V6R: 2-way valve with female thread, PN 16 (el.)

Similar documents
V6R: 2-way valve with female thread, PN 16 (pn.)

B6R: 3-way valve with female thread, PN 16 (pn.)

VQE: 2-way flanged valve, PN 16

VQD: 2-way flanged valve, PN 6

VUP: Pressure-relieved 2-way flanged valve, PN 25 (el.)

BUG: 3-way flanged valve, PN 25/16 (el.)

BUN: 3-way valve with male thread, PN 16

BUE: 3-way flanged valve, PN 16/10 (el.)

BQE: 3-way flanged valve, PN 16

76.126/1. BUS: Flanged three-way valve, PN 40. Sauter Components

BUD: 3-way flanged valve, PN 6 (pn.)

VUD: 2-way flanged valve, PN 6 (pn.)

Connection. k VS -Value m 3 /h

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

Connection. k VS -Value m 3 /h

VDL : 2-way regulating valve for dynamic hydronic balancing, PN 25, Valveco compact

Connection. k VS value m 3 /h

Symbol indicating an action that must not be done. Symbol indicating an action that should be done. Symbol indicating related or useful information

Product description. EM converterled

BUN: 3-way valve with male thread, PN 16

AVP : Pneumatic valve actuators

AKM 105, 115: Rotary actuator for ball valve

Low-watt Type Solenoid Valve

Axial fans Product-specific information

AVP : Pneumatic valve actuators

A44 W0...W2: Motorised actuator

AVM 215S-R: Valve actuator with SAUTER Universal Technology (SUT)

USER INSTRUCTIONS. Valtek VL-ES Actuators. Installation Operation Maintenance. Experience In Motion FCD VLENIM /06

76.116/1. BUE: Flanged three-way valves, PN 16/10. Sauter Components

Pneumatic Corner Drill

M Point & 3-Point Electric Damper-Actuator

AVM321, 322: Actuator SAUTER vialoq AVM 1000

Hairdryer Switches 01

Product manual. Tdriver LCA PRE / LC EXC

RX 50 Technical Data.

AVM 105, 115: Valve actuator

POWERING THE WAY Rental Power Planner

AKM 105S, 115S: Rotary actuator with SAUTER Universal Technology (SUT) for ball valve

Full Port Ball Valves

Three Way Ball Valves

Hydronic Accessories H YDRONIC C OMPONENTS & S YSTEMS. Taco Catalog # Supersedes: Dated: 02/1/01

Technical Design-in Guide. Tengine STARK SLE GEN2

DATA SHEET LC-D CONTACTORS

COUNCIL OF THE EUROPEAN UNION. Brussels, 13 May /13 ADD 7 ENER 177 ENV 386 DELACT 19 COVER NOTE

VEGETABLE CUTTING MACHINE OPERATION MANUAL TT-F60 / TT-F65 TT-F60 TT-F65

Z SLIDERS. Introducing a low profile actuator installing a circulating type linear guide!

Technical Databook. Car πn 4x4 πn Van

GEH-230W StPersetles GEH-230V INSTRUCTIONS. f:. l I ' INSTRUMENT TRANSFORMERS DRY AND COMPOUND-FILLED TYPES. GENERAL. E,LECTRIC

INVESTIGATIONS ON POSSIBLE CHARACTERISTICS OF FW SUPERHIGH SEATING CAPACITY AIRPLANE

Diaphragm Seals NEW! For Pressure Products For Pressure Products

FlowControl VUN/BUN 2 & 3 - way control valves

Nickel Cadmium Battery

X-M 6, X-W6, X-F 7, X-M 8, M 10, W 10 Threaded Studs for Concrete

AXS 215S: Continuous actuator for unit valves, with stroke indicator

Characteristics TeSys contactors 0 Model d

PCU CORE FIRE PROTECTION ELECTRICAL DETAIL

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

SCHEDULE DISTRIBUTION USE OF SYSTEM CHARGES

SAF MODUL t AIR SUSPENSION SYSTEM WITH DISC AND DRUM BRAKE 17.5, 19.5 AND 22.5

Modulating control valve PN16 with magnetic actuator

R 70 Technical Data. Diesel and LP Gas Trucks R compact R compact R compact

www. ElectricalPartManuals. com Westinghouse

EGQ 212: Duct transducer, CO 2 and temperature

Corps of Engineers Low-Volume Road Design

ADM 322: Rotary actuator

MH32F, MH42F: Control valve with flange connection, PN 6

Access Rectangular In-Line Fans (ARH)

FlowControl BUE/BQE 2 & 3 - way control valves

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: material properties

2.61 Internal Combustion Engines Spring 2008

Ball valve and actuator. Maximum control precision for a wide variety of applications.

CABINETS CABLE ENTRY SEALS FOR CABINETS AND ENCLOSURES. We Seal Your World

Deburring and fettling systems for robots and CNC machine tools

A Study on the Measuring System of the Variation of the Aiming Baseline in the Aiming Sights

Simulation study on performance and emissions of a Small Direct Injection Diesel Engine fueled by Dimethyl Ether

Job Address: Permit #:

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

FROM OIL TO MAGNETIC FIELDS: ACTIVE AND PASSIVE VIBRATION CONTROL

2-Way and 3-Way Globe Valve Assemblies. Two-Way Pneumatic Spring Return Models

Automation systems Drive solutions Controls Inverters Motors Gearboxes Engineering Tools

3/2-Way Valve DN 15 up to DN 40

RTL. Floor Heating Controller Return temperature limiter with and without presetting

New! designline - quality and performance with appeal

Three-phase Induction Motors. Empowering the Future

SOLAR PV standard Plan-Simplified Central/String Inverter Systems for One and Two Family Dwellings

V5000. Globe Valves Series for Terminal Units. Product Bulletin

Primary Flow Rate to Plate HX [m3/hour] Pressure Drop Plate HX [kpa]

Merchant Shipping (MARPOL Annex VI - Prevention of Air Pollution) Order 2014

Associated controllers Controller selection

Safety Considerations for Truck Climbing Lanes on Rural Highways

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

SPOA10NB, SPOA10, SPO10

PVG 32 Specification Sheet. Subsidiary/Dealer. Customer. Application B-Port. B-Port. Subsidiary/Dealer PVG No.

A PASSION FOR PERFECTION PFEIFFER>-VACUUM. Pascal series. r Rotary vane pumps 5 to 21m 1 h. c u; Qj. > Ol. 5 E.;: 'O Q) o;

Emission Measurement and Testing of Multi Cylinder C.I. Engine Operated by Intercooled Turbocharger

Low Leakage Steel Door

DIRECTIONAL GROUND RELAY. Type CFPC16A. G E N E R A L ELECTRIC

WIM and dynamic loading on pavements

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Effect of Aggregate Gradation on Measured Asphalt Content

Transcription:

Produt data sheet 56.460 V6R: 2-way valve with female thread, PN 16 (el.) How energy effiieny is improved Effiieny means preise and reliable ontrol Features Regulating valve free of silione grease with female thread DIN/EN ISO 228-1 G for the ontrol of old/hot water in losed iruits In ombination with valve atuators AVM 322, AVM 322S, AVM 234S, AVF 234S Equal-perent or harateristi, an be set with SUT valve atuators (SAUTER Universal Tehnology) to or equal-perent Control pass A AB losed when the spindle is moved out Closes either against or with the pressure Valve body and seat made of gunmetal Stainless steel spindle Stuffing box made of with wiper ring and double O-ring seal made of EPDM Tehnial data Parameters Control ratio > 50:1 Leak rate 0.05% of Kvs value Valve stroke 14 mm Nominal pressure 16 bar Operating temperature1) 15...130 C Ambient onditions Operating pressure up to 120 C 16 bar Operating pressure up to 130 C 13 bar Pressure and temperature data DIN 2401 Flow parameters VDI/VDE 2173 Standards and diretives Overview of types Nominal diam- Kvs value eter Valve harateristi 0.4 m³/h equal-perent- Stainless steel 0.63 m³/h equal-perent- Stainless steel 1 m³/h equal-perent- Stainless steel 1.6 m³/h equal-perent- Stainless steel 2.5 m³/h 4 m³/h Materials for valve plug of onnetion Weight 4 m³/h V6R25F310 6.3 m³/h 10 m³/h 6.3 m³/h V6R25F200 10 m³/h DN 40 16 m³/h G1½" 3.4 kg DN 40 25 m³/h G1½" 3.4 kg 1) At temperatures below 0 C, use stuffing box heater (aessory) Right of amendment reserved 2016 Fr. Sauter AG 7.1 1/5

Produt data sheet 56.460 Nominal diameter K vs value Valve harateristi Materials for valve plug of onnetion Weight V6R40F210 DN 40 16 m³/h G1½" 3.4 kg V6R40F200 DN 40 25 m³/h G1½" 3.4 kg V6R50F300 DN 50 35 m³/h equal-perent G2" 4.6 kg V6R50F200 DN 50 35 m³/h G2" 4.6 kg Aessories Desription 0217268001 Stuffing box heater 15 W, 24 V 0217268004 Stuffing box heater 15 W, 230 V 0360391015 Srew fitting,, inl. seal, 2 ps. required 0360391025 Srew fitting,, inl. seal, 2 ps. required 0360391040 Srew fitting, DN 40, inl. seal, 2 ps. required 0360391050 Srew fitting, DN 50, inl. seal, 2 ps. required 0360421000 Adhesive label for flow hange Closes with the pressure 0378034001 Stuffing box; with syntheti lubriant; max. 130 C A 0217268*** Stuffing box heater 15 W, light alloy housing, IP 54, 3 0.75 mm² power able, earth onnetor, length 1 m, ferrule Combination of V6R with eletrial atuators / Warranty: The tehnial data and pressure differenes indiated here are appliable only in ombination with SAUTER valve atuators. The warranty does not apply if used with valve atuators from other manufaturers. / Definition of p s : Maximum admissible pressure drop in the event of a malfuntion (pipe break after the valve) at whih the atuator reliably loses the valve by means of a return spring. / Definition of p max : Maximum admissible pressure drop in ontrol mode at whih the atuator reliably opens and loses the valve. Pressure differenes Atuator AVM234SF132 AVF234SF132 AVF234SF232 AVM322F120 AVM322F122 Atuating power 2500 N 2000 N 2000 N 1000 N 1000 N Control signal pt., 0...10 V, 4...20 pt., 0...10 V, 4...20 pt., 0...10 V, 4...20 point AVM322SF132 pt., 0...10 V, 4...20 Running time 28/56/84 s 28/56/84 s 28/56/84 s 120/240 s 120/80 s Closes against the pressure V6R25F200 p [bar] p max p max p s p max p s p max p max 4.0 4.0 16.0 4.0 16.0 4.0 4.0 V6R25F310 4.0 4.0 16.0 2.0 16.0 4.0 4.0 V6R40F210 V6R40F200 V6R50F300 V6R50F200 3.0 3.0 11.5 3.0 11.5 3.0 3.0 2.0 2.0 8.6 2.0 8.6 2.0 2.0 2/5 7.1 Right of amendment reserved 2016 Fr. Sauter AG

Produt data sheet 56.460 Atuator AVM234SF132 AVF234SF132 AVF234SF232 AVM322F120 AVM322F122 Closes with the pressure AVM322SF132 p max p max p s p max p s p max p max 3.0 3.0 16.0 3.0 16.0 4.0 4.0 V6R25F310 2.0 2.0 16.0 4.0 16.0 4.0 4.0 2.0 2.0 16.0 2.0 16.0 4.0 4.0 V6R25F200 2.0 3.0 16.0 2.0 16.0 4.0 4.0 V6R40F210 V6R40F200 V6R50F300 V6R50F200 1.5 1.5 16.0 1.5 16.0 3.0 3.0 1.0 1.0 16.0 1.0 16.0 2.0 2.0 A Aessories required: Mounting set 0372338001 for AVM 234 and AVF 234 A Aessories required: Mounting set 0510240012 for AVM 322(S) Desription of operation The valve an be moved to any intermediate position with an atuator. Closes against the operating pressure Closes with the operating pressure Intended use This produt is only suitable for the purpose intended by the manufaturer, as desribed in the Desription of operation setion. All related produt regulations must also be adhered to. Changing or onverting the produt is not admissible. Engineering and fitting notes In any position exept suspended - see related atuator. When the atuator is mounted on the valve, make sure the plug is not twisted on the two stops (seats) (this an dam the sealing surfae). When insulating the valve, it may only be insulated up to the onneting lip of the atuator. To inrease the funtional reliability of the valves, the system should onform to DIN/EN 14336 (heating systems in buildings). DIN/EN 14336 states, amongst other things, that the system has to be flushed through before being put into servie. Water quality as per VDI 2035. Additional tehnial data p v V6R15F*50 4 V6R15F*40 4 V6R15F*30 4 V6R15F*20 4 V6R15F*10 4 V6R15F*00 4 V6R25F*10 4 V6R25F*00 4 V6R40F*10 3 V6R40F*00 3 V6R50F*00 2 Right of amendment reserved 2016 Fr. Sauter AG 7.1 3/5

Produt data sheet 56.460 p v in bar = maximum pressure differene over the valve at every stroke position, limited by noise level and erosion (maximum values without limitation by atuating fore) Tehnial information SAUTER slide rule for valve sizing 7090011001 Manual on slide rule 7000129001 Tehnial manual on ontrol units Parameters, fitting instrutions, ontrol Pneumati ontrol units, general information Version information 7000477001 Valve body with female thread. Sealing surfae metalli. Flat seal on body made of opper. Stuffing box with ethylene-propylene O-ring. Material number as per DIN DIN material no. DIN designation Valve body 2.1096.01 G-Cu Sn 5 Zn Pb (Rg 5) Valve seat 2.1096.01 G-Cu Sn 5 Zn Pb (Rg 5) Spindle 1.4305 X 12 Cr Ni S 18 8 Plug 2.0402.26 Cu Zn 40 Pb 2 F43 Plug V6R15F*20...F*50 1.4305 X 12 Cr Ni S 18 8 Stuffing box 2.0401.10 Cu Zn 39 Pb 3 F36 Additional details on the definitions of pressure differene p v : Maximum admissible pressure differene over the valve at every stroke position, limited by noise level and erosion. With this parameter, the valve is haraterised as a flow element with speifi hydrauli behaviour. Monitoring the avitation and erosion along with the assoiated noise inreases the servie life and the operational apaity. p max : Maximum admissible pressure differene over the valve at whih the atuator an reliably open and lose the valve. The following are onsidered: Stati pressure and flow effets. This value ensures trouble-free stroke movement and losing of the valve. The value p v of the valve is never exeeded. p s : Maximum admissible pressure differene over the valve in the event of a malfuntion (e.g. power failure, exessive temperature or pressure, pipe break) at whih the atuator an lose the valve tightly and, if neessary, maintain the full operating pressure against atmospheri pressure. Beause this is a safety funtion with a rapid stroke movement, p s an be greater than p max or p v. The disruptive flow effets that arise here are quikly passed through and are of minor importane in this mode of operation. For 3-way valves, the values only apply to the ontrol pass. p stat : Line pressure behind the valve. This essentially orresponds to the idle pressure when the pump is swithed off, aused for example by the fluid level in the system, inreased pressure due to pressure tanks, steam pressure, et. For valves that lose with pressure, the stati pressure plus the pump pressure are used. Disposal When disposing of the produt, observe the urrently appliable loal laws. More information on materials an be found in the Delaration on materials and the environment for this produt. 4/5 7.1 Right of amendment reserved 2016 Fr. Sauter AG

Produt data sheet 56.460 Dimension drawings for 5M100 V6R Ø38 M10 H 99 Hub Course Stroke 14mm a Rp (Zubehör) (aessoire) (aessory) G(DN) L L1 15 25 40 50 DN 1/2" 1" 1 1/2" 2" a 56 59 76 98 29 33 47 57 H L L1 G Rp 184 85 159 1/2 1/2 191 110 196 1 1 222 150 256 1 1/2 1 1/2 254 180 294 2 2 Combinations AVF 2** AVM 2.. > 150 289 (382) > 150 289 (382) Determining the length: Take dimension from the valve dimension drawing Fr. Sauter AG Im Surinam 55 CH-4016 Basel Tel. +41 61-695 55 55 www.sauter-ontrols.om Right of amendment reserved 2016 Fr. Sauter AG 7.1 5/5