VQE: 2-way flanged valve, PN 16

Similar documents
VQD: 2-way flanged valve, PN 6

VUP: Pressure-relieved 2-way flanged valve, PN 25 (el.)

BUG: 3-way flanged valve, PN 25/16 (el.)

V6R: 2-way valve with female thread, PN 16 (el.)

V6R: 2-way valve with female thread, PN 16 (pn.)

B6R: 3-way valve with female thread, PN 16 (pn.)

BQE: 3-way flanged valve, PN 16

BUE: 3-way flanged valve, PN 16/10 (el.)

BUD: 3-way flanged valve, PN 6 (pn.)

VUD: 2-way flanged valve, PN 6 (pn.)

76.126/1. BUS: Flanged three-way valve, PN 40. Sauter Components

BUN: 3-way valve with male thread, PN 16

Connection. k VS -Value m 3 /h

Connection. k VS -Value m 3 /h

76.116/1. BUE: Flanged three-way valves, PN 16/10. Sauter Components

Connection. k VS value m 3 /h

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

Product description. EM converterled

Low-watt Type Solenoid Valve

FlowControl BUE/BQE 2 & 3 - way control valves

Symbol indicating an action that must not be done. Symbol indicating an action that should be done. Symbol indicating related or useful information

M Point & 3-Point Electric Damper-Actuator

AKM 105, 115: Rotary actuator for ball valve

Hydronic Accessories H YDRONIC C OMPONENTS & S YSTEMS. Taco Catalog # Supersedes: Dated: 02/1/01

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

USER INSTRUCTIONS. Valtek VL-ES Actuators. Installation Operation Maintenance. Experience In Motion FCD VLENIM /06

Product manual. Tdriver LCA PRE / LC EXC

Pneumatic Corner Drill

Diaphragm Seals NEW! For Pressure Products For Pressure Products

Full Port Ball Valves

Z SLIDERS. Introducing a low profile actuator installing a circulating type linear guide!

POWERING THE WAY Rental Power Planner

AVM 215S-R: Valve actuator with SAUTER Universal Technology (SUT)

PCU CORE FIRE PROTECTION ELECTRICAL DETAIL

RX 50 Technical Data.

GEH-230W StPersetles GEH-230V INSTRUCTIONS. f:. l I ' INSTRUMENT TRANSFORMERS DRY AND COMPOUND-FILLED TYPES. GENERAL. E,LECTRIC

DATA SHEET LC-D CONTACTORS

BUN: 3-way valve with male thread, PN 16

AVP : Pneumatic valve actuators

Three Way Ball Valves

Associated controllers Controller selection

Axial fans Product-specific information

2-Way and 3-Way Globe Valve Assemblies. Two-Way Pneumatic Spring Return Models

FlowControl VUN/BUN 2 & 3 - way control valves

X-M 6, X-W6, X-F 7, X-M 8, M 10, W 10 Threaded Studs for Concrete

Technical Design-in Guide. Tengine STARK SLE GEN2

COUNCIL OF THE EUROPEAN UNION. Brussels, 13 May /13 ADD 7 ENER 177 ENV 386 DELACT 19 COVER NOTE

Three-phase Induction Motors. Empowering the Future

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

AVM321, 322: Actuator SAUTER vialoq AVM 1000

Nickel Cadmium Battery

SAF MODUL t AIR SUSPENSION SYSTEM WITH DISC AND DRUM BRAKE 17.5, 19.5 AND 22.5

Deburring and fettling systems for robots and CNC machine tools

VEGETABLE CUTTING MACHINE OPERATION MANUAL TT-F60 / TT-F65 TT-F60 TT-F65

AVP : Pneumatic valve actuators

Corps of Engineers Low-Volume Road Design

New! designline - quality and performance with appeal

AXS 215S: Continuous actuator for unit valves, with stroke indicator

Characteristics TeSys contactors 0 Model d

A44 W0...W2: Motorised actuator

R 70 Technical Data. Diesel and LP Gas Trucks R compact R compact R compact

DIRECTIONAL GROUND RELAY. Type CFPC16A. G E N E R A L ELECTRIC

Hairdryer Switches 01

Access Rectangular In-Line Fans (ARH)

Combi valves PN 16 with flanged connections

Safety Considerations for Truck Climbing Lanes on Rural Highways

MH32F, MH42F: Control valve with flange connection, PN 6

ENGINE CONTROL SYSTEM SECTIONEC CONTENTS

3-port valves vxf42..

2-port seat valves PN16 with flanged connection

EXPLOSION-PROOF MOTOR DRIVEN CABLE REELS MCR

HEATING & CHILLED SYSTEM PRESSURISATION UNITS AQUAPACK ET SERIES

Excess pressure regulator Excess pressure regulator, straight through DN

Technical Databook. Car πn 4x4 πn Van

SPOA10NB, SPOA10, SPO10

3-port seat valves PN16 with flanged connection

AVM 105, 115: Valve actuator

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: material properties

Lexan Hardcoated Polycarbonate VStream Windscreen Z2476, Z2477 and Z2478 for F800GT

A Study on the Measuring System of the Variation of the Aiming Baseline in the Aiming Sights

INVESTIGATIONS ON POSSIBLE CHARACTERISTICS OF FW SUPERHIGH SEATING CAPACITY AIRPLANE

CHAPTER 8 BRAKES/FINAL DRIVE

Maintenance-free metal-seated globe valves. Grey cast iron PN 16 DN Nodular cast iron PN 16 DN Nodular cast iron PN 25 DN

Emission Measurement and Testing of Multi Cylinder C.I. Engine Operated by Intercooled Turbocharger

Effect of Aggregate Gradation on Measured Asphalt Content

ENGINE CONTROL SYSTEM SECTIONEC CONTENTS

Si Engineering GREAT Solutions. Process and steam safety valves to PED and DIN/EN standards

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

CABINETS CABLE ENTRY SEALS FOR CABINETS AND ENCLOSURES. We Seal Your World

Globe Valve, Metal. Sectional drawing

Merchant Shipping (MARPOL Annex VI - Prevention of Air Pollution) Order 2014

ARI-Strainer. ARI-Strainer - Screen and supporting basket made of stainless steel. ARI-Strainer - Y-pattern with flanges

Overview of types. Technical data

2-Port Seat Valves with Flange, PN 25

Maintenance-free metallic seat shut-off globe valves

3-Port Seat Valves with Flange, PN 6

3-Port Seat Valves with Flange, PN 10

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Transcription:

Ambient onditions 1) Operating temperature 2) -10...150 C Produt data sheet 56.117 VQE: 2-way flanged valve, PN 16 How energy effiieny is improved Effiient use in ontinuous ontrol systems Features Continuous ontrol of old/hot water and low-pressure steam up to 115 C in losed iruits Water quality as per VDI 2035 In ombination with valve atuators AVM 322(S), AVM 234S and AVF 234S as ontrol unit Not suitable for drinking water or potentially explosive atmospheres Valve with flange onnetion as per EN 1092-2, seal form B Regulating valve, free of silione grease, painted blak Charateristi an be set with SUT (SAUTER Universal Tehnology) valve atuators to linear, equal-perentage or quadrati The valve is losed when the spindle is moved out Closing against the pressure Valve body and seat made of grey ast iron Stainless-steel spindle Plugs made of stainless steel with metal-to-metal seal Stuffing box made of stainless steel with wiper ring and double O-ring seal made of EPDM VQE Tehnial data Parameters Nominal pressure PN 16 Connetion Valve harateristi Control ratio of valve > 30:1 Stuffing box Flange as per EN 1092-2, form B Equal-perentage 2 EPDM O-rings Leakage rate Class III as per DIN EN 60534-4 (0.001 x k vs ) Valve stroke 20 mm (DN 65...80) 40 mm (DN 100...150) Operating pressure Up to 120 C 16 bar At 150 C 14.4 bar Between 120 C and 150 C, a linear interpolation an be performed Standards and diretives Pressure and temperature data EN 764, EN 1333 Flow parameters EN 60534 (page 3) Pressure Equipment Diretive 97/23/EC (fluid group II) With CE label Overview of types Type Nominal diameter k vs value Weight VQE065F300 DN 65 63 m³/h 23.8 kg VQE080F300 DN 80 100 m³/h 30.2 kg VQE100F300 DN 100 160 m³/h 41.3 kg VQE125F300 DN 125 220 m³/h 62 kg VQE150F300 DN 150 320 m³/h 89 kg Aessories Type Desription 0372336180 Adaptor (required when temperature of the medium is 130...150 C) from DN 65 0378284100 Stuffing box heater 230V~, 15 W for medium below 0 C 1) Air humidity must not exeed 75% 2) At temperatures below 0 C, use a stuffing box heater. Use adaptor (aessory) at temperatures above 130 C Right of amendment reserved 2015 Fr. Sauter AG 3.1 1/8

Type Desription 0378284102 Stuffing box heater 24V~, 15 W for medium below 0 C 0378369101 Complete replaement stuffing box from DN 65 Combination of VQE with eletri atuators / Warranty: The tehnial data and pressure differenes indiated here are appliable only in ombination with SAUTER valve atuators. The warranty does not apply if used with valve atuators from other manufaturers. / Definition of p s : Maximum admissible pressure drop in the event of a malfuntion (pipe break after the valve) at whih the atuator reliably loses the valve by means of a return spring. / Definition of p max : Maximum admissible pressure drop in ontrol mode at whih the atuator reliably opens and loses the valve. Combination of VQE with eletri atuators, atuating power 1000 N Atuator AVM322F120 AVM322F122 Atuating power 1000 N 1000 N AVM322SF132 Control signal 2-/3-point 2-/3-pt., 0...10 V, 4...20 ma Running time 120/240 s 120/80 s Closes against the pressure p max p [bar] p max VQE065F300 2.5 2.5 VQE080F300 1.5 1.5 Cannot be used to lose with the pressure A Maximum media temperature: 100 C Combination of VQE with eletri atuators, atuating power 2500 N, 2000 N Atuator AVM234SF132 AVF234SF132 AVF234SF232 Atuating power 2500 N 2000 N Control signal 2-/3-pt., 0...10 V, 4...20 ma 2-/3-pt., 0...10 V, 4...20 ma Running time DN 65, DN 80 Running time DN 100...150 Closes against the pressure 40/80/120 s 40/80/120 s 80/160/240 s 80/160/240 s p [bar] p max p max p s VQE065F300 3.0 3.0 5.1 VQE080F300 3.0 3.0 3.4 VQE100F300 2.0 2.0 2.2 VQE125F300 1.5 1.4 1.4 VQE150F300 1.0 1.0 1.1 Cannot be used to lose with the pressure A A Spring return: AVF234SF132 normally losed (NC); AVF234SF232 normally open (NO) At temperatures above 130 C, aessories are required Desription of operation The valve an be moved to any intermediate position with an eletri atuator. When the spindle is moved out, the ontrol passage of the valve is losed. The nominal diameters DN 65 to DN 150 may only be used when employing the against the pressure losing proedure. The flow diretion marked on the valve must be observed. The flow parameters orrespond to EN 60534. 2/8 3.1 Right of amendment reserved 2015 Fr. Sauter AG

Closing against the pressure These ontrol valves are haraterised by their reliability and preision and make an important ontribution towards environmentally friendly regulation. They meet diffiult hallenges suh as the quiklosing funtion, overoming differential pressures and ontrolling medium temperatures, all with a low noise level. The valve spindle is automatially and firmly onneted to the atuator spindle. The stainless steel plug ontrols the equal-perentage flow rate in the ontrol passage. The tightness of the valve is ensured by the seat inorporated in the body. The stuffing box is maintenane-free. This onsists of a stainless steel body, two O-rings, a wiper ring and a grease reserve. This is free of silione grease, and silione oil may not be used for the spindle. Intended use This produt is only suitable for the purpose intended by the manufaturer, as desribed in the Desription of operation setion. All related produt douments must also be adhered to. Changing or onverting the produt is not admissible. Engineering and fitting notes The valves are ombined with the valve atuators without a spring return or with valve atuators with a spring return. The atuator is mounted diretly on the valve and fastened with srews. The atuator is onneted with the valve spindle automatially. When the system is ommissioned, the atuator moves out and the onnetor loses automatially when it reahes the lower valve seat. The stroke of the valve is also deteted by the atuator, and no further adjustments are required. Therefore the fore on the seat is always the same and the smallest amount of leakage is ensured. With the SUT atuators, the harateristi an be set to linear or quadrati as required. Additional tehnial data Tehnial information SAUTER slide rule for valve sizing P100013496 Tehnial manual on ontrol units 7 000477 001 Parameters, fitting notes, ontrol, general information Fitting instrutions Appliable EN, DIN, AD, TRD and UVV regulations P100013463 AVM 234S assembly MV 505919 AVF 234S assembly MV 505920 AVM 322(S) assembly P100011900 Delaration on materials and the environment MD 56.117 Fitting position The ontrol unit an be fitted in any position, but the hanging position is not reommended. Condensate, drops of water, et. must be prevented from entering the atuator. When installed horizontally, and with regard to the valve spindle, the admissible atuator or support weight, without strutural support, is max. 25 kg. When the atuator is mounted on the valve, make sure the plug is not twisted on the seat (this an damage the sealing surfae). When insulating the valve, it may only be insulated up to the onneting lip of the atuator. To inrease the funtional reliability of the valves, the system should onform to DIN/EN 14336 (heating systems in buildings). DIN/EN 14336 states, amongst other things, that the system has to be flushed through before being put into servie. Using with steam The valves an be used for low-pressure steam up to 115 C with the same p max values. When using the valve, make sure that it does not operate mainly on the lower third of its stroke range. This leads to an extremely high flow speed, whih greatly redues the servieable life of the valve. Right of amendment reserved 2015 Fr. Sauter AG 3.1 3/8

Using with water So that impurities are retained in the water (welding beads, rust partiles, et.) and the spindle seal is not damaged, we reommend installing olleting filters, for example one for eah floor or pipe run. Water requirements aording to VDI 2035. When using an additive in the water, the ompatibility of the materials must be heked with the manufaturer of the medium. The materials table shown below may be used. When glyol is used, we reommend using a onentration of between 20% and 55%. Other information regarding hydraulis and noise in systems The valves an be used in a low-noise environment. To prevent noise, the pressure differenes p max listed below should not be exeeded. The pressure differene p v is the maximum pressure that may at on the valve regardless of the stroke position, in order that the risk of avitation and erosion is limited. These values are irrespetive of the atuator fore. Cavitation aelerates wear and auses noises. To prevent avitation, the pressure differential on the valve should not exeed the value p krit : p krit = (p1 p v ) 0.5 p1 = upstream pressure before the valve (bar) p v = steam pressure at operating temperature (bar) The alulation works with absolute pressure. For the spring return, the stated p s values are also the permissible differential pressure up to whih the atuator an guarantee that the valve is losed in the event of an inident. Beause this is a quik-losing funtion with a fast stroke movement (using a spring), this value an exeed p max. 4/8 3.1 Right of amendment reserved 2015 Fr. Sauter AG

Flow-rate hart 1000 1 10 P [kpa] v100 100 280 V 100 3 [m /h] V 100 [l/s] 100 DN 150 kvs 320 DN 125 kvs 220 DN 100 kvs 160 DN 80 kvs 100 DN 65 kvs 63 28 10 2,8 1 0.01 0.1 P [bar] 1 10 v100 Type p v Against the pressure VQE065F300 1.0 - VQE080F300 0.8 - VQE100F300 0.6 - VQE125F300 0.6 - VQE150F300 0.6 - Additional version information With the pressure Valve body made of grey ast iron as per EN 1561, ode EN-GJL-250, material number EN-JL 1040 with smooth drilled flanges as per EN 1092-2, seal form B. Valve body proteted by matt paint RAL 9005 jet blak. Fitted in the piping with welding flange as per EN 1092-1. Valve fitting length as per EN 558-1, basi series 1. Flat seal on valve body made of asbestos-free material. Right of amendment reserved 2015 Fr. Sauter AG 3.1 5/8

Material numbers aording to DIN DIN materials DIN designation Valve body EN-JL 1040 EN-GJL-250 (GG25) Valve seat EN-JL 1040 EN-GJL-250 Spindle 1.4021 X20Cr13 Plug 1.4021 X20Cr13 Stuffing box 1.4104 X12CrMoS-17 Additional details on the definitions of pressure differene p v : Maximum admissible pressure differene over the valve at every stroke position, limited by noise level and erosion. With this parameter, the valve is haraterised as a flow element with speifi hydrauli behaviour. Monitoring the avitation and erosion along with the assoiated noise inreases the servie life and the operational apaity. p max : Maximum admissible pressure differene over the valve at whih the atuator an reliably open and lose the valve. The following are onsidered: Stati pressure and flow effets. This value ensures trouble-free stroke movement and losing of the valve. The value p v of the valve is never exeeded. p s : Maximum admissible pressure differene over the valve in the event of a malfuntion (e.g. power failure, exessive temperature or pressure, pipe break) at whih the atuator an lose the valve tightly and, if neessary, maintain the full operating pressure against atmospheri pressure. Beause this is a safety funtion with a rapid stroke movement, p s an be greater than p max or p v. The disruptive flow effets that arise here are quikly passed through and are of minor importane in this mode of operation. For 3-way valves, the values only apply to the ontrol passage. p stat : Line pressure behind the valve. This essentially orresponds to the idle pressure when the pump is swithed off, aused for example by the fluid level in the system, inreased pressure due to pressure tanks, steam pressure, et. For valves that lose with pressure, the stati pressure plus the pump pressure are used. Disposal When disposing of the produt, observe the urrently appliable loal laws. More information on materials an be found in the Delaration on materials and the environment for this produt. Charateristi for atuators with positioner On atuator AVM 322S, AVM 234S or AVF 234S Equal-perentage/linear/quadrati 6/8 3.1 Right of amendment reserved 2015 Fr. Sauter AG

Dimension drawings DN 65 150 E H d b A Øk DN L VQE 065 080 100 125 150 DN 65 80 100 125 150 A 149.5 161.5 181.5 233.5 246.5 102 112 127 160 181 L 290 310 350 400 480 H 20 20 40 40 40 k 145 160 180 210 240 d 4x19 8x19 8x19 8x19 8x23 b 20 22 24 27 27 E 93 93 113 113 113 Combinations AVM 234 AVF 234 57 60 230 57 73 230 > 150 289 > 150 289 Right of amendment reserved 2015 Fr. Sauter AG 3.1 7/8

AVM 322(S) 44 44 160 >150 241 Aessories 0378284 100 0378284 102 36 71 1000 70 14,5 40,9 Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-ontrols.om 8/8 3.1 Right of amendment reserved 2015 Fr. Sauter AG