Operating instructions Binary level sensor LMT /00 06/2011

Similar documents
Operating instructions Binary level sensor. LI214x /00 04/2016

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

Operating instructions Flow monitors SI / / 2010

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

Operating instructions Mechatronic flow sensor SBY /00 03/2011

Operating instructions Flow monitors SI5000 SI / / 2007

Operating instructions Flow monitors SI5002 SI5003 SI / / 2012

Operating instructions Flow monitor SI / / 2013

HFS - High Frequency Limit Level Sensor

Level Sensor with G1/2" Thread Hygienic

Level Sensor with M12 Thread Hygienic

SITRANS P measuring instruments for pressure

OPTISWITCH 6500 C Technical Datasheet

Operating instructions Flow monitor SI / / 2014

Continuous level sensor NSK

OPTISWITCH 6500 C Technical Datasheet

Continuous level sensor NSK

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

High-quality pressure sensor with mounted diaphragm seal With clamp connection Model DSS22T

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Pressure transmitter for elevated media temperatures

Pressure gauge per EN with mounted diaphragm seal With clamp connection Model DSS22F

Magnetic Inductive Flow

Installation instructions BasicRelay CR / / 2012

Hygienic, Elastomer- and Gap Free Process Connections

Continuous Level Sensor NSL-F

Continuous level sensor NSL-F-00, -01, -02

Compact Pressure Transmitter DAN-HH

Electronic Ignition Equipment

Pressure gauge per EN with mounted diaphragm seal With SMS threaded connection Model DSS19F

OPTIFLUX 6000 Technical Datasheet

METAL DETECTOR AND REJECTION SYSTEM FOR PIPELINE APPLICATIONS

Magnetic-Inductive Flow Meter FMI

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Ultrasonic flow switch FWS-141, FWA-141

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

In-line diaphragm seal with sterile connection For sanitary applications Model , aseptic connection per DIN 11864

Pressure gauge in hygienic design with mounted diaphragm seal With clamp connection Model DSS22P

Conductive Multilevel Sensor

Operating instructions Electronic level sensor LK7 / LK /07 04/2006

Pressure transmitter for industrial applications Type MBS 4510

ZB0050 / ZB0051 ZB0070 / ZB0071

Magnetic-Inductive flow Meter fmi

Pressure transmitters for industrial applications Type MBS 4510

Diaphragm seal with sterile connection With union nut (milk thread fitting) Models , , and

Diaphragm seal with sterile connection With clamp connection (Tri-clamp) Models , and

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Overview of types. Technical data

DIAMOND POINT VIBRATING PROBES

Diaphragm pressure gauge, flush For sanitary applications, NS 100 Model PG43SA-D, with integrated diaphragm element monitoring

Series 240 Type and Type Pneumatic Control Valves Type 3347 Hygienic Angle Valve

Diaphragm pressure gauge, flush For sanitary applications Model PG43SA-S, NS 100

Pressure Transmitters for Sanitary Applications Model SA-11

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Level Switch LFFS. Description

Flow measurement FlexFlow PF20H Hygienic flow sensor

BODAS Pressure sensor PR3 series 10

Operating Instructions 07/2013

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Pressure transmitter COMPACT ECOnomic

Insertion magnetic inductive flowmeter

Angle seat valve with piston actuator VZXA-...-K

CombiTemp Accessories

Level Switch LFFS. distributed by Data sheet

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

Technical Datasheet P-30/P-31. Standard transmitter.

The right choice for your application. Pressure sensors from ifm.

Solenoid Valve DF-SA-series

Pressure transmitters for heavy duty applications MBS 3200 and 3250

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

Solenoid Valve DF-SB-series

Conductivity Measuring Sensor InduMax H CLS 52

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Solenoid Valve ST-IA-series

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

Inductive conductivity meter

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

DC/DC converters - MINI-PS DC/ 5-15DC/

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

Operating Instructions April 2008 SITRANS LVL100

Solenoid Valve ST-SA-series

Pressure Sensors. for liquid and gaseous media

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Angle seat valve with diaphragm actuator VZXA-...-M

Thermowell For sanitary applications Model TW22

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Electronic Ignition Module

Pressure transmitters for heavy duty applications Type MBS 3250

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

JUMO MIDAS S05 Pressure transmitter Type

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Accessories, Universal

Transcription:

Operating instructions Binary level sensor LMT UK 706052/00 06/2011

Contents 1 Preliminary note...3 1.1 Symbols used...3 2 Safety instructions...3 3 Functions and features...4 3.1 Application area...4 3.2 Restriction of the application area...5 4 Function...5 4.1 Measuring principle...5 4.2 Processing of the measured signals...5 4.3 Features of the unit...5 4.4 Application examples...6 5 Installation...6 5.1 Installation location / environment...6 5.2 Mounting...7 5.2.1 Clamp adapter / adapter for pipes...8 5.2.2 Welding / screw-in adapter...8 5.3 Notes on 3A compliant installation...9 5.4 Note on the use in accordance with EHEDG...9 6 Electrical connection...10 7 Operation...10 8 Maintenance, repair, disposal...10 9 Scale drawing... 11 10 Technical data...12 11 Notes on the regulation (EC) 1935/2004...12 2

1 Preliminary note 1.1 Symbols used Instruction Cross-reference Important note Non-compliance can result in malfunction or interference. Information Supplementary note. 2 Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur. Installation, electrical connection, set-up, operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator. The unit complies with the standard EN 61000-6-4. In domestic areas (EN 61000-6-3) the unit must be installed in closed metal tanks / pipes. For units the scope of validity culus: The device shall be supplied from an isolating transformer having a secondary Listed fuse rated either a) max 5 amps for voltages 0~20 Vrms (0~28.3 Vp) or b) 100/Vp for voltages of 20~30 Vrms (28.3~42.4 Vp). UK 3

3 Functions and features The unit monitors the level of liquid, viscous and powdery media in tanks and pipes. It can be used for limit detection and run-dry protection. 3.1 Application area Suitable for food and hygienic areas due to food-grade materials and hygienic installation possibilities. Detection of almost all media, even extremely adhering (e.g. ketchup) or nonconductive ones (e.g. vegetable oil). In the following table you can find a selection of tested media and the corresponding recommended unit type. A detailed list is available at www.ifm.com. Medium LMT100 LMT110 Alcohol (40 % vol) Beer (lager) Butter CIP solution *) Chocolate (at approx. 40 C) Grease Jam Ketchup Milk Non-dairy creamer Olive oil Remoulade Sugar (granulated sugar) Water (distilled) Water (tap water) Yogurt, natural *) In the case of heavy wetting by CIP solution, the LMT110 switches as in the case of medium detected. OUT1 = ON und OUT2 = OFF (i.e. the cleaning operation is detected). Always check whether the sensor is appropriate for the corresponding applications without restriction. 4

The unit can be operated at the following medium temperatures: --0 85 C (aqueous media). -- 0 100 C (oils, fats and powdery media). For a limited time (1 h) it can be used at 150 C. Therefore it is suitable for all standard cleaning and sterilisation processes (CIP, SIP). Tank pressure: -1 16 bar. 3.2 Restriction of the application area Not suitable for very abrasive media (e.g. quartz sand). For use in very aggressive media (strong acids and alkali): First check the compatibility of the product materials ( 10 Technical data). Media which are very inhomogeneous separate from each other thus forming separation layers (e.g. oil layer on water): Check the function by an application test. UK 4 Function 4.1 Measuring principle The unit operates to the impedance spectroscopy method. It evaluates the electrical behaviour of the media to be monitored in the frequency range between 50 and 200 MHz. The different media show characteristic behaviour. Also deposits or foam show significantly different behaviour. The presetting of the unit allows detection of the presence of certain media; deposits or foam, however, are suppressed. 4.2 Processing of the measured signals Outputs OUT1 and OUT2 complement each other: - no medium detected: OUT1 = OFF and OUT2 = ON. - medium detected: OUT1 = ON and OUT2 = OFF. 4.3 Features of the unit Food-grade materials: 316L, PEEK. Hygienic installation possibilities without dead band. Approvals / conformities: FDA, EG 1935 / 2004, EHEDG, 3A, UL. Status indication by yellow LED. After application of the operating voltage immediately ready for operation. No settings on the unit necessary. Short response time: switching delay approx. 0.1 s. Defined position of the cable outlet for angled sockets for use of ifm welding adapters. 5

Streamlined sensor geometry, no blockage of the pipe, no pressure loss. 4.4 Application examples 1 2 A A A The unit can be installed at any position. 1: Different installation positions in a tank, e.g. to avoid influences by incomplete mixing of the medium or air inclusions. 2: The fill level in pipes can be monitored by means of a corresponding installation position. In case of strongly adhering and viscous media the installation positions (A) are only suited to some extent. Residues might be detected as level. 5 Installation 5.1 Installation location / environment Installation in pipes from DN25 onwards. Lateral distance to tank walls or structures: min. 15 mm. A correct fit and function of the unit and ingress resistance of the connection are only ensured using ifm adapters. In industrial areas the unit can be installed in non-metal tanks / pipes. For non-metal tanks the metallic surface of the mounting adapter is sufficient as reference earth. 6

In domestic areas the unit must be installed in closed metal tanks / pipes. Do not use additional sealing material (e.g. Teflon tape) at the probe tip (sealing cone). Protect the probe tip against direct sunlight. 5.2 Mounting The unit is installed by means of a mounting adapter. The following components are available as accessories: Welding adapters G½ Version Order no. ball E30055 collar E30056 cylindrical for tanks E43300 cylindrical for pipes E43301 Welding adapter G½ cylindrical for tanks E43309 with 3A approval cylindrical for pipes E43310 Mounting adapters G½ G ¾ E43302 G 1 E43303 DIN11851 DN25 E43304 DIN11851 DN40 E43305 Varivent D50 E43306 Varivent D68 E43307 clamp 1-1,5 ISO 2852 / DIN 32676 E33401 clamp 2 ISO 2852 / DIN 32676 E33402 DN25 SMS E33430 Mounting adapter G½ clamp 1-1,5 ISO 2852 / DIN 32676 E43311 with 3A approval clamp 2 ISO 2852 / DIN 32676 E43312 Cover plug G½ for adapter E43308 UK 7

5.2.1 Clamp adapter / adapter for pipes Slightly grease the thread of the sensor using a lubricating paste which is suitable and approved for the application. Screw the unit into the adapter until it is hand-tight. Do not damage the sealing chamfers. Clamp sensor and adapter into a clamping device. Tighten the clamping device only slightly so that the adapter does not warp. Tighten the sensor using a spanner. Tightening torque: 20...25 Nm. Fix the unit + adapter to the process connection by means of a coupling nut, a clamp flange or the like. 5.2.2 Welding / screw-in adapter Ensure cleanliness of the sealing areas. Remove protective packaging only just before mounting. In case of damaged sealing areas replace the unit or the adapter. Weld or screw the adapter into the tank / pipe. If required, slide the O-ring (A) onto the sensor. It seals the gap on the back between the sensor and the adapter. A Some of the adapters listed above are supplied with the O-ring. Only use O-rings that are supplied with the adapter. Unsuitable O-rings can cause problems with ingress resistance: -- O-ring too large: leakage on the sensor tip. -- O-ring too flat: leakage on the gap on the back between sensor and adapter. Slightly grease the thread of the sensor using a lubricating paste which is suitable and approved for the application. Screw the sensor into the adapter and tighten. Tightening torque: 20 25 Nm. 8

After installation check the tank / pipe for ingress resistance. 5.3 Notes on 3A compliant installation The unit has a 3A approval. It is only valid in conjunction with adapters with 3A approval ( table above). The welding spot must comply with the 3-A standard 74-03, D6.1.4: "The minimum radii for fillets of welds in product contact surfaces shall be not less than 1/4 in. (6.35 mm) except that the minimum radii for such welds may be 1/8 in. (3.18 mm) when the thickness of one or both parts joined is less than 3/16 in. (4.76 mm)." Self-emptying must be ensured by an appropriate installation position (position 1...3). The process connection must be provided with a self-emptying leakage port. This is ensured by using the adapter with 3A approval ( table above). UK 5.4 Note on the use in accordance with EHEDG The unit has an approval in accordance with EHEDG. When the unit is used in hygienic areas to EHEDG in conjunction with the above listed adapters, the following applies: Make sure that the sensors are integrated into the system in accordance with EHEDG. 9

6 Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply to EN 50178, SELV, PELV. Disconnect power. Connect the unit as follows: 1 2 L+ 4: 2: For information about available sockets/connectors see: www.ifm.com Products Accessories 4 3 L 7 Operation When the supply voltage has been applied, the unit is in the operating mode. It carries out its evaluation functions and switches the outputs. Operation indication by LED and output signals: LED OUT1 OUT2 unit ready for operation, no medium detected OFF OFF ON unit ready for operation, medium detected lights ON OFF no operating voltage OFF OFF OFF error / failure flashes OFF OFF 8 Maintenance, repair, disposal From time to time check the probe cap for build-up and damage. Clean the unit if badly soiled In case of damage replace the unit. After removal and before reinstallation of the unit carefully clean the probe neck and the installation slot - especially the sealing cone - with appropriate methods to ensure that it is resistant to ingress and without dead band. It is not possible to repair the unit. 10

After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. In case of returns ensure that the unit is free from soiling, especially of dangerous and toxic substances. For transport only use appropriate packaging to avoid damage of the unit. When changing the medium it might also be necessary to change the type of unit ( 3.1, table). 9 Scale drawing UK 102 88 46 12 30 18 LED 27 G1 2 Dimensions in mm 1: tightening torque 20...25 Nm 11

10 Technical data Operating voltage [V]... 18... 30 DC Current rating [ma]...50 Short-circuit protection, pulsed; protected against reverse polarity and overload Voltage drop [V]... < 2.5 Current consumption [ma]... < 40 Max. tank pressure [bar]... -1...16 Housing materials... PEEK; stainless steel (316L/1.4404), PA12; FPM (Viton) Materials (wetted parts)... PEEK surface characteristics: Ra < 0.8 Protection...IP 68 / IP 69K Protection class...iii Ambient temperature [ C]...0...60 Medium temperature aqueous media [ C] - Duration...0...85 - Peak... 150 (1 h) Medium temperature oils, fats, bulk materials [ C] - Duration...0...100 - Peak... 150 (1 h) Storage temperature [ C]... -25...80 Shock resistance [g]... IEC 60068-2-27: 50 g (11 ms) Vibration resistance [g]... DIN EN 60068-2-6: 20 g (10 2000 Hz) EMC... EN 61000-6-2 :2005 closed tanks: EN 61000-6-3: 2006 open tanks: EN 61000-6-4: 2006 11 Notes on the regulation (EC) 1935/2004 The following components of the product are designed according to the regulation (EC) 1935/2004 for permanent contact with food: - Sensor tip made of PEEK More information at www.ifm.com 12