INTRODUCTION Where lighting must fulfill both architectural and practical purposes the Surface and Suspended Runway provides a slim line appearance with an anodised aluminium housing offering the versatility of a range of lengths and lumen outputs as well as bidirectional variants ensuring that you can create a layout that enhances any space creating an attractive environment for workers or enticing potential customers. This flexibility is further enhanced with integral emergency, white tunable and dimming options and two optic styles, a minimalist opal finish or microprism for compliance with the 3000 candela requirements of BSEN12464 for use in office and school areas (L22, L14 and L29 variants only). The Runway also incorporates the latest mid power LEDs ensuring optimal energy efficiency with minimal need for maintenance over the course of its lifetime. The Runway is also available in a range of continuous run and recessed options where required. APPLICATION Education Office Retail T: 01747 858100 E: sales@dextralighting.co.uk Page 1 of 12
SPECIFICATION Construction Extruded aluminium trunking with clear anodised finish. Die cast aluminium end caps. High transmission opal diffuser with optional microprism insert for BSEN 12464 3000 candela compliance (L22, L14 and L29 variants only). Suitable for surface mount or suspended installation. Performance Available in a wide range of lumen packages including glare compliant versions compliant with BSEN12464 3000 candela requirement. Philips Lumileds LM80 verified: 90% LED lumen maintenance at 60,000 operating hours. Philips Lumileds LM80 verified: B10 10% of LED s will exceed 10% lumen depreciation at 60,000 operating hours. Standard Deviation Colour Match 3 Step Macadam s Ellipse. Bi-directional available (1500 module and suspended version only) Control Available with DALI, Digital Dimming, Analogue Dimming and Switch Dimming. White Tunable, Lumen outputs vary, please contact our sales department for details Emergency Available with optional standard, self test and autotest emergency integral control gear. Installation Trunking sections available in 1500mm and 3000mm lengths. Gear trays in 1500mm and 1000mm with quick release clips for ease of installation into trunking system. All trays supplied complete with 6 core 1.5mm through wire loom. Available in a range of lengths from 1500mm to 1000mm to allow the run length to be customised to the room size. Variations Bi directional version available in 1500 module and suspended version only. IMAGES Product Images T: 01747 858100 E: sales@dextralighting.co.uk Page 2 of 12
Project Images T: 01747 858100 E: sales@dextralighting.co.uk Page 3 of 12
T: 01747 858100 E: sales@dextralighting.co.uk Page 4 of 12
TECHNICAL Runway Surface / Suspended Standalone 1500mm Runway Surface / Suspended Standalone 1000mm T: 01747 858100 E: sales@dextralighting.co.uk Page 5 of 12
WARRANTY All Dextra products are supplied with a 12 month warranty for any defect that may occur with the product during this time. Any defect will either be repaired on site free of charge or the defective product may be replaced on a chargeable basis and credit given against defective product returned. The course of action taken will be at our discretion and dependent on the nature of the defect. The control gear within our high frequency and LED luminaires is further underwritten by our suppliers for a period of up to 5 years in total from the time of purchase. This comprises labour and parts for the first 3 years and free of charge components only for the final 2 years. PROTEC LED FR 8W GU10 luminaires and all Emergency LED ranges such as LED 3, EXI, HBE, OAT, OEZ, AME, OEH and TWS * are exempt from the 5 year warranty and are supplied with 1 year warranty only. PROTEC LED COB luminaires are supplied with a two year warranty for replacement luminaires only. All warranties are subject to correct use of the product and will be invalidated by misuse, for example incorrect installation or unsuitable environmental conditions. It is the duty of the customer to ensure that all relevant tests have been carried out prior to requesting site visits or replacement products, for example replacement of lamps, commissioning of sensors and inspection of external wiring. In the event that no defect is found with the product our costs for attending site will be recharged to the customer and credit will not be issued against returned products. No consequential losses incurred resulting from any defect with our product will be reimbursed. Consumable commodities such as lamps, starters and batteries are excluded from these warranty terms. Batteries are supplied with a twelve month warranty only. 5 year warranty on LED product ranges is subject to a maximum of 4000 operating hours per year and only applies where failures exceed the component manufacturers expected failure rate and lumen depreciation. If you require any assistance with regards to our products please do not hesitate to contact our Customer Services department on 01747 858100. *The LED4 Emergency LED range is supplied with a three year battery warranty and 5 year luminaire warranty. ORDER CODES Luminaire Codes Code Description Circuit Wattage Llm/w Standalone Surface / Suspended *RWY 1000 L14 MP C84 Runway, 1000mm, 871llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 84 (ECA) 9.5w 91 RWY 1000 L20 OP C84 Runway, 1000mm, 1331llm, Standalone, Surface / Suspended, Opal Diffuser, Colour 84 (ECA) 13.6w 97 RWY 1000 L20 MP C84 Runway, 1000mm, 1233llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 13.6w 84 (ECA) 90 RWY 1000 L30 OP C84 Runway, 1000mm, 2000llm, Standalone, Surface / Suspended, Opal Diffuser, Colour 84 (ECA) 100 T: 01747 858100 E: sales@dextralighting.co.uk Page 6 of 12 20.0w
RWY 1000 L30 MP C84 Runway, 1000mm, 1853llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 20.0w 84 (ECA) 92 *RWY 1500 L22 MP C84 Runway, 1500mm, 1519llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 13.9w 84 (ECA) 109 RWY 1500 L30 OP C84 Runway, 1500mm, 2221llm, Standalone, Surface / Suspended, Opal Diffuser, Colour 84 (ECA) 18.8w 118 RWY 1500 L30 MP C84 Runway, 1500mm, 2072llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 18.8w 84 (ECA) 110 RWY 1500 L45 OP C84 Runway, 1500mm, 3331llm, Standalone, Surface / Suspended, Opal Diffuser, Colour 84 (ECA) 28.3w 117 RWY 1500 L45 MP C84 Runway, 1500mm, 3108llm, Standalone, Surface / Suspended, Microprism Diffuser, Colour 28.3w 84 (ECA) 109 *RWY 1500 L29 BD MP C84 Runway, 1500mm, 1929llm, Standalone, Surface / Suspended, Bidirectional (75% Down, 25% Up), Microprism Diffuser, Colour 84 (ECA) 17.3w 111 RWY 1500 L40 BD OP C84 Runway, 1500mm, 2829llm, Standalone, Surface / Suspended, Bidirectional (75% Down, 25% Up), Opal Diffuser, Colour 84 (ECA) 24.3w 116 RWY 1500 L40 BD MP C84 Runway, 1500mm, 2660llm, Standalone, Surface / Suspended, Bidirectional (75% Down, 25% Up), Microprism Diffuser, Colour 84 (ECA) 24.3w 109 RWY 1500 L60 BD OP C84 Runway, 1500mm, 4244llm, Standalone, Surface / Suspended, Bidirectional (75% Down, 25% Up), Opal Diffuser, Colour 84 (ECA) 37.7w 112 RWY 1500 L60 BD MP C84 Runway, 1500mm, 3990llm, Standalone, Surface / Suspended, Bidirectional (75% Down, 25% Up), Microprism Diffuser, Colour 84 (ECA) 37.7w 105 *BSEN 12464 3000 candela compliant variant. Bi directional only suitable for suspended installation in 1500mm module. Available in black and white finish on request subject to additional lead times. Dimming Options Code Description H High Frequency Dimming (Analogue 1-10v) S Switch Dimming A Digital Addressable Lighting Interface (DALI) D Digital Dimming (DSI) C Bi-Level Dimming WT White Tunable, Lumen outputs vary, please contact our sales department for details Please click here for full details on our white tunable offer Lighting Controls Code Description R24H Reacta 24H, Minihead Daylight and Presence Detection Sensor EA Easy Air Wireless linking sensor, daylight regulation and presence detection. Please click here for full details on our wireless controls. Emergency Code Description E3 3 Hour Integral Emergency ST3 Self Test AT3 Autotest Emergency STR Emergency Reacta-Link Emergency is only available in 1500mm variants. Dimming versions are only available with E3 and ST3. Dimming can not be combined with AT3 Autotest Emergency. Miscellaneous Code Description WH White Finish BL Black Finish RWY SUSP 3M Runway 3M suspension kit (one drop, two kits required per luminaire) T: 01747 858100 E: sales@dextralighting.co.uk Page 7 of 12
RWY SMK Runway Surface Mount Kit RWY INSTALL KIT Runway Installation Kit Two suspension or surface kits are required per luminaire.
Runway Suspended / Surface Standalone Installation 230-240V / 50-60Hz IP20 IK00 + WARNING - THIS LUMINAIRE MUST BE EARTHED This luminaire has been tested and is manufactured to comply with BS EN 60598 : specification for general requirements and tests. It should be installed by a suitably qualified person in accordance with IEE. CAUTION: there is a potential risk of electric shock from the LED boards when the product is operational with the cover removed. NOTE: INSTALLATION AND OPERATION OF THE LUMINAIRE BEYOND ITS SCOPE OF SUPPLY WILL INVALIDATE THE WARRANTY. 2.0 DIL-0119-0002 1a. 2948mm Standalone (suspended) 2548 1.1b. 2. 1474mm Standalone (suspended) Attach the suspension wire the spring brackets ready to be attached to the trunking. 1074 3. 4. Secure suspension drops as shown in marked positions. Screw suspension wire and clutch into ceiling fixture. Correct Orientation DIL-0119-0002 Page 1 Revision - I Wrong Orientation 20/09/2018
Runway Suspended / Surface Standalone Installation 5. Snap the spring brackets onto the trunking and adjust position until the suspension wires hang vertically. 6. Open the starter bracket to allow access to the terminal block. 7. Feed mains cable in through grommet in rear of trunking. Wire into marked terminals as required. 8. Push small tab under lip in trunking to lock in place. Fold starter bracket back into trunking after wiring in mains cable. 9. Locate all tether brackets and clip gear trays to each bracket in the trunking. (Shown without end cap) 10. Connect looms from first gear tray and the starter bracket and between the two main gear trays if applicable. Clip all trays into trunking and allow the trays to hang. 11. 12. Raise gear trays up into the trunking and engage on small leaf springs as shown. NOTE: END CAP NOT SHOWN TO SHOW LEAF SPRING DETAIL. Unpack the diffusers carefully and offer up into the trunking once gear trays are secured in place. They should snap into place easily. DIL-0119-0002 Page 2 Revision - I 20/09/2018
Runway Suspended / Surface Standalone Installation 1. Standalone (surface) 1074 / 2548 2. 3. Secure surface mount brackets to ceiling using suitable screws. Ensure they are positioned correctly. Once spring brackets are attached to ceiling, snap the trunking onto them ensuring they're secure. 4. 5. Open the starter bracket to allow access to the terminal block. 6. Push small tab under lip in trunking to lock in place. Feed mains cable in through grommet in rear of trunking. Wire into marked terminals as required. Fold starter bracket back into trunking after wiring in mains cable. 7. Locate all tether brackets and clip gear trays to each bracket in the trunking. (Shown without end cap) Clip all trays into trunking and allow the trays to hang. DIL-0119-0002 Page 3 Revision - I 20/09/2018
Runway Suspended / Surface Standalone Installation 8. 9. Raise gear trays up into the trunking and engage on small leaf springs. Connect looms from first gear tray and the starter bracket and between the two main gear trays if applicable. 10. 11. Unpack the diffusers carefully and offer up into the trunking once gear trays are secured in place. They should snap into place easily. Engage on small leaf springs as shown. NOTE: END CAP NOT SHOWN TO SHOW LEAF SPRING DETAIL. 12. 13. 14. 15. DIL-0119-0002 Page 4 Revision - I 20/09/2018