Art. E3 - OPERATOR GROUND CHECK DUAL SHOES AND WRISTBAND TESTER Meets IEC STD : 2007

Similar documents
ACL 780/781 Economy Combo Tester

Warmbier Germany, Wrist Strap & Footwear Combo Tester

50407 / DUAL INDEPENDENT FOOTWEAR AND WRIST STRAP TESTER

3 740 Wrist strap + shoe tester

746 Wrist Strap Tester Installation, Operation and Maintenance

VARIABLE RESISTANCE REFERENCE PAR-809C. User Manual

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

Development Board ESD Benchtop Kit

Installing Power Components

Limit Comparator for Testers

CONTENTS PRODUCT DESCRIPTION Functional Description: NO Switch Functional Description: Illumination...

PRO series programmer

WATERFLUX 3070 Quick Start

USER S MANUAL TUBE SEALER. Model SE700. No. CAT.SE70011Ce

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

Metal Hand-Held Linear Battery Charger/Starter

Avoid nasty shocks Electrical safety for industry

Autoranging Multimeter

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

LED Downlight Ceiling Fixtures

Plunger Heads Use and Maintenance Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Datasheet. Electrical Switching / Locking

Model UPS NXRT-1000 NXRT-1500 NXRT-2000 NXRT-3000 Model EBP NXRT-EBP1 NXRT-EBP2 NXRT-EBP3 NXRT-EBP3

CLOUDBOX Quick Start Guide

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

Installation and Operations Manual

User Manual Rittal PMC UPS 6kVA

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Functions The Series 19 incorporates the following functions: Indicator Pushbutton Illuminated pushbutton

BREAK-SAFE Load Break & Pick-up Tool

True RMS Autoranging Multimeter

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

Constant Voltage/Constant Current Test System

Blancett Flow Meters A Division of Racine Federated Inc. 100 East Felix Street South, Suite 190 Fort Worth, Texas FAX:

Car Battery Charger Instructions for Use

Operation Manual. Mega 4Bank DMX Universal

Competitor. Ultra Light Plus, Semi Electric Bed. Item # Owner s Assembly And Operating Manual

SUBDISTRICTS LEGAL DESCRIPTIONS DELETED FOR BREVITY. (60.1) WINDOW SIGN means a sign painted or affixed to a window.

Silvertel. Ag Features. 2. Description. Power-Over-Ethernet Module. IEEE802.3af compliant. Small SIL and SMT package available

Milford Communications Battery Back-Up Notice

General_technical_data Series

Autoranging Industrial Multimeter

OPERATING INSTRUCTION

Power and Cooling. Chassis Power System

Emergency lighting units EM powerled

Ultrasonic Level Switch

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Operating instructions Flow monitors SI5000 SI / / 2007

EPS/ELA-Series User Manual EPS/ELA 250W

GRD502-B Flow Chart 02/05/09

Wander Control Systems, Inc.

DC-Motor Controller. User Manual

OPERATING INSTRUCTION

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

The Forte' Launch Controller

FUSERBLOC CD. The universal Fuse Combination Switch FROM 20 TO 1250 A. Industrial Switching & Protection Systems

Sola 3000 Guide Specifications

RELAY BOX PRODUCT MANUAL IMPORTANT

The BVX-100 Fume Extraction System

Operating the Network Control Module (NCM) Battery Charger/Tester

1 AMP CURRENT SOURCE

SAFE & SECURE ACTUATOR PRODUCT MANUAL

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software

Emergency lighting units EM powerled

Competitor. Ultra Light Plus, Semi Electric Bed. Item # 15560, HR Owner s Assembly And Operating Manual

HT-25kVdc Dielectric Withstand Tester Volts DC Output

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Basic Electronics Course Part 1

International & MB45/55 w/allison 2000 and Shift Lock Solenoid

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Sense7-series Non-contact coded safety switch

Troubleshooting Bosch Proportional Valves

PBS M Marine Push Button Start

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

30A SMART ENERGY MANAGEMENT SYSTEM TM

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

18VDC ESB6-X Series Cordless Screwdrivers Operation Manual

Operating Instructions Overcurrent Protection - Tester

Installation Instructions

12/24 Volt Trailer, Caravan Electrical Tow Plug And Light Tester

User s Manual. Automatic Switch-Mode Battery Charger

Uninterruptible Power Supplies

Engineering Standards. Engineering Standard Number C A. Name. Digital Breathing Air Remaining System BREATHING AIR

DESIGNED BY EXPERIENCE PLASTIC SPHERE DISPENSER USER MANUAL. Manufactured by PSDS, Inc. for sole distribution by:

3 OSLON +80 PowerAnna PCB Colours

Powerware Vdc Extended Battery Cabinet User s Guide.

When: Task: See job aid:

POWERLINE 2000 Energy Management System TM

INSP-3 Wiring Inspection Tester

Transcription:

Elme S.r.l. Via Arosio, 4 Milano (MI) I 20148 Italy - www.elme.it infoesd@elme.it Tel: +39 02 4009.2076 Fax: +39 02 4009.1993 Technical data sheet # TST38E Art. E3 - OPERATOR GROUND CHECK DUAL SHOES AND WRISTBAND TESTER Meets IEC STD 61340-5-1 : 2007 GENERAL ELME E3 DUAL TESTER has been designed to test the performance of ESD wrist straps and footwears such as clogs, shoes, sandals or foot-grounders. E3 is designed to operate tests in accordance with IEC 61340-5-1:2007 standard (table 1). E3 performs test on the ESD wristband and the ESD footwears automatically. The operator can easily select the test to perform. E3 includes a dual foot plate in order to verify the conductivity of the left and right foot separately and simultaneously.

AVAILABLE MODELS E3 SE E3 SPSE E3 SD E3 SPSD E3 SPSU 110V (USA) MEW0002001 MEW0002011 MEW0002000 MEW0002010 MEW0002015 E3 tester E3 tester E3 tester E3 tester E3 tester (German (German instructions) instructions) 9V battery 9V battery 9V battery 9V battery 9V battery 110V Manual Manual Manual Manual Manual Carton box Carton box Carton box Carton box Carton box 3,6 Kg total 3,8 Kg total 3,6 Kg total 3,8 Kg total 3,8 Kg total MODELS WITH STAND E3 STAND E3 SPSE SE STAND E3 SD STAND E3 SPSD STAND E3 SPSU STAND 110V (USA) MEW0002021 MEW0002031 MEW0002020 MEW0002030 MEW0002035 E3 tester E3 tester E3 tester E3 tester E3 tester Metal stand Metal stand Metal stand Metal stand Metal stand 9V battery 9V battery 9V battery 9V battery 9V battery 110V Manual Manual Manual Manual Manual Carton box Carton box Carton box Carton box Carton box 12.8Kg total 13,0Kg total 12,8Kg total 13,0Kg total 13,0Kg total

E3 E3 STAND E3 INCLUDES INSTALLATION The E3 has been designed for a wall application (wall mount). Hang or glue the yellow to a protected location at the entrance of the EPA, assuming that the personnel will perform the test before entering the area. Ideally, the best location is at the entrance of the production line, in order to allow the preventive test procedures before starting the daily work. TESTING PROCEDURE MODE SELECTION

On the top right you find the MODE SELECTOR which enables you to select the kind of test you like to perform 1. WRISTBAND ONLY 2. FOOTWEARS ONLY 3. WRISTBAND AND FOOTWEARS mode selector L.E.D. INDICATIONS The L.E.D. indication is designed to provide an immediate visual reading of the results of the performed test on footwears and wristbands HI L.E.D.s (red colour) indicate that the equipment (footwears and/or wristbands) show an electrical resistance too high, exceeding the top limit of the correct range PASS L.E.D.s (green colour) indicate that the ESD equipment (footwears and/or wristbands) show correct electrical resistance values (within the range) LOW L.E.D.s (red colour) indicate that the equipment (footwears and/or wristbands) show an electrical resistance too low, exceeding the bottom limit of the correct range TESTING WRISTBANDS ONLY 1. turn the selector on the left position indicating the hand 2. wear your wristband tight as recommended for a good electrical connection 3. connect the cord to the wristband 4. connect the other end of the cord to the respective receptacle (choose if banana or snap on the front of the E3) 5. press and hold the metal plate on the front of the E3 6. the coloured L.E.D.s will shine (HI, LOW or PASS) wristband L.E.D.s

TESTING FOOTWEARS ONLY 1. turn the selector on the top position indicating the shoe 2. check that your ESD shoes have a clean sole in order to provide the best electrical contact. A dirty sole will increase your electrical resistance to ground and will not allow a correct test 3. wear your left and right ESD shoes as indicated by the instructions for a good electrical connection with your feet 4. step on the dual plate positioning your feet on the two metal plates (place your feet ensuring that the soles of the shoes are placed in the centre of each metal plate) 5. press and hold the metal plate on the front of the E3 6. the coloured L.E.D.s will shine respectively for the left footwear and the right footwear (HI, LOW or PASS) footwears L.E.D.s TESTING FOOTWEARS AND BANDS 1. turn the selector on the right position indicating the shoe + hand 2. wear correctly the wristband and the ESD shoes 3. connect the wristband cord to the E3 respective receptacle and step on the dual foot plate placing your feet on the respective metal plates (left and right foot) 4. press and hold the metal plate on the front of the E3 5. the coloured L.E.D.s will shine respectively for the left foot, the right foot and the wristband (HI, LOW and PASS) WRISTBAND CONNECTIONS Snap Banana

The E3 has input connections for all kinds of available on the market: 4mm banana receptacle (allows both standard and reverse banana plugs) 10mm male snap DUAL BANDS CORDS bi-polar receptacle designed for special dual bands mainly used with resistance-based permanent monitors TOUCH PLATE The metal touch plate is designed to provide the electrical contact between the skin of the operator and the monitor. Typically, the operator presses on the plate with his finger and holds pressure until the L.E.D.s shine giving the desired indication BATTERY INDICATION The E3 operates with batteries or with external power supply. When operating with batteries, the LED indications LOW BATTERY will advise about status of charge. The LED shines amber colour when the battery is low of charge FOOT PLATE CONNECTION On the lower part of the E3 is located the input receptacle of the connection cord from the tester to the foot plate. The cord connects the dual foot plate providing informations for the left and right foot

DOOR OPENER Unique feature of the E3 is the door-opening system. On the lower part of the tester is located the NO-NC relay connection for the electrical door opening control system. In this way the E3 can discriminate the access to EPA restricted areas. For technical application on electrical opening door systems or other different applications please see specific instructions. Controls and readings on the E3** Test Mode Wristband LED Left Foot LED Right Foot LED Buzzer Door Opener Wristband Only OFF OFF Silent Door Open Footwears Only Wristband & Footwears FAIL: red OFF OFF Pulse Door Closed OFF Silent Door Open only if both feet PASS OFF FAIL: red FAIL: red Continuous Door Closed OFF OFF FAIL: red FAIL: red FAIL: red FAIL: red FAIL: red Continuous Door Closed FAIL: red Continuous Door Closed Silent Door Open only if both feet an wristband PASS FAIL: red FAIL: red Continuous Door Closed FAIL: red Continuous Door Closed FAIL: red Continuous Door Closed Pulse Door Closed FAIL: red FAIL: red Pulse Door Closed FAIL: red ** the FAIL reading will show HI or LOW fail, illuminating the higher or the lower red LED Pulse Door Closed FAIL: red Pulse Door Closed Resistance reference values range on the E3 (according to IEC 61340-5-1 std.) Item Tested Lower limit Upper limit Wristband 750 Kohm 35 MOhm Footwear (primary grounding) 100 KOhm 35 MOhm Footwear (combined grounding)** 100 KOhm 100 MOhm ** when footwears are used in combination with wristbands, turn the MODE SELECTOR on the right position (shoe + hand symbols): the range testing the shoes will automatically switch to the correct values.

TECHNICAL INFORMATIONS tester dimensions / 158x95x60mm tester 240 gr tester with battery 280 gr dimensions 380x380x8mm power supply battery 9V external power supply (optional) AC/ 9VDC colour white box, yellow/black, coloured LEDs accuracy +/- 10% Test voltage 28V Meets IEC 61340-5-1:2007 The datas shown above are intended only as general indication of the standard production values. The do not refer to specific production lots. The document has no legal value. ELME srl Milano