In-line Plug-in Design 3NJ6

Similar documents
Circuit-Breaker Design

Withdrawable Unit Design - Motor Feeders and Outgoing Cable Feeders

Adak Behin Niroo. co.com

General. SIVACON for all Applications in Low-Voltage Network 1/2. Type-tested main distribution board SIVACON 8PT 1/3 with busbars rear

BETA Switching Switches and Light Indicators

The low-voltage power distribution board that sets new standards

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

The low-voltage power distribution board that sets new standards

SIVACON S4 Power Distribution Boards

e n e r g i a HULANICKI BEDNAREK sp. z o.o. HABeR-M Switchgear system rated up to 1600A 1

BETA Fuses and Fuse Systems

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

SENTRON Switching and Protection Devices Switch Disconnectors

Switchboards, Distribution Systems and Cabinet Systems

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

Ground-Breaking Power Distribution Boards up to 4000 A

3NP1 Fuse Switch Disconnectors up to 630 A

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

GE Industrial Solutions Power Protection. LV Switchgear SEN Plus

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

SIVACON Power Distribution Boards, Busway Systems and Cubicle Systems

PANEL PANEL MOUNTING COMPONENTS

3/2 Introduction. Unequipped Distribution Boards (Flat Pack) 3/6 8GK1 surface-mounting distribution boards

Siemens AG WT Air Circuit Breakers up to 4000 A. Catalog LV SENTRON. Answers for infrastructure.

SIVACON The Versatile Low-Voltage Switchboard

Customized for maximum demands. SIVACON Technology Partner. SIVACON S8 low-voltage power distribution board: safe, flexible, efficient

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Special Purpose Fuses

Persian Tajhiz Niroo Engineering Co.

E-12 Low-voltage Switchboard

Gas Insulated Metal-clad Switchgear, HMGS!

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

INNOZED D0 fuse-bases with touch protection

Vertical fuse disconnects

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

TriLine PowerModules Overview with Planing Examples

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

Molded-Plastic Distribution Systems

4/ Kabeldon fusegear and cable distribution cabinets Pre-assembled distribution boards

Persian Tajhiz Niroo Engineering Co.

Switchgear Type 8DJH 36 for Secondary

Safe, flexible and cost-efficient power distribution

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

LINOCUR Size D02 63A 230VAC/440VAC

with Vacuum Circuit Breaker HAF

PIX-H Metal-clad switchgear up to 17.5kV

UniGear. Technical Guide

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

60mm-System classic 630A (800A) / 2500A

Original Manual 2CCC444010M0201 Rev. 1.0, Date of Release: 02/2016. Remote Power Panel Assembly instructions

ype UP T Busplugs Low Voltage Switchboard Equipment

Technical System Catalogue Ri4Power

Contents. We build a better future! MCC HCB

Air-insulated switchgear UniGear type ZS1

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Service Entrance Methods

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Vertical fuse disconnects

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Unified requirements for systems with voltages above 1 kv up to 15 kv

Air Circuit Breakers

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

E-12 Low-voltage Switchboard

BETA Low-Voltage Circuit Protection

System Benefits Should you have any further questions, please contact our UL hotline at: +49 (0)9563/ Connection Technology EQUES Technology

Air Circuit Breakers

Busway Construction. Bus Bars

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Load and Motor Switches, Load-Break Switches Series 8549

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

8WH2 Spring-Loaded Terminals

MOULDED CASE CIRCUIT BREAKERS BC160N

TRANSMISSION SYSTEMS

MULTIVERT 250A Size 1, 690VAC

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

mainly used for power distribution

MANUAL 2018 AL 2018 U AN M

Steve Summers Region Sales Manager

Jtec 10kA Miniature Circuit Breaker

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

3VT5 Molded Case Circuit Breakers up to 1600 A

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

ENYSTAR Load Centers up to 250 A

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

MCCB Plug-in Chassis Type HBC

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

9/16/2010. Chapter , The McGraw-Hill Companies, Inc. TRANSMISSION SYSTEMS. 2010, The McGraw-Hill Companies, Inc.

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

GHA. Gas-Insulated Switchgear. Gas-Insulated Switchgear. Switchgear extension and replacement of a panel

CPG.0 Single busbar gas-insulated cubicles

Transcription:

Contents Page - Outgoing Feeders General 6/2 Structure and Functions inclusive Forms of Internal Separation, Installation of Instruments 6/2 Plug-on Bus System 6/2 Cable Connection Compartment 6/2 Switch-disconnector-fuse 3NJ6 6/2 Rated s 6/3 Installation Data 6/3 Project Planning Rules 6/3 Siemens SIVACON 8PT 12/2003 6/1

8PT2755 General In-line-type switching devices with supply-side plug-in contact offer an alternative to the withdrawable unit design. With their modular design, they enable easy and quick conversion or replacement under operating conditions. Structure and Function The switching device compartment has a height of 1700 mm and is intended to accommodate plug-in modules with a 185 mm phase spacing. The cable connection compartment is located on the right. Cable connection right-hand side Plug-on Bus System (3 and 4 pole) The plug-on bus system with the phase conductors L1, L2, L3 is located on the rear of the cubicle. The IP 20 degree of protection is achieved by the optional shock hazard protection with tap openings and it enables to replace the plug-in modules under operating conditions. Rated s of Plug-on bus system Crosssection Rated I n depending on ambient temperature [A] ventilated 20 25 30 35 40 45 50 80x10 2260 2210 2155 2100 2045 1985 1925 Short-circuit strength I pk = 110 ka I cw = 50 ka, 1 s 1000/1200 up to 630 A OFPD Form 1 Form 3b Form 4b IP 41 ventilated PE, PEN and N conductor bars are installed in the cable connection compartment. With 4-pole network systems the N conductor is assigned to the phase conductors L1, L2, L3. PE cross-section PEN, N cross-section 1x40x5 1x40x10 or 2x40x10 Cable Connection Compartment Cable connection possibilities Plug-in module type Rated max. number and crosssections of connected cables (3 ½-conductors) [mm²] [A] 3NJ6110 160 1 x 95 3NJ6120 250 1 x 240 3NJ6140 400 2 x 240 3NJ6160 630 2 x 240 Switch-disconnector fuses 3NJ61 In-line type switching devices for outgoing feeders up to 630 A available in the following designs: Fuse module with fuses Switch-disconnector-fuse (single-break) Switch-disconnector-fuse (double-break) in each of the above cases with or without electronic fuse monitoring Switch-disconnector without fuses Device compartment (200 mm to 400 mm high) for auxiliary devices and instruments consisting of: Door Mounting plate With and without 400 A connection module on plug-on bus system Available device installation depth 180 mm Rated s of switch-disconnector fuses 3NJ6 3NJ61 Rated Rated I n depending on ambient temperature [A] ventilated Typ [A] 20 25 30 35 40 45 50 3NJ6110 160 137 134 130 125 120 112 106 3NJ6120 250 220 215 210 200 190 180 170 3NJ6140 400 350 340 330 320 305 290 270 3NJ6160 630 550 535 520 500 475 450 425 Installation of Instruments 1 = Measuring instrument 48 x 48 mm 1 The plug-in modules enable to accommodate a measuring instrument 48 x 48 mm with 1-pole measuring. With 3-pole measuring the measuring instruments can be mounted into additional switching device compartment doors or into the cable compartment door. The belonging transformers are installed on load side. a) b) c) a) Switch-disconnector-fuse with fuse element featuring independent manually-actuated spring operating mechanism for LV HRC fuses (DIN), in sizes 00, 1, 2 and 3 b) Same as a), but with interruption on both sides of the fuses c) Switch-disconnector with independent manually-actuated spring operating mechanism (same sizes as a) 6/2 Siemens SIVACON 8PT 12/2003

Installation data of switch-disconnector-fuse modules 3NJ61 3NJ61 Type Rated [A] Size Height requirements of modules [mm] 3 pole/4 pole Max. quantity per cubicle pieces 3 pole/4 pole 3NJ6110 160 00 50 100 34 17 3NJ6120 250 1 100 150 17 11 3NJ6140 400 2 200 250 8 6 3NJ6160 630 3 200 250 8 6 Further installations Designation Height requirement Blanking covers for empty 50 mm compartments/connection module Device compartment 200 mm * Device compartment 300 mm * Device compartment 400 mm * 400 A connection module for device compartment + 50 mm alarm indicator 1-35 plug-in modules (AC) -- alarm indicator 1-50 plug-in modules (DC) -- *) max. useful device installation depth 180 mm Rated Currents Rated s of device sizes = 0,8 x I N of the largest fuse link for total of all feeders in the cubicles 2000 A Size 00 Size 1 Size 2 50 mm high 100 mm high 200 mm high 200 mm high I N = 160 A Rated Fuse Rated Fuse Rated Fuse Rated Fuse = 125 A I N = 250 A = 200 A I N = 400 A = 320 A I N = 630 A = 500 A Rated s of small fuse links of one size = 0,8 x I N of the fuse link Size 00 Continuous Size 1 Continuous Size 2 Continuous e.g. e.g. e.g. e.g. Fuse Fuse Fuse Fuse Continuous I N = 125 A x 0,8 =100 A I N = 224 A = 180 A I N = 355 A = 284 A I N = 500 A = 400 A I N = 80 A x 0,8 = 64 A I N = 125 A = 100 A I N = 315 A = 250 A I N = 400 A = 320 A Project Planning Rules Project planning rule for ventilated cubicles with plug-in modules 3NJ6: The diversity factor detailed in IEC 60439-1 applies to the completely assembled cubicle. If these notes are not observed, premature aging of fuses and uncontrolled release may occur as the result of local overheating. All data refers to ambient temperatures of the switchboard amounting to 35 C on the 24 h average. Conversion factors for other ambient temperatures: Ambient temperature of the system [ C] 20 25 30 35 40 45 50 55 Conversion factor 1,1 1,07 1,04 1,00 0,95 0,9 0,85 0,8 Siemens SIVACON 8PT 12/2003 6/3

8PT2755 Rated of fuse links: Plug-in module arrangement: Blanking covers with ventilation slots 50 mm high Total of all feeders in the cubicle 2000 A exceptions: Total of all feeders in the cubicle 1500 A Plug-in modules Size 2 Permissible ( at 35 C system ambient temperature) 0.8 x I N of the fuse Sizes 00 to 2 0.90 x I N 0.85 x I N formation is no longer permitted here. A 50 mm high blanking cover must assigned to each size 00 and 1 device. Installed in the cubicle from bottom to top, descending from size 3 to size 00 In the case of > 280 A > 440 A If possible, distribute plug-in modules over various cubicles. Total covered height to be assigned (see right-hand side for recommended arrangement of blanking covers) Arrangement of plug-in modules + belonging blanking covers Plug-in modules size 3 (group formation not permitted) 440 A to 500 A 200 mm = 4 pieces per plug-in module I N = 630 A I N x 0.8 = 500 A < 440 A 150 mm = 3 pieces per plug-in module i.e. I N = 500 A I N x 0.8 = 400 A Plug-in modules size 2 (group formation not permitted) 320 A 50 mm = 1 pieces per plug-in module i.e. I N = 355 A I N x 0.8 = 284 A s of plug-in modules Sizes 00 and 1 = Total of the fuse links x 0.8 100 mm = 2 pieces per group I N = 80 A Total I N x 0.8 IN = 125 A < 400 A I N = 125 A IN = 160 A s of unlimited size with plug-in modules size 00 64 A 100 mm = 2 pieces per group In combination with sizes 2 and 3 in one cubicle, the Size 2 rated s = 280 A and = 440 A. Blanking covers must be assigned to devices belonging to Sizes 2 and 3 (see above). n I N = 16 80 A n-1 I N = 125 20 A 2 I N = 63 A 1 I N = 80 A (Total 1 to n I N ) x α α = rated load factor n = 4 and 5 α = 0,8 n = 6 to 9 α = 0,7 n 10 α = 0,6 6/4 Siemens SIVACON 8PT 12/2003

Allocation of blanking covers with ventilation slots, 50 mm high: Size 00 Total of group 500 A Size 1 Total of group = 500 A Single device Size 2 of each 320 A Single device of each 440 A I N = 80 A Total Fuse Total e.g. e.g. I N = 125 A of group I N = 250 A of group Fuse 0.8 x I N Fuse 0.8 x I N I N = 125 A 490 A x 0,8 Fuse 500 A x 0,8 = I N = 355 A = 280 A I N = 500 A = 400 A I N = 160 A = 392 A I N = 250 A 400 A 2 blanking 2 blanking 1 blanking 3 blanking covers/group covers/group cover/device covers/device 440 A > I Size 500 A 00 and 1 e.g. Fuse 0.8 x I N I N = 40 A Total I N = 630 A = 500 A I N = 100 A of group I N = 100 A 490 A x 0,8 = 4 blanking Fuse 392 A covers/device I N = 250 A 2 blanking covers/group Size 00 Size 00 with I N 80 A of the 64 A Any group size, up to 33 plug-in modules/cubicle Example: Size 00 and Size 2 and 3 For combinations of Size 00 with I N 80 A with other sizes, in the cases of sizes 2 to 3 the rated s must be reduced to 0.7 x I N : I N = 20 A 16 A I N = 20 A I N = 32 A 26 A I N = 32 A I N = 32 A 26 A I N = 32 A I N = 40 A 32 A I N = 40 A I N = 40 A 32 A I N = 40 A I N = 50 A 40 A I N = 50 A I N = 50 A 40 A I N = 50 A 2 blanking covers/group Size 2 I N = 400 A The allocations of blanking covers for device sizes 1 to 3 must be observed (see adjacent example of an incomplete line-up of cubicle components)! Rated : 280 A I N = 630 A Rated : 440 A Siemens SIVACON 8PT 12/2003 6/5