ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

Similar documents
ACCUVALVE MODEL AVT6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVT6000 AVT6 - - DWG. NO: REVISION: REV. DATE:

ACCUSTATION SUBMITTAL MATERIALS

Accutrol, LLC Product Sheet AVC6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVT6000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Accutrol, LLC Product Sheet AVC5000. US Patents 6,991,177 & 7,543,759. Laboratories, Life Sciences, Healthcare

Acid Resistant AVC6000

Accutrol, LLC Product Sheet H-AVC5000. US Patents 6,991,177 & 7,543,759. Specially Made for Vivarium Cage Racks

Acid Resistant AVT6000

Installation & Operation Manual - Model AV3000

OPTIONS BLANK = No Options B = BACnet MS/TP D = Internal Transmitter Display (Ref Note 4)

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

INSTALLATION & OPERATION MANUAL. Fan Powered Terminals VAV TERMINALS. Redefine your comfort zone.

OE326-23I-OR VAV/Zone Controller

Advanced Outdoor Airflow Control, DCV Control and Alarm Solution for OA Applications Document Name: QG_EAC1100_A_R3A

Laboratory Exhaust Air Terminal

Powers TM Controls EA 338 Electronic Actuator

AL-Maraj Central A/C Systems Accessories Mfg Co.

MODELS TSX AND TSX-S SINGLE DUCT ROUND AIR TERMINALS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

MANUAL INSTALLATION. Venturi FX. VFX Series. v100 Issue Date: 11/22/ Price Industries Limited. All rights reserved.

Speed Sensor. Inputs: Safety Information. Outputs. Wiring Diagram. Electrical Data: NOTICE

Installation and Operation Instructions DLP Series

Lube Level Maintainer

FAN POWERED TERMINAL UNITS

CCS Zone/Bypass Damper Assembly

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

Air Quality Solutions

AD592/592-10K Non-Room Units with a Junction Box, Weatherproof (WP) or Weather Tight (EU) Enclosure

Spyder BACnet Programmable Controllers

Mount directly to 1.05 jackshafts. (new ZG-120 bracket shown) EFB24-S N4, EFX24-S N4(H) EFB24-S, EFX24-S (p. 21)

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

F6300L, 12, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

YCCS Zone/Bypass Damper Assembly

INSTALLATION INSTRUCTIONS

MC-351, 421, 431, MC-4311

GE Measurement & Control

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Safety & Installation Instructions

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

YCCS Zone/Bypass Damper Assembly

IAQ. Model AVC. SINGLE DUCT VAV Model AVC

SINGLE DUCT AIR TERMINAL UNITS

SECTION FLOW INSTRUMENTS

Installation Instructions

Technical specification

INTECH Micro 2300-RTD6

Installation Instructions

Installation. Part A, Section 3. This section covers the following unit configurations. 3400V 3500V. Voltage 4. Pump Piston (E, F, or G)

COMPACT CAGE RACK VALVES

ACCESSORIES & OPTIONS FOR VENTURI AND VENTURI FX VALVES

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Installation Instructions

Section 8. Parts A Issued 7/00. Manual V -MA -01 (formerly 7-505/6V -MA -01) E 2000 Nordson Corporation All rights reserved

2-row and All-row systems included.

F6250L, 10, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

FSAF24(-S) US, FSAF120(-S) US

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Pressure Transmitter. Informational & Installation Manual

D-70, D-140, D-210, and D-280 Series Electric Non-Spring Return Actuators

F6200L, 8, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M100F Incremental Motor Actuator R81F Interface Board

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

MODEL ELC-12/40-CVM-D BATTERY CHARGER

Laboratory Exhaust Air Terminal

Installation. Part A, Section 3. This section covers the following unit configurations: 3400V 3500V Voltage 1, 2, 3 Pump Piston (E, F, G)

AD592/592-10K Non-Room Sensors in BAPI-Box, BAPI-Box 2 or BAPI-Box 4 BA/592-x-(BB, BB2, BB4) Temperature Sensor Instructions & Operation

D24-53 Series Electric Non-Spring Return Actuators 53 lb in Models (6 N m)

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

WARNING. Important Notice

VAV TERMINAL UNIT KYODO-ALLIED TECHNOLOGY PTE LTD

Suspension System RS6525 (B)

TUNDRA 2017 Dual Black Tip Performance Exhaust Part Number: Code: EX3000 Conflicts Kit Contents Item # Qty. Reqd.

Lube Level Maintainer

F6150HD, 6, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

Instrument Enclosure Assemblies

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

BACnet Lab and Pressurized Room Controllers with Off-board Air Modules

Venturi Valve. 2 For more information visit v100. Actuator. Potentiometer. Lever Arm. Airflow Area AIRFLOW.

Direct-Coupled ControlSet Actuators (120/180/320 in-lbs.) Installation Guide 2-7/16"

Laboratory Room Controller

STR Circular VAV Terminal Units

How to Select the RE Industrial Actuator Part Number

Evolution. ECM Motor. T Control CONTROLS INC. EVO /ECM-DTC16. Differential Temperature Control. Specifications. Applications

Quick Connection Panel (QCP) Installation Guide

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Carbon Monoxide Transmitter

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Installation Instructions

PTS - Single-Blade Damper. Halton PTS. Single-Blade Damper

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

Variable Air Volume (VAV) Pressure Independent Control

The IAQ50 Air Damper/Monitor Installation and Maintenance Manual

Minimum 90 in-lb Torque. Applications. NFB, NFX Series At A Glance. NFB and NFX Series Spring Return Direct Coupled Actuator

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Smoke Dampers. Installation Instructions

Transcription:

ACCUVALVE MODEL AVC6000 SUBMITTAL MODEL CODE WARNING: NOT FOR USE WITH PERCHLORIC ACID MATERIALS VALVE HOUSING MATERIAL 2 = 304SS, 20 GAUGE 3 = 316SS, 20 GAUGE 4 = ALUMINUM, 16 GAUGE 6 = HIGH TEMP 304SS, 20 GAUGE SIZE 06 = 06" DIAMETER 08 = 08" DIAMETER 10 = 10" DIAMETER 12 = 12" DIAMETER 14 = 14" DIAMETER 18 = 12"x18" RECTANGULAR 24 = 12"x24" RECTANGULAR 36 = 12"x36" RECTANGULAR 48 = 12"x48" RECTANGULAR AVC6 - - OPTIONS BLANK = NO OPTIONS A = ACCUNET F = FLANGES (REF NOTE 4) I = INSULATION (REF NOTE 3) S = TIGHT SHUT-OFF (REF NOTE 1) W = WIRELESS BLUETOOTH ACTUATOR 03 = FAIL LAST POSITION (FLP), 2 SEC 0 = FAIL OPEN/CLOSED (FSP), 2 SEC 07 = FAIL LAST POSITION (FLP), 21 SEC Model Material Designator (2) 304SS (3) 316SS (4) Aluminum (6) High Temp 304SS Housing 304 Stainless Steel 316 Stainless Steel Al. Alloy 02-H32 304 Stainless Steel Compression Section 304 Stainless Steel 316 Stainless Steel Al. Alloy 02-H32 304 Stainless Steel Static Regain Section 304 Stainless Steel 316 Stainless Steel Al. Alloy 02-H32 304 Stainless Steel End Plate 304 Stainless Steel 316 Stainless Steel Galvanized Steel 304 Stainless Steel Blades 304 Stainless Steel 316 Stainless Steel Galvanized Steel 304 Stainless Steel Shafts 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel 316 Stainless Steel Shaft Bearings Teflon Teflon Teflon Teflon Vortex Sensors UL94-V0 Materials Exposed to the Airstream UL94-V0 UL94-VO 303 Stainless Steel Sensor Tubing Polyurethane, Ether-based Polyurethane, Ether-based Polyurethane, Ether-based Viton Rubber Compression Seals Viton Rubber Viton Rubber EPDM Rubber Viton Rubber Machine Screws 304 Stainless Steel 316 Stainless Steel 304 Stainless Steel 304 Stainless Steel Rivets 304SS 316SS 304SS 304 SS Blade Seals (optional) Viton Rubber Viton Rubber EPDM Rubber Viton Rubber MODEL CODE NOTES: 1) Blade seals are standard on all 6" valves, therefore -S option is not available for valve size -06. 2) Type factory default is set to fail open. 3) Insulation is not available on High Temperature AccuValve 4) Standard valve flanges do NOT include predrilled holes. Reference Accutrol Flange Detail Submittal Drawing for details. OPERATING RANGE Valve Model Min. Flow Measured Full Scale Range CFM L/S CMH CFM L/S CMH AVC6X06-XX 30 14 1 31 149 3 AVC6X08-XX 80 38 136 800 378 139 AVC6X10-XX 120 7 204 1300 613 2209 AVC6X12-XX 180 8 306 1790 84 3041 AVC6X14-XX 20 118 42 270 1298 4672 AVC6X18-XX 260 123 442 3200 110 437 AVC6X24-XX 30 16 9 4000 1888 6796 AVC6X36-XX 20 24 883 6400 3020 10874 AVC6X48-XX 700 330 1189 8000 377 1392 SIZE AND WEIGHT Valve Dimensions (Reference Sheet 2) Weight Valve Model "D" or "W" "L" "H" Stainless Steel Aluminum in. mm in. mm in. mm Lbs. kg Lbs. kg AVC6X06-XX.88 149 22 9 10 24 13.9 9 4.1 AVC6X08-XX 7.88 200 24 610 13 381 16 7.3 12.4 AVC6X10-XX 9.88 20 24 610 1 432 20 9.1 14 6.4 AVC6X12-XX 11.88 300 27 686 17 483 26 11.8 16 7.3 AVC6X14-XX 13.88 30 30 762 19 33 30 13.6 20 9.1 AVC6X18-XX 17.88 44 30 762 19 33 43 19. 26 11.8 AVC6X24-XX 23.88 607 30 762 19 33 49 22.2 29 13.2 AVC6X36-XX 3.88 911 30 762 19 33 97 44 9 26.8 AVC6X48-XX 47.88 1216 30 762 19 33 109 49.2 69 31.3 9-13-18 SHEET: 1 OF:

ROUND VALVE AVC6X06-XX AVC6X08-XX AVC6X10-XX AVC6X12-XX AVC6X14-XX RECTANGULAR VALVE AVC6X18-XX AVC6X24-XX Access Cover Control Module Control Module 19" 483mm 11.88" 302mm Access Cover Inlet View W 30" 762mm Housing AVC6X36-XX AVC6X48-XX 12" (30mm) L D 30" 762m m #2 #1 Control Module 6" 12mm H 11.88" 302mm Inlet Discharge W 22" 9mm 7" 178mm Mounting Strut 9-13-18 SHEET: 2 OF:

ROUND VALVE: INSTALLATION INSTRUCTIONS 1. Read all instructions prior to beginning installation. NOTE: For detailed installation instructions, refer to the AccuValve Installation & Operation Manual. 2. Verify the tag number located on the valve label matches the HVAC schedule. 3. Locate the duct section which the valve is servicing and select a suitable mounting location for the valve. WARNING: Wear eye protection, protective gloves and clothing suitable for working with sheet metal which may have sharp edges. NOTES: The AccuValve does not require straight inlet duct runs to operate properly, however it's always best to locate the valve away from transitions and bends to minimize impact on system static pressure. Be sure to select a location that will provide a minimum clearance of 14 inches (36 mm) unobstructed access to the control module, actuator and valve access cover. The AccuValve is not position sensitive. It can be installed in any plane or rotational axis without having impact on the performance. 4. Provide an opening in the selected duct section sized appropriately for the valve being installed. NOTE: A slip-fit valve will require an opening approximately 2" (0.8 mm) smaller than the valve length, whereas a flanged valve will require an opening the same length as the valve. Reference Sheet 1 for valve dimensions.. Install duct hangers within 12 inches (30 mm) from each end of the valve. Reference Sheet 1 for valve weights. WARNING: Use duct hangers and hardware designed to support the total load of valve and associated duct sections. Failure to do so may result in serious personal injury or death. 6. Install the valve into the duct in accordance with the Airflow Direction Label located on the valve. Position the valve for easy access to the transmitter side then secure to duct per the appropriate Figure below. NOTE: Screws, nuts, fasteners, duct sealant, hangers, and gaskets are not provided by Accutrol LLC. Standard Slip-fit Valve Secured Using Tek Screws Secure valve to duct at both ends using tek screws and duct sealant. Standard Slip-fit Valve Secured Using Draw Bands (Draw Bands are Sold Separately) Reference Accutrol Draw Band Clamp Submittal Drawing for Details After sealing joints with appropriate type of tape, secure both ends using draw band clamps. Flanged Valve Option F Secured Using Companion Flanges (Companion Flanges are Sold Separately) Reference Accutrol Flange Option Submittal Drawing for Details Install companion flanges to duct ends and secure to duct. Apply duct sealant and/or gasket to flange face. Install valve and secure flanges using tek-screws. 14" (36mm) 14" (36mm) Figure 1 Figure 2 14" (36mm) Figure 3 9-13-18 SHEET: 3 OF:

RECTANGULAR VALVE: INSTALLATION INSTRUCTIONS 1. Read all instructions completely before installing the valve. WARNING: Wear eye protection, protective gloves and clothing suitable for working with sheet metal which may have sharp edges. 2. Verify the tag number located on the valve label matches the HVAC schedule. 3. Select optimum mounting location for the valve. NOTE: The AccuValve does not require straight inlet duct runs to operate properly, however it s always best to locate any duct device away from transitions and bends to minimize impact on system static pressure. 4. Allow a minimum clearance of 14 inches (36 mm) unobstructed access to the transmitter, actuator and valve access cover. NOTE: Rectangular valves are normally installed with the access side facing downwards for easy access. However, the AccuValve is not position sensitive. It can be installed in any plane or rotational axis without having impact on the performance.. To support the weight of the valve, install duct hangers within 12 inches (30 mm) of valve connections. The 12"x36" and 12"x48" valves include an integral mounting strut which shall be used to support the valve in addition to the duct hangers. Reference Sheet 1 for valve weights. WARNING: Use duct hangers and hardware designed to support the total load of the valve and associated duct sections. Failure to do so may result in serious personal injury or death. 6. After the duct section is properly supported to carry the weight of the valve, install valve into the duct in accordance with the Airflow Direction Label located on the valve. Position valve so the transmitter, actuator and access cover are easily accessible. For 12x36" and 12x48" valves, attach the integral mounting bracket to threaded rod or duct hangers capable of supporting valve weight. 7. Reference the appropriate diagram to the right for installation details. NOTE: Screws, nuts, fasteners, duct sealant, hangers, companion flanges and gaskets are not provided by Accutrol LLC. Figure 1 Standard Slip-fit Valve Using Tek Screws Figure 2 Flanged Valve Option F Using Companion Flanges Figure 3 12x36" and 12x48" Valves RECTANGULAR VALVE: INSTALLATION DIAGRAMS Support AccuValve Support WARNING: Dual valves are provided with an integral mounting strut to help support the weight of the valve. In addition to supporting the duct within 12" of the valve, each end of the integral mounting strut shall be secured to the building structure using properly rated hardware and methods in accordance with local building codes. Failure to do so may result in serious personal injury or death. Secure both ends using tek screws and duct sealant 14" (36mm) Mounting Struts Apply Sealant and/or Gasket, then Secure both ends using tek-screws 14" (36mm) Support Apply Sealant Support Support Here 9-13-18 SHEET: 4 OF

CONTROL MODULE NOTE: Do not use controller enclosure as junction box for other equipment Cover Tab Slot 16 Gauge Aluminum Enclosure and Cover Cable Tie Clip Provided for Strain Relief WIRING DIAGRAM NOTE: Connections will vary based on application. For detailed wiring instructions, use this drawing in conjunction with the job-specific wiring diagrams. Reference AccNet Field Manual for Wiring Details Captive Thumb Screw for Removing/Securing Cover Alternate Cable Entry Wiring Instructions 1. Remove cover. 2. Route cables through the strain-relief fitting into the enclosure. ELECTRICAL SPECIFICATIONS POWER: 24vAC /-20%, 0/60Hz. (Class 2 Power Source) or 24vDC /-10%. Cable Entry with Ratcheting Strain Relief for Field IO Connections Note: If a conduit connection is required, the strain relief fitting and bushing can be removed and replaced with a.87" (22mm) conduit fitting. (Provided by Others) 3. Remove terminal block plug(s) and connect wires to the appropriate terminals. 4. Secure terminal screws and reinstall plug(s).. Insert the ratcheting strain relief over cable(s) and push down until snug. 6. Reinstall cover and secure thumb screw. Valve sizes 06" through 24" MAX POWER WITH MAX POWER WITH NO MONITOR FHM1 CONNECTED Type 24 vac 24 vdc 24 vac 24 vdc 3 27 VA 14 W 31 VA 16 W 28 VA 16 W 32 VA 18 W 7 14 VA 6 W 18 VA 8 W Optional Monitor or Remote Com Port Direct Connect Valve sizes 36" and 48" MAX POWER WITH MAX POWER WITH NO MONITOR FHM1 CONNECTED Type 24 vac 24 vdc 24 vac 24 vdc 3 49 VA 2 W 3 VA 27 W 1 VA 29 W VA 31 W 7 19 VA 9 W 23 VA 11 W Power Source OR 24 vdc 24 vac Accutrol VSS Analog Output Accutrol HSS DDC Controller Analog Inputs Digital Inputs CAUTION: Maintain polarity if power source is used to power multiple devices otherwise equipment may be damaged. SW 1 INPUTS: Analog Inputs: AI-1, AI-2 and AI-3 (Software Selectable) Voltage: 0-10v Range, Input Impedance = 100K ohms Current: 0-20mA Range, Input Impedance = 00 ohms Resistance: 0-20K Range, 00uA Internal Current Source Digital Inputs: 2 dry-contact inputs OUTPUTS: Analog Outputs AO-1, AO-2 (software selectable): 0-20mA, 4-20mA, 0-10v, 2-10v, 0-v or 1-v V-out capable of driving 1 K-ohm load @ 10v, I-out capable of driving 1K-ohm load Alarm Output: DPDT Relay, NC/NO Contacts, 1A @ 30vDC or 0.3A @ 12 vac RS-48: EIA 48 BACnet MS/TP 2-wire, Receiver Impedance: ¼ unit load Note: Network bias and field termination are NOT provided by the AVC Control Module MONITOR PORT, RJ-4: Connect to Accutrol monitor or remote com port. Connect using factory supplied cable only CONFIGURATION PORT: USB Type C, Wireless Bluetooth (Optional) IO TERMINAL PLUGS: 2 & 3 position, vertical pluggable, screw access on top, wire size range 12-30 AWG SW 2 DI To Next Device DI - - From Previous Device - BACnet MS/TP Factory Supplied Cable EIA 48 BACnet MS/TP Bus Shield Accutrol Monitor or Remote Com Port 9-13-18 SHEET: OF: