Solenoid Operated Directional Valve

Directional Controls

Servo-Performance Proportional Directional Valves with Feedback Pressures to 315 bar (4500 psi) KBSDG4V-5 1* Series

Solenoid Operated Directional Valve

Mobile Directional Valve. Product Catalog MDG for Mobile Equipment Flows to 60 I/min (15.8 USgpm)

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Eaton. Revised April, Directional Control Valves. Model 30540, 15 GPM Directional Control Valves. We Manufacture. Solutions

Mobile Valves Proportional - Load Sensing

MDG Mobile Directional Valve Build Kit. MDG for Mobile Equipment Flows to 60 I/min (15.8 US gpm)

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

Directional Controls

XCEL80 Steering Control Units

ISO 4401 size 07; 315 bar (4500 psi); up to 200 L/min (53 USgpm) General Description

Directional Controls

Directional Controls

Directional Control Valve Series 4D01 (DENISON)

Service Data Vickers. Directional Valves. Wet Armature Solenoid Operated Directional Control Valves DG4V4-01, 1* /EN/0799/S

D03 FluiDyne Valves. ENGINEERING DATA

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Directional Control Valve Series D1VW

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

EV FT3 ES-FT5 ES/GB :09 Pagina 4 FT3 ES* 4

General Specifications DRV DRV-Exm DRV-Exd

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Pilot-Operated Directional Control Valves Series D3 - D11

Fixed Displacement Swing Drive Motor. JMF Axial Piston Motor Peak Pressure: 385 bar Displacement 29~250 cc/r

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Proportional Valves. Proportional Two-Stage Directional Valves

Ultronics ZTS16 Twin Spool Valve

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

SM4-30 Servovalves Flows to 113 l/min (30 USgpm) Pressures to 140 bar (2000 psi)

Pressure Relief Valves

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

VSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES

Char-Lynn Power Steering. Parts Information. 217 Series and 227 Series OUT OUT. November, Series (Gerotor Unit) 227 Series (Geroler Unit)

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

Directional Controls

Proportional Directional Valves with Feedback. K(B)FD/TG4V-5, 12 Series Pressures to 315 bar (4500 psi)

2/2 Solenoid Cartridge Valve, Size 6

Proportional Valves. Proportional solenoid valves for pressure and flow control

SM4-10/12/15 Servovalves Flows to 57 l/min (15 USgpm) Pressures to 210 bar (3000 psi)

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

D4D SOLENOID OPERATED DIRECTIONAL CONTROL VALVES DIRECT CURRENT - SERIES 50 ALTERNATING CURRENT - SERIES 60

RPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004

Directional Control Valve Series D3W Soft Shift

DIRECTIONAL CONTROL VALVE SOLENOID OPERATED TYPE HD3-ES-*-/10 CETOP MPa HD3 - ES - (1) (C) - * - (024C) (-) / 10

Eaton Inline Self-Level Valve

Q max (see specifications table)

Solutions. Hydraulics. We Manufacture. H y d r a u l i c s. Vickers TM Proportional Directional Valves without Feedback. h y d r a u l i c s

D05 Directional Control Valves

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

DSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

Char-Lynn Steering Control Unit. Repair Information

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

Eaton Contamination Control Products FT1455-L3 Hand held launcher operating instructions

Char-Lynn Power Steering. Parts Information. 110, 230, and 450 Series. July, 1999

Eaton Contamination Control Products FT1455-L2 Hand Held Launcher Operating Instructions

Vickers. Servo Valves. SM4-40 Servovalves. Flows to 151 l/min (40 USgpm) Pressures to 350 bar (5000 psi) Released 1/94

DS5JB /110 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE. Q max 32 GPM ALTERNATING CURRENT SERIES 10

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

VED*HL-*-KD2 - HAZARDOUS LOCATION, PROPORTIONAL, DIRECT & PILOT OPERATED VALVES

DSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min

VS6M - SOLENOID OPERATED DIRECTIONAL VALVES

4/2 and 4/3-Way Proportional Directional Control Valve Direct Operated

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Directional Control Valve

ADB.3... DIRECTIONAL CONTROL

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Eaton Heavy Duty Hydrostatic Transmissions

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

FT1455-L3 Hand Launcher Operating Instructions

VEP03MSV-PDRP CONTINENTAL HYDRAULICS 3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

Pilot Operated Directional Valves

Global Gear Products. Brochure. SAE A-Aluminum (Group 2)

p max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min

Eaton Contamination Control Products FT1455-L4 Bench mount launcher operating instructions

Pilot Operated Directional Valves

FT1455-L2 Hand Launcher Operating Instructions

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

MD1JB SOLENOID OPERATED DIRECTIONAL CONTROL VALVES

Introduction. Pressure drops

Proportional Valves. Proportional solenoid valves for pressure and flow control B-1.A. An Eaton Brand

Weatherhead ET4020 & ET4040 Crimp Machines. New Crimp Machines Now Available!

Keep it Running. Proportional Valve Service and Repair Program North America. Vickers Proportional Valves Factory Service Program

Directional Controls

unrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67

DL /116 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SERIES 10 SUBPLATE MOUNTING ISO p max 320 bar Q max 125 l/min

Cartridge Valves Technical Information Directional Valves DCV 03

VEP03MSV-PDRP -3-WAY PROPORTIONAL PRESSURE REDUCING/RELIEVING VALVES

Hydrokraft Piston Motors Technical Catalog MVX

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

Q max 300 l/min. Fluid temperature range C Fluid viscosity range cst Recommended viscosity cst 25

Hydraulic Screw-in Cartridge Valves (SiCV) Proportional valves Proportional solenoid valves for pressure and flow control

DIRECTIONAL CONTROL VALVES CETOP 3/NG6

Transcription:

Vickers Solenoid Operated Directional Valves Explosion Proof ATEX, UL, CSA Sepehr Hydraulic Asia DG4V-3S, X4 & X5 DG4V4-1, X5

Table of Contents Introduction General Description... 3 Features and Benefits... 3 Characteristics... 3 Typical Side View... 3 Model Code...... 4 Spool Data... 5 Functional Symbol... 5 Operating Data... 6 Performance Data... 7 Installation Dimensions... 9 Application Data...1 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11

Introduction General Description These solenoid operated directional control valves are for directing and stopping flow at any point in a hydraulic system. This series has been specially designed and developed for equipment that has been installed in new applications in potentially explosive atmospheres. DG4V-3S, X4 option ATEX approval Hazardous locations - Ex II G; Zone 1 and Zone. Protection type - EEx me II T4; increased safety and encapsulated DG4V-3S and DG4V4, X5 option ATEX, UL, and CSA approval; complies to all 3 directives ATEX approval; hazardous locations - Ex II G; Zone 1 and Zone ; protection type EEx d IIB T*, flameproof UL and CSA approval; hazardous locations - Class 1, Group C/D; Class, Group E/F/G; Division 1 & Characteristics DG4V-3S-X4 & X5-6* Design Mounting interface ISO 441 size 3 ANSI/B93.7M size D3 CETOP RP65H, size 3 DIN 434, NG6 Basic characteristics Maximum pressure: 35 bar (575 psi) Maximum flow: Up to 4 l/min (1.5 USgpm) DG4V4-1, X5-1 Design Mounting interface ISO 441 size 5 ANSI/B93.7M size D5 CETOP RP65H, size 5 DIN 434, NG1 Basic characteristics Maximum pressure 315 bar (45 psi) Maximum flow up to 8 L/min (1USgpm) Features and Benefits New expanded product offering for hazardous environments, opening up new opportunities. Multi-fluid capability without need to change seals. Higher sustained machine productivity and higher up time because of proven fatigue life and endurance, tested over 1 million cycles. Temperature limits Minimum ambient: - C (-4 F) Maximum ambient: +7 C (158 F) Fluid temperature For mineral oil Minimum = - C (-4 F) Maximum = +7 C (158 F) The temperature limits of these valves are subject to specific operating conditions. Please refer to the Instruction for Use document supplied with each valve. Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11 3

Model Code DG4V-* * * * * M ** ** * ** (P*-A*-B*-T*) 1 3 4 5 6 7 8 9 1 1 Directional Control Valve DG4V-3S-D3/NG6 DG4V4-1-D5/NG1 Subplate Mounted, Solenoid Operated, ISO 441size Spool type,, 6, 8* * Other spools are available on request 3 Spool/Spring Arrangement A Spring offset, end to end AL As A but left hand build B Spring offset, end to center BL As B but left hand build C Spring centered 4 Manual Override Options Blank Plain overrides in solenoid end only 5 Solenoid Energisation Identity Blank ANSI B93 9 (Sol. a flow from P to A ) V Solenoid a at port A end of valve and/or solenoid b at B end of valve Note: 8 type spool must be ordered with V in model code 6 Coil Type X4 (only available on DG4V-3S) ATEX approval; Increased safety and encapsulated solenoids to IEC classification EEx me II T4 X5 ATEX, ExdIICG, approval; Zone 1 and, protection type flame proof. UL and CSA approval; Class 1, group C/D, Class group, group E/F/G/; Division 1 & 7 Coil rating X5 Coil Availability A 11V AC, 5HZ ER 1V AC, 6HZ C V AC, 5HZ ES 4V AC, 6HZ (only for DG4V4-1) H 4V DC OJ 48V DC P 11V DC X4 Coil Availability H 4V DC G 1V DC 8 Tank Port Rating 4 7 bar, for X5 valves only 7 1 bar, for X4 valves only 9 Design Number 6 DG4V-3S 61 8C spool only, DG4V-3S 1 DG4V4-1 1 Port orifice plugs Blank No orifice P** P port ** orifice size in 1/1 mm (3 =.3) A** A port ** orifice size in 1/1 mm (3 =.3) B** B port ** orifice size in 1/1 mm (3 =.3) T** T port ** orifice size in 1/1 mm (3 =.3) 4 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11

Functional Symbols Spools Available spool options (illustrated to the right) Configurations include 3-position and -position, spring centered, spring offset and no-spring detented. The valve function schematics apply to both U.S. and European valves. DG4V-3-*N(V) DG4V-3-*A(V) DG4V-3-*AL(V) DG4V-3-*C(V) DG4V-3-*B/F(V) DG4V-3-*BL/FL(V) 6 66 7 6 66 7 6 66 7 33 33 33 DG4V-3-8C(V) DG4V-3-8BL(V) DG4V-3-8B(V) 8 8 8 Solenoids identified to U.S. standards (specify A in model code) Functional symbols related to solenoid identity A and/or B according to NFPA/ANSI standards, i.e. energizing solenoid A gives flow P to A, solenoid B gives flow P to B (as applicable). Location of solenoid "A" or "B" shown relative to the hydraulic work port. Port P Port A Locating Pin Solenoid Port T For Use with Solenoid Spool Type Solenoid Port B B All except 8 A A 8 only B Solenoid "A" and "B" designations are printed on the name label adjacent to the solenoid indicator lights, illustrated above. Double solenoid valves, two position, detented Sol. B Sol. B P T Sol. A Transient condition only P Double solenoid valves, spring centered Single solenoid valves, solenoid at port A end T Sol. A Sol. B P T Single solenoid valves, solenoid at port B end P T Sol. A Solenoids identified to European standards (specify V in model code) Functional symbols related to solenoid identity A and/or B according to European convention i.e. solenoid A adjacent to A port, solenoid B adjacent to B port of valve. Location of solenoid "A" or B" shown relative the hydraulic work port. Port A Solenoid A Port P Locating Pin Solenoid B Port B Port T For Use with Solenoid Spool Type Solenoid B All spools A "A" and "B" designations are printed on the name label adjacent to the solenoid indicator lights, illustrated below. Double solenoid valves, two position, detented Single solenoid valves, solenoid at port A end Sol. A P T Sol. B Sol. A P T Double solenoid valves, spring centered Sol. A P T Sol. B Transient condition only Single solenoid valves, solenoid at port B end A P B T Sol. B Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11 5

Operating Data Data is typical, with fluid at 36 cst (168 SUS) and 5 C (1 F) Valve size DG4V-3S DG4V4-1 Pressure limits: P, A and B ports 35 bar 315 bar T port 7 bar for X5, 1 bar for X4 7 bar Flow rating See performance data See performance data Relative duty factor Continuous rating (ED = 1%) Continuous rating (ED = 1%) Type of protection IEC 144 class IP66 IEC 144 class IP66 Permissible Voltage Fluctuation DC ± 1% DC ± 1% Typical response times at 1% rated volts measured from DC AC application/removal of voltage to full spool displacement of C spool at: Flow Rate at P-A, B-T l/min l/min 4l/min 4l/min Pressure, P Port 175 bar 175 ms 175 ms 175 ms Energizing 6 ms 1 ms 6 ms 1 ms De-energizing 4 ms 1 ms 4 ms 1 ms Power consumption, solenoids at rated voltage and ºC (68ºF) X4 coils 1V DC solenoid rating - type G 3W 3W 4V DC solenoid rating - type H 3W 3W X5 coils 4V DC solenoid rating - type H 17W 17W 48V DC solenoid rating - type OJ 17W 17W 11V DC solenoid rating - type P 17W 17W 11V AC, 5Hz, solenoid rating - type A W W 1V AC, 6Hz, solenoid rating - type ER W W V AC, 5Hz, solenoid rating - type C W W 4V AC, 6Hz, solenoid rating - type ES W W 6 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11

Performance Data DG4V-3S, X4 and X5 Maximum flow rates Typical with mineral oil at 36 cst (168.6 SUS) and a specific gravity of.87. Performance based on full power solenoid coils warm and operating at 9% rated voltage. Spool/Spring Code A(L) B(L) & C, F 1 A(L) B(L) & C 6B(L) & 6C, 6F 3 8B(L) & 8C 4 DG4V-3S Pressure Drop psi 5 4 3 bar 35 3 5 15 1 3 4 1 1 5 1 3 4 l/min 4 6 8 1 USgpm Flow rate DG4V4-1, X5 Maximum flow rates Typical with mineral oil at 36 cst (168.6 SUS) and a specific gravity of.87. Performance based on full power solenoid coils warm and operating at 9% rated voltage. Spool/Spring DG4V4-1 Code AC DC A(L) 1 4 OB(L) & OC, OF 1 4 A(L) 1 4 B(L) & C 1 4 6B(L) & 6C, 6F 4 8B(L) & 8C 3 4 Pressure Drop Bar 35 8 1 14 PSI 5 4 3 1 7 1 4 3 4 8 1 16 4 8 3 USgpm 4 6 8 1 1 L/min Flow rate Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11 7

Performance Data Flow Curves DG4V-3S, X4 & X5 Spool/Spring Spool Code Positions P to A P to B A to T B to T P to T B to A A(L)C Both 5 5 - B(L)C & C De-energized - - - - 4 - Energized 4 4 - - A(L) Both 6 6 5 5 - - B(L) & C Energized 5 5 - - 6B(L) & 6C De-energized - - 3 3 - - Energized 6 6 1 1 - - 8B(L) & 8C All 7 7 5 5 3 - Pressure Drop psi 16 14 1 1 8 6 4 bar 1 1 8 6 4 6 5 4 3 7 1 1 3 4 5 6 7 8 l/min 3 69 1 15 18 1 Flow USgpm DG4V4-1, X5 Pressure drops in offset positions except where otherwise indicated. Spool code P to A P to B A to T B to T P to T 1 1 1 1 4 4 3 6 4 4 1 8 6 6 4 4 3 Pressure Drop Bar 18 16 14 1 1 8 6 PSI 8 4 16 1 8 Flow 5 4 For other viscosities, pressure drops approximate to: Viscosity cst (SUS) 14 43 54 65 76 85 (17.5) (97.8) () (51) (3) (35) (399) % of Δp 81 88 14 111 116 1 14 A change to another specific gravity will yield an approximately proportional change in pressure drop. The specific gravity of a fluid may be obtained from its producer. Fire resistant fluids usually have higher specific gravities than oil. 4 3 4 1 4 8 1 16 4 8 3 USgpm 4 6 8 1 1 L/min 8 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11

Installation Dimensions In mm DG4V-3S, X4 33.8 [9. ] Mx1.5 Mx1.5 17. 9 [4.4 ] 4.3 78.9 [.95 ] [3.1 ] 31.9 [9.13 ] 4.5 4.5 [.96 ] 47. 47. [1.85 ] DG4V-3S, X5 DG4V4-1, X5 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11 9

Application Data Fluid Cleanliness Proper fluid condition is essential for long and satisfactory life of hydraulic components and systems. Hydraulic fluid must have the correct balance of cleanliness, materials and additives for protection against wear of components, elevated viscosity and inclusion of air. Recommendations on contamination control methods and the selection of products to control fluid condition are included in Eaton s publication 913 or 561, Vickers Guide to Systemic Contamination Control. The book also includes information on the Eaton concept of ProActive Maintenance. The following recommendations are based on ISO cleanliness levels at μm, 5 μm and 15 μm. For products in this catalog the recommended levels are: to 7 bar (1 psi): 18/16/13 7+ bar (1+ psi): 17/15/1 Eaton products, as any components, will operate with apparent satisfaction in fluids with higher cleanliness codes than those described. Other manufacturers will often recommend levels above those specified. Experience has shown, however, that life of any hydraulic component is shortened in fluids with higher cleanliness codes than those listed above. These codes have been proven to provide a long trouble-free service life for the products shown, regardless of the manufacturer. Hydraulic Fluids Materials and seals used in these valves are compatible with antiwear hydraulic oils, and non-alkyl-based phosphate esters. The extreme operating viscosity range is 5 to 13 cst (7 to 7 SUS) but the recommended running range is 54 to 13 cst (45 to 7 SUS). Installation The valves in this catalog can be mounted in any attitude, but it may be necessary in certain demanding applications, to ensure that the solenoids are kept full of hydraulic fluid. Mounting Bolt Kits If not using Eaton recommended bolt kits, bolts used should be to ISO 898, 1.9 or better. Mass, approx. kg (lb) DG4V3S-*C = 3.5 kg (7.7 lb) DG4V3S-A/B =.3 kg (5.7 lb) DG4V4-1-*C = 6 kg (13. lb) DG4V4-1-*A/B = 4.5 kg (1 lb) Mounting Attitude No restrictions. Service Information It is recommended that, should any mechanical or electronic repair be necessary, valves be returned to the nearest Eaton repair center. The products will be refurbished as necessary and retested to specification before return. 1 Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11

This page left intentionally blank. Eaton Vickers D3/NG6 and D5/NG1 Solenoid Operated Directional Valves Explosion Proof V-VLDI-MC15-E January 11 11

Eaton Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 95-937-98 Fax: 95-94-77 www.eaton.com/hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 111 Morges Switzerland Tel: +41 () 1 811 46 Fax: +41 () 1 811 461 Eaton Hydraulics Group Asia Pacific Eaton Building 4th Floor, No. 3 Lane 8 Linhong Rd. Changning District Shanghai 335 China Tel: (+86 1) 5 99 Fax: (+86 1) 5 4 1 Eaton Corporation All Rights Reserved Printed in USA Document No. V-VLDI-MC15-E January 11