Fault Codes. J control

Similar documents
LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

No Operation of air conditioner Explanation

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

PART7. Trouble Shooting

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Compact Wall Mounted Wall Mounted / Floor Compact Cassette / Slim Duct INVERTER MULTI

Driftsinstruks. Utopia kontroller feilkoder PCP-2HTE og PC-ART. Vi håper de får stor glede av et Novema kulde produkt!

QUARTZ INVERTER TROUBLESHOOTING GUIDE

A/C SYSTEM GENERAL DIAGNOSTIC PROCEDURES

DUCT type. SPLIT TYPE AIR CONDITIONER (50Hz) Models Indoor unit Outdoor unit C O N T E N T S

LIGHT COMMERCIAL. Troublesooting

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

Heat Recovery Ventilation

KMIR. Multi outdoor units. troubleshooting Multi zone CONDENSING UNITS MKMIR218-H221, KMIR327-H217, KMIR436-H217, KMIR545-H219.

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

SPLIT TYPE ROOM AIR CONDITIONER FLOOR TYPE

3. SERVICE TOOLS Inverter checker RSUK09-17 CLIMATE COMFORT. All Seasons. Heating. Air Conditioning. Applied Systems.

6. Troubleshooting. 6-1 Basic items for trouble shooting. Samsung Electronics 17

12. Troubleshooting Items to be checked first. Samsung Electronics

4.Failure phenomenon. Mirage comes out from indoor. When the cold air from AC cools the indoor air. unit

5. TROUBLE DIAGNOSIS

Fault Code Check List

LUV INVERTER SERIES. Self-diagnostics and Trouble-shooting. Part 2 of 2 42/38LUV028H 42/38LUV035H 42/38LUV052H 42/38LUV065H 42/38LUV070H 42/38LUV080H

EcoNet and Flash Codes

PANASONIC FAULT CODE GUIDE. ECOi ECO-G - PACi

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

DIAGNOSIS SYSTEM DESCRIPTION CHECK ENGINE WARNING LIGHT CHECK

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

OUTDOOR UNIT CONTROLLER (OUC)

D M S 760 C01 A A 1 1

3.3 Air Conditioning (A/C) Model 202

SECTION Climate Control System - General Information

A/C SYSTEM SPECIFICATIONS

Power Sliding Door (PSD) Diagnostic Approach. Fixing Intermittent Malfunctions. Power Sliding Door (PSD) Diagnostic Information

EG1 189 EFI SYSTEM 5S FE ENGINE DIAGNOSIS SYSTEM

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER ASY9USBCW AOY9UGBC ASY12USBCW AOY12UGBC. Models Indoor unit Outdoor unit


Electronic Refrigerator Diagnostics

Special Tool Required: MPCS Service Connector 07WAZ A

3.2 Air Conditioning (A/C) Model 140 up to M.Y. 1995

DESCRIPTION AND OPERATION

HEATER & AIR CONDITIONING CONTROL SYSTEM

01 02B ON-BOARD DIAGNOSTIC [ENGINE CONTROL SYSTEM (FS)]

Trouble Shooting. Symptom Possible Cause Solution Power switch ON but switch Light is Off. Main power to unit Off. Switch light defective.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

1996 AUTOMATIC A/C-HEATER SYSTEMS Acura Automatic A/C Systems

A/C-HEATER SYSTEM - AUTOMATIC

SERVICE Manual AIR CONDITIONER OUTDOOR UNIT UM27B1C3 INDOOR UNIT AM27B1C07 AM27B1C Installation. 2. Disassembly and Reassembly

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Technical Information and Diagnostic Guide RestStar Use this guide with 5700XE RestStar Unit. Western Star 5700XE.

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTZ0036B-SF-1B. ComfortLink II System Cooling 4TTZ0036B1000A CAUTION

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

ASU18RLB ASU24RLB AOU18RLB AOU24RLB SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE CONTENTS

ENGINE 01 02A 1. Toc of SCT ON-BOARD DIAGNOSTIC [ENGINE. Toc of SCT 01 02A ON-BOARD DIAGNOSTIC [ENGINE CONTROL SYSTEM (ZM)] 01 02A

Application Engineering

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

technical data air conditioning systems MXS-B Multi Application Split Sky Air

HWP Protection Board

TECHNICAL HANDBOOK. for MULTISPLIT NETWORK SYSTEMS OR GROUP CONTROL

SRS AIRBAG CONTROL SYSTEM

9. Maintenance. 9.1 Precautions before Maintenance. Service Manual. electrolytic capacitor after power off. maintenance safely.

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

Application Engineering

DIAGNOSIS AND TESTING

DIAGNOSIS SYSTEM DESCRIPTION EG2 170

DTC P1655 Evaporative Emission (EVAP) Purge Solenoid Control Circuit

RAC Product Trouble Shooting Guide

Modulating Furnace Information. Warning on Meter Setting - Read First!

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

G - TESTS W/CODES - 2.2L

ZONE CONTROLLER Air Conditioners

Third Generation NITE Phoenix

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components


AIR CONDITIONER 4 WAY CASSETTE SERIES. 1. Precautions. 2. Product Specifications. 3. Disassembly and Reassembly. 4. Troubleshooting. 5.

3.10 Air Conditioning (A/C) Contents

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

CEILING WALL type INVERTER

SUPPLEMENTAL RESTRAINTS SYSTEM

HAN-L62 MOUNTING PLATE


Multi V Air Conditioner SVC MANUAL(Exploded View)

SRS AIRBAG CONTROL SYSTEM

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

SERVICE MANUAL OUTDOOR UNIT. No. OB387

DIAGNOSIS SYSTEM DESCRIPTION


Troubleshooting Guide

ANTI-LOCK BRAKE SYSTEM

DIAGNOSIS AND TESTING

Transcription:

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 Enter unit inspection mode by pushing the UP and DOWN buttons simultaneously for two seconds. Ensure that the TEMP lamp is on. The inspection lamp - 19 will light in GREEN. A fault indicator lamp - 24 to 30 will light. 19 Inspection Mode 13/04/2012 1

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 2 ERROR Transmission error in twin control CAUSE Mis-wiring between Master and Slave units Poor connector contact MEASURES Check dip-switch setting Check interconnecting wiring

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 3 TROUBLE POINT Outdoor Unit CAUSE Mis-wiring between Indoor and Outdoor Outdoor protection functioned Malfunction of piping sensor Reverse phase detected MEASURES Check wiring Check outdoor unit protection device Check piping sensor

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 4 TROUBLE POINT Intake sensor - TH5 CAUSE Poor connector contact Thermistor malfunction MEASURES Check connector Check thermistor

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 5 TROUBLE POINT Piping sensor - TH2 CAUSE Poor connector contact Thermistor malfunction MEASURES Check connector Check thermistor

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 6 TROUBLE POINT Drain sensor - D5 CAUSE Poor connector contact Thermistor malfunction MEASURES Check connector Check thermistor

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 7 TROUBLE POINT Drain overflow protector CAUSE Drain lift up mechanism malfunction Drain sensor mounting incorrect MEASURES Check drain sensor Check drain pump

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 19 Inspection Mode 13/04/2012 8 TROUBLE POINT Frost protector CAUSE Short cycling in air passage Shortage of refrigerant Air filter clogged Faulty fan motor MEASURES Check for blockages / dirty filters Check refrigerant charge Check operation of Indoor Fan Motor

J control Timer Temp Fault Codes 12 11 10 9 8 7 6 5 4 3 2 1 30 29 28 27 26 25 24 23 22 21 20 To exit diagnostic mode turn controller OFF and ON. NOTE: The Remote Controller will memorise the last fault even when the breaker has been switched off. To clear the memory, press the UP and DOWN buttons for two seconds 19 Inspection Mode 13/04/2012 9

13/04/2012 10 J control RC Diagnostics CHECK MODE VANE T RUN 00 POWER ON/OFF HR Mitsubishi Electric 25 C Turn on the main power of the unit. Turn the switch on the back of the Remote Controller from NRM to SET CHECK and TEST RUN will start flashing Press the HR button. OO will start flashing

13/04/2012 11 J control RC Diagnostics CHECK MODE VANE T RUN POWER ON/OFF HR Mitsubishi Electric 25 C Point the controller at the 00 Indoor Unit and press the HR button again An intermittent buzzer will sound A one-second blip will then sound The amount of blips indicates the fault

13/04/2012 12 J control RC Diagnostics CHECK T RUN 25 C 1 Irregular intake sensor 00 POWER ON/OFF MODE VANE HR Mitsubishi Electric 2 Irregular piping sensor 4 Irregular drain sensor 5 Irregular drain pump 6 Frost protection 8 Outdoor Unit fault 9 No fault

13/04/2012 13 J control RC Diagnostics CHECK T RUN 25 C 00 POWER ON/OFF Push the POWER ON/OFF button to exit fault diagnosis mode MODE VANE HR Return the switch on back of controller to NRM Mitsubishi Electric

P1 Fault Diagnostics Abnormality of Return Air Sensor - Short or Open Circuit Run system in Test Run. This will bypass all thermistors Check thermistor is positioned correctly. NO Replace in holder Remove thermistor from PCB and check resistance. 6.4k at 20 C (Room Temp). NO Replace thermistor YES Replace Indoor PCB. 13/04/2012 14

P2 Fault Diagnostics Abnormality of Indoor Coil Sensor - Short or Open Circuit Run system in Test Run. This will bypass all thermistors Check thermistor is positioned correctly. NO Replace in holder Remove thermistor from PCB and check resistance. 6.4k at 20 C (Room Temp). NO Replace thermistor YES Replace Indoor PCB. 13/04/2012 15

P4 Fault Diagnostics Abnormality of Drain Sensor - Short or Open Circuit Run system in Test Run. This will bypass all thermistors Check thermistor is positioned correctly. NO Replace in holder Remove thermistor from PCB and check resistance. 6.4k at 20 C (Room Temp). NO Replace thermistor YES Replace Indoor PCB. 13/04/2012 16

13/04/2012 17 P5 Fault Diagnostics Malfunction of Drain Sensor and / or Drain Pump Check drain fall / rise. Rise must not exceed 500mm. Measure resistance of drain sensor heater. Remove from PCB and test for 82. NO Replace Drain Sensor / Heater Is there 240 volts at PCB on Drain Pump connector CNP YES NO Replace Drain Sensor / Heater Replace Indoor PCB.

P6 Fault Diagnostics Coil Frost Prevention / Short Cycling Remove thermistor from PCB and check resistance. 6.4k at 20 C (Room Temp). Check for dryer or sight glass Check for Short Cycling of air around evaporator NO YES YES Replace Thermistor Remove component as is expansion line and may be the cause of previous overcharging Correct Air Flow Check for Dirty Filter, obstructions at Outdoor Unit or damaged fan motor 13/04/2012 18 If NO to any of these then the system is likely to have an incorrect refrigerant charge.

13/04/2012 19 P7 Fault Diagnostics System Addressing Error Error on dipswitch setting of Indoor Unit or Remote Controller. Check SW2 and SW6 setting. SW2 - Group Control. SW6 - Twin/Triple Split NO Check SW17 1-6 on RC. These should be OFF unless controlled from third party. NO Malfunction of the transmitting receiving circuit. The Remote Controller power supply is faulty Check for 12 volts DC at terminals of Remote Controller. Try with different controller! Replace Indoor Controller Board

13/04/2012 20 Fault Codes - P8 Explanation of system logic The Indoor Unit will detect an abnormality in the Outdoor Unit when the difference in temperature between the coil sensor and the return air sensor does not exceed 5 C after a running period of eight minutes. Further interrogation of the Outdoor Unit When The Indoor Unit detects a fault at the Outdoor Unit P8 will flash on the Remote Controller. The Outdoor Unit LED diagnostics need to be interrogated. Blinking LED - Fault Static LED - Output state

13/04/2012 21 Fault Codes To erase Fault Codes from the RC Press Test Run twice Press Check twice RC will the display factory setting U8 This will not erase memory from the Outdoor Unit

13/04/2012 22 LED Diagnostics SW1 Erase past check code contents SW2 Display existing / last reported check code contents

LED Diagnostics SW2 SW2 With SW3-1+2 off will alternate between fault and operation status output With SW3-1 off +2 on will initiate compulsory defrost ON OFF SW3 13/04/2012 23

13/04/2012 24 LED 1 Diagnostics Reverse Phase Protection Activated Check Phase of power supply Exchange any two of the Red, Yellow and Blue phases Check RST Plugs.

13/04/2012 25 RST Plugs PCB R S T A1 A2 A3 N The RST Plugs check the incoming phase rotation and also check for missing phases.

LED 2 Diagnostics Open Phase Detected Check for 415 volts between Red, Yellow and Blue Phases OK Protector may be open circuit when power switched on Check for 240 volts between each Phase and Neutral NO Check the following for Open Circuit. 63H1 (HP Control) 63H2 (HP Protect) 26C (Thermal Switch) Reconnect missing phase. Check fuses, wiring etc. 13/04/2012 26 Check RST Plugs.

13/04/2012 27 LED 3 Diagnostics Pipe sensor short or open circuit Check for poor contact or disconnected sensor plug. NO Check plug and contact on PCB. (CN2) Measure resistance of pipe thermistor. NO Replace thermistor Replace PCB

LED 4 Diagnostics High Pressure Switch Fault Check with HP Gauge. Does this read over 300 psi? NO YES Check to see if 63H2 Plug is connected. This should only be connected if the compressor is a Copeland. Check connection of 63H2 Check for open circuit of 63H2 Fan Motor runs fast Check Airflow of Condenser and clean coils if required Link pins on CN22 at Outdoor to run fans at full speed Replace Motor Fan Motor runs slow Check resistance of thermistor Replace HP Switch 13/04/2012 28 Replace PCB

13/04/2012 29 Thermistor Readings Actual temp Resistance Actual temp Resistance Actual temp Resistance 1 14.32 16 7.41 31 4.09 2 13.67 17 7.10 32 3.94 3 13.06 18 6.82 33 3.79 4 12.48 19 6.54 34 3.66 5 11.93 20 6.28 35 3.52 6 11.40 21 6.03 36 3.40 7 10.91 22 5.80 37 3.28 8 10.43 23 5.57 38 3.16 9 9.99 24 5.35 39 3.05 10 9.56 25 5.15 40 2.94 11 9.16 26 4.95 41 2.84 12 8.77 27 4.76 42 2.74 13 8.40 28 4.58 43 2.65 14 8.05 29 4.41 44 2.56 15 7.72 30 4.25 45 2.47

Refrigerant Charge Models PUH 1.6 VKA (uk) PUH 2 VKA (uk) PUH 2.5 VKA (uk) PUH 3 VKA (uk) PUH 3 YKA (uk) PUH 4 YKSA (uk) PUH 5 YKSA (uk) PUH 6 YKSA (uk) 30m 35m 40m 45m 50m 2.2 2.3 2.4 2.2 2.3 2.4 2.8 2.9 3.0 3.1 3.3 3.2 3.3 3.4 3.6 3.7 3.2 3.3 3.4 3.6 3.7 4.2 4.4 4.5 4.6 4.8 5.4 5.6 5.7 5.9 6.0 5.0 5.2 5.3 5.5 5.6 Refrigerant charge (Heat Pump) - all units pre charged to 30 m 13/04/2012 30

13/04/2012 31 Service notes P5 500mm Max Lift 150mm Max

13/04/2012 32 Service notes OC OC OC OC 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 IC 1 2 3 IC 1 2 3 IC 1 2 3 IC P8

13/04/2012 33 Service notes OC OC OC OC 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 IC 1 2 3 IC 1 2 3 IC 1 2 3 IC P8 P8