BRUSHLESS DC MOTOR UNIT - L Series DIMENSIONS KLHN2 + KH BTH (Weight : 1.2Kg) 47.7 3 B B Ø.03 0 (H) MOTOR CABLE Ø 500mm A HOUSING: 22-(AMP) 4 KEY KEY GROOVE (ACCESSORY) 25±0.2 4 +0.03 4 +0.03 4 +0.03 2.5 +0.1 4 +0.04 4-Ø4.5HOLE 13. Ø12.5 +0..5 42 3.7 Ø12 +0.027 (H) 1. 1. Ø12 +0.027 (H) Ø12.5 +0. CONNECTOR HOUSING (VIEW A) P.C.D Ø70±0.5 120.5 SECTION B-B PIN MAP PIN No. COLOR SIGNAL MOTOR PRODUCT NAME GEARHEAD PRODUCT NAME DECELERATION RATIO * In of name, it represents a deceleration ratio. * Mounting bolt sets are included in flat type gearbox. M5 5L (flat washer, spring washer, hexagonal nut 4pcs each) FIXING BOLT KBH200NC KH BTH 5~200 M P1.25 0 1 GRAY W 2 PURPLE V 3 BLUE U 4 YELLOW Vcc 5 GREEN Ground ORANGE Hw 7 WHITE Hv BROWN Hu 33
Specification Product name GEAR TYPE KLHN2 KLH50N2 KLH100N2 D-CUT TYPE KLSN2 KLS50N2 KLS100N2 Rating output (continuous) W 50 100 Rating voltage V DC24 Power input Rating voltage allowance ±10% Rating input current A 2.1 3.1.0 Rating output current A 3.7. Rating torque N m(kgf cm) 0.12 0.2 0.4 Starting torque N m(kgf cm) 0. 0.24 0.5 Rating rotation speed r/min 2500 Speed control range r/min 100~00 Allowed inertia load moment of round shaft type Rotor inertia moment -4 2 J 10 kg m 3.3 5. -4 2 J 10 kg m 0.0 0.2 0. Speed change rate Load Voltage Temperature Less than or equal to ±1% : condition 0-rated torque, rated rotation speed, rated voltage, room temperature Less than or equal to ±1% : condition rating voltage ±10%, rating rotation speed, no load, room temperature Less than or equal to ±1% : condition surrounding temperature 0~+40, rating rotation speed, no load, rating voltage * The usage duration for stabting torque is within 5 seconds at less than 2000 r/min * Each specification value is the characteristic of motor by itself Common specifications Product name Rotation speed setting method Acceleration time deceleration time Set up by external potentiometer Set up by external DC 0~5V Specification 0.5~10 seconds : set at 2000 r/min when there is no load (it may change depending on the size of the load) Accleration time and deceleration control equipment to control at the same time Input signal Output signal Protection function Motor insulation class Maximum extension distance Rated time Internal full-up input method, external input voltage read as greater than 2v high(off) same at all input ports Open collector output, common for speed out/alarm out, if input voltage from out side is applied to connector #2 pin, then it comes out through the applied power. Everything else is internal 5V ouput UI(CTRL) If the following protection mode comes on, cotrol unit alarm signal is shown. Motor stops automatically. Overload protection mode : If torque that is greater than the rating is applied to the motor for more than 5 seconds Overvoltage protection : If voltage applied to the control unit goes over the upper bound of the rating allowance Open phase protection : If cable sensor line gets disconnected during motor operation Undervoltage protection : If voltage applied to the control unit is less than the lower bound of th rating voltage allowance Over speed protection : If motor rotation speed is faster than 2500 r/min E TYPE(120 ) MOTOR - CONTROL UNIT 2m Continuous * Like weight carried being downwards, L SERIES cannot control motor speed through weight. Motor gets stopped automatically through overvoltage protection of load is being carried downwards or it is heavier than allowed load inertia. 3
Normal specifications Items Motor Control unit Insulation Resistance Dielectric Strength Used Conservation Insulation class Used temperature Used Humidity Vibration Vibration temperature Humidity Altitude temperature and humidity, the value measured between coil and vase by DC 500V MEGA is greater than or equal to 100MΩ temperature and humidity, there shouldn t be any problem between coil and case even when AC 0.5kV is applied for 1 minute * Preservation is a short-term value, which includes transportation. * Do not measure insulation resistance and pressure resistance while motor and driver are connected Allowed torque of combination type 0 ~+50 (should not freeze) less than or equal to % (not from dews) temperature and humidity, the value measured between heatproof plate and power input is greater than or equal to 100MΩ No problem when 50Hz, AC 0.5kV is applied for one minute No problem when AC 0.5kV is applied for one minute Altitude less than 1000m Cannot be used under special circumstances such as with corrosive gas, dust, radioactive material, magnetic and vacuum Should not apply constant vibration or huge impact according to the JIS C 0-2- sine wave vibration test method Frequency range : 10~55Hz, peak amplitude : 0.mm, sweet direction : 3 direction(x,y,z), number of sweeps : 20 times UL, CSA STANDARD A TYPE(105 ), EN STANDARD E TYPE(120 ) -25 ~ +70 (should not freeze) less than or equal to % (not form dews ) Altitude less than 00m Protection class IP5 IP00 Items Deceleration ratio 5 10 20 50 100 200 Speed control range [r/min] KLHN2 + KH B KLH50N2 + KH B KLH100N2 + KH B KLHN2 + KH BTH KLH50N2 + KH BTH KLH100N2 + KH BTH 20~500 10~250.7~7 5~125 3.3~3 2~50 1~25 0.5~12.5 0 0 200 0 100 0.54 0.27 0. 0.45 4.5 0. 0.4 4. 0.24 2.4 0. 0.43 0. 1.1 0.54 0. 3. 3 1 10 0. 0. 1. 0.1.1 27 1.4 54 27 0.77 7.7 1.3 13 2.2 22 1.1 3. 3 7.2 72 3. 3 2 20 1 10. 3.1 10.3 103 3.1 Unit = upper part : N m / lower part : kgf cm. 43.2 2. 43 0 1. 0.2 2 0 0 0 1 1 0 0 0 0 0 0 0 * Rotation direction shows the same color as the motor. In other cases, it s the opposite. * Flat Gearbox viewed from front side is opposite rotation direction with motor. Flat Gearbox viewed from back side is same rotation direction with motor. 3
Allowed overhang load and allowed thrust Allowed overhand load Product name Deceleration ratio From the end of output part : 10mm From the end of output part : 20mm Allowed thrust load N kgf N kgf N kgf 5 100 10 0 KLHN2 + KH B 10~20 0 200 20 40 4 ~200 200 20 0 5 200 20 250 25 KLH50N2 + KH B 10~20 0 350 35 100 10 ~200 450 45 550 55 5 0 400 40 GEARED MOTOR KLH100N2 + KH B 10~20 400 40 500 50 ~200 500 50 50 5 0 KLHN2 + KH BTH 5~10 450 45 370 37 ~200 500 50 400 40 200 20 KLH50N2 + KH BTH 5~10 00 0 ~200 1200 120 1000 100 400 40 5~10 00 0 770 77 KLH100N2 + KH BTH ~20 10 1 10 1 500 50 ~200 00 0 120 12 MOTOR KLSN2 70 7 100 10 KLS50N2 120 12 0 KLS100N2 1 0 Be careful not to weigh thrust. If it s inevitable, keep it under 50% of the motor weight. * In of name, it represents a deceleration ratio. * Permissible overhang load can be withdrawn by calulation. 40
Rotation speed- torque characteristic KLSN2 / KLHN2 Short time KLS50N2 / KLH50N2 Short time KLS100N2 / KLH100N2 Short time 41