Three days training program (Oct 5-7) on. Substation Earthing, Industrial earthing and Neutral earthing. at IEI Mysore, Karnataka India

Similar documents
SYSTEM EARTHING & PROTECTIVE EARTHING

SUBSTATION DESIGN TRAINING

School of Electrical and Information Engineering. ELEC High Voltage. University of Sydney. Dr Keith Mitchell. Engineering

FUNDAMENTALS OF POWER DISTRIBUTION SAIEE-1337-V : 2 CPD credits : Category 1

4-Day Power System Analysis, Coordination, System Studies

Grounding Of Standby & Emergency Power Systems

/12/$ IEEE. M. Bashir M.Sc student, Student Member, IEEE Ferdowsi University of Mashhad Mashhad, Iran

Pretest Module 29 High Voltage Unit 1

White Paper. Ground Fault Application Guide. WL Low Voltage Power Circuit Breakers

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

The Case for Hybrid Generator Grounding

Switchgear and Distribution Systems for Engineers and Technicians

In any of the 5 star hotels. The exact venue will be informed once finalized.

Air-insulated switchgear UniGear type ZS1

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

Power Systems Trainer

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Title High Voltage and 1500 System Earthing References and Definitions. Reference Number PDS 02 (RIC Standard: EP SP)

Earthing Calculation. Contents. Introduction. From Open Electrical

Electrical Power Systems 2014/15

IEEE Northern Canada & Southern Alberta Sections, PES/IAS Joint Chapter Technical Seminar Series

Unified requirements for systems with voltages above 1 kv up to 15 kv

MESG 12 / 17.5 / 24 / 36 KV

CPG.0 Single busbar gas-insulated cubicles

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

NEXT STEP B) SAFETY :

CP Automatic capacitor bank

Have You Been Grounded Lately

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

ELECTRICAL EQUIPMENT : TRANSFORMERS, INVERTERS, RECTIFIERS, UNINTERRUPTABLE POWER SYSTEMS, GENERATORS. UAE, Sharjah, Copthorne Hotel Sharjah

ELECTRICAL POWER and POWER ELECTRONICS

Independent Testing Laboratory for High Voltage Equipment

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

PPHVC Power Quality Solutions. ABB PQC-STATCON Benefits and advantages

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

Advanced Protective Relay Training

REFERENCE CP_TSSPEC_138 0 DATE: JUNE 2006 PAGE: 1 OF 17 TITLE SPECIFICATION FOR POLE- MOUNTED AUTO-RECLOSERS TABLE OF CONTENTS

Interruption Technology of Breakers for High-voltage Direct Current

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

Sales Application Engineering Europe & Russia. Application Engineering Training. Course description and Curriculum

B kv T&D GAS INSULATED SWITCHGEAR

Title Low Voltage Distribution and Installations Earthing References and Definitions. Reference Number PDS 03 (ARTC Standard: EP SP)

AIR CORE REACTORS. Phoenix Electric Corporation

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

On_Disc. 2 o/c1 BS 7671 applies to a lift installations b highway equipment c equipment on board ships d electrical equipment of machines.

PRAGATI ENGINEERING COLLEGE

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Low Voltage Power Supplies in Electrified Areas

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Safe, fast HV circuit breaker testing with DualGround technology

Designing and Maintaining a Pollution-Resilient Electric Power System. Managing Pollution Issues

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay


VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

NXPLUS C Single busbar. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime

Extra-High-Voltage SF 6 Gas-Insulated Switchgear

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

EMPAC Metal enclosed capacitor bank for wind applications

Key elements of the AS3000 Wiring standards and some of the recent changes.

Modular medium-voltage switchgear. NorMax

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

Close-Open (Short-Circuit) Time Results Interpretation

Guidance for Low Voltage Electrical Installations

EE042: Practical Power System Protection for Engineers & Technicians

FUSES. Safety through quality

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Gas Insulated Switchgear ELK-0. for stations up to 170 kv, 4000 A, 63 ka

Technology of Estimating Short Circuit Current and Ground Fault for Direct Current Distribution Systems

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

EE 741 Over-voltage and Overcurrent. Spring 2014

Standby Power Systems

CHAPTER 4 PROTECTION REQUIREMENTS

B kv Gas-insulated Substations

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Voltage limiting device HVL

Power systems Protection course

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Transcription:

Three days training program (Oct 5-7) on Substation Earthing, Industrial earthing and Neutral earthing at IEI Mysore, Karnataka India Training program is helpful for students, Engineers working in Design and projects and Research scholars interested in earthing subject. At the end of the program participants will have awareness about earthing and will be able to do some typical earthing calculations used during plant design.

Trainer: Paneendra kumar BL Training Charges: Rs 3500 (inclusive of taxes) Training material: Shall be provided Certificate: Certificate of attendance shall be issued by VKES. Training Venue: Institution of Engineers Mysore Food for trainees: Simple Vegetarian Lunch Provided at training venue Simulation Software: Not used during this training. Payment terms: 100% in advance. No refund in case of cancellation. Date of Training: 5,6,7 October 2018 Contact: Paneendra kumar BL, 9880784082, vkes@vkes.org Website: www.electricalguideline.com/conference.html

Day 1 - Substation Earthing design 09:00AM to 9:30AM 09:30AM to 10:30AM 10:30AM to 12:00PM 12:00PM to 12:30PM 12:30PM to 02:00PM 02:00PM to 03:30PM Training Contents Trainer and Participants introduction What is earthing Why do we do earthing How to protect a person in a substation against electrical shock What happens during a fault Why fault takes place What happens when the current flows to the ground or earth How earthing of domestic industrial system different from substation What happens during a shock What current does a person feel shock and when does a person die What is the current allowed through human body What should be the value of ts What if weight of person is more or less than 50kg What is the value of Resistance for the current through the body What are the paths in which current can flow into human body Lunch Break Permissible touch and step voltage Correction factor for foot resistance Permissible touch and step voltage with Cs Earthing Grid, what needs to be connected to the earthing Grid Sizing of earthing grid, Fault current distribution (Sf) Decrement Factor, Grid Geometry Mesh Voltage calculation, Step Voltage calculation GPR- Ground potential rise Transferred potential What Causes GPR, Grid Resistance Sample Calculations Case 1: Fault inside substation-design fault current, duration 1sec Case 2: Fault inside a substation-fault current 20.5kA, duration 100ms Fault current distribution

Day 2 - Industrial Earthing design 09:00AM to 10:30AM 10:30AM to 12:00PM 12:00PM to 12:30PM 12:30PM to 02:00PM 02:00PM to 03:30PM What is the function of earthing, Basic requirement before starting the earthing design, Methodology of earthing design, Objective of earthing design, Fault current calculation results, Material of earthing conductor, Earthing conductor sizing, Current density limitation at electrode, Minimum dimensions of conductors, Corrosion, Source earthing of One Generator in isolation, Source earthing of Many Generator in isolation, Source earthing of One Generator parallel with utility, Source earthing of Many Generator parallel with utility, Source earthing of Many Transformers, Transformer neutral earthing, Earthing of UPS neutral Types of earthing based on resistance, Solidly grounded system Unearthed or ungrounded system, Reactance earthed system and resonant earthed system, Resistance earthed system, Types of Resistance earthed system, Different types of LV earthing system (BS 7430), Earth Loop Impedance, Potential gradient around the earth electrode, Earth Resistivity measurement, Resistance of earthing system, Measurement of electrode resistance, What all needs to be earthed, Cable Armour earthing, Cable Tray earthing, Electrical Panel and Distribution boards earthing, Junction Box earthing, Motor and Push button station earthing, Lighting poles and fixtures earthing Tanks, Vessels, Piping earthing, Package equipment earthing Lightning Protection system earthing, Electronic equipment earthing system, Earthing of utility pipes, Earthing of steel reinforced bars of structures and buildings Lunch Break Earthing Schematic, Types of Electrodes and their resistances, Resistance of Plate electrode, Resistance of Rod or Pipe electrode, Resistance of Rod electrodes in parallel, Variation of resistance of electrode due to length and diameter of the rod, Resistance of straight Strip, Resistance of Mesh, Resistivity of electrodes encased in Low resistivity materials, Earthing of steel reinforced concrete foundations, Treated earth electrodes, Auxiliary earth grid, Typical Earthing Layout of LV MV Substations, Layout Requirement, Spacing between electrodes, Distance between electrode and building wall, Depth of horizontal conductor or connecting conductors, Stray Currents Common mode noise, Typical Calculation of Earth electrode resistance of substation, Resistance of Rod electrodes in parallel (BS 7430), Resistance of straight Strip (BS 7430), Resistance of Mesh (BS 7430), Type of joints, Recommended dimensions of earthing Conductor, Typical Earthing design of Oil and Gas installation, Calculation and steps for typical Oil and gas installation earthing design

Day 3- System Neutral Earthing 09:00AM to 10:30AM 10:30AM to 12:00PM 12:00PM to 12:30PM 12:30PM to 02:00PM 02:00PM to 03:30PM Function of Neutral earthing, Inputs required to carry out design, What causes a fault, Coefficient of grounding and Earth fault factor, Type of grounding, Neutral treatment, Selection of type of earthing, Different types of earthing practise used in different sectors, Low resistance grounding, LRNG current rating and protection, Advantages Low resistance earthing of MV system with VFD, Low resistance grounding with Single generators, LRNG typical calculation, Effect of Third harmonics in paralleled Generators on NGR design High resistance grounding, Basics, Sequence network of HRNG system, current limit, History and evolution, Overvoltage and insulation, Charging current contributions, Cause of stray capacitance HRNG for Generators with unit transformer, Fault current circulation after breaker is opened due to field discharge system, Open circuit time constant, NGR/NGT design, Rating of NGT, Specification of NGR and NGT, Basic insulation level, Construction of NGR, Ingress protection, NGR Material, NGR time rating, NGR temperature rise, Temperature coefficient of NGR, Requirement of NGT, Fault current in HRNG, Typical calculation of NGR NGT and Brief specification, Arc hazard eliminated by HRNG, Low Voltage high resistance grounding, Oil mines earthing, HRNG for MV distribution system, NGR failure and its associated problems, Monitoring of NGR with relays, Earth fault Protection for HRNG system, locating fault in HRNG system, Why HRNG used in the beginning with only alarm, Arc energy damage limits Lunch Break Deriving neutral artificially in Ungrounded power system, Zigzag transformer, specification, Calculation of fault current for network with zigzag transformer, Protection methods when using zig zag transformer, Resonant grounding, Different terminology for a group of similar technology, Resonant grounding system for Unit connected Generator, Typical calculation of resonant grounding for Unit connected generators, Resonant grounding for distribution system, Typical application SLD in European distribution system, Fault current of 11kV isolated network and network with Peterson coil, construction, Type of arc suppression coil, Regulator for Peterson coil, Detection of faulty feeder in resonant earthed system, Voltage at the point of fault, Converting Isolated network, System modification requirement- ASC, Temperature rise of reactors, Rating of neutral grounding reactors, Advantage of ground fault current limiters vs phase fault current limiters Active earthing system or Ground fault neutralisers (GFN),Neutral grounding resistor versus Neutral grounding reactor, Type of generator connection and related earthing system, hybrid system, Different types of Earthing of generator and utility system, LV unearthed system, Grounding DC system, Common grounding resistor for generator earthing, Time rating of neutral grounding equipment, Voltage versus Current, Clearing ground fault in definite time, Earthing tripping philosophy fault duration time rating of neutral equipment, Types of earthing system used in generation transmission distribution, Conversion of earthing system, Effect of earthing system on damage overvoltage relay operation, Allowable touch voltage in 11kV system

Local sightseeing in Mysore Stay: We can arrange budget hotels with competitive tariff for stay at Mysore for outstation candidates. Local Site Seeing: We can arrange local transport operator to provide transport facility to take the outstation participants who are interested in local site seeing daily from 3:30PM to 8:30PM Food: We can arrange simple vegetarian Breakfast and Dinner within the hotel. Reaching Mysore: Trainees shall make their own arrangements to reach Mysore Some Places of Interest in Mysore: Chamundi Hills Mysore Palace Jaganmohan palace Mysore Zoo Somnathpur temple Brindavan gardens Shopping: Mysore is famous for Silk sarees, Sandalwood, Traditional items Tariff Hotel: Approx. Rs 1000/day actual cost depends on the hotel. Tariff local sightseeing: Approx. Rs 500/day actual cost depends on tour operator. Local sightseeing,hotel is not part of training and is not conducted by VKES.