERM S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM DEFECTS SHALL IN NO EVENT EXCEED THE COST OF REPAIR OR REPLACEMENT OF PARTS FOUND DEFECTIVE UPON EXAMINATION BY ACUTHERM. IN NO EVENT SHALL ACUTHERM BE LIABLE FOR INCIDENTAL, INDIRECT OR CONSEQUENTIONAL DAMAGES OR DAMAGES FOR INJURY TO PERSONS OR PROPERTY. Acutherm shall not be responsible for freight to or from its plant in connection with the inspection, repair or replacement of parts under the terms of this limited warranty nor for cost of removal or installation. Page 5 of 8

WIRELESS WALL ADJUSTER FORM 040.202 REV 106 INSTALLATION OPERATION AND MAINTENANCE (Supersedes FORM 040.202 REV 104) Master Diffuser Factory Wiring Factory wiring to resistance heater(s) in Master Diffuser. WIRELESS ANTENNA DO NOT SHIELD OR COVER THIS AREA (not used) SWITCHES 1. N THERM Y 2. NORM - ST ROOM COM TEMP DUCT DUCT INTERNAL HEATER 500mA FUSE ACUTHERM, LLC ADJUSTER-W (DIFFUSER UNIT) ASSY: 608-2060-REV ON 1 2 56789 124 0 Field Wiring 24VAC (POWER IN) SECONDARY DIFFUSERS 0-10V COM 0-10V OUT (BMS) IN TX COM RX OUT (RS-22) IN HOT RTN SW (AUX HTR CTRL) Terminals 24VAC (POWER IN) 24 VAC ± 2 VAC 24VAC Wiring and transformer by others Power requirements vary with the number of diffusers: 1.0 VA per TF-HC, TK-HC and 4-slot linear diffusers 0.65 VA per ST diffuser 0.5 VA per TF, TK, TB & TL diffuser types -C & -CW Note: Typically transformers supplied with other equipment are sized for only that equipment. A separate transformer dedicated to the diffusers is recommended. (Power LED) (Factory Programming) Terminals SECONDARY DIFFUSERS Optional Secondary Diffuser(s) Wiring by others. Up to 4 Secondary diffusers may be wired (daisy chain or home run) to each Master diffuser. Wiring 20 AWG min. 5ft / 10.5m max each diffuser. 4 Terminals 0-10V OUT COM (BMS) 0-10V IN Optional Building Automation System Interface Wiring by others. 0-10 VDC input signal for set point adjustment. 0-10 VDC output signal for reading the set point. OUT COM IN Terminals HOT RTN SW (AUX HTR CTRL) Optional Acu-Zone Duct Heater Control Wiring by others. Requires Room Temperature Sensor Option to be installed and then will switch on and off Acu- Zone Duct Heater. 1 2 Fig. 10 Wiring Diagram Page 6 of 8

WIRELESS WALL ADJUSTER FORM 040.202 REV 106 INSTALLATION OPERATION AND MAINTENANCE (Supersedes FORM 040.202 REV 104) REGULATORY STATEMENTS, PRECAUTIONS AND WARNINGS U.S. and Canada This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This module generates RF energy. DO NOT use this module in any application where in normal operation, the antenna will be located within 20cm of the head or body of the operator. This device must not be co-located or operated in conjunction with any other antenna or transmitter. Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the distance between the equipment and the receiver. Connect the equipment to outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/tv technician for help. Australia and New Zealand N010 I ndia ETA Certificate No. 12/2011/WRLO Japan 007-AA0075 007-AA0075 (Contains Japan Radio Law Approval Certification number 007-AA0075) Korea 이기기는가정용 (B 급 ) 전자파적합기기로서주로가정에서사용하는것을목적으로하며, 모든지역에서사용할수있습니다. (This unit residential (B grade) primarily as EMC devices intended to be used at home and in all regions Can be used.) Applicant Crosby Engineering Services Equipment 2.4 GHz Zigbee RF Module Model RFM250 Manufactured by Crosby Engineering Services Country of Origin USA Page 7 of 8

ACUTHERM HEADQUARTERS 1766 Sabre Street Hayward, CA 94545 USA Tel +1 510 785 0510 Fax +1 510 785 2517 www.acutherm.com