Emergency Shock Absorbers WN-M 1,5. Deceleration Technology. ONLINE Calculation + 2D / 3D CAD Download. F m

Similar documents
Deceleration Technology. Special Shock Absorbers. P.E.T. Machines W-PET 1,0-120 W-PET 1,

Deceleration Technology. Shock Absorbers WM-E 1,5. Old Series: Do not use for new designs. ONLINE Calculation + 2D / 3D CAD Download

Heavy-Duty Shock Absorbers HLS-110. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download. F m

Elasto-Fluid Springs WES-F. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download

Heavy-Duty Shock Absorbers LDS 25. Deceleration Technology. ONLINE Calculation and 2D / 3D CAD Download. F m.

Deceleration Technology. Rotary Dampers with high-torque range WRD-H 2515 WRD-H 3015 WRD-H 4025 WRD-H

Safety Shock Absorbers SCS33 to SCS64

Miniature Shock Absorbers SC²25 to SC²650 Self-Compensating

Pallet Stoppers WPS 500. Deceleration Technology. ONLINE 2D / 3D CAD Download

Miniature Shock Absorbers SC190 to SC925 Soft-Contact and Self-Compensating

Miniature Shock Absorbers MC150 to MC600 Self-Compensating

Shock Absorbers for P.E.T. Machines W-PET

Ametric Automation & Deceleration Technology

Safety Shock Absorbers SDH38 to SDH63

V2 FASTENING CLAMP. For tools of: ASSEMBLY VERIFICATION HANDLING MECHANIZING WELDING, etc. System patented by MISATI

Linear guides MGE 13.2 Linear guides

Heavy-Duty Shock Absorbers

Extruded Body Cylinders, ISO 6431, ISO compliant Series 61

Single and double-acting, magnetic, cushioned Standard, low friction, low temperatures and tandem versions ø 32, 40, 50, 63, 80, 100, 125mm

Aluminium profile. TANDEM: Double thrust and traction forces. LOW FRICTION: Friction force reduced by over 40%

Tie-rod Cylinders, ISO 6431, ISO compliant Series 60

Single and double-acting, magnetic, cushioned Standard, low friction and low temperature versions ø 32, 40, 50, 63, 80, 100, 125mm

Series 63 ISO cylinders

Aluminium tube and profile

Safety Shock Absorbers SDP63 to SDP160 For Crane Installations

Cylinders Series 61 - Aluminium profile

GRIPPERS SERIES P3 - P12 ACTUATORS

Heavy-Duty Shock Absorbers LDS

Heavy Industrial Shock Absorbers CA 2 to CA 4

Standard Hydraulic Cylinder range

Pneumatic cylinders Compact cylinders Series P1J

Kuhnke Technical Data. Contact Details

RODLESS CYLINDER SERIES PU ACTUATORS

Cylinders with integrated guide Series QCTF and QCBF

TITGEMEYER Tb1421GB(1115)1. TIFAS LockBolt Pin and collar fastening system

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Aluminium profile. Double-acting, cushioned, magnetic ø mm

Large Bore Extruded Cylinders, ISO 6431 Series 41

DSV. Operating Manual. Double Seal Butterfly Valve. Read and understand this manual prior to operating or servicing this product.

ORIGA Pneumatic Linear Drives OSP-L

Pneumatic cylinders series CX Double acting with magnetic piston, ISO 15552, stainless steel G1/8 to G1/2 piston Ø 32 to 100 mm

Vent and bleed filter, water-absorbing. Type BFSK 25 to 125. Contents. Features. RE Edition: Replaces: 05.13

Aluminium profile. Double-acting, magnetic, cushioned ø 32, 40, 50, 63, 80, 100 mm

Double-acting, magnetic, cushioned ø16, 25, 32, 40, 50, 63, 80

RA/8000, RA/8000/M. Pneumatic cylinders ISO 6431, VDMA and NFE Non-magnetic and magnetic piston Double acting Ø 32 to 320 mm

Kuhnke Technical Data. Contact Details

PRA/181000, PRA/181000/M PRA/183000, PRA/183000/M

Breathing and air bleed filter, water-absorbing. Type BFSK. Contents. Features. RE Edition: Replaces: 51412

Hytork XL Series Technical data pneumatic Rack and Pinion actuators

Single- and double-acting, cushioned, magnetic ø 32, 40, 50, 63, 80, 100 and 125 mm

Rotary-linear actuator HSE4 Hydraulic / 100 bar. GATEWAY to new technologies.

Stainless Steel Cylinders, ISO 6432, Bore 10-25mm - P1S

Linear Actuator with Toothed Belt Series OSP-E..B

BALL VALVE SERIES Pneumatic actuator - El-O-Matic

ELECTRIC ACTUATOR - RODLESS ELEKTRO SK SERIES ACTUATORS

Single and double-acting, cushioned, magnetic. ø 32, 40, 50, 63 mm

PRA/182000, PRA/182000/M

ANTI-CORROSIVE CYLINDERS WITH TIE RODS Ø 32 to 125 mm - double acting - ISO with adjustable pneumatic cushioning

Double acting, cushioned, magnetic Ø mm

Series 6PF Positioning Feedback cylinders 1/ Double-acting low friction, magnetic ø 50, 63, 80, 100, 125 mm

Contamination switch VS

Linear drives DGC Key features

TOX -Powerpackage Accessories

> piston force up to 20,1 kn. > operating pressure 250/350 bar. > chemically nitrided body. > piston force up to 44,0 kn. > operating pressure 350 bar

E-Series Screw Jacks. Metric Machine Screw Jack. Stainless Steel Machine Screw Jack. Metric Ball Screw Jack

XG*-***-****-***-****

Linear drives DGC-K. Festo core product range Covers 80% of your automation tasks

Toggle clamps, manual and pneumatic

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Series CP95. Profile Design ISO/VDMA Air Cylinder. Increased kinetic energy absorption. Improved end of stroke cushion capacity

Bore ø 32, 40, 50, 63, 80, 100, 125 Ports 32 = 1/8, 40/50 = 1/4, 63/80 = 3/8, 100/125 = 1/2

Stainless steel Cylinders Series 90

Spring hangers, spring supports

PRA/181000, PRA/181000/M PRA/183000, PRA/183000/M

Feed separators HPVS

Our policy is one of continued research and development. We therefore reserve the right 10/99 N

Heavy-Duty Shock Absorbers

Linear Drive with Ball Screw Drive Series OSP-E..SB

Linear Drive with Toothed Belt Series OSP-E..B. Contents Description Overview Technical Data Dimensions Order Instructions 46

Series 45 anti-rotation guide units

Balancing Unit BBS Series

Operating instructions friction couplings ECS and ECSK

Industrial Gas Springs Pull Type

RA/28000, RA/ Pneumatic Cylinders ISO 6431, VDMA and NFE Non-magnetic and Magnetic, Single Acting 32 to 100 mm

A44000, LINTRA-LITE Rodless Cylinders Non-magnetic and Magnetic Piston, double acting

Linear drives DGC. Festo core product range Covers 80% of your automation tasks

Guide units EAGF, for electric cylinders

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

-V- New. Linear drives DGC Features. 2 Internet:

Hydraulic cylinders are devices which convert fluids power into mechanical force or motion. This force or motion will be in a straight line.

O SL. BPW Original spare parts Air suspensions series O / SL / AL BPW BERGISCHE ACHSEN BPW ORIGINAL SPARE PARTS. BPW Original spare parts

01 09 Installation guidelines Air suspension units GL70 GL70HD GL70L GN Air suspension units GL70 GL70HD GL70L

OPERATING INSTRUCTIONS FOR MINICLAMPS FOR ROBOT GRIPS

12/95 N Our policy is one of continued research and development. We therefore reserve the right

Operating Instructions

Installation and Operational Instructions for EAS - HTL housed overload clutch Sizes 01 3 Type 490._24.0

Shock Absorber & Gas Spring

M/46800/M, M/46800/HM, M/46800/PM

Series C95 ø32, ø40, ø50, ø63, ø80, ø100

Cam roller guide LF6S complete axis

Transcription:

Emergency Shock Absorbers WN-M 1,5 Deceleration Technology ONLINE Calculation + 2D / 3D CAD Download F m V S

Benefits The shock absorber will be adapted individually to the customer s requirement. Enlarged piston: - Max. +400% energy - Max. -50% costs / Nm Piston: - Hardened, aluminiumtitanium-nitride coated - Special seals + oils Pro Tec: - Massiver Körper ohne Sicherungsring Integrated stop: - Max. security Extended life cycle: - Nitrated guidance system Temperature: - Standard: -20 C -...+80 - Low-temperature: -50 C-...+60 C - High-temperature: 0 C-...+120 C Special models:: - Stainless steel: V4A/DIN1.4404/AISL 316L - V4A(/DIN1.4404/AISL 316L) - For pressure chambers up to 7 bar - USDA-H 1 compliant for food industry

A F1 B HB A* ØE1 Threads ØE F2 SW *A: PU / AS: Steel Add A / AS after the part no. AS* ØE1 DIMENSIONS A B Ø E Ø E1 F1 F2 SW WN-M 1,5 x 1 M 45 x 2 148 89 39,6 31 18 13 41 WN-M 1,5 x 2 M 45 x 2 198 114 39,6 31 18 13 41 WN-M 1,5 x 3 M 45 x 2 248 139 39,6 31 18 13 41 SPECIAL THREAD - from stock Series Code Threads Example 1,5 K M 42x1,5 WN-M 1,5x1-1 K 1,5 H M 42x2 WN-M 1,5x1-1 H 1,5 L M 45x1,5 WN-M 1,5x1-1 L 1,5 U 1 3/4-12 UNF WN-M 1,5x1-1 U PERFOMANCE Energy absorption Return spring force Torque Weight Nm/HB (max.) min. N max. N Nm max. kg WN-M 1,5 x 1 25 1400 50 70 40 0,95 WN-M 1,5 x 2 50 2500 35 70 40 1,1 WN-M 1,5 x 3 75 3500 35 80 40 1,2 Technical data at + 20 C Technichal Data Weight 1,5x1: 0,95 kg 1,5x2: 1,10 kg 1,5x3: 1,20 kg Return spring force 1,5x1: 50 N/min - 70 N/max 1,5x2: 35 N/min - 70 N/max 1,5x3: 35 N/min - 80 N/max

Accessories Lock nut Stop limit nut B ØA B Code G J ØI ØH G J Code M42x1,5 54 8 S24012K M42x1,5 49 57 65 35 S24018K ØA Code.: S24012 M45x1,5 54 8 S24012L M45x2 54 8 S24012 1 3/4-12UNF 54 8 S24012U Stainless steel M42x1,5 54 8 S24012K-VA M45x1,5 54 8 S24012L-VA M45x2 54 8 S24012VA Code: S24018 ØI ØH M45x1,5 49 57 65 35 S24018L M45x2 47 54 65 35 S24018 Square flange ØF ØF E D C Code M42x1,5 9 12 43 55 S24014K D C E M45x1,5 9 12 42 55 S24014L M45x2 9 12 42 55 S24014 1 3/4-12 UNF 9 12 42 55 S24014U Code.: S24014 Foot mounting E D H F C B max G A inklusive * A B max C D E F G H Code 1,5 x 1 M 45 x 2 148 64 12,5 25 80 56 M8 58 S24015 1,5 x 2 M 45 x 2 198 89 12,5 25 80 56 M8 58 S24015 1,5 x 3 M 45 x 2 248 114 12,5 25 80 56 M8 58 S24015 1,5 x 1L M 45 x 1,5 148 64 12,5 25 80 56 M8 58 S24015L 1,5 x 2L M 45 x 1,5 198 89 12,5 25 80 56 M8 58 S24015L 1,5 x 3L M 45 x 1,5 248 114 12,5 25 80 56 M8 58 S24015L

Adjustment The shock absorbers WN-M 1,5 are self-adjusting. The shock absorber will be adapted individually according the technical data of the customer. Installation Foot mounting Clevis mounting Lock nut Foot mounting Clevis mounting Installation with stop limit nut Installation with flange Threads Flange Lock nut Stop limit nut

Safety Instructions Before installation, coissioning, servicing and repair the data sheet is to be noticed. This work may only be performed by trained, introduced staff. Electric connections according to the suitable national regulation. For Germany: VDE regulation VD E0100 Before all repair and servicing works the energy supplies (main switch, etc.) have to be switched off! Moreover, measures are necessary to prevent an unintential reconnect. For example, a warning sign service works or maintenance work, applied to the switch. Designated use Check before installation and make sure the type name on the shock absorber or on the packaging is corresponding with delivery note. Industrial shock absorbers are maintenance-free and ready for installation. Temperature influence: at higher temperatures the shock absorber characteristic will change. Movable loads have to be protected during the installation and maintenance against unintentional processes. In operation outside the allowed temperature range, the shock absorber can lose his function. Due to heat radiation don t paint the shock absorber. Fluids, gases and a dirty environment can affect or destroy the sealing system of the shock absorber. The result could be a failure malfunction. Piston rod and sealing system has to be protected against fluids, gases and a dirty environment. Damages at the piston rod can destroy the sealing system. Don t grease or oil the piston rod. Avoid traction forces on the piston rod to present internal damages. The shock absorber can be pulled out of the construction during the impact.the construction needs to be able to resist the max counterforce. Sufficient security must be calculated. The maximum counterforces performed in the calculation program can vary from the really appearing counter forces, because these are based on theoretical values. Fundamentals Shock absorbers may under no circumstances be: -painted -welded -held with clamps -used on pull* In hazardous environments (dirt, humidity, oil) shock absorbers must be protected against damage and failure with the necessary accessory. If several shock absorbers are used on the same application, the deceleration has to be distributed equally. The Torque (PERFORMANCE) indicates the maximum force by using the flats. The Weforma catalogue shows technical data with maximum values.this shock absorber are used only for a emergency case.

Important Information Installation situation The installation situation is any, however always in such a way that the complete shock absorber stroke can be used. The shock absorbers must be mounted like that the forces in centerinke about the piston rod are initiated. The maximum angle out of centre amounts to 2. With a bigger angle out of centre an AK1 / AK2 (see equipment) must be used. Liability Due to the number of possible uses of our products and the conditions of use that lie outside of our scope of influence, we accept no liability as to whether the purchase object is suitable for the Client s intended purpose. The verification to this effect, in particular the verification as to whether the purchase object is suitable for the planned use, is the responsibility of the Client alone, unless expressly agreed otherwise in writing. For the reasons we accept no liability for the suitability of the purchase object for the purpose intended by the Client, except in cases of intent or gross negligence. With damages, the not designated use and from high-handed, in these instructions do not originate to intended interventions, any guarantee and liability claim goes out towards the manufacturer. Guarantee By non-use of the original spare parts the guarantee claim goes out. Environment protection By the exchange from damaged parts is to be respected to a proper disposal.