Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Similar documents
Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Solenoid interlock AZM 170

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Operating instructions Solenoid interlock AZM About this document. Content

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Safety door-handle system STS

Operating instructions Solenoid interlock AZM About this document. Content

Solenoid interlock AZM 200 The non-contact interlock.

Technical data. Standards: IEC/EN BG-GS-ET-15

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Safety switches with solenoid and separate actuator

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

Safety Sensor CSS 180 Product Information

Safety switches with solenoid and separate actuator

Installation and Operating Instructions

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Door locking devices. 4 Schmersal Industrial Switchgear

Safety switches with separate actuator

Ex m Solenoid Operator Type 0519

Safety switches for hinges

FL series position switches

Safety rope switches with reset for emergency stop

Operating Instructions

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Installation and Operating Instructions

Guard locking systems for the protection of man and machine

Safety switches with separate actuator

Operating Instructions

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Safety switches for hinged doors

Safety rope switch without reset for simple stop

HST -LS Interlocking device (Translation of Original Manual)

Position switches FD series

Position switches FR series

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

ZB0050 / ZB0051 ZB0070 / ZB0071

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

SFS-UFS Single Foot Switches

Floor and fine adjustment switches

SG-B1 SERIES / SG-A1 SERIES

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Safety rope switch with reset for emergency stop

Switches with manual reset

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Single foot switches - PX and PA series

Operating Instructions

Hinged Safety Door Switch

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

LR-LX-LK-LW Safety Switches with separate actuator

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Datasheet - MV8H Y

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Prewired position switches FF series

NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Position Switches Series 8074/2

EStrong-series Emergency Stop

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Position switches FR series

LK Position Switches TECHNICAL DATASHEET.

Operating Instructions

Safety switches for hinged doors

NPA-CP Pendant Control Station

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Spare parts list Return line filter RFM with 2-hole attachment

Operating Instructions

Position switches FC series

MKey9-series Safety Interlock Switch with Guard Locking

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Safety switches / Position switches / Command devices

F3S-TGR-KHL1/-KHL3/-KHL3R

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Transcription:

Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. he operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 arget group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. he machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: his symbol is used for identifying useful additional information. x.000 / Juni 2013 / v.a. - 103001580- / C / 2013-0-04 / AE-Nr. 2588 Content 1 About this document 1.1 Function...1 1.2 arget group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 Appropriate use...1 1.5 General safety instructions...1 1. Warning about misuse...1 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 Special versions....2 2.3 Destination and use...2 2.4 echnical data...3 2.5 Safety classification...3 3 Mounting 3.1 General mounting instructions...3 3.2 Dimensions...3 4 Electrical connection 4.1 General information for electrical connection....3 4.2 Contact variants....4 5 Set-up and maintenance 5.1 Functional testing....5 5.2 Maintenance...5 Disassembly and disposal.1 Disassembly....5.2 Disposal...5 7 Appendix 7.1 EC Declaration of conformity... Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 Appropriate use he products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machinery or plant. he safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions he user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. he information contained in this operating instructions manual is provided without liability and is subject to technical modifications. here are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1. Warning about misuse In case of inadequate or improper use or manipulations of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. he relevant requirements of the standard 1088 must be observed. 1

Solenoid interlock AZM 11../.. 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. he manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. Manual release (for set-up, maintenance, etc.) he manual release is realised by turning the triangular key (M5 triangular key available as accessory), so that the locking bolt is pulled into the unlocking position. Please ensure that jamming by external influence on the actuator is avoided. he normal locking function is only restored after the triangular key has been returned to its original position. After being put into operation, the manual release must be secured by installing the plastic cover, which is included in delivery. Lateral manual release Manual release on the cover side or on the rear side (ordering suffix -ED/-EU) 2. Product description 2.1 Ordering code his operating instructions manual applies to the following types: AZM 11 ➀-➁➂ K➃-➄/➅-➆➇ No. Option Description ➀ CC Cage clamps SK Screw connection S Connector plug M 12 ➁ 11/03 1 NO contacts / 4 NC contacts with connector plug 11/12 2 NO contacts / 3 NC contacts with connector plug 12/03 1 NO contacts / 5 NC contacts 12/11 2 NO contacts / 3 NC contacts with connector plug 12/12 2 NO contacts / 4 NC contacts ➂ Latching force 5 N R Latching force 30 N ➃ A ➄ Lateral manual release ED Manual release on the cover side EU Manual release on the rear side ➅ Lateral emergency exit D Emergency exit on the cover side U Emergency exit on the rear side N Emergency release ➆ 024 U s 24 VAC/DC 110/230 U s 110/230 VAC ➇ without LED G with LED Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. Emergency release (mounting only on the outside of the safety guard) o activate the emergency release in case of an emergency, the orange lever must be turned to the stop in the direction marked by the arrow. In this position, the safety guard can be opened. he lever is latched and cannot be returned to its original position. o cancel the blocking condition, the central mounting screw must be loosened to such extent that the lever can be turned back into its original position. he screw then must be retightened. Emergency release (ordering suffix -N) Emergency exit (fitting and actuation only from within the hazardous area) o activate the emergency exit of the version in case of an emergency, the orange lever must be turned to the stop in direction marked by the arrow. he emergency exit function of the D and U versions is activated by pressing the red pushbutton. In this position, the safety guard can be opened. he blocking condition is cancelled by turning the lever in opposite direction or by pulling back the pushbutton. In unlocked position, the safety guard is protected against unintentional closing. Lateral emergency exit (ordering suffix -) Emergency exit on the cover side or on the rear side (ordering suffix -D/-U) 2.3 Destination and use he solenoid interlock has been designed to prevent in conjunction with the control part of a machine, movable safety guards from being opened before hazardous conditions have been eliminated. Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. he safety component and the actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling, pinning). 2

Solenoid interlock he entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards. 2.4 echnical data Standards: IEC/ 0947-5-1; ISO 13849-1; 1088; BG-GS-E-19 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing Actuator and locking bolt: stainless steel 1.4301 Contact material: Silver Protection class: IP7 Contact type: Change-over with double break Zb, galvanically separated contact bridges Switching system: A acc. IEC 0947-5-1 slow action, NC contact with positive break Positive break travel: 10 mm Positive break force: 10 N for each NC contact fitted Connection: screw terminals or cage clamps or connector plug Cable type: flexible Cable section: min. 0.25 mm², max. 1.5 mm² (including conductor ferrules) Cable entry: 4 x M1 Holding force F max : 2000 N Latching force: 30 N for ordering suffix R Actuating speed: max. 2 m / s Actuating frequency: max. 1000 operations/h Mechanical life: > 1 million operations Ambient temperature: 25 C +0 C Electrical data: Utilisation category: AC-15, DC-13 Rated operating current/voltage I e /U e : CC, SK, S 4-pole: 4 A / 230 VAC; 2.5 A / 24 VDC; S 8-pole: 2 A / 24 VDC Rated impulse withstand voltage U imp : CC, SK, S 4-pole: 4 kv; S 8-pole: 0.8 kv Rated insulation voltage U i : CC, SK, S 4-pole: 250 V; S 8-pole: 0 V hermal test current I the : CC, SK, S 4-pole: A; S 8-pole: 2 A Rated control voltage U s : 24 VAC/DC; 110/230 VAC Magnet: 100% ED Power consumption: max. 10 W Max. fuse rating: A gg D-fuse Required rated short-circuit current: 1000 A Use ype 4X (Indoor Use) and 12 connector fittings. ightening torque rating: 4.4 lb in. 2.5 Safety classification Standards: ISO 13849-1 B 10d (NC contact): 2.000.000 Service life: 20 years MF d B10d dop x hop n x 300 s/h op 0,1 x n op t cycle 3. Mounting AZM 11../.. 3.1 General mounting instructions hree mounting holes are provided for fixing the enclosure. he solenoid interlock is double insulated. he use of an earth wire is not authorised. he solenoid interlock must not be used as an end stop. Any mounting position. he mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. Unused actuator openings must be sealed with slot sealing plugs. Please observe the remarks of the standards ISO 12100, 953 and 1088. 3.2 Dimensions All measurements in mm. 22,5 8 18 8 20 32 28 2 104 130 4. Electrical connection 2 30 4.1 General information for electrical connection 72 30 25 90 he electrical connection may only be carried out by authorised personnel in a de-energised condition. At least one magnetic contact A with positive break contacts must be integrated in the safety circuit. Appropriate cable glands with a suitable degree of protection are to be used. Remove the thin walls of the mounting holes by inserting the cable entry. (Specifications can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) 3

Solenoid interlock AZM 11../.. 4.2 Contact variants Contacts are shown in the de-energised condition and with the actuator inserted. 13 21 22 14 41 42 A1 51 71 3 52 724 Q 13 21 22 14 41 42 A1 51 71 3 52 724 P AZM 11...-G with LED he contacts are shown in closed and locked condition. AZM 11SK-12/12...G AZM 11CC-12/12...G 21 22 41 42 13 14 +24 VDC 3 4 51 71 52 72 GN AZM 11SK-12/12... AZM 11CC-12/12... 13 14 21 22 41 42 51 52 3 4 71 72 + 14 21 22 41 42 51 52 4 71 72 11 21 22 12 41 42 A1 51 71 3 52 724 AZM 11SK-12/03... AZM 11CC-12/03... 13 14 21 22 41 42 51 52 3 4 71 72 11 21 22 12 41 42 A1 51 71 3 52 724 Legend 14: guard open + : +24 VDC : 0 VDC 4: unlocked System condition Solenoid control LED Contacts yellow actuator yellow magnet 21-22 41-42 13-14 3-4 51-52 71-72 AZM 11S-../.. with connector AZM 11S-12/11... 13 14 21 22 41 42 51 52 3 4 71 72 AZM 11S-11/12... 13 14 21 22 41 42 51 52 3 4 71 72 guard open 24V 0V On On Guard closed, actuator inserted (not locked) Guard closed, actuator inserted and locked 24V 0V On On On 0V 24V On On On On 1234 1234 LED on LED off AZM 11S-11/03... 11 12 21 22 41 42 51 52 3 4 71 72 1234 4

Solenoid interlock AZM 11SK-12/03...G AZM 11CC-12/03...G 21 22 41 42 11 12 Legend 12: guard closed + : +24 VDC : 0 VDC 4: unlocked +24 VDC 3 4 51 71 52 72 + 12 21 22 41 42 51 52 4 71 72 GN 5. Set-up and maintenance AZM 11../.. 5.1 Functional testing he safety function of the safety components must be tested. he following conditions must be previously checked and met: 1. Fitting of the solenoid interlock and the actuator 2. Check the integrity of the cable entry and connections 3. Check the switch enclosure for damage 5.2 Maintenance A regular visual inspection and functional test, including the following steps, is recommended: 1. Check for tight installation of the actuator and the switch 2. Remove particles of dust and soiling 3. Check cable entry and connections Damaged or defective components must be replaced.. Disassembly and disposal System condition Solenoid control LED Contacts yellow actuator yellow magnet 21-22 41-42 11-12 3-4 51-52 71-72.1 Disassembly he safety switchgear must be disassembled in a de-energised condition only..2 Disposal he safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. guard open 24V 0V On Guard closed, actuator inserted (not locked) Guard closed, actuator inserted and locked 24V 0V On On On On 0V 24V On On On On On LED on LED off 5

Solenoid interlock AZM 11../.. 7. Appendix 7.1 EC Declaration of conformity EC Declaration of conformity ranslation of the original Declaration of Conformity K.A. Schmersal GmbH & Co. KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30, 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described safety components both in its basic design and construction conform to the applicable European Directives. Name of the safety component: AZM 11 Description of the safety component: Interlocking device with electromagnetic interlock for safety functions Relevant EC-Directives: 200/42/EC-EC-Machinery Directive 2004/108/EC EMC-Directive Person authorized for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, March 7, 2013 AZM 11-D- Authorised signature Philip Schmersal Managing Director he currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K.A. Schmersal GmbH & Co. KG Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 3, D - 42232 Wuppertal Phone: +49 - (0)2 02-4 74-0 elefax +49 - (0)2 02-4 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com