Nugget 0, V0 series Integrally ported 5/ and 5/3 Spool valves Solenoid actuated and pilot operated Ø, Ø mm or High flow from mm body width Wide range of voltages available Low profile fixed length manifolds Technical data Medium: Compressed air, filtered to 0 µm lubricated and non-lubricated Operation: Spool valve, indirectly actuated Mounting: Through holes in fixed length manifold Port sizes:, Ø mm and Ø mm (with connector blocks) Operating pressure: Maximum 0 bar See individual details overleaf Flow Characteristics: Size Function C b A l/min Cv Kv 5/ 0,55,3 5 0, 0, Ø mm 5/ 0,9 0,5 3,7 0,3 0, Ø mm 5/, 0, 5,7 3 0,35 0,3 5/3 APB, 0,3,9 9 0,3 0, Ambient temperature: -0 C to +0 C pilot models -0 C to +50 C solenoid models (consult our Technical Service for use below + C) Materials Body: zinc alloy End caps: glass filled Spool: aluminium Seals: bonded nitrile rubber Bases: glass filled co-polymer Ordering information See page Multipole systems For multipole valve islands please see data sheet 5.. Accessories Connector plugs and light emitting seals see section 7.7.00. /0 N/en 5..05.0
Nugget 0, V0 series General information 5/ solenoid actuated valves Symbol Model Manual Solenoid Operator Return Operating Pilot Weight Spares kit overide pilot pressure pressure (bar) (bar) (kg) V055A-#*A Screwdriver, bi-stable Internal Solenoid Spring and air 3... 0-0,55 V003-K00 V055A-#3*A Push only 5/3 Solenoid actuated valves V055A-#*A Screwdriver, bi-stable Internal Solenoid Solenoid... 0-0,9 V003-K00 V055A-#3*A Push only Symbol Model Manual Pilot Operator Mid Return Operating Pilot Weight Spares kit overide Supply Position pressure pressure (kg) (bar) (bar) V05A-#*A Screwdriver, bi-stable Internal Solenoid APB Solenoid -0,9... 0-0,5 V003-K0 V05A-#3*A Push button 5 3 5 3 5 3 V057A-#*A Screwdriver, bi-stable Internal Solenoid COE Solenoid -0,9... 0-0,5 V003-K0 V057A-#3*A Push button V05A-#*A Screwdriver, bi-stable Internal Solenoid COP Solenoid -0,9... 0-0,5 V003-K03 V05A-#3*A Push button # Insert pin orientation: E=up, D=down * Insert voltage code from table below. APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure. Pilot actuated valves Symbol Model Manual Solenoid Operator Return Operating Pilot Weight Spares kit overide pilot pressure pressure (kg) (bar) (bar) V0553A-X030 - Pressure - Spring and air... 0,5 + 0,5 0,5 V003-K00 x supply V05533A-X000 - Pressure - Pressure... 0... 0 0, V003-K00 V0533A-X000 - Pressure APB Pressure... 0 Minimum bar 0,9 V003-K0 V05733A-X000 - Pressure COE Pressure... 0 Minimum bar 0,9 V003-K0 V0533A-X000 - Pressure COP Pressure... 0 Minimum bar 0,9 V003-K03 V05533A-X000 - Pressure - Pressure -0,9... 0 Minimum bar 0,9 V003-K00 Priority port APB = All Ports Blocked, COE = Centre Open Exhaust, COP = Centre Open Pressure. Ordering information To order, quote model number and voltage code from tables overleaf, e.g. V055A-E3A for a Solenoid Pilot Actuated, Spring and Air Return model fitted with a V d.c. coil (pin up configuration) and screwdriver operated manual override. Valve Islands - for complete pre-assembled valve islands please contact our technical service. N/en 5..05.0 5..05.0 /0
Nugget 0, V0 series Voltage codes and spare solenoid kits Solenoid Kit Part Number Push MO Turn MO Voltage Code Power Pin Up Pin Down Pin Up Pin Down V d.c. W V-P V-P V-T V-T V d.c. 3 W V-P3 V-P3 V-T3 V-T3 V a.c. 50/0 Hz W V-P V-P V-T V-T 0 V a.c. 50/0 Hz W V-P V-P V-T V-T 0 V a.c. 50/0 Hz 9 W V-P9 V-P9 V-T9 V-T9 Electrical details for solenoid operators Voltage tolerances: -0/+5% Rating: 00% E.D. Inlet orifice: 0, mm Electrical connection: DIN 350 table C Manual override: V055**A-**A Screwdriver bi-stable V055**A-*3*A Push button, spring return Protection class: IP 5 (DIN 0050) For details of connector plugs and light emitting seals see section 7.7.00. Manifold Accessories Fixed length manifold V00-G0 ( stations) V00-G0 ( stations) V00-G0 ( stations) V00-G0 ( stations) V00-G0 (0 stations) V00-G ( stations) Optional port connector blocks Blanking plate Blanking plug V055A-Q00, Ø mm VO955A-Q00 V05-K0 V055A-Q00, Ø mm - - Basic dimensions V055A-E... models 5/ Single solenoid valve, pin orientation up V055A-D... models 5/ Single solenoid valve, pin orientation down,5,5,5,5 ø,5 5,5 3,5 7,5,5 ø,5 5 7,5 7,5 97,5 97,5,5,5,5,5,5,5 ø,7 ø,7,5,5 Manual override /0 N/en 5..05.03
Nugget 0, V0 series V055A-E... models 5/ Double solenoid valve, pin orientation up V055A-D... models 5/ Double solenoid valve, pin orientation down,5,5,5 ø,5 7,5 35 5,5 3,5 7,5,5,5 ø,5 7,5 35 5,5,5 ø,7,5,5,5,5 ø,7,5,5 Manual override V05***A-E... models 5/3 Double solenoid valve, pin orientation up,5,5,5 ø,5 7,5 5 5 V05*A-D... models 5/3 Double solenoid valve, pin orientation down,5 3,5 7,5,5,5 ø,5 7,5 5 5,5,5,5 ø,7,5,5,5 ø,7,5,5 Manual override N/en 5..05.0 /0
Nugget 0, V0 series V0553A-X030 model 5/ Single pilot valve V05533A-X000 and V05533A-X000 5/ Double pilot valves 3,5 Ø,5 3,5 Ø,5 5,5 5,5 30 0,5,5 30,5,5,5 Ø,7,5,,,5 Ø,7,5,5, V05*33A-X000 model 5/3 Double pilot valve 3,5 Ø,5 5,5 30 75,5,5 Ø,7,5,5 3,5 /0 N/en 5..05.05
Nugget 0, V0 series Fixed length manifold 9,5 A 5 5 3 5,5,5 3 5 G/ 9 33 Type No. of stations A V00 - G0 5 V00 - G0 9 V00 - G0 30 V00 - G0 V00 - G0 0 0 V00 - G 3 Note: Gaskets and valve fixing screws are supplied with these manifolds.,5 Blanking plugs V05-K0 For dual pressure supply on fixed length manifold. Ø Blanking plate V0955A-Q00 Blanking plate for blocking off unwanted stations. 3 5,5 7,5 5 M,5 Warning These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under Technical Data. Before using these products with fluids other than those specified, for non-industrial applications, life-support systems, or other applications not within published specifications, consult NORGREN. Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes. The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure. System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided. System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products. N/en 5..05.0 /0