RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Similar documents
RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Pump Safety Block Model DBA... / DBAW, Series 1X

29 160/ Proportional Pressure Relief Valve Model DBE, (Series 5X) Ordering Code DBE 5X Y G24 1/ PSI (350 bar)

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

Pressure reducing valve, pilot operated Type DR

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Pressure reducing valve, direct operated

RA / /3, 4/2 and 3/2-Way Directional Valves Model.WE 10.../.D, Series 3X with Wet Pin DC Solenoids. Functional description, section

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Pipe burst safety valve Type MHRB

Pressure sequence valve pilot operated

RC /

Gear Pump Model G4, Series 2X

Pipe burst safety valve

Pressure relief valve, pilot operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure reducing valve, direct operated

Fixed Displacement Motor AA2FM (A2FM)

Pressure reducing valve, pilot operated

Pressure relief valve, pilot operated

RA / Radial Piston Motor Model MR, MRE Fixed Displacement. Table of Contents. Replaces: RA /10.95

Pressure reducing valve, direct operated

SR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design

VRN2-10. Functional Description HA /2008. Pilot Operated Pressure Reducing Valves. Replaces HA /2003

Pressure Control Valves

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Pressure relief valve, pilot operated

Check valve, pilot operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Check valve, pilot operated

Pilot operated pressure relief valve

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

VJO1-06/S. Functional Description HA /2010. Check Valves. Replaces HA /2008. Size to 06 (1/4) bar (4600 PSI)...20 L/min (5.

Pressure Reducing Valve Direct Operated

Check valve, pilot operated

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Check valve, pilot operated

Check valve, pilot operated

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

Proportional pressure relief valve, pilot operated

Throttle and throttle check valve

Double throttle check valve Type Z2FS 10

RNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

Hydraulic inch power brake valve LT 31

VPN1-06. Functional Description HA /2008. Pilot Operated Pressure Relief Valves. Replaces HA /2002

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Hydraulic pilot control units for armrest installation

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

Pressure relief valve, pilot operated

2-way flow control valve

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Hydraulic Motor (Radial piston multi-stroke)

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Pressure Relief Valves

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Flow sharing control block in sandwich plate design M7-25

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Check-Q-meter type FD

RE / Central Hydraulics Valve LT43 for Tractors with Priority Function for Steering and Trailer Brake and Pilot Oil Valve.

Pressure reducing valve, direct operated, with pressure monitoring

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

NG06. General Size NG6 NG10 Design

LUDV control block in mono block/sandwich plate design M7-20

Pressure sequence valve, direct operated

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Hydraulic remote controls

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

Proportional pressure reducing valve, pilot operated

Flow sharing control block in mono block / sandwich plate design M6-22

Proportional pressure reducing valve of 3-way design

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

Solenoid directional valves type DPHI, DPHU

Modular valves DO5 (NG 10) 315 bar

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

VER03MP CONTINENTAL HYDRAULICS PROPORTIONAL PRESSURE RELIEF VALVES PILOT OPERATED VER03MP - PROPORTIONAL PRESSURE RELIEF VAVLES PILOT OPERATED

SD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Proportional Electro-Hydraulic Relif and Flow Control Valves,Type PQ10-20/ Huade América 1

FLOW CONTROL VALVES A5-1 PN# / / ACC

4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections

Transcription:

R 26 892/06.98 Pressure Reducing Valve, Pilot Operated Model DR (Series 5) Size 10 to 0... 5000 PSI (50 bar)... 105 GPM (400 L/min) R 26 892/06.98 Replaces: 05.94 Pilot operated pressure reducing valve Threaded in-line, manifold, or subplate design Mounts on standard ISO 5781-06, 08 or 10, NFP/NSI P 06, P 08 or P 10 interfaces Four pressure ranges available, to 5000 PSI (50 bar) Optional built-in reverse free-flow check valve Four pressure adjustment options Hand knob Screw adjustment with locknut and protective cap Key lock hand knob with scale Hand knob with scale K 4660-9 Model DR20-5-5/15.. Ordering code DR 5 * Pressure reducing valve = DR Complete valve = no code Pilot valve only (do not state size or mounting type) = C Pilot valve with cartridge assembly for manifold mounting (state valve size 0, not mounting type) = C Subplate mounting Ordering NFP/NSI Subplates code interface available standard SE, NPT, SP 10 P 06 /8" and 1/2" 20 P 08 /4" and 1" 0 P 10 1-1/4" and 1-1/2" Threaded in-line connections G 10 1/2" -8; /4-16 15 /4" -; 1-1/16-20 1" -16; 1-5/16-25 1-1/4" -20; 1-5/8-0 1-1/2" -24; 1-7/8- Subplate mounted = no code Threaded housing for in-line mounting = G djustment mechanism Hand knob = 4 Screw adjustment with locknut and protective cap = 5 Key lock hand knob with scale = 6 1) Hand knob with scale = 7 1) Key (Part No RR00 008 158) is included with valve 2) (only available in model without check valve) Further details to be written in clear text no code = SP threaded housing = SE threaded housing (standard) no code = NR seals, suitable for petroleum oils (HM, HL, HLP) V = FPM seals, suitable for phosphate ester fluids (HFD-R) no code = With reverse free-flow check valve (only for subplate mounted valves) M = Without reverse free-flow check valve = Internally piloted; externally drained Maximum pressure setting 50 =... 725 PSI (50 bar) 100 =... 1450 PSI (100 bar) 200 =... 2900 PSI (200 bar) 15 =... 4600 PSI (15 bar) 50 =... 5000 PSI (50 bar) 2) 5 = Series 50 to 59 (50 to 59; externally interchangeable) 1/8

R 26 892/06.98 Functional description Models DR are pilot operated pressure reducing valves. They reduce pressure in a branch circuit lower than that of the main circuit. This valve design is capable of maintaining a precise pressure setting even at high flows, since the pilot signal is supplied from the secondary side, (via orifices 4 and 7). These reducing valves consist of main housing (1) pilot valve (2) and main cartridge assembly (). The reducing valve is normally open permitting flow from port to through main spool (1). Until the pressure setting of the pilot section (2) is reached, system pressure is maintained above the main spool (1) via passageways (8), (5) and orifice (4). The main spool is hydraulically balanced and the spring in chamber () holds main spool (1) open. When pressure increases beyond the set value of spring (11), pilot ball (6) opens, allowing orifices (4), (7) and (10) to maintain flow over pilot ball (6). When pressure in the branch circuit, (pressure at port ), exceeds the set value of spring (11) plus the spring force in chamber (), main spool (1) begins to close thereby orificing flow of fluid to port. Main spool (1) then modulates to maintain the set pressure at port. Pilot valve spring chamber (14) must be drained externally via passage (15), or port in pilot valve (2). n optional reverse free flow check valve (16) is available if required. 9 10 6 11 14 2 5 1 4 8 7 1 15 17 a Model DR..-4-5/... without check valve with check valve 16 a - a Symbols DR..-.-5/...M.. DR..-.-5/... (subplate mounting only) 2/8

Technical data (For applications outside these parameters, please consult us!) R 26 892/06.98 General Mounting position Optional Weight (approx.) Valve size 10 15 20 25 0 Subplate mounted DR lbs (kg) 7.5 (.4) 11.7 (5.) 17.7 (8.0) DRC lbs (kg) 2.7 (1.2) DRC 0 lbs (kg). (1.5) Threaded connections DR..G.. lbs (kg) 11.7 (5.) 11.5 (5.2) 11. (5.1) 11.0 (5.0) 10.6 (4.8) hydraulic Inlet pressure, port PSI (bar)... 4600 (15) * Outlet pressure, port PSI (bar) 145... 4600 PSI (15) * ackpressure, port PSI (bar)... 4600 (15) * Setting pressure minimum PSI (bar) Q-related, see operating curves page 4 maximum PSI (bar)... 725 (50),... 1450 (100),... 2900 (200),... 4600 (15),... 5000 (50) * Maximum flow Valve size 10 15 20 25 0 Subplate mounting GPM (L/min) 9.6 (150) 79.2 (00) 105.7 (400) Threaded connections GPM (L/min) 9.6 (150) 79.2 (00) 79.2 (00) 105.7 (400) 105.7 (400) Hydraulic fluid Petroleum oils (HM, HL, HLP); Phosphate ester fluids(hfd-r) Fluid temperature range F ( C) NR seals; 22... 176 ( 0... 80) FPM seals; 4... 176 ( 20... 80) Viscosity range SUS (mm 2 /s) 60... 710 (10... 800) Maximum degree of fluid contamination Class 18/15 according so ISO 4406. Therefore, we recommend a filter with a retention rate of ß 10 75. *... 5000 PSI (50), only in model without check valve /8

R 26 892/06.98 Performance Curves, measured at ν = 190 SUS (41 mm 2 /s) and t = 2 F (50 C) (50) Secondary pressure vs. flow Reduced pressure p in PSI (bar) Outlet pressure p in PSI (bar) (15) 4600 (00) 4500 (250) (200) (150) (100) (50) (16) (14) () (10) (8) (6) (4) (2) 750 000 2250 1500 750 225 200 175 150 5 100 75 50 25 Size 10 Size 20 Size 0 (50) (100) (150) (200) (250) (00) (50) (400) Minimum adjustable pressure setting (p min ) vs. flow Q ( ) (Drain to 0 PSI reference) 1 2 p min Size 10 Size 20 Size 0 Power limit (system dependent) 1 = Size 10 2 = SIze 25 = Size 0 (50) (100) (150) (200) (250) (00) (50) (400) Note: p = pressure at port (14) 200 Minimum p over valve vs. flow Q ( ) Pressure difference p in PSI (bar) () (10) (8) (6) (4) (2) 175 150 5 100 75 50 25 Size 10 Size 20 Size 0 (50) (100) (150) (200) (250) (00) (50) (400) 4/8

Performance Curves, measured at ν = 190 SUS (41 mm 2 /s) and t = 2 F (50 C) R 26 892/06.98 Pilot flow vs. system flow ( ) as related to p over reducing valve 0.45 Control flow in GPM (L/min) (1.5) (1.0) (0.5) 0.40 0.5 0.0 0.25 0.20 0.15 0.10 p = 200 bar Size 10 Size 20 p = 50 bar Size 2 0.05 (50) (100) (150) (200) (250) (00) (50) (400) (0) Pressure drop across check valve, during reverse flow Pressure difference p in PSI (bar) (25) 75 (20) 00 (15) 225 (10) 150 (5) 75 Size 10 Size 20 Size 2 (50) (100) (150) (200) (250) (00) (50) (400) p over reverse flow check with main cartridge closed p over reverse flow check with main cartridge fully open 5/8

R 26 892/06.98 Unit dimensions, Pressure reducing valve, subplate mounted: dimensions in inches (millimeters) 0.098 (2.5) L1 L2 L4 L L5 L6 0.08 (2) 1 2 1 L7 L8 L9 L10 4.64 (118) 4. (110) 1.929 (49) Ø 0.4 (11) 5 1.142 (29) 4 5.71 (145) 11 1 Name plate 2.1 Port for external drain 2.2 Port optional for external drain SE-4; 7/16-20 (G 1/4")/0.47 () deep Port for external pilot, (non functional) 4 djustment mechanism 4 5 djustment mechanism 5 6 djustment mechanism 6 7 djustment mechanism 7 9 djustment nut 10 mm /F 10 Space required to remove key 11 Locating pin 4) valve mounting holes for DR 10 and 20 6) valve mounting holes for DR 0 1 Optional pressure gauge connection DRC, DRC 0 mounting Subplate (see R 45 064) G 51/05(1/4" NPT) G 51/ (SE-4; 7/16-20) Mounting bolts: 4) 5/16-18 UNC x 1 1/2" (M8 x 40) socket head cap screw (SE grade 8 or better) tightening torque 27 lb-ft (7 Nm). Subplate and valve mounting bolts must be ordered separately. Porting pattern to ISO 6264-08 or 10, NFP/NSI P 08 or P 10 Subplate for, Valve size 10: G 460/05 (*/8" NPT), G 460/ (*SE-6; 9/16-18), G 461/05 (*1/2" NPT), G 461/ (*SE-8; /4-16) 6.65 (169) 0.7 (18) 5 9 4 6; 7 10 Ø 1.8 (5) 0.787 (20) Ø 1.55 (9.5) 8 2 1 0 9 Ø 1.26 (2) H1 6/8 0.098 (2.5) 0.629 (16) SE-4; 1/16-20 Ø 0.26 (6) (G 1/4")/0.47 () deep Note: /F = across flats Required surface finish of interface when mounting the valve without our subplate 1 0.0004/4.0 in 0.01/100 mm 2 (R max 4) H H2 Valve size 20: G 4/ (*SE-; 1-1/16-), G 41/ (*SE-16; 1-5/16-) Valve size 0: G 414/ (*SE-20; 1-5/8-), G 415/ (*SE-24; 1-7/8-) * = and ports, all and ports (1/4" NPT) or (SE-4; 7/16-20) Valve mounting bolts for Valve size 10: 4) /8-16 UNC x 2" (M10 x 50) tight. torque = 50 lb-ft (69 Nm) Valve size 20: 4) /8"-16 x 2-1/4" UNC (M10 x 60) tight. torque = 50 lb-ft (69 Nm) Valve size 0: 6) /8"-16 x 2-/4" UNC (M10 x 70) tight. torque = 50 lb-ft (69 Nm) Socket head cap screws SE grade 8 or better subplates and valve mounting bolts must be ordered separately, see R 45 062 Model L1 L2 L L4 L5 L6 L7 L8 DR 10.779 (96) 1.97 (5.5) 1.299 () 1.689 (42.9) 0.846 (21.5) 0.28 (7.2) 0.846 (21.5) DR 20 4.567 (116) 1.476 (7.5) 1.94 (5.4) 2.74 (60.) 1.56 (9.7) 0.47 (11.1) 0.811 (20.6) DR 0 5.708 (145) 1.299 () 1.17 (29.8).15 (84.2) 2.42 (59.5) 1.657 (42.1) 0.657 (16.7) 0.968 (24.6) Model L9 L10 1 2 4 5 H1 H2 H O-ring O-ring Ports, Ports, DR 10 1.252 (1.8) 1.409 (5.8).46 (85) 1.968 (50) 2.626 (66.7) 2.15 (58.8) 0.11 (7.9) 4.409 (1).622 (92) 1.102 (28) 17. mm x 2.62 mm 9.25 mm x 1.78 mm DR 20 1.752 (44.5) 1.97 (49.2) 4.016 (102) 2.42 (59.5).6 (79.4) 2.874 (7) 0.252 (6.4) 4.80 (2) 4.016 (102) 1.496 (8) 28.17 mm x.5 mm 9.25 mm x 1.78 mm DR 0 2.468 (62.7) 2.657 (67.5) 4.724 (0) 2.992 (76).811 (96.8).65 (92.8) 0.150 (.8) 5.118 (10) 4. (110) 1.811 (46) 4.52 mm x.5 mm 9.25 mm x 1.78 mm 2.2 2.1

Unit dimensions, Pressure reducing valve, threaded connection Model G : dimensions in inches (millimeters) R 26 892/06.98 1.150 (80) Ø 2.85 (72) 6.65 (169) 0.7 (18) 5.71 (145) 4.64 (118) 0.08 (2) 1.929 (49) 4. (110) 5 9 SE-4; 1/16-20 (G 1/4")/0.47 () deep 2 4 6; 7 10 Ø 1.8 (5) 0.787 (20) Ø 1.55 (9.5) 8 2 1 0 9 Ø 1.26 (2) 5.276 (14) Ø 0.984 (25) SE-4; 7/16-20 (G 1/4")/0.47 () deep 1 1.72 (44) T1 0.09 (1) D1 Ø D2 2.85 (72) 0.216 (5.5) 0.157 (4).54 (90) 0.669 (17) D1 T1 0.09 (1) 0.4 (11) Ø D2 1.850 (47) 2.205 (56) 4.488 (114) Model D1 ØD2 T1 DR 10 G SE-8; /4-16 UNC 1.8 0.551 (1/2" SP) (4) (14) DR 15 G SE-; 1-1/16- UNC 1.65 0.60 (/4" SP) (42) (16) DR 20 G SE-16; 1-5/16- UNC 1.850 0.708 (1" SP) (47) (18) DR 25 G SE-20; 1-5/8- UNC 2.28 0.787 (1-1/4" SP) (58) (20) DR 0 G SE-24; 1-7/8- UNC 2.559 0.866 (1-1/2" SP) (65) (22) 1 Name plate 2 Port for external drain 4 djustment mechanism 4 5 djustment mechanism 5 6 djustment mechanism 6 7 djustment mechanism 7 9 djustment nut 10 mm /F 10 Space required to remove key Valve mounting hole 1 Optional pressure gauge connection Note: /F = across flats 7/8

R 26 892/06.98 Unit dimensions, Pressure relief valve, manifold mounting pilot valve with (DC 0) or without (DC) cartridge assembly: dimensions in inches (millimeters) 0.08 (2) 1.260 (2) SE-4; 7/16-0.452 (11.5) 0.26 (6) 1.102 (28) 1.929 (49) 2.401 (61) 2.007 (51) 1.476 (7.5) 1.78 (5) 1 4. (110) 2.2 Ø 0. (8.4) 4.64 (118) 1.72 (44) 2.1 1.2 (28.5) 1.142 (29) 5.71 (145) 1 Name plate 2.1 Port for external drain 2.2 Port optional for external drain 4 djustment mechanism 4 5 djustment mechanism 5 6 djustment mechanism 6 7 djustment mechanism 7 9 djustment nut 10 mm /F 10 Space required to remove key Valve mounting hole 14 O-ring 9.25 mm x 1.78 mm R-ring 9.81 mm x 1.5 mm x 1.78 mm 15 Main cartridge assembly 16 Drilling can connect to drilling at any position. However, care must be taken not to damage port or the valve mounting holes. 17 Insert back-up ring and O-ring before installing cartridge Note: /F = across flats 6.65 (169) 0.7 (18) 5 9 4 6, 7 10 1.575 (40) 1.142 (29) Ø 0157 (4) 2) 45 2) 45 14 15 22 1.142 ±0.008 (29 ±0.2 ) 1.024 ±0.008 (26 ±0.2 ) Ø 1.771 (45) Ø1.260 +0.001 0.0 (2+0.025 ) 0.0 0.00 (0.008) Ø 0.002 (0.05) Z Z 1.2 +0.004 (28.5 +0.1 ) Z 20 21 18 19 2) 0 1.004 (25.5) Z Ø 1.8 (5) Ø 0.157 (4) 0.669 (17) 0.787 (20) 0.0004/4 in 0.01/100 mm 1.8 (4) Ø 1.26 (2) Ø 1.575 +0.004 (40 +0.1 ) Ø 1.654 +0.002 +0.004 (42 +0.1 +0.05 ) 2.027 ±0.004 (51.5 ±0.1 ) Ø 1.55 (9.5) 18 O-ring 28. mm x 1.78 mm* 19 O-ring 27. mm x 2.4 mm* 20 O-ring 28.24 mm x 2.62 mm* 21 ack-up ring 8 024 29.0 mm x 1.5 mm 22 ack-up ring 2 mm OD x 28.4 mm ID x 0.7 mm 2 Cartridge assembly includes orifice and main poppet 0.0008 (0.02) 1.889 (55) 1.260 (2) 8 2 1 0 9 2.007 (51) 0.629 (16) Ø 1.26 (2) 4) mounting bolts must be ordered separately and torqued to 27. lb-ft (7 Nm) * = included 1.72 (44) max. R 0.011 (0.) Ø 0.26 (6) M4; 0.24 (6) deep Ø 0.709 (18) Ø 0.976 +0.008 (24.8 +0.2 ) Ø 1.260 (2) 17 16 x y 6 = (R z 8) 2 = (R z 4) 2.401 (61) 4) 5/16-18x1-1/2" UNC bolts (M8x40)/ 0.47 () deep View "Z" 2 z = 5 (R z 16) 8/8 Mannesmann Rexroth Corporation Rexroth Hydraulics Div., Industrial, 215 City Line Road, ethlehem, P 18017-211 Tel. (610) 694-800 Fax: (610) 694-8467 Rexroth Hydraulics Div., Mobile, 1700 Old Mansfield Road, Wooster, OH 44691-094 Tel. (0) 26-400 Fax: (0) 26- ll rights reserved Subject to revision Printed in U.S..