Operating instructions and spare parts list. FPS15 Tilt table

Similar documents
Operating instructions and spare parts list. Waste powder conveying from recovery container WPS01

WPS02 Waste powder conveying with BIG-BAG station

Operating instructions and spare parts list FPS14 Fresh powder system

Operating instructions and spare parts list. LM01 Level sensor. Translation of the original operating instructions

Application cup for OptiFlex 2 GM03 manual powder gun

Operating instructions and spare parts list. OptiFlex F. Manual coating equipment

Operating Instructions and Spare Parts List. Tilt Table FPS13. Ausgabe 07/02. Tilt Table FPS13

Operating instructions and spare parts list. OptiFlex S. Manual coating equipment

Operating instructions and spare parts list. OptiFlow powder injector (IG02 type)

OptiSpray F Manual coating equipment

Operating instructions and spare parts list. OptiSelect. Manual powder gun

OptiFlow powder injector (IG02 type)

EASY 1-F Powder Coating Equipment

Operating instructions and spare parts list. PZ Powder center with Gematic control unit

Operating instructions and spare parts list. XT08 Horizontal axis

Operating instructions and spare parts list. OptiStar CG07 Manual Gun control unit

Operating instructions and spare parts list. MagicCylinder II Powder coating booth

Operating instructions and spare parts list OptiStar CG07 Manual gun control unit

OptiFlow Plug-in injector (IG02)

Manual coating equipment OptiFlex 2 B

EasySelect GM01-E Manual Powder Gun

OptiCenter OC01 Powder management center

XT 6 Horizontal Axis

OptiGun 2-AE Automatic Powder Gun (GA02)

Operating instructions and spare parts list. ZA06 Reciprocator

MagicCenter MC01 Powder management system

EasySelect-Cup Manual Powder Gun

FPS16 Fresh powder system

Powder injector OptiFlow IG07

Manual powder gun OptiFlex 2 GM03

Powder coating equipment OptiFlex 2 BN (Boron Nitride)

Operating Instructions and Spare Parts List. ZA02 Reciprocator. EIssued 08/03. ZA02 Reciprocator 29

OptiGun 2-AE1 Enamel automatic gun (GA02-E1 type)

Quick reference guide. OptiFlex F. Manual coating equipment. Translation of the original operating instructions

Prodigy HDLV Pump. Customer Product Manual Part A02

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Prodigy HDLV Generation II Pump Panel

Oil-free piston compressors KK and piston vacuum pumps KV

Rolli D6/5A. Operating Instructions HORN GMBH & CO. KG. Product Description. Safety Indications. Mounting. Commissioning.

Turbocharger / A100-L Original assembly instructions English

Assembly instructions PRORUNNER mk1 2

Exchange of rollers from the XTS-Mover

Turbocharger / TPS-H Original assembly instructions English

Operating Instructions and Spare Parts List. PG 1-Cup Gun. Issued 09/98

Assembly and Maintenance Manual Type ASNU

MPS 1-F / MPS 2-F Manual Powder System

Installation, Operation, and Maintenance Manual

Installation manual wall-mounted distributor

Big Bag Unloader. Customer Product manual Part Number Issued 07/17

MPS 1-B / MPS 2-B Manual Powder System

Swing Piston Compressors and Vacuum Pumps

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Assembly and Maintenance Manual Type AS

OptiGun GA03 Automatic powder gun

Turbocharger / TPL-B Original assembly instructions English

Installation manual portable distributors

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

CRS-D Powder Coating Booth with Reverse Jet Cleaning System

MANUAL. Single charger

KeContact P20. User manual

OptiGun GA03-P Automatic powder gun

Operator s and Maintenance Manual

Prodigy HDLV Pump Manifold and Circuit Board

Encore HD Powder Spray System with Prodigy Pump Cabinet

Rotary feed-through DDF-S/-KS

Mechanical Operating Instructions

HST-BL-2830MS & HST-BL-2830MS-USA

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

Translation of the Original Operating Manual. Automatic Powder Spray Gun PEA-C4XL-S. Version 03 / II 2 D EEx 2mJ 85 C P_02330

Mod: KLD6-12/35XLAS-N

APS 2. Automatic Powder System

Installation, Operation, and Maintenance Manual

PG 1-A Automatic Powder Gun

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Printed: Doc-Nr: PUB / / 000 / 00

Manual coating equipment OptiFlex 2 B

INSTALLATION OPERATION AND MAINTENANCE MANUAL SMITSVONK HIGH ENERGY IGNITION UNIT TYPE: E-LIGHT

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

2025 Digiflow Airfluid Manual Powder System. Operating Manual

The pneumatic applicator complies with the following safety guidelines: CE

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

DC Master 24/ A

Relay Retrofit Program Cutting Tool Safety Guide

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

INSTRUCTION MANUAL. I/P Converter DSG BXXY3Z DSG BXXY4Z

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Operating manual. High-voltage testing adapter VAS 6558A/30. Operating manual. Customer documentation Revision: 00 Version: 07/2018

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

Assembly and maintenance manual Type FSO, FSO-GR, FS, HPI

SPARK PLUG CLEANING KIT OPERATING MANUAL

AUTOMATIC AIRSPRAY GUN

SCOPELITE TIMING LIGHT OPERATING MANUAL

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

IMPORTANT SAFETY NOTICE

DIAPHRAGM PUMPS: Instruction Manual

Assembly and Maintenance Manual Type RSBW

The information in this instruction manual is subject to modifications without prior notice and is the exclusive property of Zorzini.

Solenoid Operator 0516 / 1216

Transcription:

En Operating instructions and spare parts list FPS5 Tilt table

Documentation FPS5 Tilt table Copyright 004 ITW Gema AG All rights reserved. This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of ITW Gema AG. OptiTronic, OptiGun, EasyTronic, EasySelect, EasyFlow and Super- Corona are registered trademarks of ITW Gema AG. OptiMatic, OptiMove, OptiMaster, OptiPlus, MultiTronic and Gematic are trademarks of ITW Gema AG. All other product names are trademarks or registered trademarks of their respective holders. Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders. To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of issue. ITW Gema AG makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice. Printed in Switzerland ITW Gema AG Mövenstrasse 7 905 St. Gallen Switzerland Phone: +4-7-33 83 00 Fax.: +4-7-33 83 83 E-Mail: info@itwgema.ch Homepage: www.itwgema.ch

Table of contents General safety regulations 3 Safety symbols (pictograms)...3 Conformity of use...3 Technical safety regulations for stationary electrostatic powder spraying equipment...4 General...4 Safety conscious working...5 Individual safety regulations for the operating firm and/or operating personnel...5 Notes on special types of hazard...6 Safety requirements for electrostatic powder coating...7 A summary of the rules and regulations...8 Special security measures...0 About this manual General information... Function description 3 Field of application...3 Function...3 Mechanical construction...4 Safety and monitoring features...4 Control cabinet...5 Technical Data 7 FPS5 Tilt table...7 General Data...7 Control unit...7 Control signal for powder feed...7 Start-up 9 Setting up and mounting...9 Operation...9 Safety barrier... Schematic diagrams 3 Pneumatic diagram...3 Electrical diagram, part...4 Electrical diagram, part...5 Spare parts list 7 Ordering spare parts...7 FPS5 Tilt table - spare parts list...8 Control cabinet - spare parts list...30 FPS5 Tilt table Table of contents

General safety regulations Safety symbols (pictograms) This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the FPS5 Tilt table. These safety regulations must be read and understood before the FPS5 Tilt table is used. The following warnings with their meanings can be found in the ITW Gema operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions. DANGER! Danger due to live electricity or moving parts. Possible consequences: Death or serious injury WARNING! Improper use of the equipment could damage the machine or cause it to malfunction. Possible consequences: minor injuries or damage to equipment INFORMATION! Useful tips and other information Conformity of use. The FPS5 Tilt table is built to the latest specification and conforms to the recognized technical safety regulations. It is designed for the normal application of powder coating.. Any other use is considered as non-conform. The manufacturer is not responsible for damage resulting from improper use of this equipment; the end-user alone is responsible. If the FPS5 Tilt table is to be used for other purposes or other substances outside of our guidelines, then ITW Gema AG should be consulted. 3. Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of the conformity of use. The FPS5 Tilt table should only be used, maintained FPS5 Tilt table General safety regulations 3

and started up by trained personnel, who are informed about and are familiar with the possible hazards involved. 4. Start-up (i.e. the execution of a particular operation) is forbidden until it has been established that the FPS5 Tilt table has been set up and wired according to the guidelines for machinery (98/37/EG). EN 6004- (machine safety) must also be observed. 5. Unauthorized modifications to the FPS5 Tilt table exempts the manufacturer from any liability from resulting damage. 6. The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations, are to be observed. 7. Furthermore, the country-specific safety regulations must be observed. Technical safety regulations for stationary electrostatic powder spraying equipment General The powder spraying equipment of ITW Gema is designed with safety in mind and is built according to the latest technological specifications. This equipment can be dangerous if it is not used for its specified purpose. Consequently it should be noted, that there exists a danger to life and limb of the user or third party, a danger of damage to the equipment and other machinery belonging to the user and a hazard to the efficient operation of the equipment.. The powder spraying equipment should only be started up and used once the operating instructions have been carefully studied. Incorrect use of the controlling device can lead to accidents, malfunction or damage to the control itself.. Before every start-up, check the equipment for operational safety (regular servicing is essential)! 3. Safety regulations BGI 764 and VDE regulations DIN VDE 047, part, must be observed for safe operation. 4. Safety precautions specified by local legislation must be observed! 5. Before opening the devices for repair, they must be disconnected from the mains! 6. The plug and socket connections between the powder spraying equipment and the mains network should only be removed when the power supply is switched off. 7. The connecting cables between the control unit and the spray gun must be laid out in such a way that they cannot be damaged during operation. Safety precautions specified by local legislation must be observed! 8. Only original ITW-Gema spare parts should be used, because the explosion protection will be preserved that way. Any warranty claim is void, if damage occurs by using no ITW Gema parts. 4 General safety regulations FPS5 Tilt table

9. If ITW Gema powder spraying equipment is used in conjunction with machinery from other manufacturers, then their safety regulations must also be taken into account. 0. Before starting work familiarize yourself with all installations and operating elements, as well as with their functions! Familiarization during operation is too late!. Caution must be exercised when working with a powder/air mixture! A powder/air mixture in the right concentration is flammable! Smoking is forbidden in the entire plant area!. As a general rule for all powder spraying installations, persons with pacemakers should never enter high voltage areas or areas with electromagnetic fields. Persons with pacemakers should not enter areas with powder spraying installations! WARNING! We advert that the customer himself is responsible for the safe operation of equipment. ITW-Gema AG is in no way responsible for any resulting damages! Safety conscious working Each person responsible for the assembly, start-up, operation, service and repair of powder spraying equipment must have read and understood the operating instructions and the Safety regulations chapter. The operator must ensure that the user has had the appropriate training for powder spraying equipment and is aware of the possible sources of danger. The control devices for the spray guns must only be set up and used in zone. Spray guns are certified for the zone. The powder spraying equipment should only be used by trained and authorized personnel. This applies to modifications to the electrical equipment, which should only be carried out by a specialist. The shutdown procedures given in the operating instructions on all work concerning assembly, start-up, setting up, operation, modification of operating conditions and operating methods, maintenance, inspection and repair are to be observed as necessary. The powder spray equipment can be turned off by using the main switch or failing that, the emergency shutdown. Individual components can be turned off during operation by using the appropriate switches. Individual safety regulations for the operating firm and/or operating personnel. Any operating method which will negatively influence the technical safety of the powder spraying equipment is to be avoided.. The operator has to ensure that no non-authorized persons work on the powder spraying equipment (e.g. this also includes using the equipment for non-conform work). 3. For dangerous materials, the employer has to provide an operating instructions manual for specifying the dangers arising for humans and environment by handling dangerous materials, as well as the necessary preventive measures and behavior rules. The operating instructions manual has to be written in an under- FPS5 Tilt table General safety regulations 5

standable form and in the language of the persons employed, and has to be announced in a suitable place in the working area. 4. The operator is under obligation to check the powder spraying equipment at least once every shift for signs of external damage, defects or changes (including the operating characteristics) which could influence safety and to report them immediately. 5. The operating enterprise has to ensure that GEMA electrostatic spraying equipment is only operated in perfect condition. 6. As far as is necessary, the operating firm must ensure that the operating personnel wear protective clothing (e.g. facemasks). 7. The operating firm must guarantee cleanliness and an overview of the workplace with suitable instructions and checks in and around the powder spraying equipment. 8. No safety devices should be dismantled or put out of operation. If the dismantling of a safety device for set-up, repair or servicing is necessary, reassembly of the safety devices must take place immediately after the maintenance or repair work is finished. All maintenance activities must be executed when the powder spraying mechanism is switched off. The operator must train and commit the responsible personnel to this. 9. Activities such as checking powder fluidization or checking the high-voltage spray gun etc. must be carried out when the powder spraying equipment is switched on. Notes on special types of hazard Power/electrical tension It is necessary to refer once more to the danger of life from high voltage current if the shutdown procedures are not observed. High voltage equipment must not be opened - the plug must first be taken out - otherwise there is danger of electric shock. Powder Powder/air mixtures can be ignited by sparks. There must be sufficient ventilation in the powder coating booth. Powder lying on the floor around the powder spraying equipment is a potentially dangerous source of slipping. Static charges Static charges can have the following consequences: Charges to people, electric shocks, sparking. Charging of objects must be avoided - see "Earthing". Grounding All electricity conducting parts and machinery found in the workplace (according to DIN VDE 0745, part 0) must be grounded.5 meters either side and.5 meters around each booth opening. The grounding resistance must amount to MOhm. The resistance must be tested regularly. The condition of the work piece attachments as well as the hangers must guarantee that the work pieces remain grounded. If the grounding of the work pieces takes place by their attachments, these must constantly be kept clean in order to guarantee the necessary conductivity. The appro- 6 General safety regulations FPS5 Tilt table

priate measuring devices must be kept ready in the workplace in order to check the grounding. Compressed air When there are longer pauses or standstill times between working, the powder spraying equipment should be drained of compressed air. There is a danger of injury when pneumatic hoses are damaged, or when an uncontrolled release and improper use of compressed air happens. Crushing and cutting During operation, moving parts may automatically start to move in the operating area. It must be ensured, that only instructed and trained personnel go near these parts. The operator should ensure that barriers comply with the local security regulations. Access under exceptional circumstances The user enterprise has to ensure due to the local conditions, that when repairs at the electrical part or restarting operation activities are done, additional measures such as providing with gates against the admission of unauthorized persons are absolutely executed. Prohibition of unauthorized conversions and modifications to machines All unauthorized conversions and modifications to electrostatic spraying equipment are forbidden for safety reasons. The powder spraying equipment should not be used if damaged, and the faulty part must be immediately replaced or repaired. Only original ITW- Gema replacement parts should be used. Any warranty claim is void, if damage occurs by using no ITW Gema parts. Repairs must only be carried out by specialists or in ITW-Gema workshops. Unauthorized conversions and modifications may lead to injury or damage to machinery. The ITW Gema AG guarantee would no longer be valid. Safety requirements for electrostatic powder coating. This equipment can be dangerous, if the instructions in this operating manual are not followed.. All electrostatic conductive parts, in particular the work pieces within 5 meters of the coating equipment, must be grounded. 3. The floor in the coating area must be electrically conductive (normal concrete is generally conductive). 4. The operating personnel must wear electrically conductive footwear (e.g. leather soles). 5. The operating personnel should hold the gun in the bare hand. If gloves are worn, they must be electrically conductive. 6. The supplied grounding cable (green/yellow) must be connected to the grounding screw of the manual electrostatic powder spraying equipment. The grounding cable must have a good metal to metal connection with the coating booth, the recovery unit and the work piece conveyor system, especially with the work piece suspension. FPS5 Tilt table General safety regulations 7

7. The electricity and powder supply to the hand guns must be set up in such a way that they are fully protected against heat and chemical damage. 8. The powder coating equipment may be able to be switched on only if the booth is in operation. If the booth stops, then the powder coating device must switch off too. 9. The grounding of all electricity conducting devices (e.g. hooks, conveyor chains) must be checked weekly. The grounding resistance must amount to MOhm. 0. The control unit must be switched off, if the hand gun is cleaned or the nozzle is changed.. When working with cleaning agents, there may be a risk of hazardous fumes. By handling these agents, absolutely consider the manufacturer indications!. The manufacturer's instructions and the applicable environmental requirements must be observed when disposing of powder lacquer and cleaning agents. 3. If any part of the spray gun is damaged (broken parts, fractures) or missing, then it should not be used. 4. For your own safety, only use accessories and attachments listed in the operating instructions. The use of other individual parts can lead to risk of injury. Only original ITW-Gema replacement parts should be used. 5. Repairs must only be carried out by specialists and under no circumstances should they be carried out in the operating area. The ignition protection must not be compromised. 6. Conditions leading to dangerous levels of dust concentration in the powder spraying booths or in the powder spraying areas, must be avoided. A sufficient technical ventilation must be available, to prevent a dust concentration of more than 50% of the lower explosion limit (UEG) (UEG = max. permissible powder/air concentration). If the UEG is not known, then a value of 0 g/m³ should be used. A summary of the rules and regulations The following is a list of relevant rules and regulations which are to be observed: Guidelines and regulations, German professional association BGV A BGV A BGI 764 BGR 3 VDMA 437 General regulations Electrical equipment and material Electrostatic coating Guidelines for the avoidance of the dangers of ignition due to electrostatic charging (Guideline Static electricity ) Guidelines for electrostatic coating with synthetic powder ) - part General requirements - part Examples of use 8 General safety regulations FPS5 Tilt table

Leaflets ZH /30 Leaflet for the use of tools in locations where there is danger of explosion ) EN European standards RL94/9/EG EN 9- EN 9- EN 50 04 to EN 50 00, identical: DIN VDE 070/07 EN 50,050 EN 50 053 Teil EN 50 77 PR EN 98 EN 6059, identical: DIN 40050 EN 60 04 identical: DIN VDE 03 The approximation of the laws of the Member States relating to apparatus and safety systems for their intended use in potentially explosive atmospheres Machine safety ) Electrical equipment for locations where there is danger of explosion 3) Electrical apparatus for potentially explosive atmospheres - Electrostatic hand-held spraying equipment ) Requirements for the selection, installation and use of electrostatic spraying equipment for flammable materials - Manual electrostatic powder spray guns ) Stationary electrostatic spraying equipment for flammable coating powder ) Coating plants - Spray booths for application of organic powder coating material/safety requirements IP protection types; contact, foreign bodies and water protection for electrical equipment ) VDE regulations for the setting up of high-voltage electrical machine tools and processing machines with nominal voltages up to 000 V 3) VDE (Association of German Engineers) Regulations DIN VDE 000 DIN VDE 005 part part 4 DIN VDE 047 part DIN VDE 065 *Sources: Regulations for setting-up high voltage equipment with nominal voltages up to 000V 4) VDE regulations for the operation of high voltage equipment 4) General regulations Supplementary definitions for stationary electrical spraying equipment Setting up stationary electrostatic spraying equipment 4) Setting up electrical equipment in locations in areas with danger of explosion 4) ) Carl Heymanns Verlag KG, Luxemburger Strasse 449, 5000 Köln 4, or from the appropriate employers association ) Beuth Verlag GmbH, Burgrafenstrasse 4, 000 Berlin 30 3) General secretariat, Rue Bréderode, B-000 Bruxelles, or the appropriate national committee 4) VDE Verlag GmbH, Bismarckstrasse 33, 000 Berlin FPS5 Tilt table General safety regulations 9

Special security measures - The installation work, to be done by the customer, must be carried out according to local regulations - Before starting up the plant, check if no foreign objects are in the booth or in the ducting (input and exhaust air) - It must be observed, that all components of the plant are grounded according to the local regulations 0 General safety regulations FPS5 Tilt table

About this manual General information These operating manual contains all important information which you require for the working with the FPS5 Tilt table. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system. Information about the function mode of the individual system components - reciprocators, booths, powder gun controls, powder guns etc. - you will find in the corresponding enclosed documentations. FPS5 Tilt table About this manual

Function description Field of application The FPS5 Tilt table is used for the fresh powder supply from the manufacturer's container to the powder containers or powder guns. The powder conveying takes place by powder pumps with integrated powder fluidizing and distributing equipment (so-called powder fluidization). The Tilt table can be subsequently integrated into any powder coating system. FPS5 Tilt table Function The powder container is placed directly onto the vibration table and vibrated by the motor mounted laterally on the table. For fluidizing the powder, in addition to table vibration, fluidizing air is fed into the exterior tube of the fluidizing/suction unit, where it emerges at the lower end through the fluidizing pad. The area around the suction tube is fluidized, the powder acquires fluid-like characteristics and is sucked up into the tube. The table vibration causes a better flow of powder to the suction tubes and prevents accumulation of residual powder in the corners of the container. By tilting up to 40 degrees, the powder flows to the lower bundle FPS5 Tilt table Function description 3

edge and can be delivered almost completely. The vibrated and fluidized powder is sucked up by the conveying air by the suction tube into the powder pump and carried on. Note: The vibration and the powder conveying only works, if the level sensor does not announce lack of powder in the main powder container! Mechanical construction Depending the version, the Tilt table can be equipped with -4 fluidizing/suction units. 3 6 4 5 FPS5 Tilt table - mechanical structure Safety and monitoring features Frame 4 Rubber damper Tilt plate 5 Pedestal bearing 3 Pneumatic cylinders 6 Tilt frame - All moving axes must be secured before starting-up and during operation by safety barriers, provided by the customer (see local regulations) - The pneumatic cylinders are equipped with firm screens, so that fast movements are not possible - The Tilt table may only be start-up after the security gate is closed - The security gate must be locked in such a way, that it can be opened only after lowering the Tilt table 4 Function description FPS5 Tilt table

Control cabinet In the FPS5 control cabinet, the pneumatic and electrical elements and the control devices are implemented. The operation components (pressure control valves) are also situated in the control cabinet. FPS5 Tilt table - control cabinet The control cabinet must be positioned outside of the safety barriers, respectively the danger area. It can be firmly fixed on the floor. FPS5 Tilt table Function description 5

Technical Data FPS5 Tilt table General Data FPS5 Tilt table Pay load Dead weight Motor voltage Frequency Compressed air, max. input pressure Air requirement for tilting Air requirement for the pumps Compressed air quality: Max. water vapor content Max. oil vapor content Control unit FPS5 Tilt table Input voltage Input power Frequency max. 550 kg (.5 pounds) approx. 00 kg (440.9 pounds) 3 x 400 VAC 50 Hz 0 bar / 45 psi less than Nm³/h (0.6 SCFM) see the technical data of the powder pump,3 g/m³ 0, mg/m³ 3 x 400 V+N+E 00 W 50 Hz Control signal for powder feed FPS5 Tilt table Control signal Potential free contact or 4 VDC or 30 VAC FPS5 Tilt table Technical Data 7

Start-up Setting up and mounting - After unpacking and setting up the Tilt table, it must absolutely be fixed on the floor with the provided steel bolts - Sufficient working space for loading and unloading the Tilt table must be provided - The frame of the Tilt table must be grounded together with the plant - To charge the tilt plate with the hand-operated lift truck, the optionally supplied ramp is to be used. This ramp must be screwed firmly on the floor - The Tilt table must be equipped with a safety barrier, which prevents the admission for unauthorized persons Operation Move the fluidizing/suction unit(s) manually upwards, lock the retaining slide and place the powder container on the Tilt table. Fluidizing/suction unit on upper position FPS5 Tilt table Start-up 9

Push back the retaining slide and move manually the fluidizing/suction unit(s) slowly downwards. Attention: Do not let drop down, otherwise the fluidizing pads can be damaged! Press the green push button on the control cabinet to release the tilting procedure. Attention: Due to the inserted safety throttles, the tilting procedure works just slowly, i.e. after the required tilting pressure is adjusted, it takes approx. 0 sec. until the movement becomes visible! The tilting procedure is started as follows: Pressure regulator Tilting basic position 6 bar Pressure regulator Tilting empty position 3 bar Pressure regulator Pressure regulator Pressure regulators in the control cabinet After releasing the tilting procedure, the full powder container is lifted into the tilting basic position. The Tilt table continues to incline automatically up to the end position, during the powder discharge. The time for additional tilting is determined by the pressure regulator. This pressure regulator must be readjusted depending on the powder type etc.: - If too little powder in the tilting basic position flows to the suction tube, the pressure must be increased - If the Tilt table moves to the empty position although there is still enough powder to the suction tube, the pressure can be reduced If the powder container is emptied, press the red stop button. The Tilt table lowers back into the horizontal position. Lift the fluidizing/suction unit(s) manually upwards, change the powder container and continue operating. 0 Start-up FPS5 Tilt table

Safety barrier An optional security gate is supplied by ITW Gema AG, which has the following characteristics: - Wing door for charging the tilt plate and for committing the safety area - With electrical safety limit switch - With pneumatically interlocking, which prevents a committing during the tilting procedure - Safety grids for all three sides (depending on requirement), which are fixed on the floor The connections for the electrical and pneumatic interlocking are implemented in the control cabinet. FPS5 Tilt table Start-up

Schematic diagrams Pneumatic diagram.3 Y X. X. X.3 X.4 PP0 3 3 3 3 3 5 4 3 5 4 P R 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 A. 0-0 bar..4.5.6 Y Y3 Y4 PP0 PP0 PP0 Number of powder pumps (in accordance with order) Powder pumps. Control cabinet Up Down Stroke Stroke.4.6.7 3. 3.3 0-0 bar 0-0 bar 3. 3.4.5.8 3.5 3.6 4. 4. 4.3 4.4 4.5 4.6 4.7 4.8 4.9 4.0 4. 4.3 Double stroke cylinder Double stroke cylinder FPS5 Tilt table - pneumatic diagram FPS5 Tilt table Schematic diagrams 3

3 4 3 4 5 6 5 6 3 3 4 5 6 V 0/07 Electrical diagram, part 4mmý Q 7 Q 0. 6A. 0 3 4 5 6 7 8 9 0. 63A RT 400V 0V P: 400V S: 30V/ 0VA - T 0V 30V L4 L5 L6 KM Q0. 5A L L L3 SCHWARZ L4 /. 0 N /. 0 4mmý mm. 5mm - X 0 L L L3 3 4 5 6 7 8 9 - X 0 W3 C E 3xmm br bl W Y Y x mm W 3x 400V+N+ Y Y 4xmm Kunde EX X _ EX _ X Y 30V EX connection 30 VAC A99 4 3 X99 Power input: 3 kva Preliminary fuse: max. 0 A Short circuit current: 5 ka U V W The neutral wire is used in this control! M 3 ~ M Main solenoid valve Safety barrier Grounding of the control transformer Power supply Vibration motor 0,8 kw FPS5 Tilt table - electrical diagram, part (continues on the next page) 4 Schematic diagrams FPS5 Tilt table

. V 0/07 Electrical diagram, part 0 3 4 5 6 7 8 9 0.9/ L4 3 3 KM S0.. STEUERUNG 4 4 MAN. - AUT O. Y/ Y K3. 4 4 4 K K.. 3 4 A A A A K KM K K3 30V A 30V A A 30V A or ange 0. 9/ N 0 3 4 5 6 7 8 9 0 3 4 5 6 7 - X0 W4 Y Y W3 YY W7 C E W8 C E W9 C E W0 CE x mm xmm 3xmm 3x mm 3xmm 3xmm br bl br bl br bl br bl Kunde Kunde X X X X Y3 Y4 Y5 X 30V X 30V X 30V X EX Y 4V 0V 30V VERSORGUNGSZENTRUM VZ- 5 / AL MASTER 4. 4 4. 4 0. 3 4. 3 4 0. 4 5 6 0. 4 4 3 4. 5 Fresh powder supply solenoid valves ON/OFF Autom. fresh powder supply with external 30 V ON/OFF Autom. fresh powder supply with external 4 V ON/OFF Fresh powder supply ON/OFF Autom. fresh powder supply External contact for automatic operation FPS5 Tilt table - electrical diagram, part FPS5 Tilt table Schematic diagrams 5

Spare parts list Ordering spare parts When ordering spare parts for powder coating equipment, please indicate the following specifications: - Type and serial number of your powder coating equipment - Order number, quantity and description of each spare part Example: - Type FPS5 Tilt table Serial number 34 5678 - Order no. 03 386, piece, Clamp - Ø 8/5 mm When ordering cable or hose material, the required length must also be given. The spare part numbers of this yard/meter ware is always marked with an *. The wear parts are always marked with a #. All dimensions of plastic hoses are specified with the external and internal diameter: Example: Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d) WARNING! Only original ITW-Gema spare parts should be used, because the explosion protection will also be preserved that way. The use of spare parts from other manufacturers will invalidate the ITW Gema guarantee conditions! FPS5 Tilt table Spare parts list 7

FPS5 Tilt table - spare parts list Control cabinet - complete Clamping element - Ø 40/40 mm 363 90 Pump holder - complete 390 887 3 PP0 Powder pump - complete (see corresponding documentation) 357 90 4 Fluidizing/suction unit - complete (see corresponding documentation) 370 843 5 Vibration damper - Ø 75x55 mm, M /.000.7703 6 Pedestal bearing - NP 50 DEC 7 Buffer stopper - Ø 75x35 mm, M /.0007.0803 8 Vibrator 58 68 9 Bezel - 0,9 mm 403 65 0 Ball joint - W 0950 800 5 Pneumatic cylinder - 50 S 000 0 XP-00-0 8 Spare parts list FPS5 Tilt table

FPS5 Tilt table - spare parts list 4 3 5 6 FPS5 Tilt table 7 8 FPS5 Tilt table - vibrator 0 9 FPS5 Tilt table - pneumatic cylinder FPS5 Tilt table Spare parts list 9

Control cabinet - spare parts list. Pressure regulator 43 70. Pressure gauge 03 89.3 Solenoid valve 59 500.4 Solenoid valve 59 500.5 Solenoid valve 59 500.6 Solenoid valve 59 500. Solenoid valve 53 95 Silencer for pos.. 5 305. Bezel - 0.9 mm (not shown) 403 65.4 Push button - green 67 830 Valve for pos..4 68 59 Carrier plate for pos..4 68 40.5 OR-Valve 59 7.6 Pressure display - green 65 705.7 Push button - red 67 848 Valve for pos..7 68 67 Carrier plate for pos..7 68 40.8 Pneumatic valve 53 944 Silencer for pos..8 5 305 3. Pressure reducing valve 64 34 3. Manometer 58 989 3.3 Pressure reducing valve 64 34 3.4 Pressure gauge 58 989 3.5 Pneumatic valve 64 50 3.6 Silencer for pos. 3.5 5 305 3.7 Backstroke screw connection - 7984 06 0 3.8 Backstroke screw connection - 7984 06 0 3.9 Backstroke screw connection - 7984 06 0 3.0 Backstroke screw connection - 7984 06 0 (The positions in this list are taken from the pneumatic diagram) 30 Spare parts list FPS5 Tilt table

Control cabinet - spare parts list..3-.6 3. 3.4. 3. 3.3.3-.6.8..4.6.7.5 3.7-3.0 3.5 3.6 Control cabinet - inside view FPS5 Tilt table Spare parts list 3