INSTRUCTION SHEET. Network Operations Center (NOC) Interface Instruction

Similar documents
w w w. h d o n l i n e s h o p. d e CHROME FAN KIT GENERAL INSTALLATION -J04347 REV Kit Number Models Kit Contents

MF 9520 / 9540 / 9560, Challenger 540C / 560C

Wiper motor bolt and spacer. 3. Place relays as shown in picture so you can route the wires.

Wiring Harness Update Kit Assembly Instructions Treker 4200/4400 NT & ST Series Manual No M

Installation Manual for the Pantera Ignition Switch Bypass

Line Lock Package, Mustang GT/GT500, 2007 PACKING LIST

Owner's/Installation Manual

Rostselmash Torum 740

Quick Connection Panel (QCP) Installation Guide

This sheet must be read completely to:

Service Quantity Lev. 4 A For ECU Mounting 2 A FOR P-CLAMP

750 Paso Wiring Upgrade

Installation Instructions

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CR-TIE4, INTAKE SIDE STARTER 1 A 1 A

GENERAC PARTS MANUAL

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

TECHNICAL INSTRUCTIONS

IMPORTANT SAFEGUARDS

LED ROLLER LIGHTING. LED Components... 6

APS F-Body Twin Pump Fuel Supply System - APSGMF-FSS/01

An ISO 9001:2015 Registered Company

Installation Instructions

GENERAL SAFETY PRECAUTIONS

Installation Instructions

MOTOALLIANCE WINCH MOUNT

29048, 29049, 29050, 29051, 29052, 29053, 29054,

INSTALLATION FORK MOUNTED DRIVING LIGHTS 5008

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

MODEL ELC-12/40-CVM-D BATTERY CHARGER

w w w. h d o n l i n e s h o p. d e ELECTRA-GLO LIGHT BARS GENERAL INSTALLATION -J04723 REV Kit Number Models Kit Contents

2-row and All-row systems included.

196cc Gasoline Engine (G33)

w w w. h d o n l i n e s h o p. d e VRSC TURN SIGNAL RELOCATION KIT GENERAL INSTALLATION -J03341 REV Kit Number Models

29048, 29049, 29050, 29051, 29052, 20953, 29054,

Flow Sensor

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

CM52 Network Protector with Arc Flash Reduction Module

PROCEDURE STEPS: WARNING:

Inverting Fault Circuit Breaker Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives VAC and VAC

C TROUBLESHOOTING SIENNA (EWD613U) VOLTAGE CHECK CONTINUITY AND RESISTANCE CHECK

ROADMASTER, Inc NE 127th Ave. Vancouver, WA Fax roadmasterinc.com ROADMASTER, Inc.

TRAVEL'R DIRECT RESPONSE

Product Support Bulletin

I N S TA L L AT I O N

INSTALLATION INSTRUCTIONS FOR THE TOMAHAWK ELECTRIC REVERSE

Parts. WindyNation s 40 to 120 AMP Diversion Charge Controller Wiring Diagram (copyright 2009) 40 AMP Relay. Enclosure Charge Controller

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

w w w. h d o n l i n e s h o p. d e ROAD TECH QUEST GLOBAL POSITIONING SYSTEM (GPS) MOUNTING KIT GENERAL INSTALLATION -J03554 REV.

29048, 29049, 29050, 29051, 29052, 29053, 29054,

Instructions for 2-row monitoring only

Service Lev. Parts - - KEA KIT, WIRE HARNESS 03-CRS, EXHAUST SIDE STARTER 1 A 1 -- KEA INS WIRE HARNESS KIT INSTRUCTIONS

GTWY605 Fast Idle, Shift Interlock, I/O Chevy 610 Van - 6.0L and 6.6L Engines Contact InterMotive for additional vehicle applications.

ROAD TECH ZUMO GLOBAL POSITIONING SYSTEM (GPS) HANDLE- BAR MOUNT KIT

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

Instructions for 2-row monitoring only

MGB Alternator Conversion Installation Instructions For MGA & 1962 to 1967 MGB

!!!!! !!!!!!! !!!!! ! 16VAC input voltage, 13.5VDC output voltage BRANCHES COUNTRYWIDE

Service Quantity Lev. 2 A FOR P-CLAMP

w w w. h d o n l i n e s h o p. d e CRUISE CONTROL KIT GENERAL INSTALLATION -J04064 REV Kit Number Models Additional Parts Required

Instructions for Field Retrofit of a Model 98 Temperature Controller in place of a Model 85 Temperature Controller

REARSENTRY TM BASE KIT ROSTRA OBSTACLE SENSING SYSTEM CONTENTS

SP Switch Programmable Switch Panel Power System. Parts Included

Owner s Manual. For Automatic Transfer Switch. 100 Amp. Model Number RTG16EZA3 MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Model PRO 9246CH Installation Manual

w w w. h d o n l i n e s h o p. d e HEATED HAND GRIP KITS GENERAL REMOVAL -J02983 REV Kit Number Models Kit numbers Service Parts

PART NUMBER: H630SXC001. Kit Contents: A. Amplifier with Bracket (1) D. Badge (2) with push nuts (4)

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

ALTITUDE ARMS AND CANOPY

Custom Dynamics Spyder Stingerz Installation Instructions

8436, 8437, 8438, 8439, 8442, 27480, 27780, 28028, & ISOLATION MODULE ELECTRICAL SYSTEM

INSTRUCTION, GPT LOW VOLTAGE THERMAL SWITCH (LVTS) INSTALLATION KIT P/N

255 Liter/Hr, In Tank Fuel Pump For Chrysler Front Wheel Drive Vehicles Catalog # INSTALLATION INSTRUCTIONS

Quantity by Model an assembly listed above Early Models Late Models. Instruction Kit JD 9x00/9x

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

Owner s Manual. For Automatic Transfer Switch. PowerPact Home Standby Generator MODEL NUMBER: SERIAL NUMBER: DATE PURCHASED:

Switch and Fuse Installation... 1 Awning LED Layouts... 2 Small Box and Marquee LED Layouts... 2 Big Box LED Layouts... 3

TOYOTA HIGHLANDER w/smart Key TVIP V4 REMOTE ENGINE STARTER (RES) Part Number: PT

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

HIGH VOLTAGE DISABLING

INSTALLATION INSTRUCTIONS

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

INSTALLATION INSTRUCTIONS

Installation Instructions Electric Heaters 5 20 kw

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

Installation Instructions Electric Heaters 5 20 kw

2015 Ford F150 Front Bumper w/ LED

Installation Instructions

P3066 INSTALLATION MANUAL

REF QTY PART DESCRIPTION PART NUMBER

Lethal Performance Dual FPDM Harness Kit Installation

xtablet T7000 Vehicle Mount Kit

LPE C5 Battery Relocation Kit

7.3L Ford PowerStroke 1999 THROUGH 2003 Without a Mechanical Lift Pump

INSTALLATION INSTRUCTION

SMM601-B Surveillance Mode Module Chevy Tahoe SSV and PPV (U.S. Vehicle Only) 2017* Chevy Tahoe PPV Only (U.S.

LED Driving Light Set For 2014 & Newer Can-Am Spyder RT # CA006-RT

Guardian GRD501-AR Adapter Matrix

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

ME217PIB / ME503PIB SMART INTERLOCK TECHNOLOGY ACME ADAPTER INTERLOCK BRACKET INSTALLATION AND OPERATING INSTRUCTIONS

Guardian Personal Mobility Lift Interlock GRD701-AR ( Dodge Sprinter) Installation Instructions

Transcription:

INSTRUCTION SHEET Network Operations Center (NOC) Interface Instruction Model No. 006594-0* *Available as a kit prior to 2015. NOC Interface installed at factory beginning in 2015. DANGER Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. (000191) IMPORTANT: Follow all safety protocols and remove the unit from service as outlined in the Owner s Manual before initiating installation. Purpose This interface provides dry contacts for connecting up to 4 signals to a remote system. The NOC is designed to be mounted into either the Protector Series or CPL QT Gaseous models. Follow the appropriate installation instructions for the application. Signals are: Generator Running - Driven by the fuel line. This relay will be energized anytime the fuel signal is active. Generator Fail - Driven by the common alarm output. This relay will be energized anytime the common alarm output on the Protector Series or CPL QT controller is active. Low Fuel Level - Available on Protector Series Diesel units only. Driven by header J13 on the Protector Series controller. The controller will energize this relay when it identifies a low fuel level condition based on the analog fuel sender input. Utility Loss - Driven by the Utility sense connection at the customer connect terminal block. This relay will be energized when utility is available and will de-energize when utility is not available. NOTE: This means the Normally Open (NO) relay contacts will be closed when utility is present. Contents NOC Interface (0K5122) Contents Quantity Part Number Description Quantity Part Number Description 1 0H7270A Snap Track, 5 inch 1 097234F Plug, Amp mini-universal 6 pin Mate n Lok 1 0K4929 PCB Assembly 2 036933 Screw, PPHM #10-32 X 3/8 1 0K5123 Wire Harness, Protector Series 6 028739A Tie Wrap, 3.9 inch, black 1 0K5121 Wire Harness, CPL QT Series (if applicable) 1 0K5122 Instruction Sheet Instruction Sheet 1

Network Operations Center (NOC) Interface Instruction Model No. 006594-0* DANGER Automatic start-up. Disconnect utility power and render unit inoperable before working on unit. Failure to do so will result in death or serious injury. (000191) NOTE: Set the generator to the OFF mode, remove the 7.5 Amp fuse, disconnect the battery negative (-) black cable and turn off all power sources, including battery charger and Utility Sense, to the control panel before beginning installation. A B 000658 A Output Connections (Dry Relay Contacts) Connect to customer interface equipment B Input Connections Connect to the generator signals Relay contact ratings: Both the Normally Open and Normally Closed contacts are available for each relay. 1A maximum, 30 VAC/DC maximum Terminal block connection: Terminal blocks are suitable for 18 to 26AWG discreet wire or a standard spade lug Figure 1. NOC Interface PCB Assembly Procedure - Protector Models (if applicable) SNAP TRACK INSTALLATION 1. Identify the snap track mounting location as shown below. See Figure 2. NOTE: Verify there is adequate clearance behind the control panel before drilling. Re-route any wire harnesses that may become damaged during drilling and installation. 2 Instruction Sheet

Model No. 006594-0* Network Operations Center (NOC) Interface Instruction 2. Drill two 1/8 inch holes, in the panel, at the dimple locations. Locating dimples for the snap track have been added to the sheet metal beginning in the 4th quarter of 2013. If locating dimples are not available, hold the snap track in the area shown in Figure 2, and mark the hole locations in the center of each slot in the snap track. Set the snap track aside and drill two 1/8 inch holes in the panel at the marked location. 3. Mount the snap track to the generator panel using the two screws included. Tighten the screws until the back of the snap track is drawn flush with the generator panel. Do NOT use washers with the screws. This could raise the head of the screw and could cause the screw to contact the PCB assembly. 4. Snap the PCB into the snap track. Press the PCB firmly into the snap track until it locks into place. When fully inserted, the PCB will be held firmly in place and will NOT be able to slide up or down in the snap track. A B Protector Series A Snap Track Mounting Location B Relay Location C Ground Post Mounting Screw C 000659 Figure 2. Snap Track Mounting Location - C2 (Horizontal for C1) WIRING CONNECTIONS 5. Connect the spade terminal of Wire13, in the kit harness, into the #13 location of the terminal block on the PCB assembly (0K4929). 6. Connect the spade terminal of Wire 0 in the kit harness into the #0 location of the terminal block of the PCB assembly (0K4929). 7. Connect the spade terminal of Wire 14, in the kit harness, into the #14 location of the terminal block on the PCB assembly (0K4929). 8. Connect the spade terminal of Wire 209 to the 209 location of the terminal block on the PCB assembly (0K4929). 9. Connect the spade terminal of Wire 575 to the 575 location of the terminal block on the PCB assembly (0K4929). 10. Connect the N1 and N2 wires coming from the PCB assembly into the N1 and N2 terminals on the customer connect block. 11. Connect the green 12AWG ground wire soldered into the PCB assembly to the mounting screw on the ground post. See wire diagram. 12. Unplug and discard the 2 pin wire loop plugged into the common alarm relay connector. 13. Plug the 2 pin connector of the kit harness into the common alarm relay connector. 14. Disconnect the Wire 0 going to the relay. 15. Plug the male terminal of Wire 0 in the kit harness into the Wire 0 just disconnected from the relay. 16. Plug the female terminal of Wire 40, in the kit harness, into the original #0 location on the relay. 17. Disconnect Wire 13 going to the relay. Instruction Sheet 3

Network Operations Center (NOC) Interface Instruction Model No. 006594-0* 18. Plug the male terminal of Wire 13, in the kit harness, into Wire 13 just disconnected from the relay. 19. Plug the female terminal of Wire 13, in the kit harness, back into the original #13 location on the relay. 20. Disconnect Wire 14 going to the relay. 21. Plug the male terminal of Wire 14, in the kit harness, into the Wire 14 just disconnected from the relay. 22. Plug the female terminal of Wire 14, in the kit harness, into the original #14 location on the relay. 23. Wiring the low fuel signal wire. The low fuel signal (Wire 575) is connected to pin 5 of J13 on the Protector Series controller. See Figure 3 for the location of J13. A 000660 A Header J13 Figure 3. Protector Series Controller Rear View If a diesel overfill alarm kit IS being installed on the generator, there will already be a wire harness plugged into j13. Temporarily unplug the existing wire harness, insert the Wire 575 into position 5 and plug the harness back into J13. The 6 pin connector housing, included in the kit, will NOT be used and can be discarded. If a diesel overfill alarm kit is NOT being installed on the generator, insert Wire 575 into position 5 of the connector housing included with this kit and plug into J13. 24. Use the included tie wraps to secure the harness in place. This completes the installation. 4 Instruction Sheet

Model No. 006594-0* Network Operations Center (NOC) Interface Instruction Procedure - CPL QT Gaseous Units (if applicable) SNAP TRACK INSTALLATION 1. Identify the snap track mounting location as shown below. See Figure 4. A D B C E 000661 A Starter Contactor (On back of panel) B Diode Bridge DB1 C Snap Track Mounting Location D Route wire harness through this opening E Ground Post Mounting Screw Figure 4. Snap Track Mounting Location NOTE: Verify there is adequate clearance behind the control panel before drilling. Re-route any wire harnesses that may become damaged during drilling and installation. 2. Drill two 1/8 inch holes, in the panel, at the dimple locations. Locating dimples for the snap track have been added to the sheet metal beginning in the 4th quarter of 2013. If locating dimples are not available, hold the snap track in the area shown in Figure 4, and mark the hole locations in the center of each slot in the snap track. Set the snap track aside and drill two 1/8 inch holes in the panel at the marked location. 3. Mount the snap track to the generator panel using the two screws included. Tighten the screws until the back of the snap track is drawn flush with the generator panel. Do NOT use washers with the screws. This could raise the head of the screw and could cause the screw to contact the PCB assembly. 4. Snap the PCB into the snap track. Press the PCB firmly into the snap track until it locks into place. When fully inserted, the PCB will be held firmly in place and will NOT be able to slide up or down in the snap track. Instruction Sheet 5

Network Operations Center (NOC) Interface Instruction Model No. 006594-0* WIRING CONNECTIONS 5. Connect the spade terminal of Wire13, in the kit harness, into the #13 location of the terminal block on the PCB assembly (0K4929). 6. Connect the spade terminal of Wire 0 in the kit harness into the #0 location of the terminal block of the PCB assembly (0K4929). 7. Connect the spade terminal of Wire 14, in the kit harness, into the #14 location of the terminal block on the PCB assembly (0K4929). 8. Connect the spade terminal of Wire 209 to the 209 location of the terminal block on the PCB assembly (0K4929). NOTE: There will be no connection made to the 575 location of the terminal block on the 0K4929 assembly in the CPL QT gaseous units. 9. Connect the N1 and N2 wires coming from the PCB assembly into the N1 and N2 terminals on the customer connect block. 10. Connect the green 12AWG ground wire soldered into the PCB assembly to the mounting screw on the ground post. See wire diagram. 11. Locate the common alarm wires at the back of the engine controller. The common wires are approximately 12 inches long and are terminated with a 1/4 inch male FASTON tab. 12. Plug the female terminal of Wire 209 into one of the two common alarm wires. 13. Plug the female terminal of Wire 210 into the remaining common alarm wire. 14. Remove the nut and connect the ring lug of Wire 0 to the #0 wire location on the starter contactor. Torque the nut to 15 in/lbs maximum. 15. Remove the nut and connect the ring lug of Wire 13 to the #13 location on the starter contactor. Torque the nut to 35 in/lbs maximum. 16. Disconnect the Wire 14 going to diode bridge DB1. 17. Plug the male terminal of Wire 14, in the kit harness, into the #14 wire just disconnected from DB1. 18. Plug the female terminal of Wire 14, in the kit harness, into the original #14 location on DB1. 19. Use the included tie wraps to secure the harness in place. This completes the installation. 6 Instruction Sheet

Model No. 006594-0* Network Operations Center (NOC) Interface Instruction Instruction Sheet 7

Network Operations Center (NOC) Interface Instruction Model No. 006594-0* 8 Instruction Sheet

Model No. 006594-0* Network Operations Center (NOC) Interface Instruction Instruction Sheet 9

Network Operations Center (NOC) Interface Instruction Model No. 006594-0* Part No. 0K5122 Rev C 04/23/2015 Printed in USA Generac Power Systems, Inc. All rights reserved Specifications are subject to change without notice. No reproduction allowed in any form without prior written consent from Generac Power Systems, Inc. Generac Power Systems, Inc. S45 W29290 Hwy. 59 Waukesha, WI 53189 1-888-GENERAC (1-888-436-3722) www.generac.com 10 Instruction Sheet