QF(19) - Series Miniature Circuit Breakers

Similar documents
QF(13) - Series Miniature Circuit Breakers

QF(26) - Series Miniature Circuit Breakers - Low Rating (5-63 A)

L Frame - Series Moulded Case Circuit Breakers

Rail Mount Energy Meters. Ecolec 300 Rail Mount Energy Meters. Features. Applications. Approvals

Accessories. CBI Mini Rail (SAMR096) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR101) Mini Rail Fuchs Rail-to-Rail Adaptor Plate (SAMR100)

DD Frame - Series Circuit Breakers

Wiring Accessories. low voltage. Wiring Accessories

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

CBI Hydraulic Magnetic Circuit Breakers

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Selection Guide. Control Circuit and Load Protection

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Thermal Overload Relays

PD-Series Ground Fault Circuit Protection

G-Series. Circuit Breaker.

Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MS General Information Extended Product Type: MS

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

D509E. Manual Motor - Starters

Manual Motor Starters. Meta-MEC

Technical Information

Series KTU7 UL489 Molded Case Circuit Breakers

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

F-Series. Circuit Breaker

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

G-Series DIN-RAIL CIRCUIT BREAKER

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Series KTU7 UL489 Molded Case Circuit Breakers

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

F-Series. Circuit Breaker

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

max pole for t=15 ms

TMC 91H is now TMC 60 C Series

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Control Circuit Protection

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Data Sheet Manual Motor Starter Ex9S32 Series

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Jtec 10kA Miniature Circuit Breaker

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

up to 63 A (1 module per pole)

Thermal-Magnetic Circuit Breaker 201/-WA

FR circuit breaker - hydraulic magnetic, railway, very high current. Datasheet

UMBW-UL489 and UL1077 Listed

Thermal-magnetic Miniature Circuit Breaker 4230-T...

AR circuit breaker - Hydraulic magnetic,

Series L9 UL489 Miniature Circuit Breakers

RX 3 M.C.B A up to 63 A

Btdin RCBO 6000A up to 63A (2P)

RX 3 M.C.B A up to 63 A

Thermal-Magnetic Circuit Breaker M1-...

FR circuit breaker - hydraulic magnetic,

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

1492-CB 1492-GH 1492-GS

Data Sheet Manual Motor Starter Ex9S32 Series

Thermal overload relay TF65 and TF96

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Short form catalogue Motor protection and control Manual motor starters

Electronic overload relay EF65, EF96 and EF146

1489-M Circuit Breakers

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relays EF205 and EF370

Miniature Circuit-Breakers (MCBs)

Typical UL1077 Application

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Protection Equipment

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

Control Circuit of a UL508A Panel. Typical UL1077 Application

Electronic circuit breaker EBU10-T

Magnetic and Hydraulic-Magnetic Circuit Breaker

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

CHINT. NM7 Moulded Case Circuit Breaker

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

Thermal Overcurrent Circuit Breaker 3120-F...

Residual current devices

Bulletin 1489 Circuit Breakers. Selection Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker

Thermal Overcurrent Circuit Breaker 3120-F...

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

Jtec 489 UL489 Branch Circuit Breaker

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Product Line Overview. The Most Logically Designed Contact Assembly

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

and other modular devices for low voltage installation

Transcription:

Dual mount 1 pole Dual mount 2 pole Dual mount 3 pole Dual mount 3+N Features AC circuit breaker Hydraulic-magnetic technology % rating capability, independent of ambient temperature One, two, three pole, 1+N and 3+N VC 8036 compliant (SANS 556-1) VDE, EAC and CCC approved, CE certified UL 1077 recognised (supplementary protector) Ratings 1 to 63 A (subject to certification) Optional shunt trip (IEC / EN 60947-2) Available in various currents and time delays Precision tripping characteristics Trip indication with mid-trip position Reset immediately after overload Dual mount product in black shells Suitable to use for electrical isolation Applications AC branch circuit protection (IEC / EN 60947-2) Supplementary protection (UL 1077) Telecom / datacom equipment Lighting control UPS equipment Alternative energy equipment Mobile power generation equipment Railway signalling equipment Residential equipment Industrial equipment Auxiliary Switch, Trip Alarm & Combo: Features Auxiliary switch Auxiliary switch + trip alarm Trip alarm AC and DC voltages UL 489 listed (Auxiliary Switch: 6 A 250 V AC, 0.5 A 80 V DC) IEC 60947-5-1 approved (Auxiliary Switch: 6 A 240 V AC, 0.5 A 110 V DC; trip alarm: 6 A 240 V AC, 0.5 A 110 V DC) Factory fitted Attached to right hand side of circuit breaker Compact 6.5 mm width Optional Accessories Handle lock Surface mounting clips Busbar Escutcheon blank Safety blank Approvals VC 8036 (IEC / EN 60947-2) (UL 1077) A005438 S Page 1 of 8

Ordering Information Circuit Breaker Approvals VC 8036 (SANS 556-1) Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 1 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 5 ka Circuit Breaker Approvals IEC / EN 60947-2, VDE, CE, EAC Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 1 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 6 ka Supplementary Protector Approvals UL 1077 Tested with and without series fuse Number of Poles 1 2 3 Operating Voltages 277 V AC 480 V AC 480 V AC Minimum Current Rating 1 A Maximum Current Rating 60 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 60 A Interrupting Capacity 3 ka Circuit Breaker Approvals CCC Number of Poles 1 2 (1+N) 2 3 4 (3+N) Operating Voltages 240 V AC 415 V AC Minimum Current Rating 1 A Maximum Current Rating 63 A Specific Ratings (Verify Certification) 5, 10, 15, 16, 20, 25, 30, 35, 40, 45, 50, 63 A Interrupting Capacity 6 ka Auxiliary Switch Trip Alarm Auxiliary Switch / Trip Alarm Combo Auxiliary Module DIN and CBI Mini Rail mounted CBI Mini Rail mount only CBI Mini Rail mount only Page 2 of 8

Technical Data QF(19) Operating Temperature Range -40 C to +85 C Mounting Options Dual mounting (DIN & Mini), surface mount Time Delay Curves 1, 2, 9 Endurance 00 operations - electrical at rated current and voltage (IEC 60947-2) 6000 electrical operations (UL 1077) Dielectric Strength 1480 V (single pole) / 1830 V (multi pole), 50 Hz for one minute after testing Weight 130 g per pole, 190 g with auxiliary (unpacked) Humidity 35 to 85% relative Altitude Certification tests done at altitude 2000 metres. Will operate at higher altitudes. Shock 16 G (IEC 60068-2-27) Vibration 2 G (IEC 60068-2-6) (sinusoidal wave) Flammability I3 - Ignition does not persist at 850 C after glow wire is withdrawn with an oxygen index of 28 Toxicity F1 - Smoke index of 20 which determines the fume class Pollution Degree PD2 - Normally only non-conductive pollution occurs. Temporary conductivity caused by condensation is to be expected. Breaker QF Wire Size mm² (IEC) Wire Gauge (UL) Torque (IEC) Torque (UL) Comments 1 Pole to 4 Pole 0.75-35 mm² 18 2 AWG 2.5 Nm 20 in-lb Pozidriv #2 Combi head Page 3 of 8

Ordering Information Example Code: QF---AT-3(19)-DM-2-63A------ Group 1 2 3 4 5 6 7 8 9 10 11 Requirement QF Frame Switch / Neutral Auxiliary switch + trip alarm Triple pole 19 mm module width Dual Mount Medium delay curve 2 Current Rating 63 A Future use Shunt trip Future use Long Code QF - AT 3 (19) DM 2 63A - - - Group 1: Code Description Comments Frame Type QF 19 mm wide miniature circuit breaker dual mount Group 2: Code Description Comments Switch/Neutral - Not applicable Overload poles do not have any further coding S Switch Green handle N Neutral Green handle Group 3: Code Description Comments Auxiliary - Not applicable Use this code if no auxiliary used A Auxiliary switch (1 x Aux in 1 module) 6.5 mm module fitted on right-hand side AA Double auxiliary switch (2 x Aux in 1 module) 6.5 mm module fitted on right-hand side T Trip alarm (1 x Trip Alarm in 1 module) 6.5 mm module fitted on right-hand side AT Auxiliary switch + trip alarm combo (combined in 1 module) 6.5 mm module fitted on right-hand side Group 4: Code Description Comments No of Poles 1 Single pole 2 Double pole 2 pole or 1+N 3 Triple pole 4 Four pole 3+N only Group 5: Code Description Comments Module Width (19) 19 mm module width Group 6: Code Description Comments Mounting DM Dual mount Dual mount supplied in black body only - 57 mm escutcheon Group 7: Code Description Instantaneous Trip Point (x In) Comments Time Delays 1 Long time delay, high instantaneous trip 10 20 Orange handle 2 Medium time delay 5 10 White handle 9 Long time delay 7 12 White handle Group 8: Code / Description Comments Current Ratings available vary depending on certification Ratings 1, 2, 3, 4, 5, 6, 8, 10, 15, 16, 20, 25, 30, 32, 35, 40, 45, 50, 60, 63 A * Other ratings are available as special orders. Check availability. Group 9: Code For future use (-) Group 10: Code Description Comments Shunt Trip - Not applicable Use this code if no shunt trip is used V0 480 V AC Fly leads (approximately 60 mm long) V5 480 V AC Internally connected Other voltages are available as special orders. Check availability. Voltage on the shunt trip up to 240 V AC. Group 11 Code For future use (-) For options not listed, please contact CBI Page 4 of 8

Time Delay Curves 000 OPERATING CHARACTERISTICS 00 CURVE 1 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current Page 5 of 8

Time Delay Curves low voltage 000 OPERATING CHARACTERISTICS 00 CURVE 2 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 Minimum % Rated Current Page 6 of 8

Time Delay Curves 000 OPERATING CHARACTERISTICS 00 CURVE 9 0 Tripping Time (Seconds) 10 1 0.1 0.01 Maximum Minimum 0.001 105 130 150 200 300 400 500 0 2000 2500 3000 4000 5000 % Rated Current * The published time delay curves are generated at 30 o C ambient temperature with the Circuit Breaker mounted in the up-right position. The must hold, must trip and instantaneous trip current values are not affected by temperature, although delay time for the other operating current values may have to be adjusted using the temperature compensation curve which is available on request. Internal Impedance vs Current Rating 10,000 Q-Range impedance values 1,000 Impedance (m Ω) 10 Maximum 1 Minimum 0.1 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Amp rating Page 7 of 8

Outline Dimensions: Dual Mount Please review our Customer Terms and Conditions on www.cbi-lowvoltage.co.za All rights reserved. Unless otherwise indicated, all materials on these pages are copyrighted by CBI (Pty) Ltd. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. CBI (Pty) Ltd reserves the right to alter any details of this document without notice and while every effort is made to ensure the accuracy of the content, no warranty is given as to accuracy of this document and no responsibility will be accepted for error or misinterpretation and any resulting loss. AUSTRALIA CBI-electric: Australia 27 Wedgewood Rd, Hallam Victoria 3803 Australia Tel: +61 3 8752 9300 Fax: +61 3 9796 5407 Email: sales@cbi-electric.com.au Website: www.cbi-electric.com.au Page 8 of 8 SOUTH AFRICA CBI-electric: low voltage Tripswitch Drive Elandsfontein Gauteng South Africa Tel: +27 11 928 2000 Fax: + 27 11 392 2354 Email: cbi@cbi-electric.com internationalsales@cbi-electric.com Website: www.cbi-lowvoltage.co.za USA CBI-electric: North America 35 E. Uwchlan Ave Suite 328 Exton PA 19341 USA Tel: +1 610 524 9949 Fax: +1 610 524 9945 E-mail: info@cbibreakers.com Website: www.cbibreakers.com A member of the Group