Singlemode Fused Coupler LGX Module (832 Series)

Similar documents
Mining and Petrochemical Tray-Rated Fiber Optic Cables

MIC Plenum Cables, 2-24 Fibers

MIC Unitized Plenum Cables, Fibers

Reliability & Qualification Report for MEMS Based Variable Optical Attenuators

High Power Directional Coupler

Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet

Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

Plug & Play AnyLAN Systems

MTP Loose Tube Trunk Assemblies. Features. Applications.

FIBER PIGTAIL/PATCHCORDS

FOL14xx Series (with Isolator) August 2017

LX2 High Density LGX 4U Patch Panel

Introduction to Fiber Cable Assemblies FiberDeep and Cable Assemblies

LX2 High Density LGX 4U Patch Panel

Fiber Cables & Hardware

UMA Fiber Optic Modular Adapter System Flexibility in a 2-Piece Adapter System

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

ezprep Gel-Free Loose Tube Gel-Free Loose Tube Cable (2.5mm)

Fiber Connector Shelf (CCS)

FAST-SC Connector. Any questions should be directed to AFL Telecommunications.

SFP Fiber Optic Transceivers

Fiber Optic, Breakout cable, tight buffered, 900 microns

FTTH simplex indoor cables with semi-tight tube

An LED collimator consists of a collimating lens and an LED

FIBER INSIDE PLANT. Rack Mount Panels Optical Modules Cable Assemblies Components

Shown: D21-42 Loveseat, D21-12 Lounge Chair, and D21-81-S Cocktail Table.

Cree Screen Master 4-mm Oval LED C4SMF-RJS/GJS/BJS C4SME-RJS

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

Instructions Parts List

Cree Screen Master 4-mm Oval LED C4SMG-RJS/GJS/BJS C4SMH-RJS

F485 Communications Converter

Application Specification. Optical Fiber. Aramid Yarns. 2mm Subunit Jacket. Strength Rods. Outer Jacket

Cree Screen Master 4-mm Oval LED C4SMG-RJS/GJS/BJS C4SMH-RJS

FC/APC Patchcord FC/APC. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss

Verizon NEBS TM Compliance: FiOS Battery NEBS Testing Verizon Technical Purchasing Requirements VZ.TPR.9508 Issue 1, June 2011

Micro Fibre Indoor Cable Multi-core (Up to 96 Fibres) Applications. Features

Verizon FTTP Tool Kits and Accessories An Evolant Solutions Product

ExpressLT Dry Dry Loose Tube Cable (2.5 mm)

Cree Screen Master 4-mm Oval LED C4SMK-RJS/GJS/BJS C4SMJ-RJS

TECHNICAL SPECIFICATIONS

9 mm Multi-Ganged Potentiometer

Cree Screen Master 4-mm Oval LED C4SMK-RJS/GJS/BJS C4SMJ-RJS

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

2 Layout Stations: More Accuracy. More Speed.

Cree Screen Master 4-mm Oval LED C4SMG-RJS/GJS/BJS Data Sheet

S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

VaultFlex Battery Enclosures. from EnerSys and Purcell Systems. Two industry leaders team up to provide new synergy, efficiency and flexibility

OSQ High Output LED Area/Flood Luminaire featuring Cree TrueWhite Technology. Product Specifications. Electrical Data*

Basic design adapted to Telcordia GR409-CORE / TIA/EIA 568B.3 / ICEA-S

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

Mini Breakout Distribution Cable Multi-core ( Fibres)

OSLON 9 PowerCluster IR

RP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output

FIBER OPTIC CABLE ASSEMBLIES ECO RANGE

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

2154D 2454D 2954D. Shortwood Hybrid Butt n Top. Forestry Grapples

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

Hard To The Core. Excavator Bucket Guide

Gas Discharge Tubes SL1002A Series

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

ATC Series QSFP CP Active Transceiver Cooler

Enhanced Management Frame (EMF)

17-223/R6G6C-D30/3C SMD B

Environmental Distribution Center (EDC-06P-NH)

LightLink Fiber Optic Splice Trays

HPS Fusion General Purpose Enclosed Transformer

Cree Screen Master 5-mm Oval LED C5SMB-RJS/GJS/BJS C5SMA-RJS Data Sheet

DNV-GL HH CE RoHS-II conform

ATC Series XFP CP Active Transceiver Cooler

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

MPO MicroCable Trunk Assembly

the Interactive Catalog

HexGen HEX HL Hexapod Six-DOF Positioning System

InfraPRO Illuminator. 850nm PoE++ High Power LED model. 940nm PoE++ High Power LED model. FEATURES SPECIFICATIONS ACCESSORIES

Section 1 COYOTE Closure Series

WLI Medium Voltage Switchgear Renewal Parts

Modular Enclosure Solutions RACK IQ - ENTERPRISE & HYPERSCALE DATA CENTER CABINETS

MIMOJunior MMJ543 WIRELESS 300Mbps OUTDOOR Access Point Built in 13dBi 5GHz DUAL POLARIZATION ANTENNA or 8dBi 2.4GHz DUAL POLARIZATION ANTENNA

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

SONNENSCHEIN LITHIUM INDUSTRIAL BATTERIES / MOTIVE POWER

Experience bright and vivid colors

Aluminum Capacitors, Power High Ripple Current, Screw Terminals

SMD 0805, NTC Thermistors AgPd Terminations

Zone 1 Linear Range - Installation Guide

OBIS Galaxy. Fiber Input, Fiber Output, Eight Channel Beam Combiner. Superior Reliability & Performance. OBIS Galaxy Features: Compact and low profile

Experience bright and vivid colors

Front panel valves SV

FR Heat Exchanger Unit Heater

Front panel valves SV

Bulletin 1494D Fixed-Depth Flange-Mounted Circuit Breakers

Indoor/Outdoor Cables Single-Armored, Plenum, Tight Buffered Distribution Indoor/Outdoor Cable

for Quadrax and ELIO 8

TOL-32EUG3W9-A. LED Lamp 2015/04/14 DL2EF3YG103-N J.F.FENG J.F.FENG Q.Y.HUANG

VariStroke II Electro hydraulic Actuator

Fortimo LED Line High Flux

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Centrix System. Features and Benefits

TIER IV. ROUGH TERRAIN VERTICAL MASTED forklifts

MINING FORESTRY MOBILE TRUCK AGRICULTURE MATERIAL HANDLING OPTIMUM

Transcription:

Features and Benefits Wideband and Dual Window Options Standard LGX Configurations High Stability & Reliability Rated for Outdoor Use Corning offers a full line of high performance coupler LGX modules. The 832 Series of products offers superior performance over repeated connections, with a full complement of industry standard features. These modules provide low insertion loss and high directivity. The 832 line fits standard LGX configurations and provides rugged construction for stable and reliable operation. Standards RoHS Design and Test Criteria Free of hazardous substances according to RoHS2011/65/EU Product is compliant with Telcordia GR-1209-CORE and GR-1221-CORE Singlemode Fused Coupler LGX Module Page 1 Revision date 2016-11-10

Specifications Parameters Operating Wavelength Single Window Operating Wavelength Dual Window Directivity Return Loss Maximum Optical Power Operating Temperature Storage Temperature Specifications 1310 ±40 nm, 1528-1563 nm, 1550 ±40 nm, or 1528-1605 nm 1310/1550 ±40 nm >55 db >50 db 300 mw -40 C to +75 C -40 C to +85 C Packaging Dimensions Standard Single Width, Double Width, and Triple Width LGX Ordering Information Singlemode Fused Coupler LGX Module - 8 3 2 1-0 0 1 2 3 4 5 1 Select Configuration 1: 1x2 2: 2x2 3: 1x3 4: 1x4 5: 1x5 6: 1x6 8: 1x8 A: 1x10 B: 1x12 C: 1x16 D: 1x32 2 3 Select Ratio 00: Even Split 01: 1/99% 02: 2/98% 05: 5/95% 10: 10/90% 15: 15/85% 50: 50/50% Select Grade 2: Premium 3: Ultra 4 5 Select Wavelength B: 1310 nm C: 1528-1563 nm D: 1550 nm E: 1310/1550 nm J: 1528-1605 nm Select Connector K: LC/APC L: LC/PC S: SC/PC T: SC/APC These part numbers are specific to Corning Optical Communications OEM Solutions Business Unit. Please contact OEM sales at +1-408-736-6900 or oemsales@corning.com and visit www.corning.com/opcomm/oem for sales support. Page 2 Revision date 2016-11-10

Single Window Wavelength: 1528-1563 nm Port Configuration IL* (Max) db PDL* (Max) db TDL** (Max) db P/N Reference 1x2 Premium 3.40 0.15 832-11NN-2CX00 0.15 Ultra 3.20 0.10 832-11NN-3CX00 1x3 Premium 5.50 0.20 832-13NN-2CX00 Ultra 5.30 0.15 832-13NN-3CX00 1x4 Premium 7.00 0.20 832-14NN-2CX00 Ultra 6.70 0.15 832-14NN-3CX00 1x5 Premium 8.10 832-15NN-2CX00 Ultra 7.90 0.20 832-15NN-3CX00 1x6 Premium 8.80 832-16NN-2CX00 Ultra 8.40 832-16NN-3CX00 1x8 Premium 10.80 832-18NN-2CX00 Ultra 1 832-18NN-3CX00 1x10 Premium 11.80 832-1ANN-2CX00 Ultra 11.50 832-1ANN-3CX00 1x12 Premium 12.80 832-1BNN-2CX00 Ultra 12.50 832-1BNN-3CX00 1x16 Premium 13.80 832-1CNN-2CX00 Ultra 13.30 832-1CNN-3CX00 1x32 Premium 17.80 0.50 832-1DNN-2CX00 0.50 Ultra 17.40 832-1DNN-3CX00 Notes: * IL and PDL are measured at 23 C without connectors. ** Temperature Dependent Loss (TDL) is measured at change in IL per degree C from -5 C to +75 C. Max IL is measured over operating wavelength range (not including PDL and TDL). Page 3 Revision date 2016-11-10

Single Window Wavelength: 1310 ±40 nm, 1550 ±40 nm, or 1528-1605 nm Port Configuration IL* (Max) db PDL* (Max) db TDL** (Max) db P/N Reference 1x2 1x3 1x4 1x5 1x6 1x8 1x10 1x12 1x16 1x32 Premium 3.50 0.15 832-11NN-2NX00 0.15 Ultra 3.30 0.10 832-11NN-3NX00 Premium 5.70 832-13NN-2NX00 Ultra 5.50 0.20 832-13NN-3NX00 Premium 7.20 0.20 832-14NN-2NX00 Ultra 6.80 0.15 832-14NN-3NX00 Premium 8.30 832-15NN-2NX00 Ultra 8.10 0.20 832-15NN-3NX00 Premium 9.30 832-16NN-2NX00 Ultra 9.00 832-16NN-3NX00 Premium 11.00 832-18NN-2NX00 Ultra 1 832-18NN-3NX00 Premium 12.00 832-1ANN-2NX00 Ultra 11.50 832-1ANN-3NX00 Premium 13.00 832-1BNN-2NX00 Ultra 12.40 832-1BNN-3NX00 Premium 14.00 832-1CNN-2NX00 Ultra 13.50 832-1CNN-3NX00 Premium 18.00 0.50 832-1DNN-2NX00 0.50 Ultra 17.50 832-1DNN-3NX00 Notes: * IL and PDL are measured at 23 C without connectors. ** Temperature Dependent Loss (TDL) is measured at change in IL per degree C from -5 C to +75 C. Max IL is measured over operating wavelength range (not including PDL and TDL). Page 4 Revision date 2016-11-10

Single Window Wavelength: 1310/1550 ±40 nm Port Configuration IL* (Max) db PDL* (Max) db TDL** (Max) db P/N Reference 1x2 Premium 3.60 0.15 832-11NN-2EX00 0.15 Ultra 3.40 0.10 832-11NN-3EX00 1x3 Premium 5.80 832-13NN-2EX00 Ultra 5.60 0.20 832-13NN-3EX00 1x4 Premium 7.40 832-14NN-2EX00 Ultra 7.20 0.20 832-14NN-3EX00 1x5 Premium 8.50 832-15NN-2EX00 Ultra 8.30 832-15NN-3EX00 1x6 Premium 9.50 832-16NN-2EX00 Ultra 9.30 832-16NN-3EX00 1x8 Premium 11.40 832-18NN-2EX00 Ultra 10.80 832-18NN-3EX00 1x10 Premium 12.30 832-1ANN-2EX00 Ultra 12.00 832-1ANN-3EX00 1x12 Premium 13.20 0.50 832-1BNN-2EX00 Ultra 12.80 832-1BNN-3EX00 1x16 Premium 14.50 0.50 832-1CNN-2EX00 Ultra 14.00 832-1CNN-3EX00 1x32 Premium 18.30 0.50 832-1DNN-2EX00 0.50 Ultra 17.80 832-1DNN-3EX00 Notes: * IL and PDL are measured at 23 C without connectors. ** Temperature Dependent Loss (TDL) is measured at change in IL per degree C from -5 C to +75 C. Max IL is measured over operating wavelength range (not including PDL and TDL). Page 5 Revision date 2016-11-10

Mechanical Drawing of Single Width LGX: 1x2, 2x2, 1x3, 1x4, 1x5 Mechanical Drawing of Double Width LGX: 1x6, 1x8, 1x10 Page 6 Revision date 2016-11-10

Mechanical Drawing of Triple Width LGX: 1x12, 1x16, 1x32 (LC Only) Corning Optical Communications LLC PO Box 489 Hickory, NC 28603-0489 USA 800-743-2675 FAX: 828-325-5060 International: +1-408-736-6900 www.corning.com/opcomm/oem Email: oemsales@corning.com Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. 2016 Corning Optical Communications. All rights reserved. Page 7 Revision date 2016-11-10