MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Similar documents
INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

MARTINDALE MARTINDALE IN2001/IN2003 INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN2001/IN2003 INSULATION & CONTINUITY TESTERS

The insulation tester must only be used by a skilled and competent measuring equipment connected directly to utilization points

1.Safe testing IMPORTANT:

DIGITAL RCD(ELCB) TESTER

OPERATING INSTRUCTION

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

OPERATING INSTRUCTION

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Users Manual. Phase Rotation Indicator

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Rental Industry Safety Tester Safe Check 5s

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

True RMS Autoranging Multimeter

KEWTECH. KT56 digital multi function tester. Instruction manual

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

INSP-3 Wiring Inspection Tester

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

KD1E Range Potential Indicators

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

Autoranging Multimeter

PY-11 Voltage & Continuity Tester

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

KMP Insulation-Continuity Tester. Users Manual

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

SafetyPAT Plus A B P/N:

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Distributor. Kewtech Corporation Limited 76 St. Catherine s Grove Lincoln LN5 8NA KEWTECH

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

OPERATING INSTRUCTION

MIT300 Series Insulation and Continuity Testers

Phase Sequence Tester

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

Autoranging Industrial Multimeter

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

BATTERY OPERATED DIGITAL MILLI-OHMMETER

Digital/Analog Megohmmeter Model 1026 USER MANUAL

DIGITAL MULTIMETER INSTRUCTION MANUAL

Instruction Manual & Specification

operating manual DL7 101 DIGITAL THERMOMETER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

362 Clamp Meter. Users Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

HIGH VOLTAGE PROXIMITY DETECTOR

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Car Battery Charger Instructions for Use

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

OPERATING INSTRUCTIONS

USER MANUAL. Insulation Tester + DMM. Model MG320

User Guide. Model Insulation Tester / Megohmmeter. Introduction

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

OPERATING MANUAL PHASE SEQUENCE AND MOTOR ROTATION DIRECTION TESTER TKF-13

with lcd display 12-42v

Non-Contact Phase Rotation Tester

MODEL No s: PP3, PP3K

Attention ETCR8600 Leakage Protector Tester To read this user manual carefully. To comply with the operating cautions presented in this manual.

Model (Circuit Tester) Model (GFCI Tester)

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

Non-Contact Phase Rotation Tester

Date received into service; / /.

Safety design conforming to the following provisions

Safety design conforming to the following provisions

Digital Multimeter User's Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

OPERATING INSTRUCTIONS

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

Installation manual wall-mounted distributor

USER MANUAL 17TH EDITION MULTIFUNCTION INSTALLATION TESTER. Ethos Test Instruments, Distributed by MTI, Victoria Road, Avonmouth, Bristol BS11 9DB

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

TESTER SET SOCKET & VOLTAGE

Thermocouple Thermometer Models

707Ex. Users Manual. ma Calibrator

LRCD200 Series Combined Loop and RCD Tester USER MANUAL

Instruction Manual. Model 310 Digital Milli-Ohm Meter

Transcription:

4.4 Storage Conditions The FD650/R and FD500/T or FD600/T should be kept in warm dry conditions away from direct sources of heat or sunlight, with the battery removed and in such a manner as to preserve the working life of the FD650/R and FD500/T or FD600/T. It is strongly advised that the unit is not kept in a tool box where other tools may damage it. 4.5 Warranty Faults in manufacture and materials are fully guaranteed for 2 years from date of invoice and will be rectified by us free of charge, provided the unit has not been tampered with, and is returned to us with its housing unopened. Damage due to dropping, abuse or misuse is not covered by the guarantee. Nothing in these instructions reduces your statutory rights. INSTRUCTIONS Other products from Martindale: 16th Edition Testers All-in-one s Calibration Equipment Continuity Testers Electrician s kits Full Calibration & Repair Service Fuse Finders Digital Clamp Meters Digital Multimeters Microwave Leakage Detectors Motor Maintenance Equipment Non-trip loop testers Pat testers & Accessories Phase rotation Proving units Socket Testers Thermometers & Probes Test Leads Voltage Indicators Specialist Metrohm testers (4 & 5kV) Specialist Drummond testers ELITE FUSE FINDER KIT Martindale Electric Company Limited Metrohm House, Penfold Trading Estate, Imperial Way, Watford, WD24 4YY, UK. Tel: +44(0)1923 441717 Fax: +44(0)1923 446900 E-mail: sales@martindale-electric.co.uk Website: www.martindale-electric.co.uk Martindale Electric Company Ltd. 2002 Registered in England No. 3387451. Rev 2. MARTINDALE ELECTRIC Trusted by professionals

SAFETY INFORMATION: Always read before proceeding. WARNING These instructions contain both information and warnings that are necessary for the safe operation and maintenance of the FD650/R and FD500/T or FD600/T. It is recommended that you read the instructions carefully and ensure that the contents are fully understood. Failure to understand the instructions and to comply with the warnings and instructions contained herein can result in serious injury, damage or even death. In order to avoid the danger of electrical shock, it is important that proper safety measures are taken when working with voltages exceeding 30 V AC rms, 42 V AC peak or 60 V DC. The FD650/R and FD500/T FD600/T must only be used under the conditions and for the purposes for which they have been constructed. Particular attention should be paid to the safety instructions, the technical specifications and the use of the FD650/R and FD500/T or FD600/T in dry surroundings. Always check the FD650/R and FD500/T or FD600/T are in good working order before use and that there are no signs of damage to any unit. Do not use if damaged. Keep these instructions for future reference. Updated instructions and product information are available on our website: www.martindale-electric.co.uk Symbols AC (alternating current) Earth ground 3.4.2 Locating Live Wiring/Cabling Switch the FD650/R to VAC and verify the green battery indicator is continuously illuminated. Hold the tip of the FD650/R to the cabling to be tested. Where multi-core cabling is being tested run the tip of the FD650/R along a short length of the cable to overcome the electrical effects of the natural twist in the conductors. If the wiring/cabling is live the VAC bar graph will display an indication and an audible tone will be emitted from the FD650/R. 4.1 Battery Replacement 4. MAINTENANCE Remove the rear battery cover of the FD650/R by unscrewing the battery cover retaining screw. The cover will now lift off. Fit a new 9V, MN1604/PP3 alkaline battery, observing correct polarity. Replace the battery cover and secure with the battery cover retaining screw. 4.2 Cleaning The FD650/R and FD500/T or FD600/T may be cleaned using a soft damp cloth and mild detergent. Do not use abrasives or solvents. Allow to completely dry before using. 4.3 Repair & Service 2 Safety information (refer to the manual) Equipment complies with relevant EU directives There are no user serviceable parts in this unit. Return to Martindale Electric Company Ltd if faulty. Our service department will promptly quote to repair any faults that occur outside the warranty period. 15

Optionally TL88 leads can also be used with the FD600/T. Connect the black crocodile clip to neutral and red to live in that order and then plug the TL88 lead into the FD600/T IEC inlet socket. The green crocodile clip should be clipped to earth as a safety measure. Fig. 6. TL83 Leads Fig. 7. TL88 Leads CONTENTS 1. Introduction 1.1 Description 1.2 Unpacking and Inspection 1.3 Battery Installation 2. Technical Specification 2.1 Transmitter 2.2 Receiver 3.4 Using the FD650/R as a Voltage Detector Ensure you have read the precautions (section 3.1) before proceeding. 3.4.1 Pre-Check of the FD650/R Switch the FD650/R to VAC and verify the green battery indicator is continuously illuminated. If the green battery indicator is flashing the battery is low and should be replaced (see section 4.1). Press the FD650/R TEST button and verify all the segments of the FD650/R VAC bar graph are illuminated and an audible tone is present. Do not use if the pre-check fails. 3. Operation 3.1 Precautions 3.2 Description of Functions and Indicators 3.3 Using the FD650/R and FD500/T or FD600/T as a Fuse Finder 3.3.1 Pre-Check of the FD650/R and FD500/T or FD600/T 3.3.2 Locating a Fuse or Circuit Breaker 3.3.3 Using in Manual Threshold Mode 3.3.4 Using in Automatic Threshold Mode 3.3.5 Connecting the FD600/T using TL83 & TL88 Leads 3.4 Using the FD650/R as a Voltage Detector 3.4.1 Pre-Check of the FD650/R 3.4.2 Locating Live Wiring/Cabling 4. Maintenance 4.1 Battery Replacement 4.2 Cleaning 4.3 Repair & Service 4.4 Storage Conditions 4.5 Warranty N.B. The unit defaults to Manual Mode when switched on (see sections 3.3.3 and 3.3.4). 14 3

1.1 Description 1. INTRODUCTION The FD650/R is a combined AC voltage detector and fuse finder receiver (when used in combination with the FD500/T or FD600/T transmitter). As a fuse finder the FD650/R can be operated with either manual or automatic setting of its sensitivity threshold to find the fuse or circuit breaker that produces the maximum signal. In manual mode the press of a push-button will set the sensitivity threshold to bring the detected signal to mid scale on the bar graph. In automatic mode the FD650/R will automatically set the sensitivity threshold every time a signal of a greater magnitude is detected, to bring it onto the bar graph scale. In either mode the buzzer will continue to sound when a signal is present, even when the signal is too small to be shown on the bar graph due to the sensitivity setting. When in the voltage detector mode the FD650/R employs the bar graph to show the detected signal, and at the same time activates the buzzer. The voltage detector function also has a built in test signal to check the operation of its circuitry. Other features of the FD650/R are Auto Power-down and Low Battery Indication. A three-position switch sets the FD650/R from OFF to either the Fuse Finder or the Voltage Detector functions. A single push-button switch controls all other operations of the FD650/R. 3.3.4 Using in Automatic Threshold Mode With the selector switch set to FIND, hold down the SET button for approximately 2 seconds until the red MODE indicator is illuminated. Hold the FD650/R receiver in close proximity to the box suspected of housing the fuse, or circuit breaker, being sought. If the signal is present an audible tone will be emitted from the FD650/R. Hold the FD650/R against the first fuse or circuit breaker of the box as shown in figure 4. The orientation of the FD650/R in relation to the fuse / breaker must be as shown in figure 4 and it should be held in the centre of the fuse or circuit breaker. The FD650/R will automatically set the sensitivity threshold to show a signal strength indication on the bar graph. The signal strength indication on the bar graph may be centred to display 3 to 4 segments at any time by pressing the SET button. Be sure to check all the fuses/circuit breakers, and then go back over all the fuses/circuit breakers maintaining uniform proximity during and after each pass to prevent incorrect re-setting of the receiver sensitivity. Only one fuse/circuit breaker should now show a signal strength indication on the bar graph. If this is not the case then repeat the above procedure, until only a single fuse/circuit breaker causes an indication. Switch off/remove the fuse/circuit breaker that shows the maximum signal strength and check that the FD650/R bar graph is no longer illuminated and the audible tone is no longer present. Go to the transmitter, if the correct fuse/circuit breaker has been switched off/removed then the red ON indicator should no longer be illuminated. 3.3.5 Connecting the FD600/T using TL83 or TL88 Leads If you are using the FD600/T with TL83 leads to trace wiring, connect the black crocodile clip to neutral and red to live in that order and then plug the TL83 lead into the FD600/T IEC inlet socket. 4 13

Fig. 1. FD500/T Fig. 2. FD600/T with EX332 Mains Lead Figure 4. Correct The receiver must be held in this orientation in relation to the breaker to find the correct fuse/circuit breaker. If the individual breakers were horizontal, the receiver would have to rotated through 90 (in either direction). Fig. 3. FD650/R Figure 5. Wrong 1.2 Unpacking and Inspection Before unpacking the FD650/R and FD500/T or FD600/T, examine the shipping carton for any sign of damage. Unpack and inspect the FD650/R and FD500/T or FD600/T for any damage. If there is any damage then consult your distributor immediately. 1.3 Battery Installation 12 Refer to Section 4.1 for battery installation instructions for the FD650/R. 5

2. TECHNICAL SPECIFICATION 2.1 Transmitter (FD500/T & FD600/T) Nominal supply voltage: 230 V. Frequency range: 30-70 Hz. Switching frequency: Approx 5 Hz. Temperature Range: -10 to 40C non-condensing. Dimensions: Approx 65 x 65 x 50mm. Weight: Approx 60g. Earth leakage: Nil. Power supply: From mains. Power consumption: Approx 1 W. Fuse rating 500 ma. Overvoltage category: Cat III/300V. Pollution degree: 2. Protection class: IP20. Safety: Complies to BS EN 61010-1:1993 2.2 Receiver (FD650/R) Fuse Finder Function Tracing depth for fuse assignment: Sensitivity threshold setting: Up to 10cm, depending on local conditions. Automatic, or manual push button. 3.3.3 Using in Manual Threshold Mode Hold the FD650/R receiver in close proximity to the box suspected of housing the fuse or circuit breaker being sought. If the signal is present an audible tone will be emitted from the FD650/R. Hold the FD650/R against the first fuse or circuit breaker of the box as shown in figure 4. The orientation of the FD650/R in relation to the fuse / breaker must be as shown in figure 4 and it should be held in the centre of the fuse or circuit breaker. Depending on the signal strength the bar graph may be activated. Press the SET button to set the sensitivity and the lower 3 to 4 segments of the bar graph will be illuminated. Move along the row of fuses/circuit breakers, stopping at the centre of each fuse/circuit breaker and noting the signal strength on the bar graph display. Every time this signal causes the bar graph to exceed 3 to 4 segments, press the SET button to set the new sensitivity threshold. Be sure to check all the fuses/circuit breakers, and then go back over all the fuses/circuit breakers. Only one fuse/circuit breaker should now show a signal strength indication on the bar graph. If this is not the case then repeat the above procedure, until only a single fuse/circuit breaker causes an indication. Voltage Detector Function Voltage range: Frequency range: Voltage sensitivity: 40V - 600 V AC. 50 Hz - 1 khz. Table 1 below gives the typical distance at which the FD650 will illuminate the first bar graph segment and activate the buzzer. Switch off/remove the fuse/circuit breaker that shows the maximum signal strength and check that the FD650/R bar graph is no longer illuminated and the audible tone is no longer present when the fuse / circuit breaker location is re-checked. Go to the transmitter, if the correct fuse/circuit breaker has been switched off/removed then the red ON indicator should no longer be illuminated. 6 11

3.3 Using the FD650/R and FD500/T or FD600/T as a Fuse Finder Ensure you have read the precautions (Section 3.1) before proceeding. 3.3.1 Pre-Check of the FD650/R and FD500/T or FD600/T Plug the FD500/T or FD600/T transmitter into a known socket and ensure the red ON indicator is illuminated. Switch the FD650/R receiver to FIND and verify the green battery indicator is continuously illuminated. If the green battery indicator is flashing the battery is low and should be replaced (see section 4.1). Hold the FD650/R in close proximity to the transmitter and verify illumination of the FD650/R SIGNAL bar graph and that an audible tone is present. The number of illuminated segments of the bar graph will depend on the FD650/R position and orientation with respect to the transmitter. Do not use if the pre-check fails. 3.3.2 Locating a Fuse or Circuit Breaker Plug the FD500/T or FD600/T into a socket of the circuit to be traced and ensure the red ON indicator is illuminated. If you are using the FD600/T with TL83 or TL88 leads refer to section 3.3.5. Switch the FD650/R to FIND and verify the green battery indicator is continuously illuminated. When switched to FIND, the FD650/R defaults to the manual threshold mode (see section 3.3.3). The FD650/R can alternatively be operated in the automatic threshold mode (see section 3.3.4). N.B. The unit defaults to Manual Mode when switched on (see sections 3.3.3 and 3.3.4). 10 Table 1. Typical Sensing Distance of Energised Cable Cable Type 115V, 50Hz 230V, 50Hz Flat 1mm 2 Twin & Earth 3mm 23mm 2.5mm 2 Twin & Earth 3mm 23mm Round 1.5mm 2 2mm 18mm General Temperature Range: -10 to 40C, non-condensing. Dimensions: 202 x 32 x 22mm. Weight: Approx 135g (including battery). Protection class: IP20. Power supply: 9V battery, MN1604/PP3, IEC 6LA61 (alkaline only). Low battery level: Approx 6.9V. Auto power down current drain: Typically 20 µa. 3.1 Precautions 3. OPERATION Warning Before use check the FD650/R and FD500/T or FD600/T for cracks or any other damage, and make sure the units are free from dust, grease and moisture. Warning Hold the FD650/R by the bottom of the unit. Do not allow your fingers to go beyond the LED indicators. Warning Do not use if the battery cover is not fitted. Warning Always perform a pre-check on the FD650/R and FD500/T or FD600/T (see sections 3.3.1 and 3.4.1) before use. 7

Caution Where users have a Martindale kit that includes an E-Ze Check Xtra or an E-Ze Test, do not have these or similar types of unit plugged in when fuse finding. Caution Avoid severe mechanical shock or vibration and extreme temperature. Caution Remove the batteries from the FD650/R when not in use for an extended period to avoid corrosion from leaking batteries. 3.2 Description of Functions and Indicators Auto Power Down:- The power down is activated after approximately 5 minutes without a valid signal. The power down mode can only be reset by switching the unit OFF and then on again. In power down mode the typical current drawn is 20µA. The power down function can be deactivated by holding down the press button when switching the unit on. Buzzer:- An internal buzzer is used to inform the user when a signal has been detected. In the fuse finder function the buzzer will continue to sound even if the LED s are not illuminated, provided that a signal is present. Function Selection:- The required function is selected by sliding the threeposition slide switch from OFF to FIND (Fuse Finder) or VAC (Voltage indicator). A bar graph of 6 red LED s on the RHS of the unit is used in both FIND and VAC functions to display the signal strength. 1.3. Low Battery:- If the battery voltage is lower than a pre-set level of 6.9V the Green status LED flashes every 500ms. The battery should be replaced (see section 4.1). 1.4. Push -button Switch:- Used to activate the following functions:- 1.5. Activation of test signal in VAC function. 1.6. Automatic threshold mode in FIND function hold down push-button for 2 seconds. Auto mode bar graph centring momentarily press to set the bar graph indication to the centre of the scale when using the FIND function. Deactivation of battery power down hold down while switching from OFF to FIND or VAC. Manual mode threshold momentarily press to set a new threshold when using the FIND function in presence of signal. Resetting sensitivity threshold - When out of signal range momentarily press to set the sensitivity threshold to the power-up default level when using the FIND function. 1.1. LED s:- There are two status LED s on the LHS of the unit. The top one is green and shows battery status. Continuous illumination means that the battery level is acceptable. Flashing means that the battery should be replaced. 1.2. The red LED is only used for the FIND function and indicates that the unit is in automatic sensitivity mode. 8 9