ABB wind turbine converters. Supplement to hardware manual ACS upgrade kits

Similar documents
ACS800. Hardware Manual ACS Wind Turbine Converters for Asynchronous Slip Ring Generators

ACS800. Hardware Manual ACS Drives (55 to 2500 kw / 75 to 2800 HP)

ABB wind turbine converters. Supplement to system description and start-up guide ACS upgrade wind turbine converters

Hardware manual Sine filters

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U31 Drives (7.5 to 125 HP)

ABB industrial drives. Option description Bypass connection for ACS880-07, -17, and -37 drives ( A)

Preventive maintenance kits

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U7 Drives (50 to 600 HP)

ACS 800. Hardware Manual ACS Drives (75 to 1120 kw)

ABB LOW VOLTAGE AC DRIVES, WIND TURBINE CONVERTERS AND SOLAR INVERTERS Converter modules with electrolytic DC capacitors in the DC link Capacitor

ACS 800. Hardware Manual ACS Drives (500 to 2800 kw)

ABB SINGLE DRIVES ACS880-01/04 +C132 marine typeapproved. Supplement

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U7 Drives (50 to 600 HP)

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U11 Drives (7.5 to 125 HP)

ABB industrial drives. Supplement ACS N7502 drives for SynRM motors (0.8 to 200 kw)

ABB machinery drives. Application guide Common DC system for ACS380 drives

R5 ACS580-01, ACH580-01

ACS800. Hardware Manual ACS Drives (0.55 to 110 kw) ACS800-U1 Drives (0.75 to 150 HP)

ACS800. Hardware Manual ACS Drives (45 to 560 kw) ACS800-U2 Drives (60 to 600 HP)

ACS 800. Hardware Manual ACS Drive Modules (90 to 500 kw) ACS800-U4 Drive Modules (125 to 600 HP)

ACS800. Hardware Manual ACS Drives (45 to 500 kw) ACS800-U2 Drives (60 to 600 HP)

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U31 Drives (7.5 to 125 hp)

ACS 800. Hardware Manual ACS Drives (0.55 to 110 kw) ACS800-U1 Drives (0.75 to 150 HP)

ACSM1. Hardware Manual ACSM1-04 Drive Modules (0.75 to 45 kw)

ACS 800. Hardware Manual ACS Drives (90 to 500 kw) ACS800-U2 Drives (125 to 600 HP)

Frequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

Capacitor reforming instructions Converter modules with electrolytic DC capacitors in the DC link

Product Structure. ABB Industrial drives, ACS800-31

ABB industrial drive ACS800 multidrive, 1.5 kw kw ACS800 multidrive modules, 1.5 kw kw Technical catalogue

Units with pedestal and busbars on the short side (+H360, flat mounting)

User s Manual. ACS550-PC/PD Packaged Drive with Disconnect Supplement to ACS550-01/U1 User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

ABB machinery drives. Hardware manual ACS drive modules (55 to 200 kw, 60 to 200 hp)

ABB industrial drives ACS800, drive modules 0.55 to 2900 kw Catalog

ABB MACHINERY DRIVES ACS380 drives Recycling instructions and environmental information

ACS580, ACH580 and ACQ580 drive module frames R3 and R5 to R9 for cabinet installation (options +P940 and +P944) Supplement

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac

UNITROL 6800 excitation systems Proven performance solutions

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

ABB industrial drives. Application guide ACS drives and ACS drive modules Common DC systems

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

ABB industrial drives ACS800, multidrives, 1.5 to 5600 kw

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Update notice. General safety. Type code key. Update notice 1

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual

ABB Drives. Recycling instructions and environmental information SAMI STAR product family

4100C BOSS AC Shovel Drive System Overview. WMEA Edmonton - June 2008

ABB industrial drives ACS800, single drives, 0.55 to 5600 kw

ABB industrial drives ACS800, single drives, 0.75 to 6000 hp

Welcome to the Applications training module for the ACS800 Single drives. If you need help navigating this module, please click the Help button in

Installation of ACN/ACW644 +V991 Spare part Phase module kit and operation instructions AND dc-capacitor reforming guide

ABB central inverters PVS to 1000 kw

ABB Drives. Recycling instructions and environmental information ACSM1 product family

ABB industrial drives ACS800, single drives, 0.55 to 2800 kw

Frame size R2, IP20 / NEMA 1

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

Medium voltage drive for single or multimotor applications, 3 27 MW

Product brochure. Medium voltage AC drive ACS 2000, 4kV 6.9kV HP

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Electronic Ballast EVG 2000-T

Mining Electrical Maintenance and Safety Association Clearwater Florida June Draglines AC Drive Applications

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Catalog. ABB industrial drives ACS800, single drives, 0.55 to 5600 kw

MODVAR Low voltage reactive power compensation modules Installation manual

Hardware Manual ACS 600. ACS/ACC/ACP 601 Frequency Converters 2.2 to 110 kw (3 to 150 HP)

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

Diesel-Electric Propulsion Systems Power under Control

ABB general purpose drives. Recycling instructions and environmental information ACS480 drives

Question Number: 1. (a)

ABB low voltage wind turbine converters Reliable technology for wind power

Low voltage AC drives. ABB industrial drives ACS880, multidrives 1.5 to 5600 kw Catalog

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Low voltage AC drives

SINAMICS GM150 IGCT version

Low voltage AC drives. ABB industrial drives ACS800, multidrives 1.1 to 5600 kw Catalog

DCT880. Quick guide DCT880 Thyristor power controller (20 A bis 4160 A)

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help

High performance Vector Control. Ratings. System configuration

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Installation and Maintenancee Manual

ABB central inverters PVS to 2000 kva

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

DR8010 tm. Hardware Reference Manual. Document Revision B4 May 15, 2018

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

ABB low voltage wind turbine converters Reliable technology for wind power

Cabinet-built single drives, ACS880-07

AC/DC FFE converter power module

ABB central inverters PVS to 1000 kw

Drive IT Low Voltage AC Drive. ACS 600 Catalogue SingleDrive ACS 600, 1.5 kw-3000 kw MultiDrive ACS 600, 2.2 kw-4300 kw Related tools and accessories

Product information. ECOSS Electronic compact starter for wound rotor drives

RT2DB Excitation and voltage regulation system for synchronous generators

Transcription:

ABB wind turbine converters Supplement to hardware manual ACS800-67 upgrade kits

List of related manuals ACS800-67 manuals ACS800-67 wind turbine converters for asynchronous slip ring generators hardware manual ACS800-67 wind turbine converters system description and startup guide ACS800-67 upgrade wind turbine converters supplement ACS800-67 upgrade kits supplement to hardware manual Code (English) 3AFE68392454 3AUA0000095094 3AXD50000131303 3AXD50000226726 Firmware manuals and guides ACS800 IGBT supply control program firmware manual ACS800 grid-side control program firmware manual ACS800-67(LC) doubly-fed induction generator control program firmware manual 3AFE68315735 3AUA0000075077 3AUA0000071689 Option manuals and guides Manuals and quick guides for I/O extension modules, fieldbus adapter, etc. For manuals, contact your local ABB representative.

Supplement to hardware manual ACS800-67 upgrade kits Table of contents 3. Installation 2018 ABB Oy. All Rights Reserved. 3AXD50000226726 Rev. A EN EFFECTIVE: 2018-02-15

5 Table of contents 1. About this manual Contents of this chapter.................................................. 7 Safety instructions....................................................... 7 Target audience........................................................ 7 Contents of this manual.................................................. 7 Applicability and scope................................................... 8 Terms and abbreviations.................................................. 9 2. Hardware description Contents of this chapter................................................. 11 Cabinet layout......................................................... 12 Upgrade kits.......................................................... 13 Other upgrades........................................................ 14 Optional kits........................................................ 14 3. Installation Contents of this chapter................................................. 15 Safety instructions...................................................... 15 Installation process with stress check period................................. 16 Installation process when all installations are done simultaneously (no stress check period) 16 Installation instructions.................................................. 17 4. Maintenance Contents of this chapter................................................. 19 Safety instructions...................................................... 19 Maintenance intervals................................................... 20 Description of symbols................................................ 20 Recommended maintenance intervals.................................... 20 Maintenance instructions................................................ 21 Active crowbar A2 and/or crowbar resistor replacement...................... 21 Installing the crowbar assembly back to cabinet............................ 24 NDBU and NAMU plate replacement..................................... 25 Replacing ISU contactor............................................... 27 Replacing APBU boards............................................... 27 Replacing ISU APBU unit.............................................. 28 Replacing INU APBU unit.............................................. 29 Replacing batteries................................................... 30 Replacing NAMU-01C and NUIM-62C protection fuses....................... 31 Crowbar heating..................................................... 31 ACU Cabinet extra fan heater replacement................................ 31 5. Technical data Contents of this chapter................................................. 33

6 Converter types....................................................... 33 Control upgrade....................................................... 33 Power consumption of auxiliary devices.................................... 34 Boards, Un 24 V DC................................................. 34 Further information Product and service inquiries............................................. 35 Product training....................................................... 35 Providing feedback on ABB Drives manuals................................. 35

About this manual 7 1 About this manual Contents of this chapter This chapter describes the intended audience, purpose and contents of the manual. Safety instructions For the safety instructions, see ACS800-67 wind turbine converters for asynchronous slipring generators hardware manual (3AFE68392454 [English]). Obey the safety instructions when installing, operating and maintaining the wind turbine converter. If ignored, physical injury or death may follow, or damage may occur to the converter, the generator or driven equipment. Read the safety instructions before you work on the converter cabinet. Target audience This manual is intended for people who install and service the converter. Read the manual before working on the converter. You are expected to know the fundamentals of electricity, wiring, electrical components and electrical schematic symbols. Contents of this manual The chapters of this manual are briefly described below. About this manual introduces this manual. Hardware description describes the cabinet layout and shows the positions where the upgrade kits are installed. Installation points out the order of installation and describes where to find the detailed installation instructions for each kit.

8 About this manual Maintenance describes the maintenance procedures insofar as they differ from the maintenance without the upgrade kits. Technical data includes the power consumption of the upgrade kit components. There are no changes in technical ratings of the converter. Applicability and scope This supplement contains additional information for the ACS800-67 hardware manual (3AFE68392454 [English]). The supplement covers the following upgrade kits: ACS800-67 Remote connection kit ACS800-67 3G Modem kit ACS800-67 ISU APBU kit ACS800-67 Crowbar kit ACS800-67 NAMU kit ACS800-67 Fuses kit ACS800-67 ISU contactor AF305 kit ACS800-67 Crowbar ACBU-A2 heating system kit ACS800-67 ACU extra heater kit In addition to this supplement, there is a separate installation instructions document for each kit.

About this manual 9 Terms and abbreviations AMC APBU DDCS IGBT INU ISU NAMU-01C NDBU NDCU NETA-21 NEXA-21 NIOC NTAC-02 NUIM-62C RDCO RDCU RMIO Stress Check Application and Motor Controller Board. Part of the NDCU Drive Control Unit See NDCU and NAMC PPCS branching unit. Used with parallel connected converters. Distributed Drives Communication System. Communication protocol used with fibre optic link. Insulated Gate Bipolar Transistor. A voltage controlled semiconductor type widely used in converters due to their easy controllability and high switching frequency. Inverter Supply Unit, i.e. rotor-side converter IGBT Supply Unit, i.e. grid-side converter Auxiliary measuring unit. Performs voltage and current measurement DDCS Branching Unit Drive Control Unit. Consists of a NAMC board and NIOC board built into a metal housing. NDCU-33 unit controls the rotor-side converter Ethernet Adapter Module Extension module for NETA-21, allows drive to be connetcted to NETA-21 through fiber optic channel Input/Output Board. Part of the NDCU Drive Control unit Pulse Encoder Interface Module Voltage and Current Measurement Unit DDCS Communication Option with optic fibre channels Drive Control Unit which contains an RMIO (Motor Control and I/O) board. An RDCU unit controls the grid-side converter. Motor Control and I/O Board. Part of the RDCU Drive Control Unit ABB Stress Check service surveys and analyzes the impact of stress from the environment on the converter, thus giving maintenance recommendations and valuable operational advice.

10 About this manual

Hardware description 11 2 Hardware description Contents of this chapter This chapter describes the cabinet layout and the purpose of the upgrade kits.

12 Hardware description Cabinet layout An example layout of the converter is presented in the following figure. 6 5 1 2 3 4 1 Grid-side converter module (ISU) 2 LCL filter module 3 Rotor-side converter module (INU) 4 Rotor-side converter module (INU) 5 Crowbar assembly (ACBU-A2 and ACBU-R2) 6 ACU cubicle including slide-out frame

Hardware description 13 Upgrade kits The following figure shows the installation position of the kits in the cabinet. 5 3 6 4 8 1 2 9 7 No Name Description 1 ACS800-67 Remote connection kit 2 ACS800-67 3G Modem kit 3 ACS800-67 ISU APBU kit The kit enables constant monitoring and analysis of the performance of the converter. With the new NETA-21 ethernet adapter module robust local data storage is possible. The kit provides remote mobile connection when a wired local internet connection is not available. Extra datalogger unit APBU gathers high-frequency data for any fault in the grid-side converters for precise fault tracing. 4 ACS800-67 Crowbar kit The new Active crowbar unit (ACBU-A2) has a fully-enclosed design that accommodates the latest revisions of IGBT and PCBA technology. The crowbar uses cutting edge self-protection, which enhances its durability and performance against various grid-transient behaviors, thus significantly increasing system availability. The kit also includes crowbar resistor ACBU-R2. 5 ACS800-67 NAMU kit NAMU-01C board measures the grid phase voltages accurately improving the performance related to grid voltage monitoring. 6 ACS800-67 Fuses kit Fuses kit includes NAMU-01C and NUIM-62C voltage measurement boards' protection fuses. If a power cabinet G8x is included in the installation, the fuses are installed in it to replace the protection contactors FG001 and FG003. If no power cabinet exists, it is possible to include the protection fuses on NAMU and NDBU installation plate, opposite to slide-out frame. The protection fuses are normally installed during the same installation as the NAMU units.

14 Hardware description 7 ACS800-67 ISU contactor AF305 kit 8 ACS800-67 Crowbar ACBU-A2 heating system kit 9 ACS800-67 ACU extra heater kit A new, fully-compatible and redesigned version of contactor, AF305. The kit includes new busbars. A heating resistor kit for new Active crowbar unit, installed above LCL filter module. Auxiliary control unit extra heater is required for heating of NETA-21, 3G Modem, NAMU-01C and NDBU-95 units in cold conditions. These units have been typically installed in ACS800-67 upgrade package. Other upgrades Optional kits Brake chopper ABRU-25 & resistor (68958661) Slide-out frame fixing kit (3AXD50000043604)

Installation 15 3 Installation Contents of this chapter This chapter describes the order of installation and describes where to find the detailed installation instructions for each kit. Safety instructions WARNING! Only qualified electrical professionals are allowed to carry out the work described in this document. WARNING! Before you start installing make sure by disconnecting that no voltage cannot be connected to the converter from any power source, ie: from the power grid from the generator (rotor or stator) from an external auxiliary power supply. Lock and tack the disconnecting devices. If there is no disconnecting device between the rotor and the wind turbine converter, lock the rotor reliably. After switching off the power, wait for at least 5 minutes so that the voltage of the intermediate circuit capacitors gets lower than the safety level. Confirm that the DC-voltage is less than 5 V with a multimeter. Ignoring the safety instructions can cause injury or even death.

16 Installation Installation process with stress check period This section describes the installation order for the kits. For the actual installation instructions for each kit, see the appropriate installation instructions, see section Installation instructions 1. Install Remote connection kit, 3G Modem kit and ISU APBU kit are first to enable stress check period, before installing the other upgrades. 2. After the stress check period, continue the installation by uninstalling and removing first all three R8i power modules and LCL filter module. 3. Uninstall the old crowbar and install the new Crowbar Kit. 4. Uninstall the ISU contactor (placed behind LCL filter module) and its busbars. Install the new ISU Contactor AF305 Kit. 5. Install the new R8i modules and new LCL filter module. 6. Install the Crowbar ACBU-A2 Heating System Kit. 7. Install the NAMU 1 Kit and Fuses Kit. 8. Load in the new INU and ISU firmware packages and update the parameters. Installation process when all installations are done simultaneously (no stress check period) This section describes the installation order for the kits. For the actual installation instructions for each kit, see the appropriate installation instructions, see section Installation instructions 1. Install upgrades into ACU field: Install Remote connection kit, 3G Modem kit and ISU APBU kit. Install the NAMU 1 kit and Fuses kit. 2. Continue the installation by uninstalling and removing all three R8i power modules and LCL filter module. 3. Uninstall the old crowbar and install the new Crowbar kit. 4. Uninstall the ISU contactor (placed behind LCL filter module) and its busbars. 5. Install the new ISU Contactor AF305 kit. 6. Install the new R8i modules and new LCL filter module. 7. Install the Crowbar ACBU-A2 heating system kit. 8. Load in the new INU and ISU firmware packages and update the parameters.

Installation 17 Installation instructions The detailed instructions for installing the kits are presented in the following documents: ACS800-67 Remote connection kit installation instruction ACS800-67 3G Modem kit installation instruction ACS800-67 ISU APBU kit installation instruction ACS800-67 Crowbar kit installation instruction ACS800-67 NAMU kit installation instruction ACS800-67 Fuses kit installation instruction ACS800-67 ISU Contactor AF305 kit installation instruction ACS800-67 Crowbar ACBU-A2 heating system kit installation instruction ACS800-67 ACU extra heater kit installation instruction

18 Installation

Maintenance 19 4 Maintenance Contents of this chapter This chapter contains the updated preventive maintenance instructions for ACS800 wind turbine converters that have the upgrade kits installed. For the complete maintenance instructions, see ACS800-67 Wind turbine converters for asynchronous slip ring generators hardware manual (3AFE68392454 [English]). Safety instructions WARNING! Only qualified electrical professionals are allowed to carry out the work described in this document. WARNING! Before you start installing make sure by disconnecting that no voltage cannot be connected to the converter from any power source, ie: from the power grid from the generator (rotor or stator) from an external auxiliary power supply. Lock and tack the disconnecting devices. If there is no disconnecting device between the rotor and the wind turbine converter, lock the rotor reliably. After switching off the power, wait for at least 5 minutes so that the voltage of the intermediate circuit capacitors gets lower than the safety level. At the same time, confirm that the DC-voltage is less than 5 V with a multimeter. Ignoring the safety instructions can cause injury or even death.

20 Maintenance Maintenance intervals The table below shows the maintenance tasks for ACS800 air-cooled wind turbine converters. For more information, consult your local ABB Service representative (www.abb.com/searchchannels). The maintenance and component replacement intervals are based on the assumption that the equipment is operated within the specified ratings and ambient conditions. ABB recommends annual drive inspections to ensure the highest reliability and optimum performance. Note: Long term operation near the specified maximum ratings or ambient conditions may require shorter maintenance intervals for certain components. Consult your local ABB Service representative for additional maintenance recommendations. Description of symbols Action Description R I P Replacement of component (At rated load and ambient conditions) Inspection (visual inspection, correction and replacement if needed) Performance of on-site work (commissioning, tests, measurements, etc.) Recommended maintenance intervals ACS800 Air-cooled wind turbine converter Years from start-up 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 Cooling, air cooled unit Cooling fans I I I I I R 1) I I I I I R 1) I I I I I R 1) I I I Heating Heating fan I I I I I I I I R I I I I I I I I R I I I Aging Memory backup battery replacement in APBU unit NETA-21 battery replacement I I I I R I I I I I R I I I I I R I I I R R R R ALCL filter capacitor2) I/R I I/R I I/R I Connections & Surroundings AINT, AITF, APOW, AFCB, AFPS and cables Tightness of terminals I I I Cabinet air filters R R R R R R R R R R R R R R R R R R R R R Module air filters R R R R R R R R R R R R R R R R R R R R R Condition of contactors I I I I I I I I I I I I I I I I I I I I I R R Main contactors (maintenance according to manufacturer instructions) I I I I I I I I I P I I I I I I I I I P I

Maintenance 21 Air circuit breaker (maintenance according to manufacturer instructions) Fiber optic cables (connections) Dustiness, corrosion and temperature Improvements Based on product notes Measurements Basic measurements with supply voltage Quality of supply voltage Spare Parts I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I P P P P P P P P P P P P P P P P P P P P P I I I I I I I I I I I I I I I I I I I I I Spare Parts I I I I I I I I I I I I I I I I I I I I I 3AXD10000613694 1) Depending on actual load and ambient conditions, up to 9 years can be reached with long-life inverter module fans. 2) If filter is not replaced, the filter shall be inspected after 3 years from the last inspection. Maintenance instructions Active crowbar A2 and/or crowbar resistor replacement Note: Make sure that the crowbar resistor has cooled down before maintenance. This replacement instruction is applicable when upgrade kits for crowbar ACBU-A2 and resistor ACBU-R2 kit have been installed. Note before you start the replacement work: The assembly weighs 15 kg. Be careful not to drop it. - To avoid scratches or other damage inside the cabinet, we recommend that you use a suitable protective/support board (eg, piece of plywood) on the busbars below the assembly to be removed. - You need a sturdy working base, and proper reach to the assembly. We recommend that you use bench ladders. 1. Detach the crowbar assembly from the cabinet. i. Unfasten crowbar screws on the front side ii. Unfasten screw on left side iii. Unfasten screw on right side iv. Lower the crowbar assembly on the protective board on the busbars above inverter modules

22 Maintenance 3. Uninstall the crowbar heat shielding plate (3AXD50000104062). Unfasten screws and remove the heat shielding plate by pulling it out from the locking mechanism. 4. Uninstall the DC measurement cables and overtemperature protection wires from terminals in the crowbar assembly. 5. Open the crowbar cover by unfastening four flathead screws. Use short ratchet wrench with a flathead screw bit. Remove the crowbar cover from cabinet. 6. When the crowbar cover is removed, uninstall the optical cable inside the crowbar. 7. Uninstall the 3-phase rotor cable wires from crowbar connectors. 8. Lift the crowbar assembly out from the cabinet and place it onto a stable surface. 9. Disconnect the busbars (3AXD50000103942 and 3AXD50000103959) from the resistor.

Maintenance 23 10. Depending on the situation, uninstall and replace with a new unit: either crowbar unit, crowbar resistor, or both. The photo below shows how to detach the crowbar resistor assembly from the base plate.

24 Maintenance Installing the crowbar assembly back to cabinet See Instruction for the crowbar ACBU-A2 and resistor ACBU-R2 kit installation for ACS800-67 wind turbine converter. 1. Prepare the crowbar ACBU-A2 and resistor ACBU-R2. Install the resistor shielding plate (3AXD50000104079) with screws on resistor. 2. Lift base plate (3AXD50000103805) on the new crowbar and attach it with screws. Turn the entity around and open the crowbar cover by unscrewing the four flathead screws. 3. Install the crowbar resistor assembly on base plate. 4. Lift the crowbar assembly on the busbars above inverter modules. A separate support board can be used under the assembly to avoid scratches. Use bench ladder to make the installation easier. 5. Connect the 3-phase rotor cable wires on crowbar connectors. 6. Connect the optical cable inside crowbar. 7. Screw the crowbar cover back to its original place with four flathead screws. Use short ratchet wrench with a flathead screw bit. 8. Connect the DC measurement cables and overtemperature protection wires on terminals. 9. Install the crowbar heat shielding plate (3AXD50000104062). Use the locking mechanisms and two front screws. 10. Attach the new crowbar assembly to converter cabinet. 11. Check the installation after assembling: After finishing the connections check with a multimeter that all electrical connections are correct and that fiber optic cable connections are as described. The following table describes fiber optic connections. Function Designation Designation Remarks Device Con. Device Con. DDCS comms ACBU-A2 A3: V1 TxD A719 AMC-33C A3: V1 RxD A720

Maintenance 25 The following table describes control wirings and DC voltage measurement wirings. Function Designation Designation Remarks Device Con. Device Con. DC voltage measurement Crowbar active Main CB fast OFF Crowbar temperature ACBU-A2 X11- DMC:2 DC X11+ DCP:2 X1:1 -X22:7 NIOC-01 X1:2 -X22:5 X2:4 31 *) -K3 X2:6 32 *) X12:1 -F12 11 X12:2 -K6 11 *) In ACS800-67-0480/0770-7 the crowbar X2:4 is connected instead of -K3:31 to -K5:21 and crowbar X2:6 instead of -K3:32 to -K21:11. The following table describes 3-phase wiring to inverter modules. Function Designation Designation Remarks Device Con. Device Con. 3-phase connection ACBU-A2 U2 V2 INU U2 V2 W2 W2 NDBU and NAMU plate replacement Follow the instructions given in Instruction for the NAMU kits installation for ACS800-67 wind turbine converter. 1. Unmount auxiliary supply filter (-z3), ACU cabinet fan (-E11) and temporized relay (-k3.1) in order to make room to install the support plate installation. 2. Unscrew the NAMU/NDBU plate fixing screws. Use ratchet wrench set with extensions and sockets for rear screw. 3. Remove the NAMU/NDBU plate from the cabinet. 4. Replace NAMU-01C or NDBU-95C on installation plate DIN rail. Do the jumper settings according to the table below. Terminal Jumper X8 1-2 X11 1-2, 3-4 X12 1-2, 3-4 X13 1-2, 3-4 X14 1-2, 3-4 X15 1-2 X21 1-2, 3-4, 5-6, 7-8, 9-10

26 Maintenance Terminal Jumper X22 1-2, 3-4, 5-6, 7-8, 9-10 X23 1-2, 3-4, 5-6, 7-8, 9-10 X24 1-2, 3-4, 5-6, 7-8, 9-10 X31 3-4 X32 3-4 X33 3-4 X34 3-4 S1 0 S2 0 5. Make the cable connections according to the tables below. Route all the wires through the cable ducts. Function Designation Designation Device Con. Device Con. DDCS comms NAMU V11 TxD RDCO CH2 RxD V12 RxD CH2 TxD Function Designation Designation Device Con. Device Con. U10, 24 V DC + NAMU X6.1 Supply U10, 0 V DC - NAMU X6.2 PE PE NAMU X6.3 Function Designation Designation Device Con. Device Con. -1X2 3 NAMU X1.7 Supply -1X2 2 NAMU X1.5-1X2 1 NAMU X1.3 TE TE X1.1 6. Install the NAMU/NDBU plate in the opposite order than it was uninstalled: Move the plate inside the cabinet, attach it with the screws and mount auxiliary supply filter (-z3), ACU cabinet fan (-E11) and temporized relay (-k3.1) back to their original positions.

Maintenance 27 Replacing ISU contactor See ACS800-67 ISU contactor AF305 kit installation instruction for additional information. 1. Remove first the LCL filter module. The ISU contactor AF305 is behind it. 2. Uninstall four measurement wires, 2 above and 2 under the contactor to allow moving of the busbars. 3. To remove the upper busbars uninstall first the insulation plate. Use special ring spanner or corresponding tool for the nut behind busbar. Remove all three busbars. 4. Remove also the busbar bolts for the three busbars under the contactor and remove the contactor. 5. Install the new contactor, then remount the upper busbars, measurement wires and insulation plate. Use the correct torque 28 Nm, when tightening the contactor bolts. 6. After installation measure the connections with a multimeter. 7. Reinstall the LCL filter module. Replacing APBU boards APBU boards are installed on slide-out frame. APBU unit for INU is installed on DIN rail located directly on slide-out frame. When Remote connection kit is installed, also ISU APBU kit can be installed on a support plate (3AXD50000104222) on top of INU APBU unit. ISU APBU unit and power supply on support plate. INU APBU unit is located behind the support plate.

28 Maintenance The support plate without ISU APBU unit. INU APBU when the support plate is removed. Replacing ISU APBU unit 1. ISU APBU unit can be unmounted easily by detaching cables and taking the unit out from the DIN rail. 2. Before installing new ISU APBU unit, set the node address to 41 with S1 and S2 switches. 3. Install the APBU on the DIN rail on the support plate (3AXD50000104222). 4. Connect cables according to following tables.

Maintenance 29 Function Designation Designation Device Con. Device Con. Supply -X500+24 V DC + ISU APBU X1.1 -X500 0 V DC - ISU APBU X1.2 Function Designation Designation Device Con. Device Con. DDCS TXT DDCS RXD NDBU CH3 CH3 DDCS comms ISU APBU CNTL RXD CNTL TXD TRIG OUT TRIG IN RDCU INU APBU TXD RXD TRIG IN TRIG OUT CH1TXD CH1 RXD ISU 1 (R8i module) A42:V2 A42:V1 5. After commissioning, set S3 DIP switch 6: Battery to position ON. Note: Do not set S3 DIP switch to ON before commissioning. Check that ISU parameter 112.16 PBU board type = APBU. Replacing INU APBU unit INU APBU unit is located behind ISU APBU unit and the support plate (3AXD50000104222). ISU APBU unit and power supply (64209426) can be detached first from DIN rail. 1. Support plate needs to be removed first in order to get access to INU APBU. Detach M6 self-tapping screws (5 pcs) and take out the support plate.

30 Maintenance 2. INU APBU unit is mounted on DIN rail. Replace the unit. Fiber optic connections of INU APBU unit are presented in the table below. Function Designation Designation Device Con. Device Con. DDCS TXT DDCS RXD NDBU CH2 CH2 CNTL RXD CNTL TXD RDCU TXD RXD DDCS comms ISU APBU TRIG OUT TRIG IN ISU APBU TRIG IN TRIG OUT CH1TXD CH1 RXD INU 1 A42:V2 A42:V1 CH2TXD CH2 RXD INU 2 A42:V2 A42:V1 The following figure describes the fiber optic connection diagram. 3. Reinstall the support plate (3AXD50000104222) with five M6 self-tapping screws. 4. Mount ISU APBU unit and power supply back on the support plate. Replacing batteries Replace NETA-21 battery every 5 years. Refer to NETA-21 manual (3AUA0000096939 Rev E).

Maintenance 31 Replacing NAMU-01C and NUIM-62C protection fuses NAMU and NUIM protection fuses are placed in power cabinet. Refer to ACS800-67 Fuses kit installation instruction. Remark: For ACS800-67-0480/0770-7 the protection fuses are in ACU field on the same support plate as NDBU and NAMU, opposite to the slide-out frame. Type ABB MRP In Un Qty A070GRB2T13, Z330003 68379270 2 A 700 V 6 Crowbar heating For replacement of the crowbar heating kit parts, please refer to ACS800-67 Crowbar ACBU-A2 heating system kit installation instruction. ACU Cabinet extra fan heater replacement ACU extra fan heater is located on a support plate, close to the back of the ACU cubicle. 1. Unmount the air guide plate in front of the fan heater. The guide plate is attached with a screw in front of fan heater. 2. Unmount the screw attaching the fan heater assembly on the cabinet floor. 3. Lift the fan heater assembly outside the ACU cabinet and uninstall its power supply wires. 4. Loosen the four screws of the fan heater attachment frame and replace the fan heater with a new one. 5. Tighten the fan frame screws, install the power supply wires and mount the fan heater assembly and air guide back inside the ACU cabinet to their original places.

32 Maintenance

Technical data 33 5 Technical data Contents of this chapter ACS800-67 upgrade kits do not affect the converter's technical ratings. Technical ratings are given in ACS800-67 Wind turbine converters for asynchronous slip ring generators hardware manual (3AFE68392454 [English]). Converter types Converter type Grid-side converter frame size Grid-side converter nominal rating Icont.max (AC) [ A] Rotor-side converter frame size Rotor-side converter nominal rating Icont.max (AC) [A] ACS800-67-0480/0580-7 R8i 400 R8i 486 ACS800-67-0480/0770-7 R8i 400 2xR8i 645 ACS800-67-0480/1160-7 R8i 400 2xR8i 953 Note that the type code for the R8i converter module used in the ACS800-67 deliveries today is ACS800-104-0585-7+C123+C124+C126+E205+E212+V991. Control upgrade The upgrade kits described in this manual require software update for R8i modules, see ACS800-67 upgrade wind turbine converters supplement (3AXD50000131303 [English]).

34 Technical data Power consumption of auxiliary devices Boards, Un 24 V DC Module Amount (pcs) In [ma] Imax [ma] RDCU-12 1 250 1200 AMC 1 500 500 NIOC 1 300 600 APBU-44C 2 400 400 NDBU 1 250 320 NUIM-62C 1 200 200 NAMU-01C 1 100 150 NTAC-02 1 250 250 NCAN-02C 1 30 30 NETA-21 & NEXA-21 1 200 500 3G Modem 1 200 200 TOTAL 2680 4350

Further information Product and service inquiries Address any inquiries about the product to your local ABB representative, quoting the type designation and serial number of the unit in question. A listing of ABB sales, support and service contacts can be found by navigating to www.abb.com/searchchannels. Product training For information on ABB product training, navigate to www.abb.com/service/training. Providing feedback on ABB Drives manuals Your comments on our manuals are welcome. Go to www.abb.com/drives/manualsfeedback-form.

Contact us www.abb.com/windconverters 3AXD50000226726 Rev. A (EN) 2018-02-15