INSTALLATION AND OPERATING INSTRUCTIONS. 579 Series BRISK AIR 590 Series QUICK COOL 595 Series QUICK COOL Roof Top Air Conditioner USED WITH

Similar documents
INSTALLATION INSTRUCTIONS

Roof Top Unit. Description Model Use With Return Air Grill XXX OR XXX

DUCTED THIS UNIT IS DESIGNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT.

MODELS , , , &

INSTRUCTIONS INSTALLATION. Read these instructions carefully. These instructions MUST stay with this product.

Roof Top Unit Used With Air Distribution Box Description Model Board Built In OR Electronic Control Kit Air Conditioner

Owner s Information Manual

Installation Instructions

Safety Notices. Dear user, thank you for choosing a HOUGHTON caravan air-conditioner. For your

ERV ENERGY RECOVERY VENTILATOR 60 HZ. Indoor / Outdoor 500 to 10,000 cfm Capacity ERV I - D - D - P - 1 MODEL NUMBER IDENTIFICATION

Installation Instructions

SERVICE INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

ZHA/ZHB SERIES WARNING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

GSX 16 SEER Condensing Units

PCB COMMERCIAL SERIES

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

Installation Instructions

Installation Instructions

Installation Instructions

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

UV-AIRE AIR PURIFYING SYSTEM

Installation Instructions

TECHNICAL INFORMATION MANUAL

10AC DIPLOMAT SERIES RFC SYSTEMS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

EasyStart Installation Instructions for Dometic Family RV A/Cs

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

ASSEMBLY AND INSTALLATION INSTRUCTIONS

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

Installation Instructions

TECHNICAL MANUAL. GSC/VSC13 SEER Condensing Units with R-22

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST MUSTANG

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

ELITE SERIES R-410A Ready - Multi-Position

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Inspection Points - Motor Homes

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

PRPAC14 PRODUCT SPECIFICATIONS 14 SEER ELECTRIC/ELECTRIC PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER INSTALLATION WARRANTY

PRAC14 PRODUCT SPECIFICATIONS

Installation Instructions

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

Q7RE Series Single Packaged Heat Pump, Single Phase

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

5300 Series Installation Guidelines

AIR COOLED CHILLERS WATER COOLED CHILLERS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

X100P Load Bank. Read all instructions before using the load bank. Contents

Installation Instructions

& 76 CHEVROLET NOVA HEATER ONLY

INSTALLATION INSTRUCTIONS

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

TSA6. Product Specifications. SmartComfort TXC 5600

Environmental Series Air Curtains

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

CSA CERTIFIED Conforms to UL 507

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

INSTALLATION INSTRUCTIONS

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

Typical Applications. Horizontal Installation

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES YTG-A-0806

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

Model 8144NC Fresh Air Ventilator

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

P7RE Series Single Packaged Air Conditioner

Direct Gas-Fired Heating

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

M-3025CB-AV Fuel Pump

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

PA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Vehicle Rear Observation System With Integrated Parking Sensors

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

REFRIGERATION COOLERS

PA55 10 SEER FEATURES 2 THRU 5 TON SINGLE PACKAGE AIR CONDITIONER

TECHNICAL INSTRUCTIONS

POWERLINE 2000 Energy Management System TM

PLASTIC FOLDING ARM KIT This kit is designed for the 1600 model barrier gate operators only. Recommended for low headroom applications.

Package Unit Modulating Economizer Installation Instructions

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

SSZ 14 SEER Split System Heat Pumps

LIGHT COMMERCIAL - 3 HP ECM MOTOR / CONTROLLER HIGH STATIC DRIVE KITS

Q5RD Series Single Packaged Heat Pump, Single Phase

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

Transcription:

USA SERVICE OFFICE Dometic Corp. 509 So. Poplar St. LaGrange, IN 46761 (260) 463-4858 579 Series BRISK AIR 590 Series QUICK COOL 595 Series QUICK COOL Roof Top Air Conditioner USED WITH Part No. 3107206 Air Distribution Box Kit Mechanical RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number Serial Number Date Purchased PRE-WIRED FOR OPTIONAL HEAT PACKAGE CANADA Dometic Dist. 866 Langs Dr. Cambridge, Ontario CANADA N3H 2N7 (519) 653-4390 For Service Center Assistance Call: 800-544-4881 This manual must be read and understood before installation, adjustment, service, or maintenance is performed. This unit must be installed by a qualified service technician. Modification of this product can be extremely hazardous and could result in personal injury or property damage. C US Lire et comprendre ce manuel avant de procéder à l'installation, à des réglages, de l'entretien ou des réparations. L'installation de cet appareil doit être effectuée par un réparateur qualifié. Toute modification de cet appareil peut être extrêmement dangereuse et entraîner des blessures ou dommages matériels. INSTALLATION & OPERATING INSTRUCTIONS REVISION: Form No. 3107195.095 11/03 (Replaces 3107195.087) (French 3108172.052) 2003 Dometic Corporation LaGrange, IN 46761 1 57908.521 57912.621 57912.622 57912.631 57915.322 57915.331 57915.421 Important: These instructions must stay with unit. Owner read carefully. MODELS 57915.422 57915.521 57915.522 57915.531 57915.536 57915.541 57915.546 57915.621 57915.622 57915.631 59016.521 59016.621 59516.303 59516.331 59516.501 59516.531 59516.536 59516.601 59516.603 59516.631

SAFETY INSTRUCTIONS This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMATION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury. Follow recommended precautions and safe operating instructions. UNDERSTAND SIGNAL WORDS A signal word, WARNING OR is used with the safety-alert symbol. They give the level of risk for potential injury.! indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.! WARNING! indicates a potentially hazardous situation which, if not avoided may result in minor or moderate injury. used without the safety alert symbol indicates, a potentially hazardous situation which, if not avoided may result in property damage. Read and follow all safety information and instructions. GENERAL INFORMATION A. This air conditioner is designed for: 1. Installation on a recreational vehicle during or after the time the vehicle is manufactured. 2. Mounting on the roof of a recreational vehicle. 3. Roof construction with rafters/joists on minimum of 16 inch centers. 4. Minimum of 1.00 inches and maximum of 4 inches distance between roof to ceiling of recreational vehicle. Alternate installation methods will allow for roofs more than 4 inches thick. B. The ability of the air conditioner to maintain the desired inside temperature depends on the heat gain of the RV. Some preventative measures taken by the occupants of the RV can reduce the heat gain and improve the performance of the air conditioner. During extremely high outdoor temperatures, the heat gain of the vehicle may be reduced by: 1. Parking the RV in a shaded area 2. Using window shades (blinds and/or cur tains) 3. Keeping windows and doors shut or minimizing usage 4. Avoiding the use of heat producing appli ances Operation on High Fan/Cooling mode will give optimum or maximum efficiency in high humidity or high outside temperature. Starting the air conditioner early in the morning and giving it a "head start" on the expected high outdoor ambient will greatly improve its ability to maintain the desired indoor temperature. For a more permanent solution to a high heat gain, accessories like A&E outdoor patio and window awnings will reduce heat gain by removing the direct exposure to the sun. They also add a nice area to enjoy company during the cool of the evening. C. Condensation Note: The manufacturer of this air conditioner will not be responsible for damage caused by condensed moisture on ceilings or other surfaces. Air contains moisture and this moisture tends to condense on cold surfaces. When air enters the RV, condensed moisture may appear on the ceiling, windows, metal parts, etc. The air conditioner removes this moisture from the air during normal operation. Keeping doors and windows closed when this air conditioner is in operation will minimize condensed moisture on cold surfaces. 2

SPECIFICATIONS MODEL NOMINAL ELECTRICAL COMPRESSOR COMPRESSOR FAN MOTOR FAN MOTOR SCFM-HIGH TOTAL REFRIGERANT MINIMUM AC CIRCUIT INSTALLED MINIMUM NO. CAPACITY RATING RATED LOAD LOCKED RATED LOAD LOCKED SPEED STATIC R-22 (OZ) WIRE SIZE* PROTECTION WEIGHT GENERATOR (BTU/HR) AMPS ROTOR AMPS ROTOR MAX/MIN MAX/MIN *** USER (POUNDS) SIZE** COOLING AMPS AMPS W. C. SUPPLIED 1 UNIT/ 2 UNITS 57908.321 7,180 115VAC, 6.9 36.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 12 AWG 20 Amp 75 2.5 KW / 4.0 KW 57908.521 7,100 60 HZ., 1PH. 6.6 34.0 2.5 5.8 325 / 250 0.55 / 0.90 17.0 Copper 20 Amp 75 2.5 KW / 4.0 KW 57912.321 11,000 9.5 53.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 up to 24 20 Amp 94 2.5 KW / 4.0 KW 57912.531 11,000 8.0 53.0 2.5 5.8 325 / 250 0.55 / 0.90 18.5 20 Amp 94 2.5 KW / 4.0 KW 57912.621 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 2.5 KW / 4.0 KW 57912.622 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW 57912.631 11,000 8.5 48.3 2.5 5.8 325 / 250 0.55 / 0.90 18.0 20 Amp 94 2.5 KW / 4.0 KW 57915.322 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 100 3.5 KW / 5.0 KW 57915.331 13,500 11.4 58.0 2.5 5.8 325 / 250 0.55 / 0.90 15.5 20 Amp 100 3.5 KW / 5.0 KW 57915.336 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 100 3.5 KW / 5.0 KW 57915.421 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 13.5 20 Amp 100 3.5 KW / 5.0 KW 57915.422 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 14.5 20 Amp 100 3.5 KW / 5.0 KW 57915.426 13,500 11.5 50.0 2.5 5.8 325 / 250 0.55 / 0.90 13.5 20 Amp 100 3.5 KW / 5.0 KW 57915.521 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.522 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW 57915.526 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.531 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW 57915.536 13,500 12.1 59.0 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW 57915.541 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.546 13,500 11.3 62.0 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.621 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.622 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW 57915.626 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.0 20 Amp 94 3.5 KW / 5.0 KW 57915.631 13,500 11.0 54.4 2.5 5.8 325 / 250 0.55 / 0.90 16.5 20 Amp 94 3.5 KW / 5.0 KW 57915.731 13,500 11.3 56.0 2.5 5.8 325 / 250 0.55 / 0.90 15.0 20 Amp 94 3.5 KW / 5.0 KW 59016.521 15,000 12.9 71.0 2.5 6.0 350 / 250 0.40 /1.1 0 26.5 20 Amp 101 3.5 KW / 5.0 KW 59516.303 15,000 12.7 60.0 2.0 5.6 350 / 250 0.40/1.10 29.0 20 Amp 94 3.5 KW/ 5.0 KW 59016.621 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 26.5 20 Amp 101 3.5 KW / 5.0 KW 59516.331 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29.0 20 Amp 94 3.5 KW / 5.0 KW 59516.336 15,000 12.7 60.0 2.0 5.6 325 / 250 0.40 / 1.10 29.0 20 Amp 94 3.5 KW / 5.0 KW 59516.501 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 31.0 20 Amp 94 3.5 KW / 5.0 KW 59516.531 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 26.5 20 Amp 94 3.5 KW / 5.0 KW 59516.536 15,000 11.5 50.0 2.5 5.8 325 / 250 0.40 / 1.10 29 20 Amp 94 3.5 KW / 5.0 KW 59516.601 15,000 12.9 77.0 2.5 6.0 350 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW 59516.603 15,000 12.3 77.0 2.0 5.6 325 / 250 0.40 / 1.10 29.5 20 Amp 102 3.5 KW / 5.0 KW 59516.606 15,000 12.9 71.0 2.0 6.0 325 / 250 0.40 / 1.10 31.0 20 Amp 102 3.5 KW / 5.0 KW * For wire lengths over 24 ft. consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences people have had in actual applications When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose power at high altitudes and from lack of maintenance. *** CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required. 3

1. PRES! INSTALLATION AND OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNING Improper installation may damage equipment, could endanger life, cause serious injury and/or property damage. FIG. 1 1/2 L L A. Read installation and operating instructions carefully before attempting to start your air conditioner installation. B. The Dometic Corporation will not be liable for any damages or injury incurred due to failure in following these instructions. C. Installation must comply with the National Electrical Code and any State or Local Codes or regulations. D. DO NOT add any devices or accessories to this air conditioner except those specifically authorized by Dometic. E. This equipment must be serviced by qualified personnel and some states require these people to be licensed. 2. CHOOSING LOCATION FOR THE AIR CONDITIONER This air conditioner is specifically designed for installation on the roof of a recreational vehicle (RV). It is the responsibility of the installer of this air conditioner/heat pump system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. Water standing around the air conditioner/heat pump may leak into the interior causing damage to the product and the RV. A. NORMAL LOCATIONS: The air conditioner is designed to fit over an existing roof vent opening. When the vent is removed, it normally creates a 14-1/4" x 14-1/4" ±1/8 opening. B. OTHER LOCATIONS: When no roof vent is available or another location is desired, the following is recommended: a. For one unit installation: The air conditioner should be mounted slightly forward of center (front to back) and centered from side to side. See FIG. 1. b. For two unit installations: Install one air conditioners 1/3 and one air conditioner 2/3's from front of RV and centered from side to side. See FIG. 2. FIG. 2 L 2/3 L 1/3 L It is preferred that this air conditioner be installed in a relatively flat and level roof section measured with the RV parked on a level surface; however, up to 15 o slant to either side, or front-to-back, is acceptable. C. AFTER LOCATION SELECTION: a. Check for obstructions in the area where air conditioner will be installed. b. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement. c. Check inside the RV for air box obstructions. (i.e. door openings, room dividers, curtains, ceiling fixtures, etc.) See FIG. 3. 4

FIG. 3 FIG. 4 12.7" * 34.4" 29.5" 7-5/8" 5-1/4" 14-7/8" Rear of Unit *10.7" FOR MODEL 57908 7-5/8" 22.5" 20" 14-1/4" x 14-1/4" ±1/8 18" 2.5" 3" Front of Unit 20" 3. ROOF PREPARATION A. ROOF VENT REMOVAL: 1. Unscrew and remove the roof vent. 2. Remove all caulking compound around opening. 3. Seal all screw holes and seams where the roof gasket will be located. Use a good grade of all weather sealer. B. NEW OPENING: (Installations Other Then Vent s)! WARNING There may be electrical wiring between the roof and the ceiling. Disconnect 115 volt AC power cord and the positive (+) 12 volt DC terminal at the supply battery. Failure to follow this instruction may create a shock hazard causing death or severe personal injury. 1. A 14-1/4" x 14-1/4"±1/8 opening must be cut through the roof and ceiling of the RV. It is recommended this opening be located between roof reinforcing members. 2. Mark a 14-1/4" x 14-1/4"±1/8 square on the roof and carefully cut the opening. 3. Using the roof opening as a guide, cut the matching hole in the ceiling. See FIG.4. C. OPENING PREPARATION: 1. If the opening exceeds 14-3/8" x 14-3/8", it will be necessary to install spacers. 2. If the opening is less than 14-1/8" x 14-1/8", it must be enlarged. 11-1/4" 11-1/4" 2-3/4" 3. Route a copper 12 AWG, with ground, supply line from the fuse or circuit breaker box to the roof opening. a. The power supply must be on a separate 20 amp Time Delay Fuse or HACR Circuit Breaker. b. Wiring must comply with all National, State and Local wiring codes. c. Make sure at least 15" of wire extend into the roof opening. This insures easy air conditioner attachment. d. If vent fan was removed, the existing wire may be used provided it is of proper size and correctly fused. It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. Water standing around the air conditioner may leak into the interior causing damage to the product and the RV. 4. The opening must be framed to provide adequate support and prevent air from being drawn from the roof cavity. Lumber 3/4" thick or more and long enough to bridge the opening must be used. Remember to provide and entrance hole for the power supply wire. See FIG. 5. 5

3/4" Min. Frame Provide Hole For Wiring FIG. 7 Recycle All Cardboard FIG. 5 This completes the outside work. Minor adjustments can be done from the inside if required. 5. The 14-1/4" x 14-1/4"±1/8 roof opening is part of the return air duct and must be finished in accordance with NFPA standard 501C, Standard for Recreational Vehicles, Section 2-7. 4. PLACING THE AIR CONDITIONER ON THE ROOF A. Remove the Air Conditioner from the carton and discard the carton. This unit weighs approximately 100 pounds. To prevent back injury, use a mechanical hoist to place air conditioner on roof. 5. DISCHARGE DUCT AND CEILING TEM- PLATE INSTALLATION A. Remove air box and mounting hardware from carton. The upper duct is shipped inside the lower duct which is part of the ceiling template. 1. Remove upper duct from ceiling template and locate it over blower discharge. Note: Edges without flanges install toward REAR and SIDE of opening. See FIG. 8. FIG. 8 B. Place the air conditioner on the roof. C. Lift and place the unit over the prepared opening using the gasket as a guide. The condenser coil goes toward the rear of the RV. See FIG. 6. FIG. 6 Lift And Place Front Do Not Slide 2. Use two (2) #10 x 3/8" screws (C) to hold duct to base pan. Holes provided in bottom of basepan for these screws to go into. B. Check for correct alignment and adjust the unit as necessary (Roof Gasket centers over 14-1/4"±1/8 opening). C. Reach up into return air opening of the air conditioner and pull the unit electrical cord down for later connection. See FIG. 9. Do not slide the unit. This may damage the neoprene gasket attached to the bottom and create a leaky installation. D. Place the 3107206 Air Box Kit inside the RV. This box contains mounting hardware for the air conditioner and will be used inside the RV. See FIG. 7. FIG. 9 MEASURE CEILING THICKNESS CENTER A /C FROM BEL OW GASKET PULL DOW N ELECTRICAL CORD 6

D. Measure (See FIG. 9) the ceiling to roof thickness: 1. If distance is 1"-2", remove perforated tabs from both upper and lower ducts. 2. If distance is 2"-3", remove perforated tabs from bottom duct only. 3. If distance is 3"-4", install ducts as received. 4. If distance is 4"- 6", use optional duct adaptor, Part No. 3106775.004 and Bolt Kit, Part No. 3100895.006. E. Install ceiling template by sliding lower duct over upper duct. F. Start each mounting bolt by hand before tightening any of them. The four (4) threaded inserts in the base pan can be seen to aid in starting the bolts. EVENLY TIGHTEN MOUNTING BOLTS TO A TORQUE OF 40 TO 50 INCH POUNDS. This will compress the roof gasket to approximately 1/2". The bolts are self locking so over tightening is not necessary. If bolts are left loose there may not be an adequate roof seal or if overtightened, damage may occur to the air conditioner base or ceiling template. Tighten to torque specifications listed in this manual. 6. WIRING OF SYSTEM Note: All wiring must comply with the National Electrical Code and any State or Local Codes or regulations. C. Connect black wire in junction box to black or hot wire from supply line. D. Connect supply ground wire to identified ground screw in junction box. E. Install junction box cover with two (2) blunt point screws (C). F. Plug unit electrical cord into the mating connector on control box. FIG. 10 7. INSTALL AIR BOX FIG. 11! WARNING Disconnect 115 volt AC. Failure to follow these instructions could create a shock hazard causing death or severe personal injury.! WARNING This product is equipped with a 3-wire (grounded) system for protection against shock hazard. Make sure that the appliance is wired into a properly grounded 115 volt AC circuit and the polarity is correct. Failure to do so could result in death, personal injury or damage to the equipment. (Steps A. - F refer to FIG. 10.) A. Route supply line into junction box through provided Romex Connector (D). Six (6) inch leads are sufficient for connection to unit wires and ground screws. B. Connect white wire in junction box to white or neutral wire from supply line. A. Remove return air grille from air box by pulling in on halfround finger catches. Note: If optional heat package is to be installed, do so at this time, before the air box is installed. Follow instructions with heat package for its installation procedure. 7

B. Hold air box up to ceiling template and install three (3) #10 x 3/8" screws at air box mounting point. See FIG. 12. C. Snap hole plug (E) into place at rear of air box. D. Install four (4) wood screws (B) that hold air box tight to ceiling if so desired. E. Reinstall return air grille and filter into air box. F. The air conditioner installation is now complete. Turn on power to the unit for operational check. Please read Unit Operating Instructions before proceeding. FIG. 12 8. INSTALLATION ON TENT CAMPER ROOF A. The permanent wiring leading to unit junction box may originate in a flanged surface inlet located in roof section near the side wall. See FIG. 13. B. A unique outlet receptacle for air conditioner should be located in the side wall of vehicle beneath the flanged surface inlet. C. A cord set fabricated from an oil, water, and ozone resistant material, such as Type SJOW-A, shall be used to connect the flanged surface inlet and the air conditioning receptacle. This cord set shall be visible during use and shall not be installed in raceways or placed behind walls or cabinet panels. FIG. 13 AIR CONDIT IONER AIR BOX PERMANENT WIRING IN ROOF OR RACEWAY CORD SET (Type SJOW -A or Equivalent, Must be V isible) UNIQUE P LUG JUNCTION BOX UNIQUE RECEPTACLE SO N O O THER PLUG M AY B E PUT I NTO T HIS CIRCUIT OPERATING INSTRUCTIONS OPT. HEAT OFF FAN LOW by Dometic COOL LOW MED MED HIGH HIGH COLDER 1. CONTROLS: A. The Selector Switch has eight positions including "OFF". This controls fan speed, heating mode, and cooling modes. B. The Thermostat controls the temperature range from 65 o F on the coldest side to 90 o F on the warmest side. In the cooling mode, the compressor ON/OFF controlled by the thermostat setting. 2. COOLING OPERATION: A. Set the thermostat at the desired temperature level. B. Select the fan speed that best satisfies your needs: a. HIGH COOL: Selected when maximum cooling and dehumidification required. b. MED. COOL: Selected when normal or average cooling required. c. LOW COOL: Selected when room at desired comfort level and needs to be maintained. Normally this speed used for night time operation. 8

Note: The blower runs continuously to circulate air and maintain an even temperature. The compressor will come on as cooling is required to maintain the selected temperature level. 3. HEATING OPERATION: (With Optional Heat Kit Installed) Note: This electric heater will not replace a furnace for heating your RV in cold weather. The intent is to remove the chill on cool days or mornings. A. Turn the selector switch to "OPT. HEAT". B. The Heater will come on and begin heating. C. When desired temperature level in RV is reached, move the selector switch to off position or fan position. Note: Thermostat does not control heater ON/OFF cycle. 4. FAN OPERATION: This will circulate the air in your RV without cooling or heating. There are three positions: HIGH FAN, MED. FAN or LOW FAN to select from, depending upon personal choice. 5. "OFF" POSITION: This is to turn Unit off. 1. AIR FILTER: Periodically remove the return air filter located above the removable panel in the air box. Wash the filter with soap and warm water, let dry and then reinstall. Note: Never run the air conditioner without return air filter in place. This may plug the unit evaporator coil with dirt and may substantially affect the performance of the unit. 2. AIR BOX HOUSING: Clean air box housing and control panel with a soft cloth dampened with a mild detergent. Never use furniture polish or scouring powders. MAINTENANCE SERVICE - Unit Does Not Operate 1. If RV connected to motor generator, check to be sure motor generator is running and producing power. 2. If RV connected to power supply by a land line, check to be sure line is sized properly to run air conditioner load and it is plugged into power supply. 3. Check your fuse or circuit breaker to see if it is open. 4. After the above checks, call your local service center for 3. FAN MOTOR: Factory lubricated and requires no service under normal use. 4. FROST FORMATION ON COOLING COIL: Under certain conditions, frost may form on the evaporator coil. If this should occur, inspect the filter and clean if dirty. Make sure air louvers are not obstructed. Air conditioners have a greater tendency to frost when the outside temperature is relatively low. This may be prevented by adjusting the thermostat control knob to a warmer setting (counter clockwise). Should frosting continue, operate on LOW, MED. or HIGH FAN setting until the cooling coil is free of frost. If your unit fails to operate or operated improperly, check the following before calling your service center. further help. This unit must serviced by qualified service personnel only. When calling for service, always give the air conditioner Model Number and Serial Number. This information can be found on unit rating plate located on the base pan near the return air opening. Return air grille must be removed from air box to view. 9

MOUNTING PARTS AIR CONDITIONING UNIT A. (4) 1/4" #20 x 7" bolts Discharge Air Mounting Bolt B. (4) #8 x 5/8" long sharp point wood screws C. (7) #10 x 3/8" blunt point tapping screws D. (1) Romex connector Threaded Hole In Bottom Mounting Bolt Upper Discharge Duct Return Air Power Supply Line Framing Stock E. (1) Hole Plug Discharge Air Duct Discharge Air Discharge Air AIR BOX - CONTROLS WIRING DIAGRAM AIR CONDITIONER - WIRING DIAGRAM GRN/YEL MOTOR COMPRESSOR C R O.L. S * PASSED DIELECTRIC 6 PIN CONN WHT BLU 1 BRN WHT BLK 2 YEL 3 FAN RED 4 C WHT 5 HERM RUN CAP RED WHT COMP STARTER START CAP PTCR * RED GRN/YEL 6 * NOT USED ON SOME MODELS 3105052.033 10