SAR/SAS Series Hydraulic Magnetic Circuit Protectors

Similar documents
SAR & SAS Circuit Protectors

QAS/QAL/QFS/QFL Series Quick-Action Fuses

AP/UP, AP/MIL Series Magnetic Circuit Protectors

MDS2 Series. Modular Distribution Systems. Introduction 8-Position Configuration Decision Tables

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

IAX/LUX/LEX Series Low-Depth, Hydraulic-Magnetic Circuit Breakers. Introduction Configurations Delay Curves Operating Characteristics Decision Tables

Features and benefits. Normally open, normally closed contact logic

209/219/229/249/279 Series Magnetic Circuit Protectors

209 Series. Magnetic Circuit Protectors

FR circuit breaker - hydraulic magnetic,

Single Pole Circuit Protectors 67 Multi-Pole Circuit Protectors 68 Printed Circuit Board Mounting 70 Configurations 72 Operating Characteristics 73

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

AP/UP, AP/MIL Series Magnetic Circuit Protectors

PDR circuit breaker - Ground fault Datasheet

RBR circuit breaker - Remote operated

Miniature Circuit Breakers

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

L-Series. Circuit Breaker

4CR SERIES MOTOR STARTING RELAY All Position, Current-Type

AR circuit breaker - Hydraulic magnetic,

G-Series DIN-RAIL CIRCUIT BREAKER

PD-Series Ground Fault Circuit Protection

CX-Series. Circuit Breaker

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

F-Series. Circuit Breaker

G-Series. Circuit Breaker.

F-Series. Circuit Breaker

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

5SP SERIES Refrigeration Package

IAL/IUL/IEL/LEL Series Magnetic Circuit Protectors

8EA SERIES PTC MOTOR STARTERS

ID ID. Series 19. Mechanical Products Company

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Type List. Standard Type. High Power Type

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

General Purpose Relay

Multicolour LED Rocker Switch Panel

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

DD Frame - Series Circuit Breakers

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

THERMOSTAT PROBE PACKAGES: FAST RESPONSE, TINY STAT TM

J-Series CIRCUIT BREAKER

UMBW-UL489 and UL1077 Listed

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

Renewable Energy. Circuit Breakers and Disconnects

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

ER circuit breaker - Hydraulic magnetic,

PB-Series. GFCI/ELCI & Panel Seal

Technical Information

Manual Motor Starters

Single Pole Circuit Protectors 129. Multi-Pole Circuit Protectors 130. BX Style Circuit Protectors 131. High-Current Magnetic Circuit Protectors 132

CR circuit breaker - hydraulic magnetic,

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

2AM/3AM/4AM/8AM SERIES Motor Protector

RWS50B RWS100B RWS150B RWS300B RWS600B

Bulletin 190-M Compact Starters. Selection Guide

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

T75S5D Product Details

LOW VOLTAGE SWITCHGEAR

Standard Interlock Safety Switches

TMC 91H is now TMC 60 C Series

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Miniaturized limit switches

Ordering Information. Text PCB Power Relay G5LE

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Eaton. h y d r a u l i c s. Models and with Pilot Operated Checks

G3PE-Single-phase. Solid State Relays for Heaters

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

250V 24V, 30V, 48V, 100 / 110V, 125V, 200 / 220V DC. 11mA. 2,000V AC / 1min. ±4.5kV, 3 times for each pole (1.2 / 50μs)

Low breaking capacity moulded case circuit breakers

Head Removal Detection Function for Safer Performance

Tmax Molded Case Circuit Breakers

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

TDK-Lambda ZWS300BAF/A

High Current, High Density, Power Connectors

MS-Series. Circuit Breaker

System pro M compact Miniature Circuit Br eakers Description Features

QF(13) - Series Miniature Circuit Breakers

Switching Power Supply

Section. Circuit Breakers Selection Guide...N-2. NRA Series...N-3. NRBM Series...N-13. NRC Series...

C&K 1000 Series Miniature Slide Switches

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Industrial Relay KML(1C, 2C)

H-Series. Circuit Breaker.

Bussmann series Quik-Spec Power Module Switch elevator disconnect

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Transcription:

SAR/SAS Series Hydraulic Magnetic Circuit Protectors INTRODUCTION The Airpax SAR and SAS circuit protectors provide protection from over-current conditions in an ultracompact package. The SAR and SAS are the standard products, the SUR and SUS have both U and CSA approvals, and the SER and SES carry U, CSA and TÜV approvals. Typical applications include tight spaces in radio signal amplifiers for base transceiver stations, uninterruptible power supplies, thin-type power supplies, office equipment, and entertainment equipment. FEATURES Ultra-compact and ultralight circuit protectors with reinforced insulation and an electromagnetic safety system Smallest hydraulic 20A rating circuit protector (SAR) and 15A rating circuit protector (SAS) in the world Trip-free function, smooth handle action Conforms to IEC950 Specifications Maximum Rated Current / Voltage Number of Poles 20A (125 VAC), 15A (250VAC, 32VDC), 30A (50VDC) SAR(M), SUR(M), SER(M) = 1 to 2 poles SAS(M), SUS(M), SES(M) = 1 pole Operating Temperature -25 C to 65 C Operating Humidity up to 85% Breaking Capacity 500 amps (in accordance with UL 1077 & EN60934) Insulation Resistance At least 100M with 500VDC megger Dielectric Strength VAC 50/60 Hz 1500VAC for 1 minute ( U/ CSA/general products), VAC 50/60 Hz 3000VAC for 1 minute (TÜV products) leakage current 1mA or less. Auxiliary switch: VAC 50/60 Hz 500VAC for 1 minute Vibration Resistance Approximately 98m/s2 (10G) (Mil-STD-202 Method 201A @ I n ) Shock Resistance 490m/s2 (50G) (Mil-STD-202 Method 213 test condition A @ I n ) Operational Life At least 10,000 times (6 times per minute, ON-OFF 6,000 times @I n, 4,000 times under no-load condition) Approvals *Agency approvals: Pending 237 AIRPAX Additional Products - SAR/SAS Series - Circuit Protectors

ADDITIONAL PRODUCTS RATINGS Circuit Breaker Maximum Rated Current / Voltage 32VDC 50VDC 125VAC 250VAC Breaking Capacity SAR, SUR, SER 20 amps 20 amps 15 amps 500 amps SARM, SURM, SERM 15 amps, 30 amps* 15 amps, 30 amps* 300 amps SAS, SUS, SES 15 amps 15 amps 15 amps 500 amps SASM, SUSM, SESM 15 amps 15 amps 300 amps SAS SAR AIRPAX Additional Products - SAR/SAS Series - Circuit Protectors 238

DIMENSIONAL DRAWINGS ( ) LOAD 2 x.031 (0.8).244 (6.2) *Outline drawings show quick connect specifications. Dimensions = in (mm) 30º ON Marking (dimple).248 (6.3) 1.181 (30) 1.031 (26.2) 1.528 (38.8).969 (24.6) (+) LINE.413 max (10.5) 1.283 (32.6).094 (2.4).394 (10).748 (19) 1.378 (35).591 (15) 1.260 (32).669 (17) *Outline drawings show PCB mount. Dimensions = in (mm) LINE 1.106 (28.1).669 (17) 2 x.020 (0.5).020 (0.5) ON.236 (6).319 OFF (8.1).138 (3.5).138 (3.5).039 (1) 1.161 (29.5).110 (2.8) 2 x.031 (0.8) 1.035 (26.3).118 (3) 1.209 (30.7) 1.181 (30).177 (4.5) LOAD 239 AIRPAX Additional Products - SAR/SAS Series - Circuit Protectors

(handle side, left) Pole 1 (handle side, right) Optional Pole 2 (*2) (handle side, left) Pole 1 (handle side, right) Optional Pole 2 (*2, *3) ADDITIONAL PRODUCTS DECISION TABLES SAR - F - 1RE 1-51 - 10A - 52F - 5A - BWT - AC 7 AC Seventh Decision Remarks Switch type - service circuit AC 1 First Decision Model SAR General Product SUR ЯU / CSA approved SER ЯU / CSA / TÜV approved SARM General Product with magnet SURM cяuus approved with magnet SERM cяuus / TÜV approved with magnet SARM, SURM, SERM: note terminals have porlarity, LINE connect to (+) SAS General Product SUS ЯU / CSA approved SES ЯU / CSA / TÜV approved SASM General Product with magnet SUSM ЯU / CSA approved with magnet SESM ЯU / CSA / TÜV approved with magnet SASM, SUSM, SESM: note terminals have porlarity, LINE connect to (+) 3 Third Decision Circuit type Select 2 options**** 0 Switch type Switch type with 0RE auxiliary switch 1 Series type 1RE 1RS 3 4 auxiliary switch alarm switch Parallel type (SAR, SUR, SER, SARM, SURM, SERM only) Relay type (SAR, SUR, SARM, SURM, only) When the auxiliary switch or alarm switch is a gold contact, G is added to the symbol. For example 1REG 4 51 52 61 62 SP Fourth Decision Trip Delay VDC medium speed VDC low speed VAC medium speed VAC low speed Relay type for voltage trip (SAR, SUR, SARM, SURM, only) If an inertial wheel is required, add F to the end of the code. Example: 62F If any switch type was selected in the 3rd decision, do not choose a trip delay (4th decision) 5 Fifth Decision Rated current* 0.1A 0.5A 1.0A 2.0A 3.0A 5.0A 7.5A 10.0A 15.0A 20.0A 25.0A 30.0A DC A, B, D Switch type - service circuit DC PCB type Chose A, B, or D (SAR, SUR, SER, SARM, SURM, SERM only) 6 Sixth Decision Handle marking (*1) No mark standard Use the options below for: SAR, SUR, SER, SARM, SURM, SERM only BWT RWT Black handle Red handle On Off BWY Black handle On Off RWY Red handle BWO Black handle On Off WBO White handle On Off GUARD Handle Guard 2 F P Second Decision Terminal type 0.25 quick connect terminals ( only) PCB - PC board terminals *Rated current depends on the circuit type & circuit voltage Circuit Switch type with Voltage auxiliary switch 125VAC Main = 20A max 250VAC Main = 15A max 32VDC Main = 15A max 50VDC Main = 30A max (*4) alarm switch 0.1 to 20A 0.1 to 30A (*4) Parallel type 0.1 to 20A ---- Relay type ---- *1.) This decision only applies to: Disregard sixth decision for: *2.) 2-pole options are only available for: Disregard the pole 2 option for: *3.) If the same specifications are required in the 4th and 5th decision for each pole in a 2-pole device (example, both poles require 51-10A), do not enter a Optional Pole 2 entry into the 4th and 5th decision. Example: SAR-F-1RE 1-51 - 10A both poles need 51-10A *4.) SARM - 50VDC, 30A max SURM/SERM - 50VDC, 15A max AIRPAX Additional Products - SAR/SAS Series - Circuit Protectors 240

This document is generated from the AIRPAX full-line catalog #2455005000 printed in USA, January 2011 BUSINESS CENTERS Sensata Technologies 807 Woods Road Cambridge, MD 21613, USA Phone: +1 410-228-1500 Brands: Airpax Sensata Technologies Inc. 529 Pleasant Street Attleboro, MA 02703, USA Phone: +1 508-236-3287 Sensata Technologies 4467 White Bear Lake Parkway St. Paul, MN 55110, USA Phone: +1 800-553-6418 Brands: Dimensions Sensata Technologies Holland B.V. Kolthofsingel 8 7602 EM Almelo, The Netherslands Phone: +31 546 87 95 55 Sensata Technologies China Co., Ltd. Novel Plaza, 8th Floor 128 Nanjing Road West Shaghai, 20003 People s Republic of China Phone: +86 21 23061500 Sensata Technologies Korea Ltd. 29F, Trade Tower 159-1 SamSung-Dong, KangNam-Ku, Seoul 135-729, Korea Phone: +81-2-551-2918 Sensata Technologies Japan Ltd. 305, Tanagashira Oyama-cho, Sunto-gun, Shizuoka-ken Japan, 410-1396 Phone: +81 550 78 1211 Sensata Technologies Nihon-Airpax 6-3, Chi Yoda 5 Chome Saitama-Ken Japan, 350-0214 Phone: +81 492 83 7575 Brands: Airpax Important Notice: Sensata Technologies (Sensata) reserves the right to make changes to or discontinue any product or service identified in this publication without notice. Sensata advises its customers to obtain the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current. Sensata assumes no responsibility for infringement of patents or rights of others based on Sensata applications assistance or product specifications since Sensata does not possess full access concerning the use or application of customers products. Sensata also assumes no responsibility for customers product designs.