Strip type fuse-switch-disconnectors

Similar documents
6-0. Product family. LV HRC strip-fuseways

mainly used for power distribution

Vertical fuse disconnects

Vertical fuse disconnects

FUSE-LINKS GAUGE PIECES FUSE BASES SINGLE-POLE FUSE BASES THREE-POLE FUSE BASES LOW VOLTAGE FUSES POWER NEEDS CONTROL

Standardized fuse characteristics

Vertical fuse disconnects

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

mainly used for power distribution

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

vertical fuse switch disconnectors

Fuse switch disconnectors

Ratings: Rated voltage: 690 V a.c. Rated currents: 160 A A

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Fuse switch disconnectors

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Fuse switch-disconnectors

2013 JEAN MÜLLER Products

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

max pole for t=15 ms

INNOZED D0 fuse-bases with touch protection

Product family. D type fuse-links

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

MULTIVERT 250A Size 1, 690VAC

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

FUSE BASES NH FUSE BASES 690V 160A 160A

fuse-links & fuse holders PHOTOVOLTAIC

MOULDED CASE CIRCUIT BREAKERS BC160N

Fuse switch-disconnectors

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Vistop TM isolating switches 63 to 160A

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting

Cylindrical fuse-link

IEC Low Voltage General Purpose Protection

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

new NH fuse-links (HRC) rated rated breaking type current voltage capacity size description price

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

LV HRC fuse switch-disconnectors

INNOZED D0 fuse-bases with touch protection

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Fuse holders and fuses

NEOZED D0 fuse-links gg 400/440VAC

LINOCUR Size D02 63A 230VAC/440VAC

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Switch disconnectors

SWITCH FUSES 3KL71 from 32A to 800A Description

NH-Fuse system Low voltage

Varius SUMMARY OF MODELS

Power distribution components

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

Practical and completely safe

General notes. Operating conditions

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

An innovative technology

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

BETA Fuses and Fuse Systems

Miniature Circuit-Breakers (MCBs)

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

185mm-System power 2500A. Expertise

MC FRAME SIZE 1 / UP TO 160A

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Varius SUMMARY OF MODELS

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

Varius SUMMARY OF MODELS

MULTIVERT 1000A Main Incomer, 690VAC

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

Type Pack size Weight Part no. kg/100 units for undrilled busbars 30, 40, 50, 60 x 10. Dimensions Current Pack size Weight Part no.

CENTRE FEED UNIT UP TO 4000A. Safety

Utilisation category gl/gg 500VAC with combi indicator

Modular contactor for installation into distribution boards

Gas Insulated Switchgear

Low voltage NH knife-blade fuse-links

Miniature Circuit-Breakers (MCBs)

24 k B788 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Horizontal fuse disconnects

CPG.0 Single busbar gas-insulated cubicles

Special Purpose Fuses

MODE - Multiple Occupancy Distribution Equipment Selection guide for low voltage indoor distribution up to 500A

NH DIN Dual Indication Fuse Links

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

NH LOW VOLTAGE a FUSE SYSTEM

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

MS25, MST25, MS20, MST20

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Transcription:

Strip type fuse-switch-disconnectors NV Strip type fuse-switch-disconnector sizes 00, 1, 2, Characteristics of the NV Strip type fuse-switch-disconnectors The NV Strip type fuse-switch-disconnectors are -pole bases of NV fuse cartridges, intended for busbar mounting. A NV Strip type fuse-switch-disconnectors comprises three single-pole connections in one unit. Each contact at an individual phase is connected to the phase on the busbar. The other contacts are fitted with cable connecting terminals or intended for attachment of the following busbar. Use The NV Strip type fuse-switch-disconnectors are mainly used for cable distribution and power supply s, transformer s, where they are connected when electric energy transmission is required. The following rated currents are available: 160 A, 250 A, 400 A, 60 A. Principle of operation The NV Strip type fuse-switch-disconnectors are used in combination with NV fuse cartridges protecting the circuit against shorts. The upper part of the NV Strip type fuse-switch-disconnectors with insulation class IPX is provided with a separate test opening through which the live state can be tested according to DIN VDE 0680, part 5. Design of the NV Strip type fuse-switch-disconnectors The insulated supporting body is made of one piece, the material is polyester reinforced with glass fibres. A silver-plated contact, fitted with tinned extinction chambers, ensures a low power dissipation, optimum thermal characteristics and a high breaking capacity. The contact derived parts are intended for cable connections or for attachment of the next busbar. All the live parts are protected against accidental contacts - in conformity with BVG A2. A special form of the contact part cover ensures a safe insertion and removal of the NV fuse cartridges. Short description The NV Strip type fuse-switch-disconnectors are mostly used for installation into cable distribution cabinets and power supply s - in accordance with IEC/EN 6049-1. The NV Strip type fuse-switch-disconnectors have been tested in accordance with IEC/EN 60947-. They are available for the sizes of fuse cartridges from 00 to, with both single-pole and -pole switching-on. Advantages upper or lower cable connection - as required optimum pull contact direct connection double strip connection up to 1250 A universal cover high breaking capacity low power disipation use of earthing connections modular conctruction Main types of the NV Strip type fuse-switch-disconnectors - characteristics Basically, as shown, there are several types of the NV Strip type fuse-switch-disconnectors: for a -pole switching-in for a single-pole switching-in for attachment directly to a busbar with side contacts for a busbar All the NV Strip type fuse-switch-disconnectors are fitted with new, modern Delta contact s allowing optimum pressure contact between the fuse cartridge and the NV Strip type fuse-switch-disconnectors, resulting in extremely low level of power dissipation and heating-up. All the NV Strip type fuse-switch-disconnectors shown in the catalogue are intended for general usage. Upon request appropriate individual configurations can be designed - in such cases please contact our sales engineers, or call us to the factory. 509

General table of NV strip type-fuse-switch-disconnector-single-pole switching-in switch lever 00 001692010 185 SL00 1P M8 flat connection - screw M8 2,4 00 001692011 185 SL00 1P M8 P flat connection - screw M8 retracable handle 2,4 00 001692012 185 SL00 1P SP.95 V-clip 10-95 mm 2 2,4 1 001692110 185 SL1 1P M10 screw M10 1 001694110 185 SL1G 1P M10 screw M10 1 001692111 185 SL1 1P SP.00 V-clip 25-00 mm 2 1 001694111 185 SL1G 1P SP.00 V-clip 25-00 mm 2 1 001692112 185 SL1 1P SP.240 V-clip 25-240 mm 2 1 001694112 185 SL1G 1P SP.240 V-clip 25-240 mm 2 2 001692210 185 SL2 1P M12 screw M12 2 001694210 185 SL2G 1P M12 screw M12 2 001692211 185 SL2 1P SP.00 V-clip 25-00 mm 2 2 001694211 185 SL2G 1P SP.00 V-clip 25-00 mm 2 2 001692212 185 SL2 1P SP.240 V-clip 25-240 mm 2 2 001694212 185 SL2G 1P SP.240 v-clip 25-240 mm 2 00169210 185 SL 1P M12 screw M12 5,6 00169211 185 SL 1P SP.00 V-clip 25-00 mm 2 5,6 00169212 185 SL 1P SP.240 V-clip 25-240 mm 2 5,6 General tabel of NV Strip type fuse-switch-disconnector-three-pole switching-in connection Description 00 00169204 100 SL00/100 P M8-2 flat connection screw M8 1 00 00169205 100 SL00/100 P SP.70-2 V-clip 10-70 mm 2 1 00 00169202 185 SL00 P M8 flat connection screw M8 2,4 00 0016920 185 SL00 P SP.95 V-clip 10-95 mm 2 2,4 1 00169210 185 SL1 P M10 screw M10 1 00169410 185 SL1G P M10 * screw M10 1 00169211 185 SL1 P SP.00 V-clip 25-00 mm 2 1 00169411 185 SL1G P SP.00* V-clip 25-00 mm 2 1 00169212 185 SL1 P SP.240 V-clip 25-240 mm 2 2 001692000 185 SL2 P SP.00 V-clip 25-00 mm 2 2 001694000 185 SL2G P SP.00* V-clip 25-00 mm 2 2 00169220 185 SL2 P M12 screw M12 2 00169420 185 SL2GM12* screw M12 2 00169221 185 SL2 P SP.240 V-clip 25-240 mm 2 0016920 185 SL P M12 screw M12 5,6 0016921 185 SL P SP.00 V-clip 25-00 mm 2 5,6 0016922 185 SL P SP.240 V-clip 25-240 mm 2 5,6 ** Gamma contact (make short - circuit current 80 ka) NV Strip type fuse-switch-disconnector with current transformer connection Description current transformer 00 00169000 100 SL00/100 P M8 150/5 Kl.1 flat connection, M8 150/5 class 1 1,7 1 00169010 185 SL1 P M10 250/5 Kl.1 screw M10 250/5 class 1,1 2 00169020 185 SL2 P M12 400/5 Kl.1 screw M12 400/5 class 1 4,6 0016900 185 SL P M12 600/5 Kl.1 screw M12 600/5 class 1 4,6 00 00169040 100 SL00/100 P SP.70 150/5 Kl.1 V-clip 10-70mm 2 150/5 class 1 1,7 1 00169050 185 SL1 P SP.00 250/5 Kl.1 V-clip 25-00mm 2 250/5 class 1,1 2 00169060 185 SL2 P SP.00 400/5 Kl.1 V-clip 25-00mm 2 400/5 class 1 4,6 00169070 185 SL P SP.00 600/5 Kl.1 V-clip 25-00mm 2 600/5 class 1 4,6 510 Technical data on page 56

Table of accessories for NV Strip type fuse-switch-disconnector Type Code No. Description busbar connection KS 00/5-10 001691040 busbar thickness 5-10mm 1/ busbar connection KS 12/10 001692460 for size 1,2, adapter DA 185/185 42 001692411 for 185 mm height 42 mm adapter DA 185/100 52 001692412 for 185/100mm, height 52 mm, for 2 x SL00 protection covering of contact connections 001692420 for size 00 ZP 00 HA protection covering of contact connections 001692421 for size 1,2, ZP 12/10HA busbar covering PZ 00/185 001691046 mounting thread M8 busbar covering PZ 00/100 001691047 mounting thread M8 busbar covering PZ 12/185 001691048 mounting thread M12 nameplate NP 00 00169240 for size 00 nameplate NP 12 00169241 for size 1,2, busbar support PP 100/185 001691055 for s 100 mm and 185 mm Deriv. connection OP L 001692440 for size 1,2, double connection DP x2 (6)* 001692450 for size 1,2, double protection cover ZP x2/10ha* 001692422 for size 1,2, double terminal connections SPD 2x x00 00169242 for size 1,2, micro switch MST SL00/100 p 001691050 open/close position of SL micro switch MST SL00 p 001691051 open/close position of SL micro switch MST SL12 p 001691052 open/close position of SL * accessories for assembling: SL 1250 (2 parallel connected fuse-switch-disconnectors) busbar support busbar connection busbar covering adapter micro switch protection covering of contact connections BUSBAR CONNECTION Busbar connections are used for drill-free direct contacting of the strip-fuseways on the busbars. DOUBLE TERMINAL CONNECTION The kit for 1250 A allows 2 strips to be connected at the terminal and or 4 cables per phase to be connected. PROTECTION COVER The terminal compartment and terminal covers provide probesafe frontal protecive covering of the terminal compartment. BUSBARCOVER, SCREW-TYPE The screw-type covers of 100 mm width are fixed at busbars with M12 thread or stud. The covers of 50 mm width are fixed on busbars or adapters with M8 thread. BUSBAR SUPPORT The -pole busbar support is used for the fixing of flat bars at 100 mm and 185 mm distances. DOUBLE CONNECTOR The connector kits are used for parallel switching of 2 strips. NAMEPLATE The plate mount is plugged on the strips at the end face. It allows fitting of an additional plate. When fitted in switch boards, it can also be used as support for a cover. BUSBAR ADAPTERS The adapters are required for combining different strip sizes, e.g. size 00 with sizes 1 to. DERIVED CONNECTION The derived connection enables fuse-protected temporary connections (worksite electrical supply) to size 1 to LV NV stripfuseways. Technical data on page 56 511

Strip type fuse-switch disconnectors type SL00 EK Characteristics of the NV Strip type fuse-switch-disconnectors Strip type fuse-switch disconnector is a three-pole low-voltage switching device which enables safely manual connecting and disconnecting electrical circuits under load, depending on voltage and utilization category. It`s purpose is protection of low voltage electrical equipment against specified overload currents and short circuit currents using fuselinks size 000 (00C), 00. are three-pole switching. Application Strip type fuse-switch disconnectors are intended for: - transformer substation - distribution boards, distribution panels - public lightening cabinets - cable distribution cabinets - industry Mounting Strip type fuse-switch disconnectors can be mounted on 100mm busbar directly and with additional adapters can be mounted also to 185mm busbar. Mounting in vertical and horizontal position. Standards are in accordance with the following s: - IEC 60947-1 - IEC 60947- - IEC 60269-1 - IEC 60269-2 Fuse-switch disconnector strip type, three pole switching Type Code No. [g] p M8 001701500 1,20 1 p BT00 10-70 001701501 1,20 1 p OS00 6-50 001701502 1,10 1 p P00 10-70 00170150 1,10 1 p P002 50 001701505 1,0 1 * strip type fuse-switch disconnectors are used only for 100mm busbar ** is possible to mount on 185mm busbar using special adapters *** for Type of terminals see table of terminal for and **** busbar connection for drill-free direct contacting of the strip type fuseswitch disconnector is not at disposal Table of connections for and Cable terminal drawing Cable terminal type M8 BT00 10-70* OS00 6-50 P00 10-70 P002 50 2 10-70 mm 2 (6-50) mm Clamping cross-section 70 mm (10-70) mm 2 2x50 mm 2 Cu Screw type M8x12 M6 2x(M5x14) 2x(M5x25) 2x(M5x40) Tightening torque 12-15 Nm 4,5 Nm 2,6 Nm 4,5 Nm 4,5 Nm Package * connection type BT00 BT00 10-70 10-70 have have to be to be ordered ordered with with the, the, latter latter excahange excahange is not is possible not possible 512 Technical data on page 59

Additional connections for Type Code No. Connector drawing Suitability OS00 6-50 001701211 Cu* P00 10-70 00170121 * P002 50 001701467 * * cable Type for direct connection is indicated on the connection drawing ** exchange between connection Type is possible RA-1 100/185 Accesories for Type Code No. Description [kg/pc] Package PRS-SL/VL EK 001701470 Protection cover for 0,05 1 connection terminals RA-1 100/185 001701471 Mounting adapter for 0,25 1 185mm busbar, single RA-2 100/185 001701472 Mounting adapter for 0,60 1 185mm busbar, double * PRS-SL/VL EK is needed for additional protection covering when using mountin adapter RA- ** RA-1 100/185 is adapter that is needed if one or have to be mounted on 185mm busbar. With adapter RA-2 100/185 two or can be mounted on 185mm busbar same time. PRS-SL/VL EK RA-2 100/185 Example: Top side connection Pressed nut Screw M8 50mm 100 (185) mm* 100 (185) mm* Pressed nut. Bottom side connection Technical data on page 59 51